IM
Interface Technology
in Modular Housings
Interface Technology in Modular Housings IM Series
Functions and selection guide
Depending on the devices scope of func- With a universal power supply ranging Removable terminal blocks simplify instal-
tions, there are housings with a width of from 20250 VUC, or 20250 VAC/ lation and device replacements significant-
18 or 27 mm, while they are 104 mm high. 20125 VDC for the intrinsically safe ly. The terminals are coded, thus preventing
All modules may be mounted directly next versions, the new IM-modules may be interchange errors.
to each other and can be powered via the connected to practically all industrial pow-
power bus. er networks. The universal power supply fa-
cilitates device selection, as well as device
and spare parts inventory management.
ATEX compliance
Hans Turck GmbH & Co. KG|45466 Mlheim an der Ruhr, Germany|T +49 208 4952-0|F +49 208 4952-264|more@turck.com|www.turck.com
Isolating amplifiers Rotational speed monitors/Frequency-current Analog data transmitters/intrinsically safe input
Processing of switching states of mechanical converters isolators
contacts and sensors according to EN 60947-5-6 Rotation speed monitoring for overspeed/un- Galvanic isolation and/or conversion of analog
(NAMUR). derspeed and window function, operating range current and voltage signals. There are devices with
between 0.06600000/min intrinsically safe input and output circuits.
P
I
P
I
HART
Isolating transducers Temperature measuring amplifiers Analog data transmitters/intrinsically safe output
Supply and transmission of current signals of Linear conversion of temperature values into isolators
2-wire transmitters located in explosion hazard- standard current signals. Linear conversion of Galvanic isolation and transfer of analog current
ous areas. HART devices enable bi-directional temperature values, which are detected by a signals into the explosion hazardous area. The
communication. This range incorporates devices thermo-element, into standard current signals. All family comprises a selection of devices with intrin-
with and without auxiliary power and active or customary thermo-elements or mV-signals may be sically safe output circuits. HART devices enable
passive outputs. Series-FSD includes smoke and connected. Types -Ci, -CRi = programmable via PC bi-directional communication.
fire detectors. using software PACTware.
2015|11 2 |3
Type IM1-12Ex-R IM1-12Ex-T IM1-12-T IM1-22Ex-R IM1-22-R IM1-22Ex-T
[ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ]
Function Isolating switching Isolating switching Isolating switching Isolating switching Isolating switching Isolating switching
amplifier amplifier amplifier amplifier amplifier amplifier
Voltage 20250 VAC 20250 VAC 20250 VAC 20250 VAC 20250 VAC 20250 VAC
supply 20125 VDC 20125 VDC 20125 VDC 20125 VDC 20125 VDC 20125 VDC
Inputs 1 Namur sensor or 1 Namur sensor or 1 Namur sensor or 2 Namur sensors or 2 Namur sensors or 2 NAMUR sensors or
contacts contacts contacts contacts contacts contacts
Outputs 2 x relays (N.O.) 2 transistors 2 x transistors 2 x relays (N.O.) 2 x relays (N.O.) 2 x transistors
30 V, 50 mA, 5 30 V, 50 mA,
KHz 5 KHz
Approvals ATEX, IECEx, UL, ATEX, IECEx, UL, TR CU ATEX, IECEx, UL, TR CU ATEX, IECEx, UL,
cFMus, CSA, TR CU, FMus, CSA, TR CU, cFMus, CSA, TR CU, cFMus, CSA, TR CU,
NEPSI, KOSHA, TIIS, NEPSI, KOSHA, TIIS, NEPSI, KOSHA, TIIS, NEPSI, KOSHA, TIIS,
CCOE CCOE CCOE CCOE
Special SIL 2, mounting in SIL 2, mounting in SIL 2 SIL 2, mounting in SIL 2 SIL 2, mounting in
features zone 2 possible zone 2 possible zone 2 possible zone 2 possible
Isolating amplifiers
Hans Turck GmbH & Co. KG|45466 Mlheim an der Ruhr, Germany|T +49 208 4952-0|F +49 208 4952-264|more@turck.com|www.turck.com
IM1-22Ex-MT IM1-121Ex-R IM1-231Ex-R IM1-451Ex-R IM1-451-R IM1-451Ex-T
[ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ]
Isolating switching Isolating switching Isolating switching Isolating switching Isolating switching Isolating switching
amplifier amplifier amplifier amplifier amplifier amplifier
20250 VAC 20250 VAC 20...250 VAC 20250 VAC 250 VUC 20250 VAC
20125 VDC 20125 VDC 20...125 VDC 20125 VDC 20125 VDC
2 Namur sensors or 1 Namur sensor or 2 Namur sensors or 4 NAMUR sensors or 4 NAMUR sensors or 4 Namur sensors or
contacts contacts contacts contacts contacts contacts
2 MOSFETS 2 relays (N.O.) incl. 2 relays (change-over) 5 Relais (N.O.) incl. 5 Relais (N.O.) incl. 5 transistors, incl.
250 VAC 1 alarm output additionally 1 alarm 1 alarm output 1 alarm output 1 alarm output
output (N.O.)
