Sei sulla pagina 1di 2

TANK

23

Quality, Service & Solutions


11

20
12

22
19
21

18
FROST
LINE
16
10
7
9

17 13 3 10
14 15 2

CASING DROP
3 PIPE
1
9
CHECK VALVE PITLESS 7 17
ADAPTER RELIEF
VALVE
2 10
BRASS ROPE
ADAPTER BRASS INSERT 8
18
FITTING
PRESSURE
GAUGE
3
11
WATERTIGHT
IDEAL CLAMP WELL CAP 19
PRESSURE
7
SWITCH
4 12
HEAT SHRINK WELL 8
SPLICE KIT SEAL
20
SAFETY
5 13
3
SWITCH
CHECK 6
TORQUE ARRESTOR VALVE
21
LIGHTNING
6 14
TANK TEE ARRESTOR
SAFETY 5
ROPE
22
BALL VALVE
7 15
CABLE TIE
DRAIN VALVE 3

4 23
8 10 WATER FILTER
CABLE 16

GUARD BRASS NIPPLE


1

2012 Baker Manufacturing Company, LLC PUMP


www.bakerwatersystems.com
9 PITLESS ADAPTER 19 PRESSURE SWITCH
(Section M) (Section S)
Provides a watertight, sanitary, removable Signals the pump to start when the
The quality water system products
connection between the pump and the water system drops to a preset low
described here and illustrated on the
house. pressure, and to stop when the high
front page are some of the Baker pressure mark is reached.
Installed in casing below the frost line to
Water Systems products used in a
prevent freezing.
typical well system. (The section in the 20 SQUARE D SAFETY SWITCH
catalog where these items can be found 10 (Section S)
BRASS INSERT FITTING
is located in parentheses) (Section A) For electric control and distribution to
Provides connection between poly pipe the pump.
This list and the illustration on the front page are and pipe thread of Pitless Adapter.
not intended as an installation guide. Check local 21 LIGHTNING ARRESTOR
codes for actual requirements and restrictions.
11 WATERTIGHT WELL CAP (Section S)
(Section L) Protects pump motor & controls from
1 CHECK VALVE
Inner gasket compresses to outside voltage surges caused by lightning,
(Section G) switching loads, and power line
Located at the top of the pump, it diameter of casing to provide a watertight
seal. Top of cap removes easily to access interference.
prevents backflow into the pump and
holds the head of water in the system. well for service.
22 BALL VALVE
12 WELL SEAL (Section H)
2 BRASS ROPE ADAPTER Acts as a shutoff valve on the supply
(Section A) (Section K)
Used in above-ground installations to line from the tank to the house.
Connects the Pitless Adapter and the
Submersible Pump with Safety Rope. provide a positive seal inside casing. 23 WATER FILTER
(Section T)
3 IDEAL CLAMPS
13 CHECK VALVE
A point-of-entry, whole-house-filter that
(Section Q) (Section G)
removes rust particles, sand, etc. from
All-stainless steel clamps for dependable On pump installations, a Check Valve
supply water.
connections between Pipe and Insert installed near the tank inlet holds water
Fittings or Torque Arrestor. in the tank when the pump is idle.

14 TANK TEE
4 3M HEAT SHRINK SPLICE KIT
(Section S) (Section O)
For waterproof electric cable splices in Connects water line from pump to For more information on these or
submersible pump installations. pressure tank and service line from tank any of the other 5,000 + products
to house. Taps are provided to accept
offered by Baker Water Systems,
5 TORQUE ARRESTOR
Pressure Switch, Pressure Gauge, Drain
Valve, Relief Valve, Snifter Valve, etc.
please contact:
(Section R)
Installed directly above Submersible
Pumps to protect pump and well
15 DRAIN VALVE Campbell Mfg, LLC
components from starting torque (Section H) 127 East Spring Street
damage. For easy draining of the system. Bechtelsville, PA 19505-0207
16 BRASS NIPPLE Phone: 800-523-0224
6 SAFETY ROPE
(Section D) Fax: 610-369-3580
(Section R)
A safety line from the top of the well to Male threads allow attachment of Pressure E-mail: moreinfo@campbellmfg.com
the pump. Switch to Tank Tee.
Baker Mfg. Co., LLC
7 CABLE TIE
17 RELIEF VALVE
(Section I)
133 Enterprise Street
(Section R) Evansville, WI 53536
Protects against pressure build-up. Should
Fastens Cable to Drop Pipe
be used on any system where the pump Phone: 800-356-5130
could develop greater pressure than the Fax: 608-882-3777
8 CABLE GUARD maximum rating of the system.
(Section R)
E-mail: monitor@baker-mfg.com
U.S. Patent #6,595,284 18 PRESSURE GAUGE
Protects submersible cable wires from (Section R)
abrading against sides of well. Two Measures water pressure in Pressure
styles available: Self-Clamping or
Tank.
Snap-in.