Citect for Windows, Version 5.

xx
SNMPII driver, User information and design
Citect for Windows, V5.xx SNMP Driver

1. USER INFORMATION...............................................................................................................3
1.1 DEVICE APPLICATION NOTES ...................................................................................................3
1.1.1 Overview ........................................................................................................................3
1.1.2 Citect SNMPII driver Support Summary..........................................................................5
1.1.3 Setup guide.....................................................................................................................5
1.1.4 Reference: Required Components....................................................................................7
1.1.5 Reference: Communications Forms.................................................................................8
1.1.6 Reference: Wiring Diagrams...........................................................................................9
1.1.7 Reference: Data Types....................................................................................................9
1.1.8 Reference: SNMP Traps................................................................................................ 10
1.1.9 Reference: An alternative SNMP Port ........................................................................... 12
1.1.10 Hints, Tips, and Frequently Asked Questions................................................................. 12
1.2 DRIVER REFERENCE .............................................................................................................. 14
1.2.1 Description................................................................................................................... 15
1.2.2 Driver generated error codes........................................................................................ 15
1.2.3 Parameters, options and settings................................................................................... 15
1.2.4 Advanced...................................................................................................................... 17
2. ANALYSIS................................................................................................................................. 18
2.1 OVERVIEW ........................................................................................................................... 18
2.2 VERSIONS OF SNMP ............................................................................................................. 19
2.3 PACKET TRANSMISSION ........................................................................................................ 19
2.4 OBJECT IDENTIFIERS ............................................................................................................. 21
2.5 DATA TYPES ......................................................................................................................... 22
2.6 MANAGED OBJECTS .............................................................................................................. 23
2.7 SNMP PACKETS ................................................................................................................... 24
2.8 MICROSOFT SNMP API & SNMP MANAGEMENT API......................................................... 24
2.8.1 Management Functions................................................................................................. 24
2.8.2 Utility Functions........................................................................................................... 25
2.9 GLOSSARY ............................................................................................................................ 26
3. DRIVER IMPLEMENTATION................................................................................................ 28
3.1 DEVELOPMENT RESOURCES ................................................................................................... 28
3.1.1 Contacts ....................................................................................................................... 28
3.1.2 Documents.................................................................................................................... 28
3.1.3 Software / Hardware..................................................................................................... 29
3.2 RISK AREAS .......................................................................................................................... 29
3.3 DEVELOPMENT PLAN ............................................................................................................. 29
3.4 BETA TESTERS ...................................................................................................................... 29
4. APPENDIX ................................................................................................................................ 30
4.1 V1 SNMP MANUAL SETUP GUIDE .......................................................................................... 30
4.2 SNMP TIME BASED PDU GROUPING .................................................................................... 32
4.3 SNMP RELATED BUGS FIXED IN WINDOWS NT SERVICE PACKS ............................................ 33
4.3.1 Service Pack 6 .............................................................................................................. 33
4.3.2 Service Pack 5 .............................................................................................................. 34
4.3.3 Service Pack 4 .............................................................................................................. 34
4.3.4 Service Pack 3 .............................................................................................................. 38
4.3.5 Service Pack 2 .............................................................................................................. 38
4.3.6 Service Pack 1 .............................................................................................................. 39
4.4 SNMP RELATED BUGS IN WINDOWS NT (NOT FIXED)............................................................ 39
4.5 SNMP RELATED BUGS IN WINDOWS 95/98 (NOT FIXED) ........................................................ 49

Copyright 1999 Ci Technologies Page: 2


Citect for Windows, V5.xx SNMP Driver

1. User information
Simple Network Management Protocol (SNMP) is a network management standard
widely used in TCP/IP networks to monitor and control computers, routers, printers
and other devices connected to a network.

SNMP uses a distributed architecture consisting of managers and agents. A


manager is an SNMP application that generates queries to SNMP agent
applications. An agent is an SNMP application that responds to queries from SNMP
manager applications. The SNMP agent is responsible for retrieving and updating
local management information based on the requests of the SNMP manager. The
agent also notifies registered managers when a significant event or trap occurs.

The SNMP manager is realised in Citect through the SNMPII driver. On computers
running Microsoft Windows NT, Windows 98, or Windows 95 the SNMP
agent is implemented by the SNMP service (SNMP.EXE).

Every SNMP manageable device has a set of objectsthat can be read or modified
via SNMP. This set of managed objects is known as a Management Information
Base (MIB).

1.1 Device Application notes

Detail
Manufacturer -
Device name Any SNMP manageable device
Communications Ethernet UDP/IP
method

1.1.1 Overview

Each device to be monitored or controlled by Citect must be connected to a TCP/IP


network. This is illustrated in the following diagram.

ROUTER NETWORK
Citect PRINTER

PC
TCP/IP

PC

Fig 1.1.1 Device connection

Copyright 1999 Ci Technologies Page: 3


Citect for Windows, V5.xx SNMP Driver

All SNMP manageable devices that reside on a TCP/IP network are required to
support a minimum standard set of managed objects, collectively known as MIB-II
. Industry vendors such as Cisco or Microsoft, can define additional MIB
s that allow
unique hardware or software services developed by the vendor to be monitored
and managed by an SNMP manager.

Each object in a MIB is identified by a universally unique label referred to as an


object-identifier (OID). The identifier includes the object
s type (such as counter,
string, gauge, or address), the object s access level (such as read / write), size
restrictions, and range information.

The object name space is implemented as a multi-part, hierarchical, naming


scheme. A hierarchical naming scheme can be viewed as an inverted tree with the
branches pointing downward. Each point where a new branch is added is referred
to as a node. This OID is internationally accepted and allows developers and
vendors to create new components and resources and assign a unique OID to each
new component or resource.

The OID naming scheme is governed by the Internet Engineering Task Force
(IETF). The IETF grants authority for parts of the name space to individual
organizations, such as Microsoft. For example, Microsoft has the authority to assign
the OIDs that can be derived by branching downward from the node in the MIB
name tree that starts at .1.3.6.1.4.1.311. The following diagram illustrates this
concept.

.1
International Standards Organisation (ISO)

.3
Organisation (ORG)

.6
Department of Defence (DOD)

.1
Internet

.1 .2 .3 .4
Directory Mgmt Experimental Private

.1 .1
MIB-2 Enterprises

.311 .437
Microsoft Cisco

.1
Software

.1 .2 .3
Systems Wins Dhcp

Fig 1.1.2 OID Hierarchy Sample

Copyright 1999 Ci Technologies Page: 4


Citect for Windows, V5.xx SNMP Driver

SNMP programs use the OID to identify the objects on each device that can be
managed by using SNMP. For example, when Citect requires information about
managed-objects from some computer on the network, the SNMPII driver sends a
message over the network that requests information about the object as identified
by the OID. The computer that receives the message can use the OID to retrieve
information from the specific object on the computer and send the information
back to Citect.

The OID in the hierarchy is written as a sequence of sub-identifiers beginning at


the root and ending at the object. Sub-identifiers are separated with a period. For
example, the OID for sysDescr which is a textual description of the SNMP
manageable device is : .1.3.6.1.2.1.1.1.0 . This type of reference is called a scalar
reference in SNMP terminology. SNMP supports repeated instances of a OID in a
table. The OID in this situation has an instance number added to the OID, e.g.
ifDescr 1.3.6.1.2.1.2.2.1.2 becomes 1.3.6.1.2.1.2.2.1.2.x.0 where x can be
from say 1 to 10.

SNMP Redundancy

Redundancy in the Citect context, is a function of the support provided in the SNMP
device you are talking to. Some SNMP devices have a fixed IP address of who can
talk to them (for security). In this case, only one Citect IOServer can talk to them.
Redundancy is not possible.
However, most SNMP devices allow anyone to talk to them provided their SNMP
community name (like a password) is valid. In this case, Citect redundancy will
work.
For a SNMP device to support trap redundancy (i.e. to send traps to multiple
places), the device must support allowing 2 or more trap IP addresses. Each trap
must be sent to the primary and standby IOServer. If the SNMP device only
supports one trap IP address, then the standby IOServer will NOT receive traps
should the primary server be down.

1.1.2 Citect SNMPII driver Support Summary

This driver will be implemented with Microsoft Windows NT SNMP API (SNMP API
hereafter). The SNMP API supports SNMPv1 and SNMPv2C.
To cooperate with Citect, only GET, SET and TRAP requests are used in this driver.
GET_NEXT and WALK function won t be provided.
All traps will be retrieved from windows SNMP Trap service and be stored in a
driver global queue for user to process.
Version 2 of the driver adds trap forwarding, MIB table support and efficiency
improvements.

1.1.3 Setup guide

1.1.3.1 Device Setup


This section refers to the setup of the device that Citect will query via SNMP.

Step 1
Connect the device to the TCP/IP network. For a PC, a network card must be
installed.

Step 2
If the device is a PC running Windows NT/98/95, the TCP/IP protocol must be
installed and configured, as well as the SNMP service. Refer to the online help in
Control Panelfor more information.

Copyright 1999 Ci Technologies Page: 5


Citect for Windows, V5.xx SNMP Driver

Note 1: any installed Service Packmust be re-installed after the TCP/IP protocol
or SNMP service is installed.

Note 2: if the SNMP service is installed on a PC running Windows 95, the service
will not function correctly until the file: INETMIB1.DLL, is copied from the
installation folder to the WINDOWS\SYSTEM folder.

