V-Series

Contura Switches
Product Highlights:
Maximum sealing protection with dual seals around lamps
and rocker stem, certified to IP66 & IP68. Optional panel
seals for additional protection.
Silver plated butt contact mechanism provides 50 to
100 thousand electrical cycles and a variety of different
CONTURA III CONTURA II
electrical ratings.
Roller pin mechanism does not require lubricants and
allows the switch to withstand extreme temperatures.
The switch base accommodates up to 10 terminals and a
large variety of switch and lighting circuits.
The multi-step mounting wings provide a secure fit for
panel thicknesses of 0.032 thru 0.250 in an industry
standard 0.830 x 1.450 mounting hole.
The switch connector allows the user to preload FQC
CONTURA V CONTURA VII
terminals for easy assembly to switch base.
Numerous choices of removable rockers allow for style
change without having to retest or re-qualify the switch Carling Technologies sealed V-Series Contura switches are
base. well known for their cutting edge design, high quality,
Illumination options are endless with bar, oval, and square maximum performance and unmatched reliability. These
lenses available with choices of incandescent, neon and switches are a staple in the marine and transportation
a wide variety of LEDs including superbrite, megabrite, industries and have passed a range of environmental,
flashing and bicolor lighting. corrosion, temperature, vibration, shock and sealing tests
Available with a variety of complimentary mounting including MIL Std 202F, MIL Std 810C, UL 1500, ISO 8846, IEC
panels, hole plugs, illuminated indicators and boots to 60529 and BS 5490 among others, making them one of the
accommodate most any design need. most rugged and reliable switches ever manufactured.

Carling Technologies, Inc.


60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com
Application Support: team2@carlingtech.com
Phone: (860) 793-9281 Fax: (860) 793-9231
www.carlingtech.com
2 | V-Series Contura Sealed Rocker Switches

V-Series Switch
DESIGN FEATURES

INTERCHANGEABLE ACTUATORS DUAL SEAL PROTECTION CLEAN CONNECTIONS


Panel redesign is a snap with our wide Seals out water, dust, Options for both eight and ten
range of rocker styles. Achieve maximum debris, and enables switch terminal base styles with AMP &
design variety with minimum inventory. certification to IP66/IP68 for Packard compatible connectors
Simply swap rockers to create an entirely front panel components. affords myriad circuit options
new look for your panel. while providing ease of assembly.

OPTIONAL PANEL SEAL MULTIPLE LIGHTING OPTIONS BRASS ROLLER PIN SILVER PLATED BUTT
Prevents water/dust In addition to incandescent Robust mechanism CONTACT MECHANISM
ingress behind panel. lamps, our LED illumination is eliminates the need for Providing 50K to 100K
offered in a wide array of light lubricants. Enables switch electrical cycles and
intensities, colors, as well as to withstand -40C to a variety of different
dual level, tri-color, and flashing +85C temperatures. electrical ratings.
options.

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
V-Series Contura Sealed Rocker Switches & Illuminated Plug | 3

Contura II & III Contura X


The Contura II & III actuators are The raised bracket/bezel on
constructed of thermoplastic the Contura X helps prevent
polycarbonate and are offered inadvertent actuation of the
with a hard nylon overlay or a rocker, as well as preventing
soft-touch elastomer overlay. debris from being trapped under
These models incorporate the actuator. This curved rocker
aesthetic designs on the top and style is available with a variety of
bottom of the rocker featuring lenses and legends.
two rows of raised bumps on the
Contura II and three indented
lines on the Contura III.

Contura IV Contura XI
The Contura IVs Shape to create The raised bracket/bezel on
a Shape actuator works with the the Contura XI helps prevent
curves, contours & advanced inadvertent actuation of the
styling of the latest panel designs, rocker, as well as preventing debris
flowing with these advanced from being trapped under the
curves & radii. This actuator style actuator. This convex style rocker
fits on the Contura flush bracket/ is available with a wide variety of
bezel. lenses and legends.

Contura V Contura XII


The symmetrically curved The Contura XII version features
Contura V actuator provides a paddle style actuator with
the perfect complement to the the raised bracket/bezel of
Contura IVs Shape to create a Contura X and XI. The contoured
Shape design concept. With its handle design provides intuitive
flush style mounting bracket, recognition and ease of operation
Contura V can be mounted in and is available with all Contura X
between two Contura IVs, by and XI lens and legend offerings.
itself, or in groups.

Contura VI (WAVE) Contura XIV


The Contura VI WAVE sealed The Contura XIV represents a sleek
rocker switches, when used in a new crossover rocker design which
row, create an uniquely appealing should appeal to Trucks, Buses and
wave design on your panel. A Heavy Vehicles as well as the Marine
variety of colors and finishes are Industry. Intuitive feel is provided by
available for both rocker and wave recessed ridges along with a Center
insert. Contura VI features bar and Groove which effectively defines the
oval lenses. boundary between top and bottom
switch functions.

Contura VII V-Series Illuminated


Contura VII featuring gently Indicators & Accessories
curved corners and edges Alert operator of systems functions
assuring compatibility with most or malfunctions, are offered with
any panel design. Intuitive feel removable/replaceable lamps in
is maximized by the use of 2 Contura II, II, V or X styles. Accessories
embossed circular pads located at include connectors, mounting
opposite ends of the rocker. Any panels, hole plugs, panel seals, and
combination of Bar or Oval style actuator removal tools. Refer to
lenses can be located in the pads accessories page for full details
providing a truly unique look,
exclusive to Contura VII.

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
4 | VSeries Contura Sealed Rocker Switches - General Specifications

Electrical Agency Certifications


Contact Rating .4VA @ 24VDC (MAX) resistive
15 amps, 125VAC
10 amps, 250VAC
1/2 HP 125-250VAC Environmental
20 amps, 4-14VDC Sealing Sealed version: IP68, in accordance
15 amps, 15-28VDC with IEC 60529, BS 5490, DIN 40050
10A, 14VT & NFC 20 010. This rating applies to
6A, 125VAC L front panel components of the actual
Dielectric Strength 1500 Volts RMS switch only, and signifies protection
Insulation Resistance 50 Megohms against dust and the prolonged
Initial Contact Resistance 10 milliohms max. @ 4VDC effects of immersion under pressure.
The standard test for immersion
Life 50,000- 100,000 cycles circuit
under pressure requires submersion
dependent under one meter of water for 30 min.
Contacts Silver alloy, silver tin-oxide, fine The V-Series switch has exceeded
silver these parameters, having
Terminals Brass or copper/silver plate 1/4 been actuated and illuminated during
(6.3mm) Quick Connect submersion.
terminations standard. Solder lug, Corrosion Mixed Flowing Gas (MFG) Class III
Wire Lead 3 year accelerated exposure per
ASTM B-827, B-845 Silver and gold
Mechanical contacts
Endurance 150,000 cycles minimum Operating Temp. -40C to +85C
circuit dependent Vibration 1 Per Mil-Std 202F, Method 204D
Test Condition A 0.06 DA or 10Gs
Physical 10-500 Hz. Tested with VCH connector.
Lighted Incandescent - rated 10,000 Test criteria - No loss of circuit during
hours Neon - rated 25,000 hours test, pre and post test contact
LED - rated 100,000 hours 1/2 life resistance.
(LED is internally ballasted for Vibration 2 Resonance search
voltages to 24VDC) 24-50 Hz 0.40 DA
50-2000 Hz 10 Gs peak
Seals Internal
Horizontal Axis 3-5 Gs max.
Optional external gasket panel seal Random
Base Polyester blend rated to 125C with 24 Hz 0.06 PSD-Gsq/Hz
a UL flammability rating of 94V0. 60 Hz 0.50
Contura II,III,IV,V, Hard Surface: Basic actuator 100 Hz 0.50
VI, VII Actuator structure molded of thermoplastic 200 Hz 0.025
polycarbonate with a hard Nylon 66 2000 Hz 0.025
thermoplastic surface overlay. No loss of circuit during test; <10
Soft Surface: Basic actuator structure seconds chatter.
molded of thermoplastic polycarbonate Shock Per Mil-Std 202F, Method 213B, Test
Condition K @ 30Gs. Tested with
with an elastomer overlay.
VCH connector. Test criteria - No loss
Contura X,XI,XII Actuator,VP Nylon 66 Reinforced rated to 105C of circuit during test, pre and post
Lens Polycarbonate rated at 100C test contact resistance.
Contura XIV Polycarbonate lens/subrocker with Salt Spray Per Mil-Std 202F, Method 101D, Test
ABS shell Condition A, 96 Hrs. Sealed version only.
Dust Per Mil-Std 810C, Method 510.2 Air
Actuator Travel (Angular Displacement) Velocity 300 200 Feet/Min, Test
2 position 18 Duration 16 Hrs.
3 positions 9 from center Thermal Shock Per Mil-Std 202F, Method 107F, Test
Cond. A, -55C to +85C. Test criteria -
Mounting Specifications pre and post test contact resistance
Moisture Resistance Per Mil-Std 202F, Method 106F, Test
Panel Thickness Range .830[21.08]
Criteria - pre and post test contact
Gaskets Acceptable Panel Thickness resistance
0 .030 to .250 (.76mm to 6.35mm) TEST CUT
Ignition Protection All Contura switches with sealed
1 .030 to .109 & .147 to .157 1.450[36.83] HOLE IN
ACTUAL construction meet the requirements
(.76 to 2.77mm & 3.73 to 3.98mm)
MATERIAL
of UL1500/ISO8846 for ignition
Recommended: No gasket with panel protection, in addition to
thickness of .032, .062, .093, .125,.187 or .250 SWITCH conformance with EC directive
MOUNTING HOLE 94/25/EC for marine products.