ATEX, IECEx, UL, cFMus, ATEX, IECEx, UL, cFMus, ATEX, IECEx, TR CU, ATEX, IECEx, UL, cFMus, TR CU ATEX, IECEx, UL,cFMus,
CSA, TR CU, NEPSI, CSA, TR CU, NEPSI, INMETRO CSA, TR CU, INMETRO, CSA, TR CU,INMETRO,
KOSHA, TIIS, CCOE KOSHA, TIIS, CCOE TIIS TIIS
Mounting in zone 2 SIL 2, mounting in zone Mounting in zone 2 Mounting in zone 2 Mounting in zone 2
possible 2 possible possible possible possible
2015|11 4 |5
Type IM1-451-T IM12-22Ex-R IM12-22ExR/24VDC IM12-22ExR-230VAC IM21-14Ex-CDTRi IM21-14-CDTRi
[ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ]
Function Isolating switching Isolating switching Isolating switching Isolating switching Speed monitor/Freq.- Speed monitor/Freq.-
amplifier amplifier amplifier amplifier current converter current converter
Voltage 20250VAC 20250 VAC 1030 VDC 196253 VAC 20250 VAC 250 VUC
supply 20250VDC 20125 VDC 20125 VDC
Inputs 4 NAMUR sensors or 2 NAMUR sensors or 2 NAMUR sensors or 2 NAMUR sensors or 1 NAMUR 1 Namur or 3-wire
contacts contacts contacts contacts sensors, 530 VDC
Outputs 5 transistors, incl. 2 x relays (N.O.) 2 x relays (N.O.) 2 x relays (N.O.) 2 x relays (N.O.) 2 x relays (N.O.)
1 alarm output 1 transistor 1 x 1 transistor 1 x
0/420 mA 0/420 mA
Approvals TR CU ATEX, IECEx, UL, ATEX, cFMus, TR CU ATEX, cFMus, TR CU ATEX, IECEx, TR CU
cFMus, CSA, cFMus, TR CU, NEPSI,
TR CU, NEPSI, TIIS, KOSHA
KOSHA, TIIS, CCOE
Special Mounting in zone 2 Signal multiplier Signal multiplier Display, programma- Display, programma-
features possible ble via PC (FDT/DTM), ble via PC (FDT/DTM)
mounting in zone 2
possible
Analog data transmitters/Intrinsically safe input isolators
Galvanic isolation and/or conversion of analog current and voltage signals. There are
devices with intrinsically safe input and output circuits.
Hans Turck GmbH & Co. KG|45466 Mlheim an der Ruhr, Germany|T +49 208 4952-0|F +49 208 4952-264|more@turck.com|www.turck.com
IM31-11Ex-i IM31-11-i IM31-12Ex-i IM31-12-i IM31-22Ex-U IM31-22-i
IM31-22Ex-i
[ Ex ia ] [ Ex ia ] [ Ex ia ]
Analog data transmitter Analog data transmitter Analog data transmitter Analog data transmitter Analog data transmitter Analog data transmitter
20250 VAC 250 VUC 20250 VAC 250 VUC 20250 VAC 250 VUC
20125 VDC 20125 VDC 20125 VDC
0/210 V 0/420 mA 0/210 V 0/420 mA 0/210 V 0/210 V 0/420 mA 2 x 0/210 V 2 x 0/210 V
0/420 mA 2 x 0/420 mA 2 x 0/420 mA
0/420 mA 1 x 0/420 mA 2 x 0/420 mA 2 x 0/420 mA 2 x 0/420 mA 2 x 0/420 mA
2 x 0/2...10 V
ATEX, IECEx, UL, cFMus, TR CU ATEX, IECEx, UL, cFMus, TR CU ATEX, IECEx, UL, cFMus, TR CU
TR CU, NEPSI TR CU, NEPSI TR CU, NEPSI
Isolating transducers
These devices are suited for the supply and transmission of current signals of 2-wire
transmitters located in explosion hazardous areas. HART devices enable bi-directional
communication. This range incorporates devices with and without auxiliary power and
active or passive outputs. Series-FSD includes smoke and fire detectors. FDT/DTM with
diagnostic function.
