Sei sulla pagina 1di 2

Project Jakarta MRT CP-103

Specification Class of Concrete = 40 MPA


Slump on Site = 12 mm (With Tolerance 2 mm)

Design Calculation
1. Determination of Slump & Compressive Concrete Averages Plan
a. Slump : 122 mm
b. Kuat Tekan Rata-Rata Rencana :

f'cr = f'c + 1,34 s ..(1) Proporsi campuran berdasarkan


f'cr = 0.9f'c + 2.33 s ..(2) pengalaman dilapangan
f'cr = f'c + 9.66 ..(3) Proporsi campuran di lab.
0.9

maka yang digunakan :


f'cr = f'c + 9.66
0.9
= 40 + 9.66
0.9
= 55.18 MPA

2. Coarse Aggregate Maximum

f'cr < 62.1 MPA Coarse Aggregate Maximum =


f'cr > 62.1 MPA Coarse Aggregate Maximum =

f'cr = 55.18 MPA


So, Coarse Aggregate Maximum = 25 mm

3. Optimum Levels of Coarse Aggregate


Coarse Aggregate Maximum = 25 mm

Table 1. The Volume Fraction of Coarse Aggregate Suggested

So, Optimum Levels of Coarse Aggregate = 0.75