Step 3
The device must be configured with an IP address. Refer to the devices hardware
documentation for more information; or if the device is a PC, refer to the online
help in Control Panel.

1.1.3.2 Citect MIB2CIT Utilty Use

SNMPVARS.DBF format :

Field Name Description


A unique index number. This does not have to be sequential. This
INDEX number maps to the TagAddress Nx number. This numeric
record tag must be unique within a data type.
A unique descriptive name given to each Citect I/O Device, as
DEVNAME specified in the I/O Devices form. It must not exceed 16 characters
in length.
CITECT The citect tag name for the object. Not to exceed 32 characters in
TAGNAME length.
The Citect Data Type of the object, which can have one of the
following values:
LONG, REAL, STRING

CTYPE Note that Tags with a Citect Data Type of STRING, are limited to a
maximum length of 255 characters.
For Tags with a required numeric range which goes outside the
range: 2147483648 to 2147483647, you could assign a Citect
Data Type of REAL.
# The SNMP name for the OID object. Not to exceed 32 characters in
SNMPNAME
length.
# The SNMP Object Identifier, e.g: .1.3.6.1.2.1.1.1.0 . Table entries
OID
will end in a .x
The Citect SNMP data type, and can have one of the following
values:
DA - for alphanumeric string objects(octet string processed as
null-terminated string)
BA - for alphanumeric string objects(octet string processed as
#
SNMPTYPE binary string)
N - for numeric objects (treat as long in Citect)
NE - for enumerated numeric objects (this is equivalent to the
N type but indicates that Cicode macros should be generated using
the MIB2CIT.EXE utility). NE & N are the same items.
R - for numeric objects(treat as real in Citect)
# The readability/ write-ability of the tag, which can have one of the
R/W
following values:

#
This information normally comes from the MIB via MIB2CIT.EXE

Copyright 1999 Ci Technologies Page: 6


Citect for Windows, V5.xx SNMP Driver

R - Read Only
W - Write Only
RW - Read and Write
# An optional comment, which must not exceed 48 characters in
COMMENT
length. Any commas within this text must be removed.

SNMP_ENUMS.TXT A comma separated file generated by the MIB2CIT utility for


future Cicode use. Its format is :

The SNMP name for the OID object. Not to exceed 32 characters in
SNMPNAME
length.
CTYPE Citect Data Type
Enumerated values for the OID. These are data pairs of :
ENUMS {number1 Text1}{number2 Text2}
This data is not used by the driver

e.g. sysID,LONG,{1 unit1}{2 unit2}{3 unit3}

SNMP_TRAPS.TXT - A comma separated file generated by the MIB2CIT utility for


future Cicode use. Its format is :

SNMPNAME The SNMP trap name. Not to exceed 32 characters in length.


ENTERPRISE The enterprise trap OID number, e.g. 1.3.6.1.4.1.6126.2.42
TRAP OID where 42 is the enterprise trap number.
IP ADDRESS Of the I/O Device
An optional comment, which must not exceed 48 characters in
COMMENT
length. Comment will be in quotes.
VARBINDS The varbind variable names for the trap. Comma separated items.

1.1.3.3 Manual Citect Setup

For integrity of the system, the tagname, data type, address and IO device must
be the same between equivalent records in variable.DBF and the SNMPVARS.DBF.
The address must be unique between data types. The SNMP OID field MUST be
correct for the system to work.

1.1.4 Reference: Required Components


1.1.4.1 Software

The Citect 5.xx SNMPII Driver will only function on a PC running Microsoft Windows
NT (Server or Workstation) 4.0 or greater; Service Pack 6 or higher is
recommended for NT 4.0. The SNMPII Driver WILL NOT work on a PC running
Windows 98 or 95.

A PC used as an SNMP host i.e. (as a Citect I/O Device) may use either Windows
NT 4.0 or Windows 98/95. In this case, the TCP/IP protocol, and the SNMP service
will be required. These software components are included on the Microsoft
Windows NT/98/95 CD.

Copyright 1999 Ci Technologies Page: 7


Citect for Windows, V5.xx SNMP Driver

1.1.4.2 Hardware

If a PC is to be used as an SNMP host, a TCP/IP compatible network card will be


required.

1.1.5 Reference: Communications Forms

Boards form
Field Default Allowable values
Board Name This field is user defined, and is not used by the driver.
Board Type SNMPII
Address 0
I/O Port BLANK
Interrupt BLANK
Special Opt BLANK
Comment This field is user defined and is not used by the driver.

Ports form
Field Default Allowable values
Port Name This field is user defined and is not used by the driver.
Port number Must be unique, but is not used in this driver.
Board name Refers to the board previously defined in boardsform.
Baud rate BLANK
Data bits BLANK
Stop bits BLANK
Parity BLANK
Special Opt SNMPVARS.DBF The .DBF file users to store additional tag data
Comment This field is user defined and is not used by the driver.
Note: the SNMPVARS.DBF must be placed in the project directory. If there is no
snmpvars.dbf in the project directory, then the Port will not initialise.

I/O Devices form


Field Default Allowable values
Name This field is user defined, and is not used by the driver.
Number Must be unique1, but is not used by the driver.
Address Use a valid IP address; format is:
aaa.bbb.ccc.ddd community_string . The
community string has to be correct to ensure
access to the remote agent. The IP address can
also be a devicename known by the IP
network. A third parameter will appear in the
field which is added by the MIB2CIT utility. This
3rd argument is NOT used by the driver.
Protocol SNMPII
Port name Refers to the port previously defined in portsform.
Comment This field is user defined and is not used by the driver.

1
See Citect Online Help for details on how to set up redundant I/O Devices.

Copyright 1999 Ci Technologies Page: 8


Citect for Windows, V5.xx SNMP Driver

1.1.6 Reference: Wiring Diagrams

Any standard TCP/IP network wiring.

1.1.7 Reference: Data Types

Citect
Tag Citect Data
IO Device Type Applicable SNMP data type
Address Types
Format
ASN_OCTETSTRING,
ASN_BITS,
Alphanumeric (display string)
DAn STRING ASN_OPAQUE,
objects
ASN_IPADDRESS,
ASN_OBJECTIDENTIFIER,
ASN_OCTETSTRING,
Alphanumeric (binary string)
BAn STRING ASN_BITS,
objects
ASN_OPAQUE,
ASN_INTEGER,
ASN_INTEGER32,
ASN_UNSIGNED32,
Numeric objects(treat as long in
Nn LONG ASN_COUNTER64,
Citect)
ASN_COUNTER32,
ASN_GAUGE32,
ASN_TIMECLIDKS
ASN_INTEGER,
ASN_INTEGER32,
ASN_UNSIGNED32,
Numeric objects (treat as real in
Rn REAL ASN_COUNTER64,
Citect)
ASN_COUNTER32,
ASN_GAUGE32,
ASN_TIMECLIDKS
Trap objects (null-terminated
Ta STRING Trap object
string)
Trap object (only for
ASN_OCTETSTRING,
Trap objects (binary string) BTa STRING
ASN_BITS, ASN_OPAQUE type
value in varbinding field)
IP address to forward a copy of
the last trap to. One IP address is
Trap forwarding (write only) TF STRING
required per call to TF. TF can be
called multiple times.
TN as read is the traps in queue,
0 for nothing. A TN write removes
Trap Next (read & write) TN LONG
the current entry and gets the
next.
A read of TNVB returns the
Mutiple trap variable TNVB LONG number of varbinds in the trap, a
write to TNVB controls which
varbinds data is going to be read

Copyright 1999 Ci Technologies Page: 9


Citect for Windows, V5.xx SNMP Driver

or written to.
Note 1: n is from 0 to 65535, a is from 0 to 6. T0 to T6 are read and write
variables.
Note 2: for the sting types, the DA stands for null-terminated string and the BA
stands for binary string. Null-terminated string is a string with 0x00 as end flag,
but in a binary string a 0x00 may be valid content. For example
<0x41><0x42><0x43><0x00><0x61><0x62><0x63>, if defined as DA, the
citect will display it as ABC and the content from <0x61> will be truncated, if
defined as BA, the citect will display it as 41424300616263. This also applies to
those ASN_OCTETSTRING type fields in a trap object, with DA replaced by T and BA
replaced by BT.

Whether a Tag is readable / writeable is dependent on how the SNMP object to


which it corresponds is defined in the appropriate .MIB file.

For the type DA, BA, N and R, the nrepresents the value of the INDEX field for a
Tags entry in the SNMPVARS.DBF file.

You should never directly modify the Tag database. All Tags should be entered
using the procedure specified in the section titled Setup Guide.

For each Tag, you may specify the Citect Data Type you require, however you
must ensure that the selection you make is appropriate for the corresponding
SNMP Object.

Note that Tags with a Citect Data Type of STRING, are limited to a maximum
length of 255 characters. For Tags with a required numeric range which goes
outside the range 2147483648 to 2147483647, you could assign a Citect Data
Type of REAL.

Na & Ra Grouping Considerations Citect will allow you to group enquiries


together to enable greater SNMP efficiency. The user must decide which items need
to be grouped together. It is recommended no more than 20 items are grouped
together. This means if any one item is read, the whole group will be read.
This can be a manual process or done with the Citect MIB2CIT utility. Groups
should be seperated in units of 100. E.g. N0,N2,N3 then N100, N101, etc.