2015|11 6 |7
Type IM33-11Ex-Hi/24VDC IM33-12Ex-Hi/24VDC IM33-12-Hi/24VDC IM33-22Ex-Hi/24VDC IM33-22-Hi/24VDC IM33-11Ex-Hi
[ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ]
Function HART isolating HART isolating HART isolating HART isolating HART isolating HART isolating
transducer transducer transducer transducer transducer transducer
Voltage 24 VDC 24 VDC 1929 VDC 24 VDC 1929 VDC 20250 VAC
supply 20125 VDC
Inputs 0/420 mA 1 x 0/420 mA 1 x 0/420 mA 2 x 0/420 mA 1 x 0/420 mA 1 x 0/420 mA
Approvals ATEX, IECEx, UL, ATEX, IECEx, UL, TR CU ATEX, IECEx, UL, TR CU ATEX, IECEx, cFMus,
cFMus, TR CU, TIIS, cFMus, TR CU, TIIS, cFMus, TR CU, TIIS, TR CU, INMETRO
CCEO, KOSHA CCEO, KOSHA CCEO, KOSHA
Special HART transmis- HART transmis- HART transmission HART transmis- HART transmission HART transmis-
features sion possible/SIL 2, sion possible/SIL 2, possible sion possible/SIL 2, possible sion possible/SIL 2,
mounting in zone 2 mounting in zone 2 mounting in zone 2 mounting in zone 2
possible possible possible possible
Hans Turck GmbH & Co. KG|45466 Mlheim an der Ruhr, Germany|T +49 208 4952-0|F +49 208 4952-264|more@turck.com|www.turck.com
IM33-12Ex-Hi IM33-22Ex-Hi IM33-14Ex-CDRi IM33-FSD-Ex/L IM34-11Ex-i IM34-11Ex-Ci
[ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ]
HART isolating HART isolating Transmitter power sup- Isolating transducer Temperature measuring Temperature measuring
transducer transducer ply with trip amplifier amplifier amplifier
20250 VAC 20250 VAC 20250 VAC Without auxiliary energy 20250 VAC 20250 VAC
20125 VDC 20125 VDC 20125 VDC 20125 VDC 20125 VDC
1 x 0/420 mA 2 x 0/420 mA 0/420 mA oder 2 x 020 mA Ni/Pt100 or thermo-ele- Ni/Pt100 or thermo-ele-
0/210 V oder ments or mV-input ments or mV-input
transmitter
2 x 0/420 mA 2 x 0/420 mA 1 x 0/420 mA, 2 x 020 mA 1 x 0/420 mA 1 x 0/420 mA
3 Relais
(Schlieer)
ATEX, IECEx, cFMus, TR ATEX, IECEx, cFMus, TR ATEX, IECEx, ATEX, cFMus, TR CU ATEX, IECEx, cFMus, UL, ATEX, IECEx, cFMus, UL,
CU, INMETRO CU, INMETRO TR CU TR CU, INMETRO, CCOE TR CU, INMETRO, CCOE
HART transmission pos- HART transmission pos- Display, programma- Transducer for fire and Mounting in zone 2 Programmable via PC
sible/SIL 2, mounting in sible/SIL 2, mounting in ble via PC (FDT/DTM), smoke indicators possible (FDT/DTM), mounting in
zone 2 possible zone 2 possible mounting in zone 2 zone 2 possible
possible
2015|11 8 |9
Type IM34-11Ex-Ci/24VDC IM34-11-Ci IM34-12Ex-Ri IM34-12Ex-CRi IM34-14Ex-CDRi IM35-11Ex-Hi/24VDC
[ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ]
Function Temperature Temperature Temperature Temperature Temperature HART Analog data
measuring amplifier measuring amplifier measuring amplifier measuring amplifier measuring amplifier transmitter
Voltage 2030 VDC 20250 VAC 20250 VAC 20250 VAC 20250 VAC 24 VDC
supply 20125 VDC 20125 VDC 20125 VDC 20125 VDC
Inputs Ni/Pt100 or Ni/Pt100 or Ni/Pt100 or Ni/Pt100 or thermo- Ni/Pt100 or thermo- 0/420 mA
thermo-elements or thermo-elements or thermo-elements or elements or mV-input elements or mV-input
mV-input mV-input mV-input
Outputs 1 x 0/420 mA 1 x 0/420 mA 1 x 0/420 mA, 1 x 0/420 mA, 3 relays 0/420 mA
1 relays (N.O.) 1 relays (N.O.) (N.O.)