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
VSeries Contura II, III, & IV | 5

DimensionalSpecifications: in. [mm]

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
6 | V-Series Contura V, VI & VII

DimensionalSpecifications: in. [mm]

CONTURA V CONTURA V CONTURA VI CONTURA VII


SHOWN WITH SHOWN WITH SHOWN WITH OVAL SHOWN WITH LARGE LENS
BAR LENS LOW PROFILE LOCK LENS AND BAR LENS

1.922 [48.56] 1.922 [48.56] .080[2.03] 1.950 [49.53] 1.922 [48.82]

1.079 1.126
[27.40] 1.479 [28.60]
1.550
[37.57]
[39.37]

10 TERMINAL BASE
8 TERMINAL BASE 8 TERMINAL BASE W/BARRIER AND 10 TERMINAL BASE
W/BARRIERS W/O BARRIERS LAMP TERMINAL W/O BARRIERS

1.020 1.020 1.000 0.985


[25.91] [25.91] [25.40] [25.02]

.505 .505
[12.83] [12.83]

.250
.250 .250 [6.35] .250 [6.35]
[6.35] [6.35] X .031 [.78]
X X .031
.031 .031 [.78]
.820
[.78] [.78] .820 [20.83]
[20.83]
.390 .820 .960
[9.90] [20.83] .960 [24.38]
[24.38]
.960 .960
[24.38] [24.38]

8 TERMINAL BASE 8 TERMINAL BASE 10 TERMINAL BASE 10 TERMINAL BASE


W/BARRIERS W/O BARRIERS W/O BARRIERS W/O BARRIERS

8 7 8 7
2.029 1 4 1 4
[51.53] 2 5
2 5
3 6 3 6
10 9

SWITCH SHOWN WITH BOTTOM VIEW BOTTOM VIEW


VCH CONNECTOR 8 TERMINAL TERMINAL SWITCH SHOWN WITH
TERMINAL ARRANGEMENT ARRANGEMENT VC1 CONNECTOR 10 SWITCH SHOWN
8 TERMINAL BASE 10 TERMINAL BASE TERMINAL WITH VC1
CONNECTOR 10
TERMINAL

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
V-Series Contura X, XI, XII & XIV | 7

DimensionalSpecifications: in. [mm]

CONTURA X CONTURA XI CONTURA XII CONTURA XIV


SHOWN WITH RAISED BRACKET SHOWN WITH RAISED SHOWN WITH PADDLE SHOWN WITH LARGE LENS
BRACKET AND TWO SQUARE ACTUATOR
LENSES

1.928 [48.97]
.350 1.910 [48.51] .667 [16.94]
[8.89] 1.910 [48.51] .426 [10.82]
1.305 [33.15] .573
[14.56]

.350
1.586 [8.89] 1.506
[40.28] [38.25]

1.370 [34.79] 1.370 [34.79] 1.370 [34.79]

8 TERMINAL BASE 10 TERMINAL BASE 8 TERMINAL BASE 10 TERMINAL BASE


W/BARRIERS W/O BARRIERS W/O BARRIERS W/O BARRIERS

.960 [24.38] .970


.960 [24.38] .960 [24.38] [24.64]
.780 [19.81]
.780 [19.81]
.780 [19.81]

.250 [6.35]
X
.031[.78]

.390 [9.90] .390 [9.90] .390 [9.90]


.820
.820 [20.82] .820 [20.82] .820 [20.82] [20.83]
.960
[24.38]
8 TERMINAL BASE 10 TERMINAL BASE 10 TERMINAL
W/BARRIERS W/BARRIERS BASE
W/O BARRIERS

8 7 8 7
1 4 1 4
2 5 2 5

3 6 3 6
10 9

SWITCH SHOWN WITH BOTTOM VIEW BOTTOM VIEW SWITCHES SHOWN WITH
VCH CONNECTOR TERMINAL TERMINAL VC1 CONNECTOR
8 TERMINAL ARRANGEMENT ARRANGEMENT
8 TERMINAL BASE 10 TERMINAL BASE 10 TERMINAL

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
8 | V-Series Contura II to XIV - Circuit Diagram

CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM


3 3 6 1 3 4 6

1 A J
2 2 5 2 5

3 3 6 1 3 4 6

2 B K
2 2 5 2 5

3 3 6 1 3 4 6

3 C L
2 2 5 2 5

1 3 1 3 4 6 3 6

4 D M
2 2 5 2 5

1 3 1 3 4 6 1 3 6

5 E R
2 2 5 2 5

1 3 1 3 4 6 1 3 6

6 F S
2 2 5 2 5

1 3 3 6

7 G SYMBOL LEGEND
SYM. DEFINITION

2 2 5 DESIGNATES TERMINALS AND CONTACTS


DESIGNATES LAMP LOCATION
1 3 3 4 DESIGNATES MAINTAINED CIRCUITS
DESIGNATES OTHER POSITION

8 H DESIGNATES MOMENTARY CIRCUITS


DESIGNATES TWO POSITION CONNECTION
DESIGNATES EXTERNAL JUMPER PROVIDED
2 2 5 BY CUSTOMER

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
V-Series Contura II to XIV - Circuit Diagram | 9

LAMP LAMP LAMP LAMP


CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM

+8 +8 +3 -6 +3 -6 +3 +6

A/1 1 F/6 1 2 L/9 1 SPECIAL 1 2


#1

-7 -7 -7

+3 +8 +3 +3 -6 +8 +6

SPECIAL 1 2
B/2 1 G/7 1 2 M/R 2
#3

-7 -7 -7

+3 +8 +1 +3 -4 -6 +8 +3

SPECIAL 1 2
C/3 2 H/Z 2 N/T 1 2
#4

-7 -7 -7

+1 +3 -8 +3 +6 +1 +3 -4 -6

D/4 1 2 J/8 1 2 P/V 1 2

-7 -7

+1 +3 +8 +6 +8 +10

E/5 1 2 K/W 1 2 U/Y 1 2

-7 (-)7 -7 -9

CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM


CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM
1 3 17 18 10(-) 10(-) 1 3 17 18 11 13 3 14 6 NOTE:
1 3 17 18 10(-) 10(-) 1 3 17 18 13 11 3 14 6 J circuits are available for
all non-locking V-Series
J1 1 J5 2 JA
styles. Consult factory for
J1 1 J5 2 JA p /n details.
2 5 8 2 5 8 5
2 5 8 2 5 8 5
11 13 3 14 17 18 10(-) 11 13 3 14
13 11 3 14 17 18 10(-) 13 11 3 14
J2 1 JJ
J2 1 JJ

5 8
5 8
1 3 17 18 10(-) 11 13 3 14 15 12 6 16
1 3 17 18 10(-) 1311 3 14 15 12 6 16
J3 1 JK
J3 1 JK
2 5 8
2 5 8
1 3 17 18 10(-)
1 3 17 18 10(-) SYMBOL LEGEND
SYM.
J4 1 SYMBOL LEGENDDEFINITION CIRCUIT CONNECTOR PART #
DESIGNATES TERMINALS AND CONTACTS
J4 1 SYM. DEFINITION JA,JJ,JK JC1-01
DESIGNATES LAMP LOCATION
DESIGNATES TERMINALS AND CONTACTS J1,J3,J4,J5 JC2-01
2 5
DESIGNATES LAMP LOCATION J2 JC3-01
2 5 DESIGNATES TWO POSITION CIRCUIT

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
10 | V-Series Contura II & III Sealed Rocker Switches - Ordering Scheme

V 1 D A B T 0 B A R B 00 0 00
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Color Legend Legend Actuator
Orientation Lens Legend

1 SERIES 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)


V Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
2 CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
Terminal Connections as viewed ( ) - momentary LED* superbright superbright
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. Red Amber Green Red
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 2VDC A L F R
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 6VDC B M G S
1 - - 4 1 - - 4 12VDC C N H T
2 - - 5 2 - - 5 24VDC D P J V
3 - - 6 3 - - 6 * Consult factory for daylight bright LED options. Typical current draw for LED is 20ma.
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF 8 FLUSH BRACKET COLOR1, PANEL SEAL
2 B (ON) NONE OFF Black White Gray
3 C ON NONE (OFF)
4 D ON NONE ON No Seal B W G
5 F ON NONE (ON) One Seal C Y H
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON) 9 ACTUATOR
SPECIAL CIRCUITS 0 No Actuator
H* 2 & 3 2 & 3, 5 & 4 5&4
G* 2 & 3, 5 & 6 2 & 3 OFF A, B Contura II
S* 2 & 3, 5 & 6 2 & 3 1&2 C, D Contura III
M* (2 & 3, 5 & 6) 2 & 3 OFF
3,6 1,4
R* (2 & 3, 5 & 6) 2 & 3 2&1 Actuator orientation above terminals:
E* 5 & 6 5 & 3 5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit. 10 LENS
0 - No Actuator Z - No Lens
Clear White Amber Green Red Blue
3
3 RATING 1 6 8 G M T
1 .4VA @ 28VDC Resistive 2 7 C H N U
B 15A 24V
C 20A 18V 3 8 D J P V
D 20A 12V 4 9 E K R W
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 5 A F L S Y
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V Lens color for LEDs must be clear, white, or match color of LED.
N .4VA/15A 24V Green or blue lenses are not recommended with Neon lamps.

4 TERMINATION/BASE STYLE 11 ACTUATOR COLOR1 AND TEXTURE


8 term 10 Term Termination Jumper 0 - No Actuator
1 2 .250 TAB (QC) no barriers No Black Gray Red White
A B .250 TAB (QC) with barriers No
Soft Surface B G R W
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No Hard Surface C H S Y
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No 12 ACTUATOR LENS OR BODY LEGENDS2
Note: Codes J & K for circuits H, G & M. 11 ON 12 OFF 13 I 14 O
OFF ON O I
5 ILLUMINATION 15 O O 16 O O 17 O I 18 I O
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of F N N F
switch. Positive (+) and negative (-) symbols apply to LED lamps only F F
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals For additional legend options & codes, visit us at www.carlingtech.com.
S 0 NONE
A 1 1 INDEPENDENT 8 (+) 7 ()
B 2 1 DOWN 3 (+) 7 () 13 LEGEND ORIENTATION
C 3 2 UP 3 (+) 7 () 0 No legend (used with codes 11-18 in selection 12)
D 4 1 DOWN 3 (+) 7 () 1 Orientation 1
2 DOWN 1 (+) 7 () 2 Orientation 2
E 5 1 UP 1 (+) 7 () 3 Orientation 3
2 UP 3 (+) 7 () 4 Orientation 4
F 6 1 INDEPENDENT 8 (+) 7 ()
2 UP 3 (+) 6 ()
G 7 1 INDEPENDENT 8 (+) 7 ()
2 UP 3 (+) 7 ()
H Z 2 INDEPENDENT 8 (+) 7 ()
U Y 1 INDEPENDENT 8 (+) 7 ()
2 INDEPENDENT 10 (+) 9 ()
SINGLE POLE SWITCHES ONLY 14 ACTUATOR LENS LEGEND
J 8 1 DOWN 3 (+) 8 () 00 No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
2 INDEPENDENT 6 (+) 7 () legends. If the two legends consist of one lens and one body legend, lens legend must
K W 1 INDEPENDENT 8 (+) 7 () be specified in selection 12; body legend specified in selection 14.
2 INDEPENDENT 6 (+) 7 () For legend options & codes, visit us at www.carlingtech.com.
DOUBLE POLE SWITCHES ONLY
L 9 1 DOWN 3 (+) 6 () Notes:
M R 1 UP 3 (+) 6 () Consult factory to verify horsepower rating for your particular circuit choice.
N T 1 DOWN 3 (+) 6 () 1 Custom colors are available. Consult factory.
2 DOWN 1 (+) 4 () 2 Body legends not available on Soft surface actuators; White imprinting is standard
P V 1 UP 1 (+) 4 () on black actuators; Black imprinting is standard on white, red and gray actuators.
2 UP 3 (+) 6 () Custom colors are available, consult factory.
3 Additional ratings available.See V-Series Switch Accessories page.
4 Contura II available with two square lenses. Consult factory for details.

