Sei sulla pagina 1di 4

EDIFICIO MULTIFAMILIAR : 8 PISOS - SEMISOTANO - AZOTEA

CLIENTE : J.C.G PROMOTORA INMOBILIARIA

NIVEL ANCHO (X) LARGO (Y) ALTURA AREA MASA J


SEMISOTANO 14.00 36.00 2.80 439.21 44.82 1968.42
1 PISO 14.00 36.00 2.40 337.09 34.40 1159.49
2 PISO 14.00 36.00 2.40 337.09 34.40 1159.49
3 PISO 14.00 36.00 2.40 337.09 34.40 1159.49
4 PISO 14.00 36.00 2.40 337.09 34.40 1159.49
5 PISO 14.00 36.00 2.40 337.09 34.40 1159.49
AZOTEA 14.00 36.00 2.40 170.71 17.42 297.37

SISMO X-X

PARAMETROS SISMICOS Z = 0.40


U = 1.0
S = 1.2
T = 0.82 TP = 0.40
C = 1.22
R = 7.00
ENTONCES C/R = 0.18
ANALISIS

ZUCS
ESTATICO
V= P = 0.07P = 275.32
R

NIVEL hi Pi Pihi Fx Mx
SEMISOTANO 2.80 177.83 497.92 2.25 1.55
1 PISO 5.40 183.60 991.44 4.65 3.20
2 PISO 7.80 183.60 1432.08 6.93 4.77
3 PISO 10.40 183.60 1909.44 9.21 6.34
4 PISO 13.00 183.60 2386.8 11.49 7.91
5 PISO 15.60 183.60 2864.16 13.77 9.48
AZOTEA 26.00 199.22 5179.72 24.82 17.09
1295.05 15261.56 73.12

DINAMICO
ZUCS ( plataforma )
Sa = g = 1.64
R

T (s) Vdinamico Vestatico REGULAR 0.8Vest. Factor


SISMO X-X 0.80 221.27 253.05 0.80 202.44 0.96

DESPLAZAMIENTO DE LOS CENTROS DE MASA

/ he limite = 0.007

NIVEL JOINT U1 U inelastico (cm) (cm.) / he RESULTADO


SEMISOTANO 40 3.00 E-04 0.16 0.16 0.0006 PASA
1 PISO 40 9.00 E-04 0.42 0.27 0.0010 PASA
2 PISO 40 1.80 E-03 0.82 0.40 0.0015 PASA
3 PISO 40 3.00 E-03 1.36 0.54 0.0021 PASA
4 PISO 40 4.40 E-03 1.99 0.63 0.0024 PASA
5 PISO 40 6.00 E-03 2.72 0.72 0.0028 PASA
6 PISO 40 7.80 E-03 3.53 0.81 0.0031 PASA
7 PISO 40 9.60 E-03 4.34 1.08 0.0041 PASA
8 PISO 40 1.20 E-02 5.42 0.68 0.0026 PASA
AZOTEA 40 1.35 E-02 6.11 1.08 0.0041 PASA

DESPLAZAMIENTOS MAXIMOS

NIVEL JOINT U1 U inelastico (cm) (cm.) / he RESULTADO


SEMISOTANO 4 3.00 E-04 0.16 0.16 0.0006 PASA
1 PISO 4 1.00 E-03 0.44 0.28 0.0011 PASA
2 PISO 4 2.00 E-03 0.90 0.46 0.0017 PASA
3 PISO 4 3.40 E-03 1.54 0.64 0.0024 PASA
4 PISO 4 4.90 E-03 2.21 0.68 0.0026 PASA
5 PISO 4 6.70 E-03 3.02 0.81 0.0031 PASA
6 PISO 4 8.60 E-03 3.88 0.86 0.0033 PASA
7 PISO 4 1.05 E-03 4.73 0.85 0.0033 PASA
8 PISO 4 1.20 E-02 5.68 0.94 0.0026 PASA
AZOTEA 4 1.28 E-02 6.58 0.91 0.0035 PASA