MIB Table Support A SNMP MIB often has tables which cover multiple instances
of some device. To allow Citect to be flexible and not require hard coding, v2.0.5+
of the SNMPII driver adds TABLE support.
The user maps the TAG name to the table OID number, e.g.
ifMtu is 1.3.6.1.2.1.2.2.1.4 in the ifEntry Table (1.3.6.1.2.1.2.2.1)
Tag Name ifMtu, OID 1.3.6.1.2.1.2.2.1.4
In Citect this is referenced to using the array notation as ifMtu[2] . This translates
in the driver to 1.3.6.1.2.1.2.2.1.4.2 .
The OID stored in the database will be 1.3.6.1.2.1.2.2.1.4.x . The default case is .1
or 1.3.6.1.2.1.2.2.1.4.1 . x can be between 1 and 255.

1.1.8 Reference: SNMP Traps

SNMP Traps differ from other SNMP messages in one important respect. They are
unsolicited messages sent by an SNMP agent when some pre-defined event has
occurred. For that reason, the SNMPII driver in Citect handles traps in a slightly
different way to other SNMP variables. Because there is no way of knowing in

Copyright 1999 Ci Technologies Page: 10


Citect for Windows, V5.xx SNMP Driver

advance how many traps will be received by Citect, it is impossible to set up


Variable Tags ready for each trap. Instead, incoming traps are queued.

1.1.8.1 Trap Reading

A single set of seven tags, addressed as T0, T1, , T6, is used to read the traps
one by one from the queue. These seven tags are assigned data from each trap
according to the following table:

Tag Address Field of trap object assigned to Tag


T0 Enterprise (device sending the trap).
Eg. 1.3.6.1.4.1.311.1.1.3.1.1
T1 IP address
Eg. 223.125.1.17
2
T2 Generic type
Eg. 6
T3 Specific type (i.e. a user defined trap in
the enterprise MIB) Eg. 3
T4 Time stamp
Eg. 6336403
T5 OID of Name of the first trap varbind in
varbindings
Eg. .1.3.6.1.2.1.1.5.0
T6 Value of the first trap varbind in
varbindings. Eg. Computer_1.
When writing T6, the 2nd parameter
needed must be either INTEGER,
COUNTER, GUAGE, TIMETICK,
ADDRESS, STRING
TF Forward trap to IP address. An optional
trap community name can be added to
the 2nd argument. E.g. 196.168.1.34
trap
TN Trap next (read or write)
TNVB Mutiple trap variable(read or write)

To read data from the next trap in the queue, a tag TN write is performed.
Note that once a trap has been removed from the queue, the trap cannot be re-
read. When no traps exist, the Tx tags are returned as nulls.

1.1.8.2 Trap Forwarding

Should a trap need to be forwarded to another system, Cicode must be written to


use the TFtag BEFORE using TN.. E.g. TF=203.168.34.23.

2
Generic type Values
0 Cold Start
1 Warm Start
2 Link Down
3 Link Up
4 Authentication Failure
5 egpNeighour Loss
6 enterprise specific trap

Copyright 1999 Ci Technologies Page: 11


Citect for Windows, V5.xx SNMP Driver

s are allowed so that several destinations can be used. If no 2nd


Multiple TF
argument is given, the default of trapis used to send the trap.

1.1.8.3 Trap Creation

Traps can be created by writing to T0-T6 with data, then using the TF as before.
This enables non SNMP devices to be able to generate traps via Citect.
When creating a trap, T0--T4 are set to their default values, T5 and T6 are empty.
Default values:
T0 Enterprise: .1.2.3.6.1.311.1.1
T1 IP address: local IP address
T2 GenType: 6
T3 SpecType: 0
T4 TimeStamp: time since driver was started, in 100th of seconds.

When T5 is assigned a value and T6 is empty, T6 is set to "0 INTEGER"


When T6 is assgned a value and T5 is empty, T5 is set to ".1.3.6.1.2.4.2.0"
Note, when writing to T6, you need to describe the data type. This is documented
in the previous table.

1.1.8.4 Mutiple trap


If TNVB has not been read or written to, the addressed as T0, T1, , T6, is used to
read the first traps from the queue. A read of TNVB returns the number of varbinds
in the trap queue. A write to TNVB controls which varbind data is going to be read
or written to.

1.1.9 Reference: An alternative SNMP Port


Two citect.ini parameters
[snmpii]
changeports2000=1 ! or enablechangeports=1
PortName.UnitName.Port=***(the default being 161)

will allow alternative port to be used. In the Beta version this could be used on a
win2000 platform. The status under NT4 is not guaranteed to work.
Please note to enable this feature, it was necessary to ship a Win 2000 mgmtapi.dll
to be placed under \citect\bin so the NT4 users did not get DLL dependency issues.
The user must ensure the port isn t used or likely to be used by other processes.

1.1.10 Hints, Tips, and Frequently Asked Questions

You should be aware that there are several reported problems related to the
operation of SNMP in Microsoft Windows NT4.0/98/95 environments. Some of those
pertaining to Windows NT 4.0 have been fixed. If you experience problems with the
use of the Citect SNMPII Driver, you should become familiar with the reported
problems, bugs, fixes and work arounds currently published. See the section titled
SNMP Related Bugs in Windows NT/98/95 for mode details.

If the SNMP service is installed on a PC running Windows 95, the service will not
function correctly until the file: INETMIB1.DLL, is copied from the installation folder
to the WINDOWS\SYSTEM folder.

Copyright 1999 Ci Technologies Page: 12


Citect for Windows, V5.xx SNMP Driver

Note that Trap data types can only be used on IP networks. Trap data is treated as
global and stored in a queue in this driver, i.e. the Trap variable could be defined
under any IO device and those trap variables with same address (such T0) will
have the same value. A read will get the variable value from the first elements of
the queue and writing will delete that first element from the queue. The length of
the queue is only limited by available memory.

The SNMPII driver WILL NOT work on a PC running Windows 98 or 95. Windows
NT (Server or Workstation) 4.0 or greater is required. The latest service pack is
highly recommended. However when used on Windows NT, the Citect SNMPII
driver CAN communicate to PCs running Windows 98/95 running SNMP agents.

Before the first writing to a variable, at least one read must be made so
that the driver can get the SNMP data type of that variable.

Screenshot of the Tag Properties Dialog from the MIB2CIT Utility

Copyright 1999 Ci Technologies Page: 13


Citect for Windows, V5.xx SNMP Driver

Screenshot of the Variable Tags form in Citect Project Builder

Note how the entries in the fields of the Variable Tags form correspond to the
entries in the SNMPVARS.DBF file defined for the port the device is on. In
particular note how the Address field is a combination of the INDEX and SNMPTYPE
entries in the SNMPVARS.DBF (as can be seen from the Tag properties dialog
shown above).

The following picture shows how a Trap tag is set up in a Variable Tags form:

Screenshot of the Variable Tags form in Citect Project Builder

It is possible for many tags to refer to same Address tag as tags on different I/O
Device Names talk to different SNMP agents. Note also that the I/O Device field
could be changed to refer to any other I/O device that has been set up for SNMP
communications.

To read traps from the queue and log them for future reference, the following logic
could be followed.

1) Read Tag TN to see if it is > 0..


2) If TN is 0 then there are no traps in the queue. Exit the process.
3) Read required data from Tag Tx (where x is any one value from 0 6)

4) Log the values of the Tx or store them in other variables


5) If the trap needs to be forwarded, then write Tag TF with the forwarding IP
address.
6) Write to TN to delete the current trap and move the traps in the queue forward.
7) Return to step 1

Default value of TF is 127.0.0.1

1.2 Driver reference

Detail
Driver name SNMP
Maximum array size3 2040 bits (255 bytes)

3
Equivalent to
Maximum Request Length

Copyright 1999 Ci Technologies Page: 14


Citect for Windows, V5.xx SNMP Driver

Max_Block 640 bits or 20 reals or integers

1.2.1 Description

The Citect SNMPII driver is used to communicate via Ethernet UDP/IP to any SNMP
manageable devices connected to a network.

1.2.2 Driver generated error codes

Driver Error Code Mapped to (Generic Error Label) Meaning of Error Code
(Hexadecimal)
0x101 GENERIC_GENERAL_ERROR The response was too large for
the agent to handle
0x102 GENERIC_BAD_PARAMETER The requested OID does not
exist in supported MIB view, or
is not accessible, or we
attempted a write operation on
a read-only MIB variable
0x103 GENERIC_BAD_PARAMETER Bad MIB variable data type
specified in variable bindings
0x104 GENERIC_WRITE_PROTECT Attempted a write operation on
a read-only MIB variable (this
error never occurs)
0x105 GENERIC_GENERAL_ERROR An unknown error.
0x180 GENERIC_NO_MEMORY No memory could be allocated.
0x181 GENERIC_GENERAL_ERROR Could not convert an OID string
into a valid OID

1.2.3 Parameters, options and settings

Standard Parameters

Parameter Default Allowable values


Block (bytes) 4 4 to 255. Not used.
Delay (mS) 0 0 to 300
MaxPending 2 1 to 5
Polltime (mS) 1000 500 to 2000
Timeout (mS) 1000 1000. Not used.
Retry Not used
WatchTime (Sec) 30 0 to 128s

Driver Specific Parameters

Parameter Default Allowable values


MaxTimeouts 1 1 to 3 of requests to SNMP API
SnmpTimeout(mS) 1000 200 to 6000. Timeout internal to SNMP API
SnmpRetry 1 1 to 5. Count internal to SNMP API.
PDUGroupOK 20 0 to disable grouping. >1 to enable
grouping. This value cannot exceed 98 and

Copyright 1999 Ci Technologies Page: 15


Citect for Windows, V5.xx SNMP Driver

is recommended to be 20.
ExtraDebug 0 O or 1 Extra debug statements for
determining errors. Debug flags need to be
enabled.
ReturnError 0 or 1 To be used in conjunction with
PDUGroupOK to isolate the variable in a
group of tags that is causing an error.
When this parameter is set to 1, the driver
returns an error when an SNMP packet is
returned with an error. When set to 0, the
driver returns either the string Bad or
the number 2898 (oxBAD).
x.y.TestOIDStr Test OID
(where x is portname, String The SNMPII driver tests the status of each
y is the unitname) Citect I/O Device by transmitting a request
to read the sysDescr
(.1.3.6.1.2.1.1.1.0) object in the device.
TestOIDStr will allow alternative OID to be
used for testing the status of each Citect
I/O Device. An OID must end with .0. If
the I/O device is online, it will respond by
transmitting the requested data. If no
response is received, then the Citect I/O
Device will be considered offline.

