Sei sulla pagina 1di 2

Checklist

Taking grout samples

Application
This document applies to: International
Mechanical Induction Installation Update Precast concrete tower Installation
Electrical Rotor blade Grid connection Concrete repair Precast concrete tower Prestressing

BF 82 11 01 BF 97 17 01 BF 102 17 01 BF 112 24 02 BF 133 37 01


BF 82 17 05 BF 97 20 01 BF 102 17 02 BF 122 25 01 BF 137 24 01
BF 83 17 01 BF 97 20 02 BF 107 17 01 BF 131 36 02 BF 137 25 02
BF 83 17 02 BF 97 20 03 BF 107 23 01 BF 131 36 04 BF 147 31 01
BF 83 17 03 BF 97 20 05 BF 107 23 05 BF 133 27 01 BF 147 36 01

Document details
Document ID TD-esc-03-ger-eng-13-016 Rev001 Taking grout samples

Confidentiality FOR INTERNAL USE

Date Language DCC Plant/department

Copyright ENERCON GmbH. All rights reserved.


2014-07-15 eng WT Service Deutschland GmbH/Concrete Engineering

TD-esc-03-ger-eng-13-016 Rev001 Taking grout samples i of i


Checklist
Taking grout samples

1 Taking grout samples

1.1 General information


Team leader Date
Phone number Country
Manufacturer Name of sampling
person
Project name W no. / WBS (PSP) no.
Location Tower type

1.2 Sampling details/temperatures


Name of test specimen Batch number Sampling date/time Temperature
Specimen mould Test specimen Date Time Air Concrete
no. no.
A1

Copyright ENERCON GmbH. All rights reserved.


A2
B3
M4
M5
M6
E7
E8
E9

1.3 Comments (deviation from sampling method, etc.)

We hereby confirm that the above activities have been carried out according to the Taking grout
samples instructions. Any damage detected has been recorded in this report.

Date Signature

TD-esc-03-ger-eng-13-016 Rev001 Taking grout samples 1 of 1