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
V-Series Contura II & III Locking Sealed Rocker Switches - Ordering Scheme | 11

V 1 D A S W 0 B A Z E 00 0
1 2 3 4 5 6 7 8 9 10 11 12 13
Series Circuit Rating Termination Illumination Lock Lamp Bracket Actuator Lens Function Legend Legend
Orientation

1 SERIES 7 LAMP
V Lamp above terminals 3 & 6 end of switch
No lamp 0
Neon 1 125VAC 2 250VAC
2 CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
Terminal Connections as viewed ( ) - momentary LED* superbright superbright
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. Red Amber Green Red
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 2VDC A L F R
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 6VDC B M G S
1 - - 4 1 - - 4 12VDC C N H T
2 - - 5 2 - - 5 24VDC D P J V
3 - - 6 3 - - 6 * Consult factory for daylight bright LED options. Typical current draw for LED is 20ma.
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF 8 FLUSH BRACKET COLOR1, PANEL SEAL
4 D ON NONE ON Black White Gray
5 F ON NONE (ON)
6 J ON OFF ON No Seal B W G
7 K ON OFF (ON) One Seal C Y H
8 L (ON) OFF (ON)
9 N OFF NONE ON
SPECIAL CIRCUITS 9 HARD SURFACE ACTUATOR1
H* 2 & 3 2 & 3, 5 & 4 5&4 Black Gray Red White
G* 2 & 3, 5 & 6 2 & 3 OFF Contura II A B G H
S* 2 & 3, 5 & 6 2 & 3 1&2
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2&1 Contura III C D E F
E* 5 & 6 5 & 3 5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. Actuator orientation above terminals: 3,6 1,4
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
10 LENS
Z - No Lens
4 Clear White Amber Green Red Blue
3 RATING 3 8 D J P V
1 .4VA @ 28VDC Resistive
B 15A 24V
Lens color for LEDs must be clear, white, or match color of LED.
C 20A 18V
Green or blue lenses are not recommended with Neon lamps.
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V 11 ACTUATOR LOCK FUNCTION AND COLOR1
N .4VA/15A 24V Lock Color Up Down Up & Down Center3
Match Actuator A H R 1
Black B J S 2
4 TERMINATION/BASE STYLE White C K T 3
8 term 10 Term Termination Jumper Red D L V 4
1 2 .250 TAB (QC) no barriers No Safety Orange E M W 5
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No 12 ACTUATOR LENS OR BODY LEGEND2
C D Solder Lug No 00 - No Legend
5 6 Wire Leads no barriers No
E F Wire Leads No 21 22 23 24
Note: Codes J & K for circuits H, G & M. OFF ON O I
25 O 26 O 27 O 28 I
F N
5 ILLUMINATION & SWITCH SEALING F
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of For additional legend options & codes, visit us at www.carlingtech.com.
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE ORIENTATION OF

13 LEGEND ORIENTATION
ACTUATOR/LENS IN PANEL

C 3 2 UP 3 (+) 7 () ORIENTATION 1

H Z 2 INDEPENDENT 8 (+) 7 () 0 No legend (used with codes 21-28 in selection 12)


DOUBLE POLE SWITCHES ONLY 1 Orientation 1
M R 1 UP 3 (+) 6 () 2 Orientation 2
3 Orientation 3
4 Orientation 4
ORIENTATION 4 ORIENTATION 2

6 LOCK
AZC45-1

AZC45-2

Lock above terminals 1 & 4 end of switch.


45

W lock 45 ORIENTATION 3

Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators. Custom colors are available, consult factory.
3 Only available with 3 position circuits. Center OFF and special circuits only available
with center position lock function.
4 Additional ratings available.See V-Series Switch Accessories page.

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
12 | V-Series Contura IV Sealed Rocker Switches - Ordering Scheme

V 1 D A B T 0 B E P C 00 0 00
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Color Legend Legend Actuator
Orientation Lens Legend

1 SERIES 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)


V Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
2 CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
Terminal Connections as viewed ( ) - momentary
LED* superbright superbright
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. Red Amber Green Red
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 2VDC A L F R
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 6VDC B M G S
1 - - 4 1 - - 4 12VDC C N H T
2 - - 5 2 - - 5 24VDC D P J V
3 - - 6 3 - - 6 * Consult factory for daylight bright LED options. Typical current draw for LED is 20ma.
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF 8 FLUSH BRACKET COLOR1, PANEL SEAL
2 B (ON) NONE OFF Black White Gray
3 C ON NONE (OFF) No Seal B W G
4 D ON NONE ON
5 F ON NONE (ON) One Seal C Y H
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON) 9 ACTUATOR 1,4
SPECIAL CIRCUITS 0 No Actuator
H* 2 & 3 2 & 3, 5 & 4 5&4 E Contura IV, left orientation
G* 2 & 3, 5 & 6 2 & 3 OFF T Contura IV, left orientation, laser etched
S* 2 & 3, 5 & 6 2 & 3 1&2
M* (2 & 3, 5 & 6) 2 & 3 OFF F Contura IV, right orientation
R* (2 & 3, 5 & 6) 2 & 3 2&1 R Contura IV, right orientation, laser etched
E* 5 & 6 5 & 3 5&1 Actuator orientation above terminals: 3,6
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit. 10 LENS
0 - No Actuator Z - No Lens
Clear White Amber Green Red Blue
3 RATING4 1 6 8 G M T
1 .4VA @ 28VDC Resistive 2 7 C H N U
B 15A 24V 3 8 D J P V
C 20A 18V
4 9 E K R W
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 5 A F L S Y
EF
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V Lens color for LEDs must be clear, white, or match color of LED.
N .4VA/15A 24V Green or blue lenses are not recommended with Neon lamps.

4 TERMINATION/BASE STYLE 11 ACTUATOR COLOR1,5,6


8 term 10 Term Termination Jumper No Actuator 0 Black C Gray H Red S White Y Nickel D Pewter E
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No 12 ACTUATOR LENS OR BODY LEGENDS2
C D Solder Lug No 11 ON 12 OFF 13 I 14 O
5 6 Wire Leads no barriers No OFF ON O I
E F Wire Leads No
Note: Codes J & K for circuits H, G & M. 15 O O 16 O O 17 O I 18 I O
F N N F
F F
5 ILLUMINATION & SWITCH SEALING For additional legend options & codes, visit us at www.carlingtech.com.
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed
ORIENTATION OF

Lamps Illumination Type Lamp wired to Terminals 13 LEGEND ORIENTATION


ACTUATOR/LENS IN PANEL

S 0 NONE
ORIENTATION 1

0 No legend (used with codes 11-18 in selection 12)


A 1 1 INDEPENDENT 8 (+) 7 () 1 Orientation 1
B 2 1 DOWN 3 (+) 7 () 2 Orientation 2
C 3 2 UP 3 (+) 7 () 3 Orientation 3
D 4 1 DOWN 3 (+) 7 () 4 Orientation 4 ORIENTATION 4 ORIENTATION 2

2 DOWN 1 (+) 7 () E8C45-100 E3C70-200 E8C45-300

E 5 1 UP 1 (+) 7 ()
2 UP 3 (+) 7 ()
F 6 1 INDEPENDENT 8 (+) 7 ()
2 UP 3 (+) 6 () F8C45-100 F3C70-200 F8C45-300 ORIENTATION 3

G 7 1 INDEPENDENT 8 (+) 7 ()
2 UP 3 (+) 7 ()
H Z 2 INDEPENDENT 8 (+) 7 ()
U Y 1 INDEPENDENT 8 (+) 7 ()
14 ACTUATOR LENS LEGEND
00 No legend this location / no actuator
2 INDEPENDENT 10 (+) 9 () (used with codes 11-18 in selection 12) Selection 14 required when switch requires two
SINGLE POLE SWITCHES ONLY legends. If the two legends consist of one lens and one body legend, lens legend must
J 8 1 DOWN 3 (+) 8 () be specified in selection 12; body legend specified in selection 14.
2 INDEPENDENT 6 (+) 7 () For legend options & codes, visit us at www.carlingtech.com.
K W 1 INDEPENDENT 8 (+) 7 ()
2 INDEPENDENT 6 (+) 7 () Notes:
DOUBLE POLE SWITCHES ONLY Consult factory to verify horsepower rating for your particular circuit choice.
L 9 1 DOWN 3 (+) 6 () 1 Custom colors are available. Consult factory.
M R 1 UP 3 (+) 6 () 2 White imprinting is standard on black actuators; Black imprinting is standard on white,
N T 1 DOWN 3 (+) 6 () red and gray actuators. Custom colors are available, consult factory.
2 DOWN 1 (+) 4 () 3 Gloss brow is on left side of E actuator and right side of F actuator.
P V 1 UP 1 (+) 4 () 4 Additional ratings available.See V-Series Switch Accessories page.
2 UP 3 (+) 6 () 5 Laser etched rocker only available with lens code Z & actuator colors black,
nickel or pewter.
6 Pewter and nickel colors only available with laser etched actuator.

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
V-Series Contura V Sealed Rocker Switches - Ordering Scheme | 13

V 1 D A B T 0 B G P C 00 0 00
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Color Legend Legend Actuator
Orientation Lens Legend

1 SERIES 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)


V Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
2 CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
Terminal Connections as viewed ( ) - momentary
LED* superbright superbright
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. Red Amber Green Red
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 2VDC A L F R
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 6VDC B M G S
1 - - 4 1 - - 4 12VDC C N H T
2 - - 5 2 - - 5 24VDC D P J V
3 - - 6 3 - - 6 * Consult factory for daylight bright LED options. Typical current draw for LED is 20ma.
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF 8 FLUSH BRACKET COLOR1, PANEL SEAL
2 B (ON) NONE OFF Black White Gray
3 C ON NONE (OFF) No Seal B W G
4 D ON NONE ON
5 F ON NONE (ON) One Seal C Y H
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON) 9 ACTUATOR
SPECIAL CIRCUITS 0 No Actuator
H* 2 & 3 2 & 3, 5 & 4 5&4 G Contura V
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1&2 P Contura V, laser etched
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2&1
E* 5 & 6 5 & 3 5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. 10 Lens
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit 0 - No Actuator Z - No Lens
E may be used for SP OFF-ON-ON circuit. Clear White Amber Green Red Blue
1 6 8 G M T bar
2 7 C H N U bar/bar
3 RATING4 3 8 D J P V oval
1 .4VA @ 28VDC Resistive
B 15A 24V 4 9 E K R W oval/bar
C 20A 18V 5 A F L S Y oval/oval
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) Lens color for LEDs must be clear, white, or match color of LED.
F 10A 14V, 6A 14VT (circuit G only) Green or blue lenses are not recommended with Neon lamps.
M .4VA/20A 12V
N .4VA/15A 24V
11 ACTUATOR COLOR1,3,3
No Actuator 0 Black C Gray H Red S White Y Nickel D Pewter E
4 TERMINATION/BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No 12 ACTUATOR LENS OR BODY LEGENDS2,6
J K .250 TAB (QC) no barriers Yes T2 to 5 11 ON 12 OFF 13 I 14 O
3 5 Solder Lug no barriers No OFF ON O I
C D Solder Lug No
5 6 Wire Leads no barriers No 15 O O 16 O O 17 O I 18 I O
E F Wire Leads No F N N F
Note: Codes J & K for circuits H, G & M. F F
For additional legend options & codes, visit us at www.carlingtech.com.