ChangePorts2000 or 0 or 1 Default 0, Only change if you are on a


EnableChangePorts Win2000 machine and you wish to change
the default port.
x.y.Port Any Allows the default SNMP port (the default
(where x is portname, is 161) to be changed. Your SNMP agent
y is the unitname) must be able to listen on the new port
number !

ComSettingsInInclude 0 or 1 Default 0, this needs to be set to 1 IF the


SNMPVARS.DBF information is going to be
in Communication Settings in INCLUDE
projects.

For most users, the ReturnError parameter is likely to be the only one they will
use. The others relate to specialised setups.
When PDUGroupOK is 0 or 1, separate SNMP packets will be generated for each
item asked by the IOServer. When non zero, items in one request from IO Server
will be requested in one packet to target device.
NB: The target device MUST be able to support large PDU packets if PDUGroupOK
is high. Some devices may crash if this value is too large. 50 worked on NT
workstations but crashed a 3rd party box.

Hint: When an error occurs in reading one item in a group, all items are flagged as
errored. To establish which item is causing the error, set PDUGroupOK=1, so that
the driver sends a separate SNMP packet for each item, and ReturnError=0, so that
the driver does not return an error to the IO Server. Then the item which is
causing the problem will be displayed with the value Badif it a string or the value
2989 (the decimal equivalent of the hex 0xBAD) if it is numeric. Once the problem
item has been located, always remember to set ReturnError back to 1, so that
further errors generate #COM.

Copyright 1999 Ci Technologies Page: 16


Citect for Windows, V5.xx SNMP Driver

1.2.4 Advanced

Driver generated statistics


Number Label Description
0 Rd Req Number of read requests from Citect but
excludes trap requests
1 Rd Ok Number of successful read requests
2 Wrt Req Number of write request from Citect but
excludes trap writes
3 Wrt Ok Number of successful write requests
4 Sent Packets Number of packets sent.to SNMP agent
5 PDUGroupOK Value of PDUGroupOK
6 All traps Number of received traps
7 Traps in queue Number of traps in the queue
8 Traps Rd Number of trap read requests
9 Traps Wrt Number of trap write requests

When PDU grouping occurs, the packet count will be less than the number of
desired reads and writes. The difference gives the developer an indication of how
well the groupfeature is working.

Debug messages

Data Read
Mon Jun 05 11:08:50 2000 02:31:28.986 StartTransmit Length 0
Mon Jun 05 11:08:50 2000 02:31:28.986 Transmit Chk 00000000 Length 0
Mon Jun 05 11:08:50 2000 02:31:28.989 Read Request Addr:2 020E75F8 1 Length
0
Mon Jun 05 11:08:50 2000 02:31:28.990 Request Finish. Thread Will Suspend.
Addr:2 Length 0

Data Write
Mon Jun 05 14:19:49 2000 00:23:04.493 Write Request Addr:56 020E75F8 1
Length 0
Mon Jun 05 14:19:49 2000 00:23:04.495 Request Finish. Thread Will Suspend.
Addr:56 Length 0

In the above messages, the Addr:2 or Addr:56 means the variable address (index
in the SNMPVARS.DBF file) is 2 or 56. The following hexadecimal string is the
pointer of the corresponding DCB and the following 1 is the returned value of
ResumeThread() function.

Copyright 1999 Ci Technologies Page: 17


Citect for Windows, V5.xx SNMP Driver

2. Analysis
2.1 Overview

SNMP is a request-and-response protocol. An SNMP manager sends a request to an


agent. The agent replies with a response that indicates if the operation was
performed successfully or if an error occurred.

Each SNMP operation has its own type of message. Each of these messages is used
by a management system to request that an operation be performed on managed
variables maintained by an SNMP agent. There are three request and response
operations: Get, GetNext, and Set. A fourth operation, Trap, is an unsolicited
message sent by an agent; it therefore does not have a corresponding request
message. Trap messages can be generated for changes such as host system
startup, shutdown, or password violation. Trap destinations can be configured by a
user, but the occurrences which generate a trap message are internally defined by
the SNMP agent.

[The Citect driver does NOT support the GetNext request.]

SNMP uses a distributed architecture consisting of managers and agents. A


manager is an SNMP application that generates queries to SNMP agent
applications and receives traps from SNMP agent applications. An agent is an
SNMP application that responds to queries from SNMP manager applications. The
SNMP agent is responsible for retrieving and updating local management
information based on the requests of the SNMP manager. The agent also notifies
registered managers when significant events or traps occur.

A managed node is any network device that is capable of being managed. A


management node is typically a workstation or server on a network that is
running one or more network management software applications. Every managed
node is a member of one or more management communities; each community is
identified by a human readable name called a community name, or a community
string when it is encoded in an SNMP message. A node that does not belong to one
or more specific communities is said to belong to all management communities.

If the agent is running on the node that it is actively managing, the node is said to
support SNMP management. If the agent is not running on the node that it is
managing, then the agent is described as a proxy agent because it is managing a
node that cannot locally support SNMP management, or perhaps network
connectivity itself.

The Microsoft SNMP service is itself a proxy agent for any manageable devices
accessible by a Windows workstation, such as modems, printers, and network
interface controllers. A proxy can also be used to manage software processes that
are running in the Windows operating system without the processes explicitly
supporting SNMP.

SNMP network management itself is composed of three parts:

SNMP Protocol specifies the behaviour of the Get, GetNext, Set, and Trap
operations, and defines the format of the SNMP messages exchanged by managers
and agents.

Copyright 1999 Ci Technologies Page: 18


Citect for Windows, V5.xx SNMP Driver

Structure of Management Information (SMI) the set of rules used to specify


the format used for defining managed objects that are accessed via the SNMP
protocol.

Management Information Base (MIB) the map of the hierarchical order of all
managed objects and how they are accessed.

All management operations are performed on managed objects, also called MIB
objects. Each object represents data with a specific set of attributes, and can be
manipulated using Get, GetNext, or Set operations. The Trap operation is merely
an event report.

The MIB and the SMI are expressed using a text-based data description notation
known as Abstract Syntax Notation One (ASN.1). ASN.1 notation provides an
unambiguous and hardware independent description of data in an ASCII text
format. Basic Encoding Rules (BER) provides the same function, but encodes
messages in a binary format suitable for transmission across a network.

2.2 Versions of SNMP

There are presently two major versions of SNMP: SNMPv1 and SNMPv2. SNMPv1 is
a recommended standard protocol and part of the Internet Management
Framework. SNMPv2 is intended to be an update of SNMPv1, adding several
features purposely omitted from SNMPv1 to expedite its acceptance and release.

SNMPv2 itself has three different types:

?? SNMPv2u - with user based security.


?? SNMPv2* - with user based security and additional features.
?? SNMPv2c - without security.

SNMPv2c has the endorsement of the IETF but has no security and administration
whereas both SNMPv2u and SNMPv2* had security but lack the endorsement of the
IETF. There is also an SNMPv3 development effort currently underway. The
creation of SNMPv3 resulted from the Internet Engineering Steering Group (IESG)
mandating the formation of an SNMP advisory group to unify the concepts and
mechanisms of SNMPv2u and SNMPv2* into a single protocol with strong security.

At this time, only the SNMPv1 protocol has widespread usage. The SNMPv1
protocol is most likely found in every managed device and management platform
that supports SNMP.

This driver implements version SNMPv2c as this is the version in the Windows NT
SNMP server.

2.3 Packet Transmission

SNMP uses the connectionless UDP transport protocol. An SNMP agent must
establish connectionless sessions to listen for SNMP request messages and send
responses. Under Windows NT, the WinSock API is used to establish a
management session by dynamically creating a socket (an end-point in a network
connection) using the specific protocol port reserved for SNMP.

Copyright 1999 Ci Technologies Page: 19


Citect for Windows, V5.xx SNMP Driver

The following figure shows the location of SNMP and its associated protocols within
the OSI network layer model.

