Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
2 Introduction
7 Some Specs
To Be Able to Identify Opportunities for 84C and Customize your Selling Strategy
84CF
84CW Flanged
Wafer
Where?
Saturated steam is the most common source of thermal energy in virtually every industry we serve. It is
also common in heating of many public buildings such as Universities, Hospitals, Municipal Buildings
Why?
To minimize energy costs
To reduce energy usage be more Green
Internal and external billing
Where is the need?
Some have no measurement or just monitor the pressure and must do better
Some still have old mechanical meters that are no longer supported
Some use dP flow and may be open to better measurements
Some use vortex and may be interest in our Best in Class vortex offering
Mechanical counter
1234567
Pain points
Poor accuracy
Maintenance generally old and
in disrepair
No longer supported
More difficult to transmit signals
Not mass or energy based
Shunt Steam Flow Meter
Cost of ownership can be high
Likely no longer meet corporate
requirements
Flow
computer Pain points
Poor range to deal with seasonal
dP
variations
Poor accuracy
Increased maintenance
temp
or pressure Multiple pipe penetrations, leak
points
Cost of ownership can be high
May no longer meet corporate
requirements
Flow
computer
Volume
Flow
Pain points
Higher up front costs
temp
or More complexity with multiple
pressure
instruments
May require higher skill set to
implement and operate
Multiple potential leak points
Model 84C
Equals
Pros
Low up front costs
MASS &
ENERGY DirectSense integrated sensor
USAGE
High Accuracy and wide range
to handle seasonal load changes
No moving parts to wear
One process penetration
Simple commissioning and start
up
Best in Class!!!
- Easily replaceable
Sizes:
thru 12 Flanged / DN15 thru DN300
thru 8 Wafer / DN15 thru DN200
Potential payback.Months
Not to mention
Improved visibility of energy use
Reduced maintenance costs
VS
Lead With
Reduced Maintenance Costs
Fewer parts
Wider Range / higher accuracy
Complete engineered solution with 84C
Fewer process penetrations
Attractive ROI
VS
Lead With
Reduced Maintenance Costs
Fewer parts
Fewer process penetrations
Complete engineered solution with 84C
Best in Class Accuracy
ROI should focus on maintenance, fewer
parts, and engineered solution
4-20 mA
Pulse/ Frequency
Digital HART
Value?
Value?
The 84C allows you to program this straight line to provide a mass flow measurement
for any liquid that a vortex flow meter will work on!!!
PSS 1-8A8A
Battlecard
FAQ
Sales Brief
Sales Guide
Banner
ROI Calculator
Presentations
Website: www.flowexpertpro.com
Accuracy: 0.5% liquid ; 1.0% gas and steam Best in class accuracy: 1.4% mass sat. Steam
Flanged or Wafer end-connection Flanged or Wafer end-connection
3/4 - 12"; DN15 to DN300
Applications Applications
Oil & Gas
Gas, Liquid, or Steam applications Oil & Gas Steam injection
Chemical Chemical Utility & process steam distribution
De-ionized water
Semi-con P&P Coriolis alternative