5 ILLUMINATION & SWITCH SEALING ORIENTATION OF


Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of 13 LEGEND ORIENTATION ACTUATOR/LENS IN PANEL

switch. Positive (+) and negative (-) symbols apply to LED lamps only
ORIENTATION 1
0 No legend (used with codes 11-18 in selection 12)
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals 1 Orientation 1
S 0 NONE 2 Orientation 2
A 1 1 INDEPENDENT 8 (+) 7 () 3 Orientation 3
B 2 1 DOWN 3 (+) 7 () 4 Orientation 4
C 3 2 UP 3 (+) 7 () 4G13L

D 4 1 DOWN 3 (+) 7 () MC
4G
MA 4G
ORIENTATION 4 ORIENTATION 2

2 DOWN 1 (+) 7 ()
E 5 1 UP 1 (+) 7 () MA MC 3L
4G200
2 UP 3 (+) 7 () MA3MC MA1MC ORIENTATION 3

F 6 1 INDEPENDENT 8 (+) 7 ()
2 UP 3 (+) 6 ()
G 7 1 INDEPENDENT 8 (+) 7 () 14 ACTUATOR LENS LEGEND
2 UP 3 (+) 7 () 00 No legend this location / no actuator
H Z 2 INDEPENDENT 8 (+) 7 () (used with codes 11-18 in selection 12) Selection 14 required when switch requires two
U Y 1 INDEPENDENT 8 (+) 7 () legends. If the two legends consist of one lens and one body legend, lens legend must
2 INDEPENDENT 10 (+) 9 () be specified in selection 12; body legend specified in selection 14.
SINGLE POLE SWITCHES ONLY For legend options & codes, visit us at www.carlingtech.com.
J 8 1 DOWN 3 (+) 8 ()
2 INDEPENDENT 6 (+) 7 () Notes:
K W 1 INDEPENDENT 8 (+) 7 () Consult factory to verify horsepower rating for your particular circuit choice.
2 INDEPENDENT 6 (+) 7 () 1 Custom colors are available. Consult factory.
DOUBLE POLE SWITCHES ONLY 2 White imprinting is standard on black actuators; Black imprinting is standard on
L 9 1 DOWN 3 (+) 6 () white, red and gray actuators. Custom colors are available, consult factory.
M R 1 UP 3 (+) 6 () 3 Laser Etched rocker only available with lens code Z & actuator colors black,
N T 1 DOWN 3 (+) 6 () nickel or pewter.
2 DOWN 1 (+) 4 () 4 Additional ratings available.See V-Series Switch Accessories page.
P V 1 UP 1 (+) 4 () 5 Nickel and Pewter colors only available with laser etched actuator.
2 UP 3 (+) 6 () 6 Consult factory for laser etched lens callout.

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
14 | V-Series Contura IV & V Locking Sealed Rocker Switches - Ordering Scheme

V 1 D A S W 0 B J Z E 00 0
1 2 3 4 5 6 7 8 9 10 11 12 13
Series Circuit Rating Termination Illumination Lock Lamp Bracket Actuator Lens Function Legend Legend
Orientation

1 SERIES 7 LAMP
V Lamp above terminals 3 & 6 end of switch
No lamp 0
Neon 1 125VAC 2 250VAC
2 CIRCUIT3 Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
Terminal Connections as viewed ( ) - momentary LED* superbright superbright
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. Red Amber Green Red
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 2VDC A L F R
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 6VDC B M G S
1 - - 4 1 - - 4 12VDC C N H T
2 - - 5 2 - - 5 24VDC D P J V
3 - - 6 3 - - 6 * Consult factory for daylight bright LED options. Typical current draw for LED is 20ma.
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF 8 FLUSH BRACKET COLOR1, PANEL SEAL
4 D ON NONE ON Black White Gray
6 J ON OFF ON
7 K ON OFF (ON) No Seal B W G
8 L (ON) OFF (ON) One Seal C Y H
9 N OFF NONE ON

9 HARD SURFACE ACTUATOR


3 RATING4 CONTURA IV:
1 .4VA @ 28VDC Resistive Orientation Black Gray Red White
B 15A 24V Left J K L M
C 20A 18V Right N P R S
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) CONTURAV: Actuator orientation above terminals: 3,6 1,4
F 10A 14V, 6A 14VT (circuit G only) Orientation Black Gray Red White
M .4VA/20A 12V U V W Y
N .4VA/15A 24V
Actuator orientation above terminals: 3,6 1,4

4 TERMINATION/BASE STYLE
8 term 10 Term Termination Jumper 10 LENS5
1 2 .250 TAB (QC) no barriers No
Z - No Lens
A B .250 TAB (QC) with barriers No
Clear White Amber Green Red Blue
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No A B C D E F bar lens
C D Solder Lug No G H J K L M oval lens
5 6 Wire Leads no barriers No
E F Wire Leads No Lens color for LEDs must be clear, white, or match color of LED.
Note: Codes J & K for circuits H, G & M. Green or blue lenses are not recommended with Neon lamps.

5 ILLUMINATION & SWITCH SEALING 11 ACTUATOR LOCK FUNCTION AND COLOR1


Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only Lock Color Up Down Up & Down Center3
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals Match Actuator A H R 1
S 0 NONE Black B J S 2
C 3 2 UP 3 (+) 7 () White C K T 3
H Z 2 INDEPENDENT 8 (+) 7 () Red D L V 4
DOUBLE POLE SWITCHES ONLY Safety Orange E M W 5
M R 1 UP 3 (+) 6 () Gray F G N 6

6 LOCK 12 ACTUATOR LENS OR BODY LEGEND2


Lock above terminals 1 & 4 end of switch. 00 - No Legend
W low profile lock Y6 high profile lock 21 22 23 24
OFF ON O I
Notes:
Consult factory to verify horsepower rating for your particular circuit choice. 25 O 26 O 27 O 28 I
1 Custom colors are available. Consult factory. F N
2 White imprinting is standard on black actuators; Black imprinting is standard on white, F
red and gray actuators. Custom colors are available, consult factory. For additional legend options & codes, visit us at www.carlingtech.com.
3 Only available with 3 position circuits. Center OFF and special circuits only available
with center position lock function.
4 Additional ratings available.See V-Series Switch Accessories page.
ORIENTATION OF

13 LEGEND ORIENTATION
ACTUATOR/LENS IN PANEL

5 Located at T3-6 end of switch.


ORIENTATION 1

0 No legend
6 Contura V style only.
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
ORIENTATION 4

ORIENTATION 2

JHAY3-100 JHAY3-200 JHAY3-300

P P

P P
P

ORIENTATION 3
NHAY3-100 NHAY3-200 NHAY3-300

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
V-Series Contura VI WAVE Sealed Rocker Switches - Ordering Scheme | 15

V 1 D B G N T B H A 7 C B AC 1 00
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Lens Color Insert Actuator Legend Actuator
Color Lens Orientation Lens Legend

1 SERIES 7 LAMP
V Lamp above terminals 3 & 6 end of switch
No lamp 0
Neon 1 125VAC 2 250VAC
2 CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
Terminal Connections as viewed ( ) - momentary LED* superbright superbright
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. Red Amber Green Red
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 2VDC A L F R
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 6VDC B M G S
1 - - 4 1 - - 4 12VDC C N H T
2 - - 5 2 - - 5 24VDC D P J V
3 - - 6 3 - - 6 * Consult factory for daylight bright LED options. Typical current draw for LED is 20ma.
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF 8 FLUSH BRACKET COLOR1, PANEL SEAL
2 B (ON) NONE OFF Black White Gray
3 C ON NONE (OFF)
4 D ON NONE ON No Seal B W G
5 F ON NONE (ON) One Seal C Y H
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON) 9 ACTUATOR
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5&4 0 No Actuator H High Insert L Low Insert
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1&2
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2&1 10,11 LENS4
E* 5 & 6 5 & 3 5&1 0 - No Actuator Z - No Lens
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. Clear White Amber Green Red Blue
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit. 7 C H N U Bar Lens Translucent
3 D J P V Bar Lens Transparent
4 E K R W Oval Lens Transparent
3 RATING3 A F L S Y Oval Lens Translucent
1 .4VA @ 28VDC Resistive
B 15A 24V Lens color for LEDs must be clear, white, or match color of LED.
C 20A 18V Green or blue lenses are not recommended with Neon lamps.
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V
12 ACTUATOR COLOR
N .4VA/15A 24V C Black H Gray S Red Y White

4 TERMINATION/BASE STYLE 13 INSERT COLOR N Bright Nickel Plated


8 term 10 Term Termination Jumper B Black S Satin Chrome Plated
1 2 .250 TAB (QC) no barriers No C Bright Chrome Plated T Satin Nickel Plated
A B .250 TAB (QC) with barriers No D Satin Chrome Painted W White
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No
C D Solder Lug No 14 ACTUATOR LENS OR BODY LEGENDS2
5 6 Wire Leads no barriers No 00 - No Legend this location/No actuator
E F Wire Leads No
11 ON 12 OFF 13 I 14 O
Note: Codes J & K for circuits H, G & M.
OFF ON O I
15 O O 16 O O 17 O I 18 I O
5 ILLUMINATION & SWITCH SEALING F N N F
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of F F
switch. Positive (+) and negative (-) symbols apply to LED lamps only For additional legend options & codes, visit us at www.carlingtech.com.
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE
A 1 1 INDEPENDENT 8 (+) 7 () Orientation

15 LEGEND ORIENTATION
1

B 2 1 DOWN 3 (+) 7 ()
C 3 2 UP 3 (+) 7 () 0 No legend (used with codes 11-18 in selection 12)
D 4 1 DOWN 3 (+) 7 () 1 Orientation 1
2 DOWN 1 (+) 7 () 2 Orientation 2
3 Orientation 3
Orientation

Orientation

E 5 1 UP 1 (+) 7 ()
4 Orientation 4
4

2 UP 3 (+) 7 () VTHAACN-MC1MC VTHWZCB-45146 VTHA7CN-3M100

F 6 1 INDEPENDENT 8 (+) 7 ()
2 UP 3 (+) 6 ()
G 7 1 INDEPENDENT 8 (+) 7 ()
2 UP 3 (+) 7 () Orientation

H Z 2 INDEPENDENT 8 (+) 7 () VTLSZSC-70100 VTLLFHC-A813H VTLDECC-001MG 3

U Y 1 INDEPENDENT 8 (+) 7 ()
2 INDEPENDENT 10 (+) 9 ()
SINGLE POLE SWITCHES ONLY 16 ACTUATOR LENS LEGEND
J 8 1 DOWN 3 (+) 8 () 00 No legend this location / no actuator
2 INDEPENDENT 6 (+) 7 () (used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
K W 1 INDEPENDENT 8 (+) 7 () be specified in selection 12; body legend specified in selection 14.
2 INDEPENDENT 6 (+) 7 () For legend options & codes, visit us at www.carlingtech.com.
DOUBLE POLE SWITCHES ONLY
L 9 1 DOWN 3 (+) 6 () Notes:
M R 1 UP 3 (+) 6 () Consult factory to verify horsepower rating for your particular circuit choice.
N T 1 DOWN 3 (+) 6 () 1 Custom colors are available. Consult factory.
2 DOWN 1 (+) 4 () 2 White imprinting is standard on black actuators. Black imprinting is standard on white,
P V 1 UP 1 (+) 4 () red and gray actuators. Custom colors are available, consult factory.
2 UP 3 (+) 6 () 3 Additional ratings available.See V-Series Switch Accessories page.

