3500.00
3000.00
2500.00
2000.00
Heat flux, 1500.00
1000.00
500.00
0.00
62.00 64.00 66.00 68.00
Tsat - Tsurf
(a)
50.00
40.00
30.00
Heat Transfer Coefficient, U
20.00
10.00
0.00
60.00 65.00 70.00
Tsat-Tsurf
(b)
Figure 4.1: Graph of (a) Heat flux and (b) heat transfer coefficient against
600000.00
500000.00
400000.00
200000.00
100000.00
0.00
60.00 62.00 64.00 66.00 68.00
Tsat-Tsurf
(a)
12000.00
10000.00
8000.00
4000.00
2000.00
0.00
60.0065.0070.00
Tsat-Tsurf
(b)
Figure 4.2: Graph of (a) Heat flux and (b) heat transfer coefficient against
increases with the temperature difference between the saturated steam and the
condenser surface. Similarly, the heat transfer coefficient also increases with the
the temperature of the surface of the condenser and the saturated surrounding
air differ greatly, transfer of heat is done faster. Referring to both the graph of
heat flux and heat transfer coefficient, the same trend can be observed as they
increase with the temperature difference (T saturated - Tsurface). This is expected due
550000.00
55000.00
Flimwise
Heat flux
Linear (Flimwise)
5500.00 Dropwise
Linear (Dropwise)
550.00
60.00 62.00 64.00 66.00 68.00
Tsat-Tsurf
Figure 4.3: Graph of heat flux against temperature difference (Tsat-Tsurf) for
1000.00
Filmwise
Heat Transfer Coefficient
Linear (Filmwise)
100.00 Dropwise
Linear (Dropwise)
10.00
60.00 65.00 70.00
Tsat-Tsurf
RECOMMENDATIO
As shown in Figure 4.3, the values for heat flux are far higher in
of about twenty times larger than that in filmwise. The vapour droplets in
the surface. They will then be released, which means that the surface of the
condensation, a laminar film is created where it always covers the surface of the
vapour is picked up along the way. This film is relatively a poor conductor of
heat, where it creates a thermal resistance and thus gives lower values of heat
Recommendation
some errors. It is predicted that one of the error is due to the fluid medium
involves in the condensation unit. The impurities content of the fluid medium
might affect its density and boiling temperature. Thus, condensation might have
occurred at a less precise order and led to the inaccurate data. Therefore,
that can be practised are avoid parallax error while taking reading and allow the
cooling water to flow at the end of the experiment before the equipment is shut
Conclusion
CONCLUSION
In conclusion, at constant pressure, dropwise condensation propose
continuous exposure of its surface to the surrounding, thus allowing higher heat
flux. This is the contrast to filmwise condensation, where at the same condition,
condensation.
Reference
Retrieved from:
http://www.p-a-hilton.co.uk/products/H102K-Film-and-Dropwise-Condensation.