1 x 0/420 mA)
Approvals ATEX, IECEx, TR CU, TR CU ATEX, IECEx, cFMus, ATEX, IECEx, cFMus, ATEX, IECEx, cFMus, ATEX, IECEx, UL,
INMETRO, CCOE UL, TR CU, INMETRO, UL, TR CU, INMETRO, TIIS, KOSHA cFMus, TR CU
CCOE CCOE
Special Mounting in zone 2 Mounting in zone 2 Programmable via PC Display, programma- HART transmission
features possible possible (FDT/DTM), mounting ble via PC (FDT/DTM), possible, mounting in
in zone 2 possible mounting in zone 2 zone 2 possible
possible
Potentiometer amplifiers
Hans Turck GmbH & Co. KG|45466 Mlheim an der Ruhr, Germany|T +49 208 4952-0|F +49 208 4952-264|more@turck.com|www.turck.com
IM35-11-Hi/24VDC IM35-11Ex-Hi IM35-22Ex-Hi/24VDC IM35-22Ex-Hi IM36-22Ex-I IM36-11Ex-i/24VDC
[ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ]
HART Analog data HART Analog data HART Analog data HART Analog data Potentiometer Potentiometer
transmitter transmitter transmitterr transmitter amplifier amplifier
24 VDC 20250 VAC 24 VDC 20250 VAC 20250 VAC 24 VDC
20125 VDC 20125 VDC 20125 VDC
0/420 mA 1 x 0/420 mA 2 x 0/420 mA 2 x 0/420 mA 800 bis 100 k 800 bis 20 k
HART transmission HART transmission HART transmission pos- HART transmission Mounting in zone 2
possible possible, mounting in sible/SIL 2, mounting in possible, mounting in possible
zone 2 possible zone 2 possible zone 2 possible
Monitoring of standard current and voltage signals relative to pre-set limit values. This
series includes devices with three limit values and versions with current output. Types
-SR and -SRi = a manual teach function, Types -R and -Ri = adjustable via a coded rotary
switch Typ -CDRi: programmable via FDT/DTM with diagnostic function HART transparent
2015|11 10 |11
Type IM36-22Ex-U IM36-11Ex-U/24VDC IM43-13-R IM43-13-SR IM43-14-Ri IM43-14-CDRi
[ Ex ia ] [ Ex ia ]
Function Potentiometer Potentiometer Limit value monitor Limit value monitor Limit value monitor Limit value monitor
amplifier amplifier
Voltage 20250 VAC 24 VDC 20250 VUC 20250 VUC 20250 VUC 20250 VUC
supply 20125 VDC
Inputs 800 bis 100 k 800 bis 20 k 0/420 mA or 0/420 mA or 0/420 mA or 0/420 mA or
0/210 V or 0/210 V or 0/210 V or 0/210 V or
transmitter transmitter transmitter transmitter
Outputs 010 V 010 V 3 relays (N.O.) 3 relays (N.O.) 3 relays (N.O.), 3 relays (N.O.)
1 x 0/420 mA 1 x 0/420 mA
Approvals ATEX, IECEx, TR CU ATEX, TR CU cFMus, TR CU cFMus, TR CU cFMus, TR CU TR CU
Special Mounting in zone 2 Setting of limit values Manual teach Setting of limit values Display, programma-
features possible via rotary coding function via rotary coding ble via PC (FDT/DTM
switch switch
Hans Turck GmbH & Co. KG|45466 Mlheim an der Ruhr, Germany|T +49 208 4952-0|F +49 208 4952-264|more@turck.com|www.turck.com
IM72-11Ex/L-24VDC IM72-22Ex/L-VDC IM73-12-R IM73-22Ex-R/24VUC
[ Ex ia ] [ Ex ia ] [ Ex ia ]
Valve control module Valve control module Relay coupler Relay coupler
Without power supply Without power supply Without auxiliary energy 1030 VUC
Coupling devices
2015|11 12 |13
Typ IM82-24-2,5 IM82-24-5,0 IM82-24-10 IM82-24-20
Voltage 85264 VAC, 90132 VAC, 90132 VAC, 186264 VAC, 90264 VAC, 120370 VDC
supply 90375 VDC 186264 VAC, 210370 VDC
210370 VDC
Outputs 24 V/2,5 A 24 V/5 A 24 V/10 A 24 V/20 A
Approvals UL UL UL
Power supplies
The IM82-24 switching power supplies provide safety extra-low voltage (SELV) acc. to
EN 60950. They supply electrical equipment as well as IM, IME, IMS and IMC interface
modules with 24 VDC.
Hans Turck GmbH & Co. KG|45466 Mlheim an der Ruhr, Germany|T +49 208 4952-0|F +49 208 4952-264|more@turck.com|www.turck.com
IM82-24-5,0-3P IM82-24-10-3P
24 V/5 A 24 V/10 A
UL UL
Class 1 Class 1
Div 2 Div 2
2015|11 14 |15