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
16 | V-Series Contura VII Sealed Rocker Switches - Ordering Scheme

V 1 D A B T 0 B Z R C 00 0 00
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Color Legend Legend Actuator
Orientation Lens Legend

1 SERIES 6,7 LAMP (same coding for both selections)


V Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
2 CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
Terminal Connections as viewed ( ) - momentary LED* superbright superbright
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. Red Amber Green Red
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 2VDC A L F R
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 6VDC B M G S
1 - - 4 1 - - 4 12VDC C N H T
2 - - 5 2 - - 5 24VDC D P J V
3 - - 6 3 - - 6 * Consult factory for daylight bright LED options. Typical current draw for LED is 20ma.
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF 8 FLUSH BRACKET COLOR1, PANEL SEAL
2 B (ON) NONE OFF Black White Gray
3 C ON NONE (OFF) No Seal B W G
4 D ON NONE ON One Seal C Y H
5 F ON NONE (ON)
6 J ON OFF ON
7 K ON OFF (ON) ACTUATOR
8 L (ON) OFF (ON) 9 ACTUATOR ORENTATION

0
ABOVE TERMINALS
SPECIAL CIRCUITS No Actuator 3,6 1,4
H* 2 & 3 2 & 3, 5 & 4 5&4 Z Contura VII
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1&2
STANDARD

M* (2 & 3, 5 & 6) 2 & 3 OFF


R* (2 & 3, 5 & 6) 2 & 3 2&1
E* 5 & 6 5 & 3 5&1 10 LENS
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. Lens color for LEDs must be clear, white, or match color of LED.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit Green or blue lenses are not recommended with Neon lamps.
E may be used for SP OFF-ON-ON circuit.
0 - No Actuator Z - No Lens
White Amber Green Red Blue Lens style & location
3 RATING4 6 B G M T
1 .4VA @ 28VDC Resistive
B 15A 24V 7 C H N U
C 20A 18V 8 D J P V
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 9 E K R W
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V A F L S Y
N .4VA/15A 24V 1 2 3 4 5
ORIENTATION 3

4 TERMINATION/BASE STYLE
8 term 10 Term Termination Jumper 11 ACTUATOR COLOR/THUMB PRINT COLOR1
1 2 .250 TAB (QC) no barriers No O N/A - No Actuator C Black/Black
ORIENTATION 2

ORIENTATION 4
A B .250 TAB (QC) with barriers No H Grey/Black S Red/Black
J K .250 TAB (QC) no barriers Yes T2 to 5 Y White/Black
3 5 Solder Lug no barriers No
C D Solder Lug No ORIENTATION 2
5 6 Wire Leads no barriers No 14 ACTUATOR LENS OR BODY LEGENDS2
E F Wire Leads No 11 ON 12 OFF 13 I 14 O
Note: Codes J & K for circuits H, G & M.
OFF ON O I
ORIENTATION 1

ORIENTATION 3
15 O O 16 O O 17 O I 18 I O ORIENTATION 1
5 ILLUMINATION & SWITCH SEALING F N N F
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of F F
switch. Positive (+) and negative (-) symbols apply to LED lamps only For additional legend options & codes, visit us at www.carlingtech.com.
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE
A 1 1 INDEPENDENT 8 (+) 7 () ORIENTATION 1
B 2 1 DOWN 3 (+) 7 () 13 LEGEND ORIENTATION ORIENTATION 4
C 3 2 UP 3 (+) 7 () 0 No legend (used with codes 11-18 in selection 12)
D 4 1 DOWN 3 (+) 7 () 1 Orientation 1
ORIENTATION 4

ORIENTATION 2

2 DOWN 1 (+) 7 () 2 Orientation 2


E 5 1 UP 1 (+) 7 () 3 Orientation 3
2 UP 3 (+) 7 () 4 Orientation 4
F 6 1 INDEPENDENT 8 (+) 7 () AA

2 UP 3 (+) 6 ()
G 7 1 INDEPENDENT 8 (+) 7 () 46 AA
2 UP 3 (+) 7 ()
46

ORIENTATION 3
H Z 2 INDEPENDENT 8 (+) 7 () 3AA-146 3AA-246

U Y 1 INDEPENDENT 8 (+) 7 ()
2 INDEPENDENT 10 (+) 9 ()
SINGLE POLE SWITCHES ONLY 14 ACTUATOR LENS LEGEND
J 8 1 DOWN 3 (+) 8 () 00 No legend this location / no actuator
2 INDEPENDENT 6 (+) 7 () (used with codes 11-18 in selection 12) Selection 14 required when switch requires two
K W 1 INDEPENDENT 8 (+) 7 () legends. If the two legends consist of one lens and one body legend, lens legend must
2 INDEPENDENT 6 (+) 7 () be specified in selection 12; body legend specified in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
DOUBLE POLE SWITCHES ONLY
L 9 1 DOWN 3 (+) 6 ()
M R 1 UP 3 (+) 6 () Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
N T 1 DOWN 3 (+) 6 ()
1 Custom colors are available. Consult factory.
2 DOWN 1 (+) 4 ()
2 White imprinting is standard on black actuators. Black imprinting is standard on white,
P V 1 UP 1 (+) 4 () red and gray actuators. Custom colors are available, consult factory.
2 UP 3 (+) 6 () 3 Additional ratings available.See V-Series Switch Accessories page.
4 Legends available for lighted oval lens version only

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
V-Series Contura X, XI & XII Sealed Rocker Switches - Ordering Scheme | 17

1
V 1 D A B 6 0 1
2 3 4 5 6 7 8 9
6 P Z 00 10 11 12 13
0 00 14
Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Lens Legend Legend Actuator
Orientation Lens Legend

1 SERIES 6,7 LAMP (same coding for both selections)


V Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
2 CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
Terminal Connections as viewed ( ) - momentary LED* superbright superbright
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. Red Amber Green Red
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 2VDC A L F R
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 6VDC B M G S
1 - - 4 1 - - 4
2 - - 5 2 - - 5 12VDC C N H T
3 - - 6 3 - - 6 24VDC D P J V
10 - - 9 * Consult factory for daylight bright LED options. Typical current draw for LED is 20ma.
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF 8 BRACKET COLOR1, PANEL SEAL (EXTERNAL FOAM GASKET)
2 B (ON) NONE OFF
3 C ON NONE (OFF) X & XI w/Flush Bracket X, XI, XII w/Raised Bracket
4 D ON NONE ON # of gaskets 0 1 2 0 1
5 F ON NONE (ON) Black B C D 1 4
6 J ON OFF ON White W Y Z 2 5
7 K ON OFF (ON) Gray G H J 3 6
8 L (ON) OFF (ON)
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5&4
G* 2 & 3, 5 & 6 2 & 3 OFF 9 ACTUATOR
S* 2 & 3, 5 & 6 2 & 3 1&2 No Actuator 0
M* (2 & 3, 5 & 6) 2 & 3 OFF Black Gray White Red
R* (2 & 3, 5 & 6) 2 & 3 2&1 Contura X 1 2 3 4
E* 5 & 6 5 & 3 5&1 Contura XI 6 7 8 9
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. Contura XII J K N M
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit Actuator orientation above terminals: 3,6 1,4
E may be used for SP OFF-ON-ON circuit.

3 RATING4 10 LENS - ABOVE LAMP #1 TERMINALS1,4


1 .4VA @ 28VDC Resistive 11 LENS - ABOVE LAMP #2 TERMINALS3,6
B 15A 24V 0 - No Actuator Z - No Lens
C 20A 18V Clear White Amber Green Red Blue Lens Style
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 3 8 D J P V Bar
F 10A 14V, 6A 14VT (circuit G only) 4 9 E K R W One piece Square
M .4VA/20A 12V 5 A F L S Y Two piece Square*
N .4VA/15A 24V
(w/ clear top protective lens)
2 7 C H N U Two piece Square*
4 TERMINATION/BASE STYLE
8 term 10 Term Termination Jumper (w/ smoke top protective lens)
1 2 .250 TAB (QC) no barriers No 1 6 B G M T Two piece Square*
A B .250 TAB (QC) with barriers No (w/ white top protective lens)
J K .250 TAB (QC) no barriers Yes T2 to 5 * All bottom lenses are molded of opaque material. Consult factory for other lens colors.
3 5 Solder Lug no barriers No Lens color for LEDs must be clear, white, or match color of LED.
C D Solder Lug No Green or blue lenses are not recommended with Neon lamps.
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M. 12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend this location/No actuator
11 ON 12 OFF 13 I 14 O
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of OFF ON O I
switch. Positive (+) and negative (-) symbols apply to LED lamps only
15 O O 16 O O 17 O I 18 I O
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE F N N F
A 1 1 INDEPENDENT 8 (+) 7 () F F
B 2 1 DOWN 3 (+) 7 () 21 22 23 24
C 3 2 UP 3 (+) 7 () OFF ON O I
D 4 1 DOWN 3 (+) 7 ()
2 DOWN 1 (+) 7 () 25 O 26 O 27 O 28 I
E 5 1 UP 1 (+) 7 () F N
2 UP 3 (+) 7 () F
F 6 1 INDEPENDENT 8 (+) 7 () For additional legend options & codes, visit us at www.carlingtech.com.
2 UP 3 (+) 6 ()
G 7 1 INDEPENDENT 8 (+) 7 ()
13 LEGEND ORIENTATION3
ORIENTATION OF
ACTUATOR/LENS IN PANEL

2 UP 3 (+) 7 () 0 No legend (used with codes 11-18 in selection 12)


ORIENTATION 1

H Z 2 INDEPENDENT 8 (+) 7 () 1 Orientation 1


U Y 1 INDEPENDENT 8 (+) 7 () 2 Orientation 2
2 INDEPENDENT 10 (+) 9 () 3 Orientation 3
ORIENTATION 4

ORIENTATION 2

SINGLE POLE SWITCHES ONLY 4 Orientation 4


J 8 1 DOWN 3 (+) 8 () 6ZZ3G-100

2 INDEPENDENT 6 (+) 7 () 3G MA
6FFMA-4MC
70

K W 1 INDEPENDENT 8 (+) 7 ()
G3
A7 MC

2 INDEPENDENT 6 (+) 7 () MA MC
ORIENTATION 3

DOUBLE POLE SWITCHES ONLY


6ZZ3G-1A7 6FFMA-3MC 6FZ70-100

L 9 1 DOWN 3 (+) 6 ()
M R 1 UP 3 (+) 6 () 14 ACTUATOR LENS LEGEND
N T 1 DOWN 3 (+) 6 () 00 No legend this location / no actuator
2 DOWN 1 (+) 4 () (used with codes 11-18 in selection 12) Selection 14 required when switch requires two
P V 1 UP 1 (+) 4 () legends. If the two legends consist of one lens and one body legend, lens legend must
2 UP 3 (+) 6 () be specified in selection 12; body legend specified in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white,
red & gray actuators. Custom colors are available, consult factory.
3 With 2 square lenses, use sel. 12 for lens above lamp 1, & selection 14 for lens above lamp 2.
4 Additional ratings available.See V-Series Switch Accessories page.
5 Not available with Contura XI rockers.