7 Application Layer Management and Agent APIs


SNMP
6 Presentation Layer ASN.1 and BER
5 Session Layer RCP and NetBIOS
4 Transport Layer TCP and UDP
3 Network Layer IP and IPX
2 Data Link Layer Ethernet, ARCNet, and Token Ring
1 Physical Layer

Fig 2.1 SNMP and the OSI model

SNMP itself is implemented by software applications residing in the application


layer. SNMP requires the services of the presentation layer (ASN.1 and BER) to
render management data in a form that is suitable for transportation across a
network, and allows it to be correctly interpreted regardless of the type of network
device that receives it. UDP/IP encompasses the transport and network layer
services used with SNMP.

Data is passed from one OSI layer to another in discrete blocks called protocol
data units (PDU s). A PDU is a logical designation for the data in a packet that is
used by a specific OSI layer or protocol. Before data can be transported across a
network, it must be passed down the network stack, and encapsulated using the
PDU formats defined at each layer. Each PDU is placed in the envelope of the next
PDU until it reaches the physical layer, where it is sent out to the network. When
the message reaches its destination, it must be decapsulated before the data in
the message can be used.

The next figure shows an SNMP message encapsulated in the envelopes it would
need, to be transported across an Ethernet network using UDP/IP.

Ethernet IP UDP SNMP CRC


Frame Packet Datagram Message

Fig 2.2 An SNMP message and its network envelopes

The outermost envelope is used to identify the data link layer mechanism, which is
Ethernet. The next envelope, IP, handles the actual routing of the message from
node to node across the network. The UDP envelope indicates which protocol port
on the receiving host should be used to receive the message. And the SNMP

Copyright 1999 Ci Technologies Page: 20


Citect for Windows, V5.xx SNMP Driver

message itself is recognised not only by the port at which it is received, but also by
the information it contains.

Application layer processes that handle PDUs are called network services, and
are identified by their assigned port numbers. SNMP uses two ports: 161 and
162. Port 161 receives all SNMP request messages. If an SNMP manager wants to
send an SNMP request message to an agent, it specifies port 161 as the destination
port in the UDP header. The SNMP response message is sent by the agent to the
same port used by the SNMP manager to send the request message. User can also
use a port other than 161 to receive all SNMP request message, this only can be
used on the Windows2000 platform.

Port 162 is the SNMP trap port. When an SNMP agent needs to send a trap to an
SNMP manager, it specifies the destination as port 162 in the UDP header. The
SNMP manager understands that all messages arriving via port 162 are SNMP Trap
messages.

2.4 Object Identifiers

Each object in a MIB is identified by a universally unique label referred to as an


object-identifier (OID). The OID includes the object s type (such as counter,
string, gauge, or address), the object s access level (such as read / write), size
restrictions, and range information. The OID is internationally accepted and allows
developers and vendors to create new components and resources and assign a
unique OID to each new component or resource.

The object name space is implemented as a multi-part, hierarchical, naming


scheme. A hierarchical naming scheme can be viewed as an inverted tree with the
branches pointing downward. Each point where a new branch is added is referred
to as a node. Each node is enumerated using an unsigned 32-bit integer called a
sub-identifier.

The OID in the hierarchy is written as a sequence of sub-identifiers beginning at


the root and ending at the object. Sub-identifiers are separated with a period. For
example, the OID for sysDescr which is a textual description of the SNMP
manageable device is : .1.3.6.1.2.1.1.1.0

The following diagram illustrates a part of a MIB tree.

Copyright 1999 Ci Technologies Page: 21


Citect for Windows, V5.xx SNMP Driver

.1
International Standards Organisation (ISO)

.3
Organisation (ORG)

.6
Department of Defence (DOD)

.1
Internet

.1 .2 .3 .4
Directory Mgmt Experimental Private

.1 .1
MIB-2 Enterprises

.311 .437
Microsoft Cisco

.1
Software

.1 .2 .3
Systems Wins Dhcp

Fig 2.3 OID Hierarchy Sample

The OID naming scheme is governed by the Internet Engineering Task Force
(IETF). The IETF grants authority for parts of the name space to individual
organizations, such as Microsoft. For example, Microsoft has the authority to assign
the OIDs that can be derived by branching downward from the node in the MIB
name tree that starts at .1.3.6.1.4.1.311.

2.5 Data Types

All managed objects defined under SNMP are based on the three ASN.1 UNIVERSAL
types:

INTEGER - A signed whole number with no specific size limit,


although most SNMP implementations define
INTEGER s to be signed or unsigned 32-bit
numbers.

OCTET STRING - A sequence of octets, where each octet is defined


as an 8-bit byte. The sequence may be printable
ASCII characters or arbitrary binary data.

OBJECT IDENTIFIER - Stores the location of a variable (managed object)


within a MIB. The location is stored as an array of
16-bit unsigned integers called sub-identifiers.

Copyright 1999 Ci Technologies Page: 22


Citect for Windows, V5.xx SNMP Driver

ASN.1 allows re-definition of data types (analogous to typedefin C), and also sub-
typing, whereby explicit range restrictions can be applied.

2.6 Managed Objects

Each managed object is defined in a MIB module using the OBJECT-TYPE macro as
defined by SMIv1. The object may be scalar and have only a single instance, or it
may be columnar and have zero or more instances.

The following is the


sysContactobject defined in MIB-II, and is a typical definition
of a scalar MIB variable:

sysContact OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read -write
STATUS mandatory
DESCRIPTION
"The textual identification of the contact person
for this managed node, together with information
on how to contact this person."
::= { system 4 }

The sysContactlabel is the name or object descriptor of the variable and OBJECT-
TYPE is the macro. The attributes of the object are described by the following four
clauses which are defined by OBJECT-TYPE in RFC1155. (A Request For
Comments, or RFC is an offical specification for Internet standards. All RFCs are
created, reviewed, and updated by the Internet Activities Board (IAB), and the
Internet Engineering Task Force (IETF)). The attributes are as follows:

SYNTAX - is the data type of the object and includes any range restrictions.

ACCESS - describes the current access mode of the object, which can be
either read-only, read-write, write-only, or not-accessible.

STATUS - describes the current need and validity of the object. The possible
values are:

Mandatory - must be implemented by an agent, and the values


that they contain are valid for use.

Optional - may or may not be implemented by an agent.

Deprecated - these objects are in transition to Obsolete status.


They have been replaced by newer objects, but the
data contained may still be valid.

Obsolete - no longer supported by the MIB and should not be


implemented by an agent.

DESCRIPTION - is a human-readable string that describes the purpose of the


object and how it is to be used.

MIB registration registration value is an OBJECT IDENTIFIER(OID). So in the


example, ::= { system 4 } would map the OID of sysContact
to 1.3.6.1.2.1.1.4 where 1.3.6.1.2.1.1 is the location of the
system group in the internet branch of the MIB naming tree.

Copyright 1999 Ci Technologies Page: 23


Citect for Windows, V5.xx SNMP Driver

2.7 SNMP Packets

SNMP managers and agents are not required to support messages of greater than
484 bytes in length. Agents implemented on very small systems may strictly abide
by this rule, but most network management systems are implemented on PC
workstations may handle much larger messages (typically 1500 bytes).

Each request or response message may contains one or more variable bindings
(varbinds). Variable bindings are so named because they bind an OID name with a
value. The OID is that of a single managed object defined in a MIB. The value may
be any of the ASN.1 scalar data types defined by the SMI for use with SNMP, or the
ASN.1 NULL value if the value field is not used. If a value is specified, its data type
must match that of the object whose OID is specified in the same binding. The size
of each binding is variable. The number of bindings that may be included in any
PDU is also variable, with no set limit.

SNMP guarantees that the order of the varbinds in a response message will be the
same as in the corresponding request message.

If an operation on one of the varbinds fails, then none of the values requested are
returned. Instead, the varbind list of the response message will be an exact
duplicate of the request message. Thus it is very important that a system be tested
without any blocking first, before grouping is enabled to ensure each read or
write will work under normal conditions.

2.8 Microsoft SNMP API & SNMP Management API

Both Windows NT and Windows 98/95 support the SNMP agent service
(SNMP.EXE). Only Windows NT however, supports the Microsoft SNMP
Management API (MGMTAPI), along with the SNMP Trap Service
(SNMPTRAP.EXE) (for receiving traps). MGMTAPI allows both Windows
applications and MS-DOS Console applications to send GetRequest,
GetNextRequest, and SetRequest messages, and to receive GetResponse and
trap messages.

The SNMP agent service supports most, but not all objects defined by MIB-II.
These objects are implemented in the file INETMIB1.DLL.

SNMP manager applications developed using MGMTAPI make use of the Microsoft
SNMP API (SNMPAPI) for memory allocation and data manipulation. The Microsoft
SNMP API s were still undergoing development as at November 1999. Both
SNMPTRAP.EXE and MGMTAPI interface to the WinSock API for all network
communications required by the manager application.

2.8.1 Management Functions

The set of management functions used for implementing SNMP manager


applications are located in MGMTAPI.DLL. Their prototypes are found in
MGMTAPI.H. The functions are linked using MGMTAPI.LIB.