JUNTA SISMICA S(formula) = 3+0.004(h-500) = 10.09


S (min) = 3.0
2/3 ( Dmax + Dvec.)
S = 11.09

ENTONCES 2/3 x Dmax = 6.73


S/2 = 5.05

El edificio se retirara : 5.00

EDIFICIO MULTIFAMILIAR : 8 PISOS - SEMISOTANO - AZOTEA

CLIENTE : J.C.G PROMOTORA INMOBILIARIA

NIVEL ANCHO (X) LARGO (Y) ALTURA AREA MASA J


SEMISOTANO 12.45 32.85 2.65 317.09 29.09 1022.89
1 PISO 12.45 32.85 2.60 314.13 28.82 1013.39
2 PISO 12.45 32.85 2.60 312.60 28.67 1008.12
3 PISO 12.45 32.85 2.60 312.60 28.67 1008.12
4 PISO 12.45 32.85 2.60 312.60 28.67 1008.12
5 PISO 12.45 32.85 2.60 312.60 28.67 1008.12
6 PISO 12.45 32.85 2.60 312.60 28.67 1008.12
7 PISO 12.45 32.85 2.60 312.60 28.67 1008.12
8 PISO 12.45 32.85 2.60 312.60 28.67 1008.12
AZOTEA 12.45 32.85 2.60 312.60 28.67 1008.12

SISMO Y-Y

PARAMETROS SISMICOS Z = 0.40


U = 1.0
S = 1.0
T = 1.04 TP = 0.40
C = 0.96
R = 7.00
C/R = 0.14
ENTONCES C/R = 0.14
ANALISIS

ZUCS
ESTATICO
V= P = 0.06P = 173.05
R

NIVEL hi Pi Pihi Fy Mx
SEMISOTANO 2.65 177.83 471.25 1.33 1.28
1 PISO 5.30 183.60 973.08 2.75 2.65
2 PISO 7.90 183.60 1450.44 4.11 3.96
3 PISO 10.50 183.60 1927.80 5.46 5.26
4 PISO 13.10 183.60 2405.16 6.81 6.56
5 PISO 15.70 183.60 2882.52 8.16 7.86
6 PISO 18.30 183.60 3359.88 9.51 9.16
7 PISO 20.90 199.22 4163.70 11.79 11.36
8 PISO 23.50 199.22 4681.67 13.26 12.77
AZOTEA 26.10 199.22 5199.64 14.72 14.17
1877.09 27515.14 77.9

ZUCS
DINAMICO ( plataforma )
Sa = g = 1.40
R

T (s) Vdinamico Vestatico REGULAR 0.8Vest. Factor


SISMO Y-Y 1.02 126.95 150.05 0.80 120.04 1.01

DESPLAZAMIENTO DE LOS CENTROS DE MASA

/ he limite = 0.007

NIVEL JOINT U2 U inelastico (cm) (cm.) / he RESULTADO


SEMISOTANO 40 6.00 E-04 0.32 0.32 0.0012 PASA
1 PISO 40 2.10 E-04 1.10 0.79 0.0029 PASA
2 PISO 40 4.10 E-03 2.15 1.05 0.0039 PASA
3 PISO 40 6.30 E-03 3.31 1.16 0.0044 PASA
4 PISO 40 8.60 E-03 4.52 1.21 0.0046 PASA
5 PISO 40 9.70 E-03 5.78 1.26 0.0048 PASA
6 PISO 40 1.10 E-03 7.04 1.26 0.0048 PASA
7 PISO 40 1.34 E-03 8.24 1.21 0.0046 PASA
8 PISO 40 1.57 E-02 10.55 2.31 0.0088 RIGIDAZAR
AZOTEA 40 2.35 E-02 10.61 0.05 0.0002 PASA

DESPLAZAMIENTOS MAXIMOS

NIVEL JOINT U2 U inelastico (cm) (cm.) / he RESULTADO


SEMISOTANO 338 8.00 E-04 0.41 0.41 0.0015 PASA
1 PISO 338 2.50 E-04 1.31 0.90 0.0034 PASA
2 PISO 338 4.80 E-03 2.53 1.22 0.0046 PASA
3 PISO 338 7.50 E-03 3.95 1.42 0.0054 PASA
4 PISO 338 1.04 E-03 5.46 1.51 0.0057 PASA
5 PISO 338 1.34 E-03 7.08 1.62 0.0062 PASA
6 PISO 338 1.64 E-03 8.62 1.54 0.0059 PASA
7 PISO 338 1.94 E-03 10.18 1.56 0.0060 PASA
8 PISO 338 2.24 E-02 11.75 1.57 0.0060 PASA
AZOTEA 338 2.52 E-02 13.23 1.18 0.0056 PASA

JUNTA SISMICA S(formula) = 3+0.004(h-500) = 10.09


S (min) = 3.0
2/3 ( Dmax + Dvec.)
S = 11.07

ENTONCES 2/3 x Dmax = 7.86


S/2 = 5.05

El edificio se retirara : 8.00

Potrebbero piacerti anche