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
18 | V-Series Contura X Locking Sealed Rocker Switches - Ordering Scheme

V 1 D A S W 0 1 1 P B 00 0
1 2 3 4 5 6 7 8 9 10 11 12 13
Series Circuit Rating Termination Illumination Lock Lamp Bracket Actuator Lens Function Legend Legend
Orientation

1 SERIES 6,7 LAMP (same coding for both selections)


V Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
2 CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
Terminal Connections as viewed ( ) - momentary LED* superbright superbright
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. Red Amber Green Red
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 2VDC A L F R
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 6VDC B M G S
1 - - 4 1 - - 4 12VDC C N H T
2 - - 5 2 - - 5 24VDC D P J V
3 - - 6 3 - - 6 * Consult factory for daylight bright LED options. Typical current draw for LED is 20ma.
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF 8 FLUSH BRACKET COLOR1, PANEL SEAL
4 D ON NONE ON Black White Gray
6 J ON OFF ON No Gasket 1 2 3
9 N OFF NONE ON One Gasket 4 5 6
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5&4
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1&2 9 HARD SURFACE ACTUATOR
E* 5 & 6 5 & 3 5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. Contura X Black Grey Red White
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit 1 2 3 4
E may be used for SP OFF-ON-ON circuit.
Actuator orientation above terminals: 3,6 1,4

3 RATING4
1 .4VA @ 28VDC Resistive 10 LENS - ABOVE LAMP #2 TERMINALS5
B 15A 24V Z - No Lens
C 20A 18V Clear White Amber Green Red Blue Lens Style
D 20A 12V 3 8 D J P V Bar
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only) 4 9 E K R W One piece Square
M .4VA/20A 12V 5 A F L S Y Two piece Square*
N .4VA/15A 24V (w/ clear top protective lens)
2 7 C H N U Two piece Square*
(w/ smoke top protective lens)
4 TERMINATION/BASE STYLE
8 term 10 Term Termination Jumper 1 6 B G M T Two piece Square*
1 2 .250 TAB (QC) no barriers No (w/ white top protective lens)
A B .250 TAB (QC) with barriers No * All bottom lenses are molded of opaque material. Consult factory for other lens colors.
J K .250 TAB (QC) no barriers Yes T2 to 5 Lens color for LEDs must be clear, white, or match color of LED.
3 5 Solder Lug no barriers No Green or blue lenses are not recommended with Neon lamps.
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M. 11 ACTUATOR LOCK FUNCTION AND COLOR3
Lock Color Up Down Up & Down
Match Actuator A H R
5 ILLUMINATION & SWITCH SEALING Black B J S
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of White C K T
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals Red D L V
S 0 NONE Gray E M W
C 3 2 UP 3 (+) 7 () Safety Orange F N Y
H Z 2 INDEPENDENT 8 (+) 7 ()
DOUBLE POLE SWITCHES ONLY
M R 1 UP 3 (+) 6 () 12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend
21 22 23 24
6 LOCK OFF ON O I
Lock above terminals 1 & 4 end of switch.
25 O 26 O 27 O 28 I
W lock
F N
F
Notes: For additional legend options & codes, visit us at www.carlingtech.com.
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators; Custom colors are available, consult factory.
13 LEGEND ORIENTATION3 Orientation 1

0 No legend (used with codes 11-18 in selection 12)


3 Located over T1-4 end of switch.
4 Additional ratings available.See V-Series Switch Accessories page. 1 Orientation 1
5 Located over T3-6 end of switch. 2 Orientation 2
3 Orientation 3
4 Orientation 4 Orientation Orientation
1PM4F-1 4 2

45

4F
MC
18K45-2
13DMC-1 Orientation 3

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
V-Series Contura XIV Sealed Rocker Switches - Ordering Scheme | 19

V 1 D B B C 0 B FA P C AB 1 00
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Actuator Legend Legend Actuator,
Color Orientation Lens Legends

1 SERIES 6 & 7 LAMP


V No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
2 CIRCUIT LED* superbright superbright
Terminal Connections as viewed ( ) - momentary Red Amber Green Red
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T
1 - - 4 1 - - 4 24VDC D P J V
2 - - 5 2 - - 5 * Consult factory for daylight bright LED options. Typical current draw for LED is 20ma.
3 - - 6 3 - - 6
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 8 BRACKET COLOR & PANEL SEAL
1 A ON NONE OFF Color No Gasket 1 Gasket 2 Gasket
2 B (ON) NONE OFF Black B C D
3 C ON NONE (OFF) Gray G H J
4 D ON NONE ON
5 F ON NONE (ON) White W Y Z
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON) 9 ACTUATOR STYLE
SPECIAL CIRCUITS 0 No Actuator - Furnished separately
H* 2 & 3 2 & 3, 5 & 4 5&4 FA Contura XIV
G* 2 & 3, 5 & 6 2 & 3 OFF FB Contura XIV - Laser Etched
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2&1
E* 5 & 6 5 & 3 5&1
S* 2 & 3, 5 & 6 2 & 3 1&2 10 LENS COLOR / STYLE
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. 0 - No Actuator Z - No Lens
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit Clear White Amber Green Red Blue
E may be used for SP OFF-ON-ON circuit.
1 6 B G M T
2 7 C H N U
3 RATING3 3 8 D J P V
1 .4VA @ 28VDC Resistive 4 9 E K R W
B 15A 24V
C 20A 18V 5 A F L S Y PAD Printed
D 20A 12V 5 A N/A N/A N/A N/A Laser-Etched
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only) Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.

4 TERMINATION / BASE STYLE


8 term 10 Term Termination Jumper 11 ACTUATOR COLOR1
1 2 .250 TAB (QC) no barriers No O N/A - No Actuator
A B .250 TAB (QC) with barriers No C Black
J K .250 TAB (QC) no barriers Yes T2 to 5 S Red
3 4 Solder Lug no barriers No Y White
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No 12 ACTUATOR LENS or BODY LEGEND2
Note: Codes J & K for circuits H, G & M. 00 - No Legend this location/No actuator
11 ON 12 OFF 13 I 14 O
OFF ON O I
5 ILLUMINATION
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of 15 O O 16 O O 17 O I 18 I O
switch. Positive (+) and negative (-) symbols apply to LED lamps only F N N F
Lamps Illumination Type Lamp wired to Terminals F F
S NONE
A 1 INDEPENDENT 8 (+) 7 ()
B 1 DOWN 3 (+) 7 ()
C 2 UP 3 (+) 7 ()
13 LEGEND ORIENTATION
0 No legend
D 1 DOWN 3 (+) 7 ()
1 Orientation 1
2 DOWN 1 (+) 7 ()
2 Orientation 2
E 1 UP 1 (+) 7 ()
3 Orientation 3
2 UP 3 (+) 7 ()
4 Orientation 4
F 1 INDEPENDENT 8 (+) 7 () 1 2 3 4
2 UP 3 (+) 6 ()
G 1 INDEPENDENT 8 (+) 7 ()
2 UP 3 (+) 7 () 14 ACTUATOR / LENS LEGEND
H 2 INDEPENDENT 8 (+) 7 () 00 No legend this location / no actuator
SINGLE POLE SWITCHES ONLY (used with codes 11-18 in selection 12) Selection 14 required when switch requires two
J 1 DOWN 3 (+) 8 () legends. If the two legends consist of one lens and one body legend, lens legend must
2 INDEPENDENT 6 (+) 7 () be specified in selection 12; body legend specified in selection 14.
K 1 INDEPENDENT 8 (+) 7 () For legend options & codes, visit us at www.carlingtech.com.
2 INDEPENDENT 6 (+) 7 ()
DOUBLE POLE SWITCHES ONLY
L 1 DOWN 3 (+) 6 () Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
M 1 UP 3 (+) 6 ()
1 Custom colors are available. Consult factory.
N 1 DOWN 3 (+) 6 () 2 White imprinting is standard on black actuators; Black imprinting is standard on white,
2 DOWN 1 (+) 4 () red and gray actuators.
P 1 UP 1 (+) 4 () 3 Additional ratings available.See V-Series Switch Accessories page.
2 UP 3 (+) 6 ()
U 1 INDEPENDENT 8 (+) 7 ()
2 INDEPENDENT 10 (+) 9 ()

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
20 | V-Series Contura Sealed Rocker Switch Actuators Separately

Reduce inventory levels and cost by stocking actuators and base switches separately.
Contura II, III, IV, V, VI, VII, X, XI, XII, XIV Base switches separately: specify V with code selections 2-8 in the ordering schemes.
Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes.
Contura VI Actuator with lenses and inserts only: VV with code selections 9-16
Contura II, III, IV, V, VII Actuator only: VV with code A, C, E, G, P or Z for selection 9 & with selections 10-14 in the ordering schemes.
Contura X, XI, XII, XIV actuators with lenses separately: VV with code selections 9-14 in the ordering schemes.
Panel Seal: VPS

Contura X & XI actuators without lenses separately: Contura XII actuators without lenses separately:

1
VVR 6 1 00 1 2 3 4 5 1
VVP J 1 Z 21 1 00 2 3 4 5 6 7
Actuator Separately Actuator Lens Actuator Legend Actuator Style & Lens Lens Legend Legend Legend
Style/Color Opening Legend Orientation Color Opening Opening Orientation

1 CONTURA X & XI ACTUATOR SEPARATELY 1 CONTURA XII ACTUATOR SEPARATELY


VVR VVP

2 ACTUATOR STYLE & COLOR 2 ACTUATOR STYLE & COLOR


Black Gray White Red J Black K Gray N White M Red
Contura X 1 2 3 4
Contura XI 6 7 8 9
3,4 LENS OPENING FOR
3 LENS OPENING FOR1 Z No lens 1 Bar lens 2 Square lens
1 One bar lens 5 square lens on top/
2 One bar lenses bar lens on bottom
3 One square lens (Contura X only) 5, 7 LENS OR BODY LEGEND2
4 two square lens 00 - No Legend 21 22 23 24
OFF ON O I
4 ACTUATOR LENS OR BODY LEGEND 25 O 26 O 27 O 28 I
00 - No Legend this location F N
11 ON 12 OFF 13 I 14 O F
For additional legend options & codes, visit us at www.carlingtech.com.
OFF ON O I
15 O O 16 O O 17 O I 18 I O ORIENTATION OF

F N N F 6 LEGEND ORIENTATION3 ACTUATOR/LENS IN PANEL


ORIENTATION 1

F F 0 No legend
For additional legend options & codes, visit us at www.carlingtech.com. 1 Orientation 1 ORIENTATION 2
2 Orientation 2
ORIENTATION OF

5 LEGEND ORIENTATION1
ACTUATOR/LENS IN PANEL

0 No legend
ORIENTATION 1
Contura X, XI & XII actuator lens assembly separately:
1 Orientation 1

VVL 2 1 00 0
2 Orientation 2
3 Orientation 3
4 Orientation 4 ORIENTATION 4 ORIENTATION 2

1 2 3 4 5
Lens Separately Lens Lens Legend Legend
ORIENTATION 3 Style Color Orientation

1 CONTURA X, XI & XII LENS SEPARATELY


VVL

Contura X, XI & XII top piece of 2-piece lens separately:


2 LENS STYLE3

VVT 1
1 Bar lens 2 One Piece Square lens 3 Bottom of Two-Piece Square lens5
1 TOP OF LENS SEPARATELY
VVT
3 TRANSLUCENT LENS COLOR
1 Clear 2 White 3 Amber 4 Green4 5 Red 6 Blue4
1 2 2 COLOR
Lens Separately Color 1 Clear 2 Smoke 3 White
4 LENS OR BODY LEGEND2
00 - No Legend 21 22 23 24
Contura X, XI & XII actuator lens assembly: OFF ON O I
25 O 26 O 27 O 28 I
F N
actuator stem
posts mount toward actuator stem
top lens
bottom lens
} two piece
lens assembly
F
For additional legend options & codes, visit us at www.carlingtech.com.