The management functions are as follows:

Copyright 1999 Ci Technologies Page: 24


Citect for Windows, V5.xx SNMP Driver

Function Usage
SnmpMgrClose Closes a network socket connection with an agent
SnmpMgrGetTrap Retrieves buffered trap data from an agent
SnmpMgrOidToStr Converts an AsnObjectIdentifier to an OBJECT IDENTIFIER
SnmpMgrOpen Opens a network socket connection to an agent
SnmpMgrRequest Sends a Get, GetNext, or Set request to an agent
SnmpMgrStrToOid Converts an OBJECT IDENTIFIER to an AsnObjectIdentifier
SnmpMgrTrapListen Registers a management application to receive traps
Set an operating parameter associated with an SNMP session, this is
SnmpMgrCtl
for setting port (WIn 2000 API)

Table 2.8.1 SNMP Management API Functions

2.8.2 Utility Functions

The set of utility functions used by SNMP manager applications are prototyped in
SNMP.H; the functions themselves are located in SNMPAPI.DLL, and they are
linked using SNMPAPI.LIB.

The utility functions are as follows:

Function Usage
SnmpUtilAsnAnyCpy Copies an AsnAny variable and allocates the required storage
SnmpUtilAsnAnyFree Frees the memory allocated for an AsnAny variable
SnmpUtilDbgPrint Prints debug messages to log file
SnmpUtilMemAlloc Allocates memory
SnmpUtilMemFree Frees allocated memory
SnmpUtilMemReAlloc Reallocates memory
SnmpUtilOctetsCmp Compares two AsnOctetString variables
SnmpUtilOctetsCpy Copies an AsnOctetString variable and allocates the required storage
SnmpUtilOctetsFree Frees the memory allocated for an AsnAny variable
SnmpUtilOctetsNCmp Compares two AsnOctetString variables
SnmpUtilOidAppend Appends AsnObjectIdentifier
SnmpUtilOidCmp Compares AsnObjectIdentifier objects
SnmpUtilOidCpy Copies an AsnObjectIdentifier object
SnmpUtilOidFree Frees an allocated AsnObjectIdentifier object
SnmpUtilOidNCmp Compares N number of AsnObjectIdentifier OID sub-identifiers
SnmpUtilPrintAsnAny Prints an AsnObjectIdentifier value to the standard output
SnmpUtilVarBindCpy Makes a copy of an RFC1157VarBind object
SnmpUtilVarBindFree Frees an allocated RFC1157VarBind object
SnmpUtilVarBindListCpy Makes a copy of an RFC1157VarBindList object

Copyright 1999 Ci Technologies Page: 25


Citect for Windows, V5.xx SNMP Driver

SnmpUtilVarBindListFree Frees an allocated RFC1157VarBindList object


SnmpSvcGenerateTrap Generate Enterprise trap

Table 2.8.1 SNMP Utility API Functions

2.9 Glossary

API Application Programming Interface


ASN.1 Abstract Syntax Notation One
BER Basic Encoding Rules
IETF Internet Engineering Task Force
IP Internet Protocol
IPX Internet Packet Exchange
MIB Managament Information Base
OID Object Identifier
PDU Protocol Data Unit
RFC Request For Comments
SMI Structure of Management Information
SNMP Simple Network Management Protocol
TCP Transmission Control Protocol
UDP User Datagram Protocol

Copyright 1999 Ci Technologies Page: 26


Citect for Windows, V5.xx SNMP Driver

Copyright 1999 Ci Technologies Page: 27


Citect for Windows, V5.xx SNMP Driver

3. Driver implementation
3.1 Development resources

3.1.1 Contacts

Greg Roberts
Lead Citect Driver Developer
Ci Technologies Pty Ltd
E-mail: GregRoberts@cit.com.au
Ph : +61-2-9855-1000

3.1.2 Documents

1. Windows NT SNMP, Murray, James D., O


REILLY, 1998.

2. Citect for Windows Driver Specification SNMP Driver, Dowideit, Sven, 20 Nov.
1996.

3. SDK Documentation: Platform SDK: Networking and Distributed Services:


Simple Network Management Protocol, Microsoft Corporation, MSDN Jul.
1998/99.

4. Windows Resource Kits: MS Windows NT Server 4.0 Resource Kit: MS Windows


NT Server 4.0 Networking Guide: Chapter 11 - Using SNMP for Network
Management, Microsoft Corporation, MSDN Jul. 1998/99.

5. Windows Resource Kits: MS Windows NT Server 4.0 Resource Kit: MS Windows


NT Server 4.0 Networking Guide: Appendix C MIB Object Types for Windows
NT, Microsoft Corporation, MSDN Jul. 1998/99.

6. RFC: 1155 - Structure and Identification of Management Information for


TCP/IP-based Internets, Rose, M. & McCloghrie, K., Internet Engineering Task
Force, May 1990.

7. RFC: 1157 A Simple Network Management Protocol (SNMP), Case, J., Fedor,
M., Schoffstall, M., & Davin, J., Internet Engineering Task Force, May 1990.

8. RFC: 1213 Management Information Base for Network Management of


TCP/IP-based Internets: MIB-II, McCloghrie, K. & Rose, M., Internet
Engineering Task Force, Mar. 1991.

9. Understanding OSI Network Management, Stallings, William, Dr. Dobb


s
Journal, Dec. 93.

10. Abstract Syntax Notation One (ASN.1), Witten, Steve, Dr. Dobb
s Journal, Nov.
94.

11. Simple Network Management Protocol (SNMP) Current Standards and Status,
Cekro, Z., Universite Libre De Bruxelles, Faculte De Sciences, Mar. 1998

Copyright 1999 Ci Technologies Page: 28


Citect for Windows, V5.xx SNMP Driver

3.1.3 Software / Hardware


3.1.3.1 Software

The Citect 5.xx SNMPII Driver will only function on a PC running Microsoft Windows
NT (Server or Workstation) 4.0; Service Pack 6 or higher is recommended. The
SNMPII driver WILL NOT work on a PC running Windows 98 or 95.

A PC used as an SNMP host i.e. (as a Citect I/O Device) may use either Windows
NT 4.0 or Windows 98/95. In this case, the TCP/IP protocol, and the SNMP service
will be required. These software components are included on the Microsoft
Windows NT/98/95 CD.

3.1.3.2 Hardware

If a PC is to be used as an SNMP host, a TCP/IP compatible network card will be


required.

3.2 Risk areas

SNMP related bugs In Windows NT.

3.3 Development plan

The SNMPII Driver is to be developed in MS-Visual C++ 6.0, and its target
operating platform will be Citect 5.21 running on MS-Windows NT Workstation 4.0.
Users of the initial release of the driver will be required to manually enter the OID
s
for each of the SNMP Objects to be monitored.

It is proposed that a future version will feature an OID selection tool with some
kind of graphical user interface to ease the OID selection process. This tool will use
as input, the *.MIB files that are normally supplied by harware vendors of SNMP
manageable devices.

3.4 Beta testers

None
??

Copyright 1999 Ci Technologies Page: 29


Citect for Windows, V5.xx SNMP Driver

4. Appendix

4.1 v1 SNMP Manual setup guide

Step 1
Create a new Citect Project by selecting File | New Project from Citect Explorer,
then from the Citect Project Editor, select Communication | Express Wizard to
configure communications. You will then need to add entries to the I/O Devices
form for each device to be monitored by Citect. The IP address of each device must
be entered in the Addressfield of this form. After entering the IP address, leave
one space, then enter the name of the SNMP management community to which
the device belongs. If no specific communities are defined for the device, or you
are unsure, enter publicwithout the quotes.

Step 2
Create Tags for the SNMP objects to be monitored. The procedure for this is as
follows:

(a) Using a plain text editor, such as Windows Notepad, enter the details for all the
required Tags (except Trap Tags) in the following format (using one line for
each entry):

INDEX,DEVNAME,TAGNAME,CTYPE,OID,SNMPTYPE,R/W,[RZS],[RFS],[EZS],[EFS],[EUNIT],[FORMAT],
[COMMENT],[{num Text}{num Textrepeated}]

Each field is described in the Table below.

Field
Description
Name
A unique index number. You must begin with 0, and increment this
INDEX
value for each subsequent entry.
A unique descriptive name given to each Citect I/O Device, as specified in
DEVNAME
the I/O Devices form. It must not exceed 16 characters in length.
A unique descriptive name given to each Tag, and must not exceed 32
TAGNAME
characters in length.
The Citect Data Type of the object, which can have one of the following
values:
LONG, REAL, STRING
CTYPE
Note that Tags with a Citect Data Type of STRING, are limited to a
maximum length of 255 characters.
For Tags with a required numeric range which goes outside the range:
2147483648 to 2147483647, you could assign a Citect Data Type of REAL.
OID The SNMP Object Identifier, e.g: .1.3.6.1.2.1.1.1.0
The Citect SNMP data type, and can have one of the following values:
DA - for alphanumeric string objects(octet string processed as null-
terminated string)
BA - for alphanumeric string objects(octet string processed as binary
SNMPTYPE string)
N - for numeric objects (treat as long in Citect)
NE - for enumerated numeric objects (this is equivalent to the N type
but indicates that Cicode macros should be generated using the
MIB2CIN.EXE utility). NE objects always have the ENUMS field[s] defined.

