PICTUS 700
FULLY AUTOMATIC RANDOM ACCESS CLINICAL CHEMISTRY
ANALYZER, END POINT, KINETICS, INMUNOTURBIDIMETRY,
COAGULATION, ISE, QUALITY CONTROL
SPECIFICATIONS
Throughput REAGENTS
Up to 500 tests/hour double reagent, up to 600 tests/hour Maximum number of simultaneous tests: 36 double to 72 single reagent
mono reagent, max. 700 tests/hour with oponal ISE unit tests + 3 with oponal ISE unit
1 to 3 reagents, 2 to 500 l/tests each (in increments of 1 l)
nal total soluon volume 180 to 500 l/test.
Analysis Modes Reagent boles capacies: 72 cooled posions
End point with sample or reagent blank BCR for reagents
Factor or standard
Priority selecon by sample (prole) or by reagent (batch) Reacon
Calibraon curve with up to 10 standards
Automac curve t Water consumpon: 3 L / hour
Turbodimetry Warm air incubator: room, 30 oC an 37 oC
Fast and two-point kinecs (zero and rst order) Reacion cuvee: re-usable plasc 6 mm path light cuvees
Roune, batch, STAT, proles Reacon me: 0 to 10 min.
Reacon temperature 37 oC 0.1 oC
PICTUS 700
Enzymes. Drugs
Automac sample diluon on abnormal levels, excessive Srring: Aer dispensing each reagent
substrate consumpon and/or lack of linearity
Full quality control: Levy-Jennings plots , Westgard mulrules Opcal System
Import/export data, methods and historic le Double beam system
Automac backup procedure Photometric Range: 0.1 to 3.6 A
Test selecon, automac calibraon, calibraon curve, Measuring wavelenght: 340 to 800 nm
mulpoint calibraon, polygonal (selectable among 12 wavelength)
Serum indices: sample blank compensaon, calculated tests Photometry Single or Double-wavelenght simultaneous reading
Quality control, auto re-run, prozone check, record of calibraon,
data storage (historic results) ISE Unit
Automac pre-diluon and post diluon (rao 1:5 to 1:100)
Na+, K+ and CI measurements, Samples: serum or urine.
Stat: Highest priority in operaon
Other electrodes on request
Connuous sample load
Decontaminang post-wash
Data Management
Sampling and Reagent WindowsTM based soware
Interface LIMS: bi-direconal RC 232C,
SAMPLES
according to ASTM 1394 requirements
Sample volume: 2 to 100 I/tests (in incremensts of 0.2 I)
Sample tray: 95 (5 racks x 19 posions) ID bar code equipped
posions for roune, stat and control samples and standard Printout
soluons Customers opmized (Analisys results, work list, serums list,
Primary tube (length up to 100 mm) Quality Control, Calibraon curves, etc.)
Pediatric vial UP TO 600 TESTS/HOUR WITHOUT ISE
Power requirements
110/220 V, 50/60 Hz, 2.0 kVA
72 REAGENT POSITIONS
Diatron reserves the right to change any of the specications without prior notice.
PICTUS
FULLY AUTOMATIC
700
RANDOM ACCESS CLINICAL CHEMISTRY ANALYZER
Reagent Tray
72 simultaneous single reagent channels or 24 double
reagent plus 24 single channels
Independent cooling system for overnight,
unattended operation even with instrument turned off
Laser Barcode reader
Accepts any code system in use
24 hour non stop cooling