1 piece lens/bar lens are positioned the same as bottom lens for assembly,
ORIENTATION OF

5 LEGEND ORIENTATION3
ACTUATOR/LENS IN PANEL

minus the top lens. Lenses snap in from bottom. 0 No legend


ORIENTATION 1

1 Orientation 1
Notes: 2 Orientation 2
1 If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2 3 Orientation 3
must be chosen. 4 Orientation 4
ORIENTATION 4 ORIENTATION 2

2 Center of actuator marking not available for Contura XII.


3 Legend is not available for bar style lens.
4 Not recommended with neon lamps.
5 Must also order top piece of 2 piece square lens separately. ORIENTATION 3

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
V-Series Contura Sealed Rocker Switch Accessories | 21

Easily integrate Contura products into your system, with Contura Accessories
Q.C. SELECTION GUIDE
Contura ConnectorsPART NO WIRE
RANGE
COMPANY Q.C. SELECTION ORIEN-
SERIES PLAIN TIN GUIDE TATION
PLATED AWG MM 2
BRASS WIRE
PART NO BRASS RANGE
(REF)
COMPANY 02965580 12 3.0 ORIEN-
SERIES PLAIN TIN 2 TATION
02965471
Q.C. Q.C.12010601
PLATED
SELECTION AWG(2)16-14
SELECTION
GUIDEQ.C. GUIDE MM(2)1.0-2.0
SELECTION GUIDE
PACKARD BRASS
02965470BRASS 16-14 (REF) 1.0-2.0 B
58 SERIES WIRE WIRE WIRE
PART
02965580 NO
02965469 PART NO RANGE
06288318 PART 20-18
12 NO RANGE 3.0 .5-.8 RANGE
COMPANY COMPANY
SERIES 02965471 COMPANY
PLAIN
SERIES 12010601
TIN
PLAIN
SERIES 12084590 (2)16-14 102TIN
TIN
PLAIN
ORIEN-
(2)1.0-2.0
TATION 5.0
2
ORIEN-
TATION
ORIEN-
TATION
PACKARD AWG MMAWG MMAWG MM 2
02965470 PLATED
BRASS Q.C. SELECTION
BRASS
BRASS 12052224
PLATED
BRASS GUIDE
16-14 PLATED
12 1.0-2.0(REF) 3.0 B (REF) TANG
58 SERIES BRASS (REF)BRASS
02965469 02965580 06288318 20-18 3.0 WIRE .5-.8 3.0
02965580 PART NO12015870 1202965580 16-14
12
RANGE 1.0-2.0
12 3.0
PACKARD
COMPANY02965471 12010601
02965471
12084590
Q.C. 12020035 12010601
(2)16-14
SELECTION 10(2)1.0-2.0
02965471 GUIDE 120106015.0(2)1.0-2.0
(2)16-14 ORIEN-
(2)16-14 (2)1.0-2.0
METRI-PACK
PACKARD PACKARD
SERIES PACKARD TIN (2)22-18 (2).5-.8 A
02965470 PLAIN 02965470 16-1402965470
12 1.0-2.0
AWG 16-14 MM 2 TATION
3.0 B1.0-2.0
16-14 B1.0-2.0 B TANG
58630 SERIES58
SERIES SERIES BRASS 58 12052224
SERIES PLATED
02965469 12015832
06288318PART
02965469 12015869
BRASS
NO20-18
06288318
02965469 .5-.8 20-18WIRE
20-18 (REF)
06288318 .5-.8 .5-.8
20-18 .5-.8
12015870 16-14 RANGE 1.0-2.0
PACKARD COMPANY 02965580 12084590 12052222 10
12084590 12 5.0 20-22
10 3.0
12084590 .35-.5
5.0 10ORIEN- 5.0
METRI-PACK SERIES 02965471 12020035
PLAIN 12010601
TIN
(2)22-18
(2)16-14 (2).5-.82 12TATIONA 3.0 TANG
TANG SYMBOL
TANG TANG
= SHOWS ORIENTATION OF TANG IN SLOT
12052224
BRASS PLATED
12052224
12 AWG3.0 12(2)1.0-2.0MM 3.0
12052224
16-12 1.3-3
630 SERIES PACKARD 60253-1 60253-2
BRASS (REF) SYMBOL
AMP 58 12015832
SERIES
02965470 12015869
12015870 12015870
16-14 20-18
16-14
1.0-2.0
1.0-2.0
12015870
16-14 .5-.8 1.0-2.0
B
16-14 1.0-2.0
PACKARD PACKARD 02965469 PACKARD
02965580 06288318 20-18 12 (2) 16 .5-.8 3.0 (2) 1.3
250 SERIES
METRI-PACK METRI-PACK 12052222(2)22-18
12020035
METRI-PACK 12020035 20-22(2).5-.8
(2)22-18
12020035 .35-.5A(2).5-.8
(2)22-18 A(2).5-.8B A
FASTIN-FASTON
630 SERIES 630 SERIES 42100-102965471
630 SERIES 42100-2
12010601
12084590 18-14
10 (2)16-14 5.0(2)1.0-2.0 .8-2 TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT
12015832
PACKARD 12015869
12015832 12015869
20-18
12015832
16-12 .5-.812015869
20-18 1.3-3 .5-.8
20-18 .5-.8 TANG
02965470 12052224 12 16-14 3.0 1.0-2.0 B SYMBOL
AMP 58 60253-1
SERIES 60295-1 60253-2
12052222 60295-2
20-22
12052222 22-18
.35-.520-22
12052222 .35-.5 .3-.9
20-22 .35-.5
PACKARD 02965469 06288318 (2) 16
12015870 16-14 20-18 (2) .5-.8
1.0-2.0 1.3 TANG SYMBOL = TANG SYMBOL
SHOWS = TANG SYMBOL
ORIENTATION
SHOWS =
OFORIENTATION
TANG IN
SHOWS
SLOTOFORIENTATION
TANG IN SLOT
OF TANG IN SLOT
250 SERIESMETRI-PACK 12020035 16-12 (2)22-18 1.3-3 16-12(2).5-.8 1.3-3 16-12
A B 1.3-3
60253-1 60253-2
60253-1 60253-2
60253-1 60253-2 SYMBOL SYMBOL SYMBOL
NOTE:AMPConsult
FASTIN-FASTON Delphi
AMP
630 SERIES Packard
42100-1 and/or
42100-2
AMP 12084590
Amp (2) on
16 actual
18-14 10
part
(2) 1.3
(2) numbers
16
5.0 and availability.
.8-2 (2) 1.3
(2) 16 (2) 1.3 TANG
250 SERIES
AMP is 250 SERIES 12015832
a registered 250 SERIES
trademark 12015869
of12052224
AMP Inc. 20-18 12
Harrisburg,.5-.8 PA 3.0 B B B
60295-1 FASTIN-FASTON
FASTIN-FASTON FASTIN-FASTON
42100-1 60295-2
42100-2
42100-112052222 18-14
42100-2 22-18
42100-1 .8-218-14
20-2216-14 42100-2
.35-.5 .3-.9
1.0-2.0.8-218-14 .8-2
Delphi Packard
PACKARDis a registered trademark of Delphi-Packard Electrical Systems
12015870 TANG Warren,
SYMBOL = Ohio SHOWS ORIENTATION OF TANG IN SLOT
60295-1
METRI-PACK 60295-2
60295-1 1202003522-18
60295-2
60295-1
16-12 .3-.9
(2)22-1822-181.3-3(2).5-.8.3-.9
60295-2 22-18 A .3-.9
NOTE: Consult Delphi 630Packard
AMP SERIES and/or
60253-1 Amp60253-2
on actual part numbers and availability. SYMBOL
12015832 12015869 (2) 1620-18 (2) 1.3 .5-.8 .820[20.83]
NOTE: AMP is aDelphi
Consult registered
NOTE:
250 SERIES
Packard trademark
Consult NOTE:
and/or
Delphi
Amp of
onAMP
Packard
Consult
actual Inc.
and/or
Delphi Harrisburg,
partAmp
numbers
Packard
on actual
and/or PAAmp
and part
availability.
numbers
on actual
and part
availability.
Bnumbers and availability.
Delphi
AMP isPackard is.820[20.83]
FASTIN-FASTON
a registered
AMPtrademark42100-1
a registered
is a registered
of AMP
AMP is42100-2
trademark
trademark
Inc. of
Harrisburg,
a registered
of AMP
12052222 PA 18-14
Delphi-Packard
trademark
Inc. Harrisburg,
20-22of AMP .8-2
Electrical
PAInc. Systems
Harrisburg,
.35-.5 PA Warren, TANG Ohio SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT
Delphi Packard is Delphi
a registered
Packard
trademark
is Delphi
60295-1 a registered
of
Packard
Delphi-Packard
60295-2trademark
is a registered
of
Electrical
22-18Delphi-Packard
16-12trademark
Systems of
Electrical
.3-.91.3-3Warren,
Delphi-Packard
Systems
Ohio Electrical
Warren, Ohio
Systems Warren, Ohio
60253-1 60253-2 SYMBOL
AMP
NOTE: Consult Delphi Packard and/or Amp on actual part numbers
250 SERIES
.820[20.83] .820[20.83] .820[20.83]
(2) 16 and availability.
(2) 1.3
B .820[20.83] .820[20.83]
.820[20.83]
FASTIN-FASTON .820[20.83]
AMP is a registered trademark
42100-1 of AMP .820[20.83]
Inc. Harrisburg,
42100-2 PA
18-14 .8-2
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
60295-1 60295-2 22-18 .3-.9 .770[19.56]
NOTE: Consult.820[20.83] .820[20.83]
Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA .770[19.56] .770[19.56] .770[19.56]
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio .770[19.56]
.920[23.37] .820[20.83] .920[23.37] 1.170[29.72]
.820[20.83] .770[19.56]
.920[23.37] .920[23.37] .920[23.37] .920[23.37] .920[23.37] .920[23.37] 1.170[29.72] 1.170[29.72] 1.170[29.72]
A .920[23.37] A .920[23.37] A 1.170[29.72] A
A A A A A A VC2 PACKARD 630 PACKARD 630
PACKARD 630
VC1 .920[23.37] PACKARD 630
VC1 .920[23.37] A
VC2
A
1.170[29.72]
.770[19.56]
A A A A
VC2 VC2 VC2
.950[24.13]
PACKARD 630 PACKARD 630 PACKARD
PACKARD
630 630 PACKARD 630 PACKARD 630
PACKARD 630 PACKARD 630 PACKARDPACKARD
630 630 PACKARD 630 PACKARD 630
B VC1 VC1 VC1 VC1 VC1
B VC1 VC2 VC2 VC2
A B B B B A B B .950[24.13]
A .950[24.13] .950[24.13] A
A A A
PACKARDBA630 B B
AMP,
630 PACKARD 58 AMP, PACKARD 58 AMP,
58 PACKARD 58 AMP VC2 AMP B AMP PACKARD 630 B B B PACKARD
B 630