Copyright 1999 Ci Technologies Page: 30


Citect for Windows, V5.xx SNMP Driver

R - for numeric objects(treat as real in Citect)


The readability/ write-ability of the tag, which can have one of the
following values:
R/W
R - Read Only
W - Write Only
RW - Read and Write
RZS RAW ZERO SCALE, an optional field.
RFS RAW FULL SCALE, an optional field.
EZS ENGINEERING ZERO SCALE, an optional field.
EFS ENGINEERING FULL SCALE, an optional field.
EUNIT ENGINEERING UNIT, an optional field.
FORMAT ENGINERRING FORMAT, an optional field.
An optional comment, which must not exceed 48 characters in length. Any
COMMENT
commas within this text must be removed.
Enumerated values for the OID. These are data pairs of :
ENUMS {number1 Text1}{number2 Text2}
This data is not used by the driver

Note 1: for optional fields, the commas (,) MUST be included in each line, but
DO NOT include the square brackets ( [ ] ).
Note 2: for detail of DA or BA, refer to 1.1.6 Refernece: DataTypes

(b) Save the file as VARIABLE.CSV in the Citect project folder e.g.
Citect\User\SNMP\VARIABLE.CSV

(c) From Citect Project Editor, select Communication | Ports, then in the Special
Opt field, enter the name of the file created in the previous step, i.e.
VARIABLE.CSV

(d) For each tag in the file VARIABLE.CSV, fill out a Variable Tag form to reflect the
data in the CSV file (Tags | Variable Tags in Citect Project Editor). Fill in each
field as follows:
Field Value
Variable Tag Name The value of TAGNAME in the file VARIABLE.CSV
Data Type The value of CTYPE in the file VARIABLE.CSV
I/O Device Name The value of DEVNAME in the file VARIABLE.CSV
Address Sn where S is the value of SNMPTYPE in the file
VARIABLE.CSV and n is the value of INDEX.
Raw Zero Scale The value of RZS in the file VARIABLE.CSV
Raw Full Scale The value of RFS in the file VARIABLE.CSV
Eng Zero Scale The value of EZS in the file VARIABLE.CSV
Eng Full Scale The value of EFS in the file VARIABLE.CSV
Eng Units The value of EUNIT in the file VARIABLE.CSV
Format The value of FORMAT in the file VARIABLE.CSV
Comment This field is user defined and is not used by the driver
(e) If SNMP traps are to be monitored, seven extra Citect Variable Tags must be
created, one for each of the Enterprise, Agent IP Address, Generic Trap Type,
Specific Trap Type, and Time Stamp trap fields and one each for the OID and
value of the first variable binding. See Section 1.1.8 for further details.

Copyright 1999 Ci Technologies Page: 31


Citect for Windows, V5.xx SNMP Driver

The value in the Address field of the Variable Tag form for these tags is T0, T1, ,
T6, respectively, the Data Type is STRING and the I/O Device is any valid SNMP
I/O device.

Step 3
Create one or more graphics pages to mimic the devices you wish to monitor and
control.

Note that a tag configuration utility will soon become available to simplify the tag
configuration process and avoid the duplication of data required in the above steps.
See the Hints and Tips (Section 1.1.10) for screen shots showing an example of a
VARIABLE.CSV file and a Variable Tag form.

4.2 SNMP Time Based PDU Grouping

Should this be required, the following is the suggested logic.

Citect.ini [SNMP] section


PDUGroupCount 1 1 to 20 (Group to this figure, upto
GroupTime)
WriteGroupEnable 0 0 or 1 (1 to group Writes as well)
PDUGroupTime (ms) 0 O to 1000 (recommended value with
grouping, 20)

By default, grouping of SNMP requests will not happen. PDUGroupCount has no


meaning if the PDUGroupTime is zero. A non zero time value is the time window
that exists from the first request, to group requests into the SNMP packet, before
sending the packet.

The default settings is for one VarBind per UDP packet. Version allows VarBinds to
be stacked. This stacking logic is as follows :

If PDUGroupCount <= 1 or PDUGroupTime == 0 or neither exists


Use version 1.0 request handling
Else
If First request
Add VarBind into packet
If write request and WriteGroupEnable==0
Use version 1.0 request handling
Else
Record Time and start a PDUGroupTime Timer
Suspend thread
End If
Else if ( Total pkt size will exceed 1500)
Send out packet, cancel timer
Reset first request tag
Re-enter this logic
Else if(VarBind Count == PDUGroupCount)
Add VarBind into packet
Send out packet, cancel timer
Reset first request tag
Suspend thread
Else

Copyright 1999 Ci Technologies Page: 32


Citect for Windows, V5.xx SNMP Driver

Add VarBind into packet


Suspend Thread
End If
End If

If ThreadTimer has expired


Send out packet, reset first request tag, suspend thread
End If

4.3 SNMP Related Bugs Fixed in Windows NT Service Packs

4.3.1 Service Pack 6

Q228543 - Policy Editor Does Not Read SNMP Communities Correctly

Applies To: Microsoft Windows NT Server version 4.0 SP4

Symptoms: Simple Network Management Protocol (SNMP) communities


are enhanced in Windows NT 4.0 Service Pack 4 to include permissions for
communities. Policy Editor (Poledit.exe) cannot read these permissions or
community names correctly because of changes made in the registry to
support community security.

Cause: Because Policy Editor reads all of the necessary registry entries at
startup and then writes all of the entries when saved, whether the entry
was changed or not, the SNMP configuration information was removed from
Policy Editor to prevent the SNMP communities from being written in the
previous format and because the SNMP configuration is not a policy.

More Information: To configure SNMP communities, use the SNMP


Manager tool in Control Panel. To open SNMP Manager, in the Control Panel
Network tool, click Services, and then click SNMP Services.

Q238294 - Server Comment Set with SNMP Is Not Retained After


Restart

Applies To: Microsoft Windows NT Server version 4.0 and Microsoft


Windows NT Workstation version 4.0

Symptoms: If you set a server comment using Simple Network


Management Protocol (SNMP), the string you set lasts only until you restart
the computer or you restart the Server service.

Cause: This problem occurs because the Server service is not properly
preserving the server comment in the registry when you use SNMP to set
the comment.

More Information: You can set the server comment for the Server service
by using SNMP. The object identification (OID) is .1.3.6.1.4.1.77.1.2.1.0.
You can use the Snmputil.exe tool from the Windows NT 4.0 Resource Kit to
set or view the value.

Q241189 - SNMP Memory Leak in Windows NT4.0 Peer-to-Peer Network

Copyright 1999 Ci Technologies Page: 33


Citect for Windows, V5.xx SNMP Driver

Applies To: Microsoft Windows NT Server version 4.0 and Microsoft


Windows NT Workstation version 4.0

Symptoms: When you run the Simple Network Management Protocol


(SNMP) service on a computer connected to a Windows NT 4.0 peer-to-peer
network without a domain controller, your computer may slow down or stop
responding (hang).

Cause: This behavior occurs because the SMNP Lmmib2.dll call queries the
domain table function, for which there are no entries in a peer-to-peer
network. This behavior results in a memory leak.

4.3.2 Service Pack 5

Q196270 - SNMP Agent Leaks Memory When Queried

Applies To: Microsoft Windows NT Workstation version 4.0; Microsoft


Windows NT Server version 4.0; and Microsoft Windows NT Server,
Enterprise Edition version 4.0

Symptoms: Severe memory leakage occurs when the SNMP agent is under
stress. Also, in Perfmon, for the Network Interface Object, you may notice a
random number for the first instance, instead of 1.

Cause: This problem occurs because, while processing messages, a buffer


was used that was never freed. A regression in Service Pack 4 caused the
network interface problem.

4.3.3 Service Pack 4

Q152079 - SNMP Traps Contain Invalid Agent ID Field

Applies To: Microsoft Windows NT Workstation versions 3.51, 4.0;


Microsoft Windows NT Server versions 3.51, 4.0; and Microsoft Windows NT
Server version 4.0, Terminal Server Edition

Symptoms: The Agent ID field in SNMP traps do not contain the source
computer's IP address. The IP address, which is contained in this field, is
always of the form 0.0.x.y where x.y is the decimal representation of the
first four hexadecimal digits of the computer's host name.

Cause: If the computer has a host name which is exactly 12 characters


long and consists only of valid hexadecimal characters (1-9 and A-F), then
the SNMP trap generation code assumes that the host name is actually a
valid IPX address and places an invalid address in the Agent ID field.

More Information: To work around this problem, perform one of the


following:
? ? Make sure the host name is not 12 characters.
? ? Make sure one of the characters in the host name is not a valid
hexadecimal character.

Q160035 - Memory Leak in SNMP Subagents

Copyright 1999 Ci Technologies Page: 34


Citect for Windows, V5.xx SNMP Driver

Applies To: Microsoft Windows NT Workstation versions 3.51, 4.0;


Microsoft Windows NT Server versions 3.51, 4.0

Symptoms: Some SNMP subagents may leak memory when they receive
non-null ASN types in GET or GETNEXT requests. This can be observed by
monitoring SNMP/Private Bytes in Performance Monitor.

Cause: Most SNMP subagents don't free non-NULL variable values for GET
requests.

Q169847 - SNMP SysUpTime Counter Resets After 49.7 Days

Applies To: Microsoft Windows NT Workstation versions 3.51, 4.0;


Microsoft Windows NT Server versions 3.51, 4.0; and Microsoft Windows NT
Server version 4.0, Terminal Server Edition

Symptoms: When using SNMP to monitor sysuptime (system up time), the


counter will be reset after 49.7 days or 4294967295 milliseconds.

Cause: MIB_II.MIB (RFC 1213) specifies sysUpTime as TimeTicks. SMI.MIB


(RFC 1155) defines TimeTicks as having a max value for 4294967295. This
is the number of milliseconds that this counter can hold. This also
corresponds to about 50 days, this is why the counter resets back to 0.