10 10
3 23 1 28 10
1 38 2 1 7.920[23.37]
84 1053 6729 417VC1
845VC1 56 96 9 10 73 4 2 51 689 10 10
PACKARD
AMP, PACKARD 58 PACKARD
AMP, PACKARD 58 630
AMP, PACKARD AMP, PACKARD 58 AMPAMP, PACKARD 58 AMP
VC2 AMPAMP AMP PACKARD 630
VC1 VC2
3 32.920[23.37]
128 1 7104 8 679 4 73 45 69
PACKARD 630 PACKARD 630 AMP, 58
PACKARD 58AMP, PACKARD AMP, PACKARD 58
3 5 2 619 8VC27 4 5 15 8 6 9 .950[24.13]
VC1 AMP, PACKARD 58 AMP, PACKARD 58 AMP,
AMP,
PACKARD
PACKARD 58 58 AMP, PACKARD 58
B B B B 2 .950[24.13]
3 2 1.170[29.72]
1 8 7 3 4 235 1 62 8 1 87 4 5 6 7 4 5 6 7 4 5 6
AMP, PACKARD 58 AMP, PACKARD 58 AMP AMP B B
B
1.266[32.16]
AMP, PACKARD 58
10 3A 1.266[32.16]
2 1 8 1.466[37.24]
AMP,1.266[32.16]
PACKARD 58
5 1.466[37.24]
7 41.466[37.24]
69 1.266[32.16]
10 3 2 11.266[32.16]
1.466[37.24]
AMP 1.466[37.24]
1.266[32.16]
7 4 5 6 9 1.466[37.24] 1.466[37.24]
AMP 1.466[37.24] 1.250[31.75] 1.250[31.75] 1.250[31.75]B
1.266[32.16] 81.266[32.16] 1.250[31.75]
AMP, PACKARD 58 AMP, PACKARD 58

10 3 2 1 8 PACKARD 630
7 4
PACKARD 630
A
5 69 10 3 2 VC21 8 3 2
3 A2
1 8
1 8
7 4 5 69
AMP, PACKARD
7 58 A4 5 6
PACKARD 630 PACKARD 630
AMP, PACKARD 58
7 4 5 6
VC1 VC1 VC2
MARKING DETAIL1.266[32.16]
BMARKING DETAILMARKING
MARKING 1.466[37.24]
DETAIL
DETAIL
MARKING DETAIL B MARKING
MARKING1.266[32.16]
DETAIL 1.466[37.24]
DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAILMARKING
MARKING
DETAIL
DETAIL 1.250[31.75]
.950[24.13]
MARKING DETAIL MARKING
MARKINGDETAIL
DETAIL MARKING DETAIL MARKING DETAIL
1.266[32.16]
FRONT VIEW DETAIL
MARKING FRONT VIEW REAR1.466[37.24]
FRONT
VIEW
AMP, PACKARD 58
VIEW REAR
MARKING VIEW
DETAIL FRONT
REARVIEW1.266[32.16]
VIEW
AMP, PACKARD 58
FRONT VIEW DETAIL
MARKING FRONT
REAR VIEW
VIEW 1.466[37.24]
REAR VIEWMARKING
AMP
FRONT
REAR
VIEW
VIEW
B DETAIL
FRONT VIEW REAR
FRONTVIEW
MARKING
B AMP 1.250[31.75]
VIEW REAR VIEW
DETAIL REAR VIEW
MARKING DETAIL
FRONT 10 3DETAIL
VIEW
MARKING 2 1 8 7 4DETAIL
REAR
MARKING 5 69
VIEW 2 1FRONT
10 3 DETAIL
MARKING 8 VIEW 7 4 DETAIL
MARKING 5 69 REAR VIEW
AMP, PACKARD 58
MARKING
3 2
DETAIL
1 8 FRONT
DETAIL VIEW
AMP, PACKARD 58
MARKING REAR VIEW
VC1 FRONT VIEW
VC1 REAR VIEW
VC1 VC2 FRONT VIEW VC2
VCH REAR VIEW
VC2 FRONT
VCHVIEW REAR7 VIEW
VCH
4 5 6

MARKING DETAIL
CONNECTOR HOUSING1.266[32.16]
CONNECTOR MARKING HOUSING
HOUSING
CONNECTOR DETAIL MARKING
1.466[37.24]CONNECTOR HOUSING
CONNECTOR DETAIL
1.266[32.16] HOUSING
CONNECTOR HOUSING MARKINGCONNECTOR
1.466[37.24] DETAIL HOUSING MARKING
1.250[31.75]
CONNECTOR HOUSING DETAIL HOUSING
CONNECTOR MARKING DETAIL
VC1 VC1
FRONT VIEW REAR VIEW (For AMP terminalsVC2
FRONT
(For AMP VIEW
only) VC2
(For
terminals AMP terminals only) REAR VIEW
only) VCH FRONT VIEW VCH REAR VIEW
CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING
CONNECTOR HOUSING
MARKING DETAIL
FRONT VIEW
MARKING DETAIL
REAR VIEW
CONNECTOR
MARKING DETAIL
(For AMP terminals HOUSINGMARKING
only)
FRONT VIEW
DETAIL
REAR VIEW
MARKING DETAIL
FRONT VIEW CONNECTOR
REAR VIEW HOUSING
MARKING DETAIL

VC1 (ForVC2
AMP terminals only) VCH
Contura X Boot (P/N VB1-01)
CONNECTOR HOUSING VC1
CONNECTOR HOUSING
CONNECTOR
(For
VC2 HOUSING
AMP terminals
CONNECTOR only)
HOUSING
(For AMP terminals only)
Additional V-Series Ratings VCH
CONNECTOR HOUSING
CONNECTOR HOUSING

1 .4VA @ 28VDC Resistive


1.050[26.67] 1.050[26.67] 4
1.050[26.67] 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, No Agency Listings
1.050[26.67] 51 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified
62 15A 125VAC 1/2 HP, 12(2)A 125 VAC T85
2.000[50.80] 2.000[50.80] 1.050[26.67]
2.000[50.80]
1.050[26.67] CONTURA7VB1-01
2 VB1-01
X BOOT
VB1-01
15A
CONTURA 125VAC
X BOOT
VB1-01
CONTURA1/2 XHP,
BOOT12(6)A 125 VAC T85
2.000[50.80] CONTURA X BOOT
1.050[26.67]
8 2 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(2)A 250 VAC T85
92 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(6)A 250 VAC T85
VB1-01
2.000[50.80] B CONTURA X BOOT 15A 24V VB1-01
2.000[50.80]
.757[19.23]
.757[19.23].757[19.23] C
.757[19.23] 20A 18V
CONTURA X BOOT
VB1-01
2.000[50.80] D 20A 12V
CONTURA X BOOT

.757[19.23]
E 20A 14V, 10A 14VT (circuits 1, 4, A, & D only)
F 10A 14V, 6A, 14VT (circuit G only)
G 20A 6V
Contura II, III, IV & V Actuator Removal Tool
.757[19.23]
H 20A 3V
3.99 [101.35] .757[19.23]
(P/N VRT) 3.99 [101.35] 3.99 [101.35] 3.99 [101.35]
L
VRT
15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L
MVRT REMOVAL .4VA/20A 12V VRT(combi-contact)
TOP

ACTUATOR VRT
TOP TOP TOP

TOOL (combination gold/silver


REMOVAL contacts for borderline dry circuit applications)
INSERT POINTS UNDER
3.99 [101.35]
INSERT POINTS UNDER
ACTUATOR .900 [22.86]
INSERTAND
POINTS
PUSHUNDER
ACTUATOR REMOVAL
TOOLACTUATOR
INSERT POINTS UNDER
REMOVAL
ACTUATOR
ACTUATOR IN
HOLD
.900 [22.86]
FLUSH ON BRACKET
ACTUATOR .900 [22.86] (For
ACTUATOR flush
.900 bracket)
[22.86] TOOL TOOL
HOLD FLUSH ON BRACKET ANDHOLD
IN
PUSH FLUSH ON BRACKET AND HOLD
INTOP TOP
N bracket)
(For flush (For .4VA/15A
PUSH FLUSH ON BRACKET AND PUSH
IN
VRT 24V
flush bracket)
(For (combi-contact)
flush bracket)
ACTUATOR TOOL (combination gold/silver contacts for borderline dry circuit applications)
REMOVAL
TOP TOP TOP
INSERT POINTS UNDER
ACTUATOR .900 [22.86]
HOLD FLUSH ON BRACKET AND PUSH
IN (For flush bracket)
TOP

3.99 [101.35] NOTES


3.99 [101.35]
Consult factory to determine availability for individual circuits and their HP rating.
VRT
TOP
TOP
1. Not avaiable VRTwith Contura
ACTUATOR 7 or 14 rocker styles.
REMOVAL
INSERT POINTS UNDER
2. ACTUATOR
Ratings 6 - 9 REMOVAL
are UL, CSA & VDE certified, require terminations A or B for double
INSERT POINTS UNDER .900 [22.86] TOOL TOOL
HOLD FLUSH ON BRACKET AND PUSH.900 [22.86]
ACTUATOR

(For flush bracket)


ACTUATOR
HOLD FLUSH
IN
INON BRACKET AND PUSH pole(For
circuits,
flush & are not available with illumination circuits 4, 8, D, J, N, & T or with
bracket)
TOP
TOP
wire lead or solder lug terminations.
Circuits 1, 4, A, D, H, M & E are not available with rating 6 & 8. Rating 7 & 9 only available
with circuits 1, 4, A & D. Circuits 2, 3, 5, 7, 8, K, L are 1/2 HP 250VAC only with rating 8.
Ratings 6 & 7 must specify lamp code 1 (125VAC neon). Ratings 8 & 9 must specify lamp
code 2 (250VAC neon). Rating L available with circuits 1, 4, A & D only.

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
22 | V-Series Contura Sealed Rocker Switch Accessories

Contura Mounting Panels


Dimensional Specifications: in. [mm]

Contura Hole Plug


Dimensional Specifications: in. [mm]
1.450 [36.83]

TEST CUT
.830 [21.08] HOLE IN VHP
ACTUAL CONTURA II,III HOLE PLUG
MATERIAL

1.240 [31.50]
1.820 [46.23]
VHP
.430 [10.92] CONTURA II,III HOLE PLUG VH2
STANDARD HOLE PLUG
(With wing serrations)
VH1
STANDARD HOLE PLUG
2.000 [50.80] (No wing serrations)
(With VC1 connector attached)

1.067 [27.10]

DETAIL VIEW
VH3 VH4 VH1,VH3 & VH5
CONTURA IV HOLE PLUG CONTURA IV HOLE PLUG HOLE PLUGS
(No wing serrations) (With wing serrations) (No wing serrations
1.928 [48.97] for ease of removal)

1.020 [25.91]

DETAIL VIEW
VH5 VH6 VH2,VH4 & VH6
CONTURA V HOLE PLUG CONTURA V HOLE PLUG HOLE PLUGS
(No wing serrations) (With wing serrations) (With wing serrations)

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
Notes | 23

* Intentionally left blank

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue Plainville, CT 06062
Phone: (860) 793-9281 Fax: (860) 793-9231
Email: sales@carlingtech.com www.carlingtech.com

East Region Sales Office, CT ersm@carlingtech.com


Midwest Region Sales Office, IL mrsm@carlingtech.com
West Region Sales Office, CA wrsm@carlingtech.com

Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Int + 852-2737-2277 Fax: Int + 852-2736-9332
Email: sales@carlingtech.com.hk

Shenzhen, China shenzhen@carlingtech.com


Shanghai, China shanghai@carlingtech.com
Pune, India india@carlingtech.com
Kaohsiung, Taiwan taiwan@carlingtech.com
Yokohama, Japan japan@carlingtech.com

Europe/Middle East/Africa Headquarters


Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Int + 44 1392-364422 Fax: Int + 44 1392-364477
Email: ltd.sales@carlingtech.com