Q177868 - SnmpMgrTrapListen API Returns ERROR_SERVICE_NOT_ACTIVE


Error

Applies To: Microsoft Windows NT Workstation version 4.0; Microsoft


Windows NT Server version 4.0; and Microsoft Windows NT Server version
4.0, Terminal Server Edition.

Symptoms: When you write applications that call the SnmpMgrTrapListen


API an error number 1062 (ERROR_SERVICE_NOT_ACTIVE) may be
returned if the caller is not a member of the administrators group. This error
will occur whether or not the SNMP trap service is started.

Cause: The SnmpMgrTrapListen API was opening the service control


manager database for all access (SC_MANAGER_ALL_ACCESS) to query the
status of the SNMP trap service. This level could only be granted to
members of the administrators group.

More Information: The SnmpMgrTrapListen API now opens the service


control manager database for SC_MANAGER_ENUMERATE_SERVICE to
query the status of the SNMP trap service. If the service is not started, the
API will attempt to start it. The user of the API will still need to be part of
the administrators group to start the service if it is not started when the API
runs. Or the user can use the SetServiceObjectSecurity API to change the
security for the SNMP trap service.

Q178381 - SNMP Leaks Memory If the OID Cannot Be Decoded

Copyright 1999 Ci Technologies Page: 35


Citect for Windows, V5.xx SNMP Driver

Applies To: Microsoft Windows NT Workstation version 4.0; Microsoft


Windows NT Server version 4.0; and Microsoft Windows NT Server version
4.0, Terminal Server Edition.

Symptoms: Over time, the Windows NT system responsiveness appears


sluggish, and Clients may report a gradual decrease in system performance.

By tracking the amount of Private Bytes for Snmp.exe, it can be observed


that, over time, it increases without decreasing. This is viewable using
Windows NT Performance Monitor by selecting the following counter to
monitor:
Object: Process
Instance: SNMP
Counter: Private Bytes

Cause: If SNMP cannot decode an OID from a network packet, SNMP does
not free up the memory, resulting in a memory leak in the Snmp.exe
processes. The impact of this leak will be more evident on a system running
on a network segment that receive lots of SNMP broadcast traffic.

Q182322 - SNMP Appends Garbage to Data in Response to SNMP Get

Applies To: Microsoft Windows NT Workstation version 4.0; Microsoft


Windows NT Server version 4.0; and Microsoft Windows NT Server version
4.0, Terminal Server Edition.

Symptoms: The SNMP service may return garbage appended to a Get


response. This happens when a SNMP application tries to get the description
for the network interface card (NIC).

Cause: The NIC is passing back a non-null terminated string. As a result,


garbage is appended to the description of the NIC.

Q186455 Mgmtapi.dll Opens Trap Socket in Exclusive Mode

Applies To: Microsoft Windows NT Server version 4.0; Microsoft Windows


NT Workstation version 4.0; Microsoft Windows NT Server version 4.0,
Terminal Server Edition

Symptoms: The Microsoft SNMP service opens the TCP/IP trap socket 162
in exclusive mode. This disallows other management tools from also
opening the socket. On starting, SNMP manager software may report an
error referring to socket number 162. Additionally, the SNMP management
software will not be able to receive traps from SNMP hosts.

Cause: The Mgmtapi.dll route SnmpMgrTrapThread opens socket 162 in


exclusive mode when this socket should be opened shared.

Q186473 - You Can Delete All Records on a WINS Server Using SNMP

Applies To: Microsoft Windows NT Server version 4.0 and Microsoft


Windows NT Server version 4.0, Terminal Server Edition.

Copyright 1999 Ci Technologies Page: 36


Citect for Windows, V5.xx SNMP Driver

Symptoms: It is possible to delete entries in a WINS database using SNMP.


Deleting the entries is done by sending an SNMP set packet to your WINS
server running SNMP, with a command telling it to delete a specific owner.
If security is not set up to accept packets only from certain sources, and
someone knows your community name, the server will accept any set
packets as being valid and delete the WINS owners entries.

Q189225 LMMIB2 Unable to "Walk" from .1.3.6.1.4.1.77.1.4.4

Applies To: Microsoft Windows NT Workstation version 4.0 SP4; Microsoft


Windows NT Server version 4.0 SP4; Microsoft Windows NT Server,
Enterprise Edition version 4.0; Microsoft Windows NT Server version 4.0,
Terminal Server Edition

Symptoms: An SNMP-based application (such as SNMPUTIL) receives an


Error 5 Index 1 error message from the SNMP Service when it "walks"
through .1.3.6.1.4.1.77.1.4.4 in the LANMAN II MIB.

Cause: This problem occurs because Lmmib2.dll does not return the correct
error message.

Q189245 - Lmmib2.dll Does Not Support All Objects

Applies To: Microsoft Windows NT Workstation version 4.0; Microsoft


Windows NT Server version 4.0; Microsoft Windows NT Server, Enterprise
Edition version 4.0; Microsoft Windows NT Server version 4.0, Terminal
Server Edition

Symptoms: The current implementation of Lmmib2.dll supports the


following objects documented in the Lmmib2.mib file:
Common group
Server group
Workstation group
Domain group

However, Lmmib2.dll does not support the following objects:


common.comType
server.svAuditLogSize
workstation.wkstaErrorLogSize
domain.domLogonDomain
domain.domLogonNumber
domain.domLogonTable

Q190931 - Snmptrap.exe Ignores SNMP Trap PDU Greater Than 4,096


Bytes

Applies To: Microsoft Windows NT Workstation version 4.0; Microsoft


Windows NT Server version 4.0; and Microsoft Windows NT Server version
4.0, Terminal Server Edition.

Symptoms: SNMP Trap service running on Windows NT will ignore any trap
Protocol Data Unit (PDU) that is larger then 4,096 bytes.

Cause: The buffer size for the SNMP trap is limited to 4 KB.

Copyright 1999 Ci Technologies Page: 37


Citect for Windows, V5.xx SNMP Driver

Q190932 - SNMP Service Ignores SNMP Trap PDU Greater Than 4,096
Bytes

Applies To: Microsoft Windows NT Workstation version 4.0; Microsoft


Windows NT Server version 4.0; and Microsoft Windows NT Server version
4.0, Terminal Server Edition.

Symptoms: An SNMP service running on Windows NT will ignore any trap


Protocol Data Unit (PDU) that is larger then 4,096 bytes.

Cause: The buffer size for the SNMP service is limited to 4 KB.

Q193206 - Acquiring SNMP Info For OSPF in RRAS Hangs

Applies To: Microsoft Windows NT Server version 4.0; Microsoft Windows


NT Server, Enterprise Edition version 4.0; Microsoft BackOffice Small
Business Server versions 4.0, 4.0a; and Microsoft Windows NT Server
version 4.0, Terminal Server Edition.

Symptoms: On a Windows NT Server running Routing and Remote Access


server (RRAS), an application tries to get SNMP information on OSPF and it
quits responding or fails to obtain the information.

Q194130 - SNMP Edit Box Drops a Character When Writing to the Registry

Applies To: Microsoft Windows NT Server version 4.0; Microsoft Windows


NT Workstation version 4.0; and Microsoft Windows NT Server version 4.0,
Terminal Server Edition.

Symptoms: In Properties for the Simple Network Management Protocol


(SNMP), when filling in the Contact and Location fields, you are permitted to
input up to 256 characters. However, when you apply these changes, only
255 of these characters are saved to the registry.

4.3.4 Service Pack 3

None.

4.3.5 Service Pack 2

Q154784 - Windows NT Operating System SNMP OID Incorrect

Applies To: Microsoft Windows NT Workstation versions 3.51, 4.00;


Microsoft Windows NT Server versions 3.51, 4.00.

Symptoms: SNMP traps generated on Windows NT Workstation and Server


provide an object ID (OID). Where you expect to find the OID designating
the Microsoft operating system, Inetmib1 sets as EnterpriseOID in the SNMP
trap packet the following string:
1.3.6.1.2.1.11

Copyright 1999 Ci Technologies Page: 38


Citect for Windows, V5.xx SNMP Driver

Also the OID length is set to a greater value than the actual length, and
three more unnecessary values are always attached to the OID.

Cause: Inetmib1 sets the incorrect value for EnterpriseOID and an incorrect
length for the OID.

More Information: When the update below is applied to the Windows NT


computer, the following IDs can be used to identify the type of Windows NT
computer via SNMP:
3.1.1 for workstation
3.1.2 for servers
3.1.3 domain controllers (DCs)

Q163837 SNMP Query to Windows NT Returns Same Value for NTS and
NTW

Applies To: Microsoft Windows NT Workstation versions 3.51, 4.0;


Microsoft Windows NT Server versions 3.51, 4.0.

Symptoms: When you use an SNMP utility to obtain the system type from
a computer running Windows NT, the value returned is the same for both
Windows NT Server and Windows NT Workstation. The system types appear
to be identical.

Because Windows NT workstations and servers have different capabilities, it


is necessary to differentiate between these versions of Windows NT,
especially when managing a large network. In addition, it is necessary to
differentiate between Windows NT Servers and Domain Controllers, since
they also have different roles in the domain model.

Cause: The SysObjectID field (1.3.6.1.4.1.311.1.1.3.1) returned by the


computer running Windows NT is the same if the computer is running
Windows NT Server or Windows NT Workstation.

More Information: A change was made in Windows NT 4.0 Service Pack 2


(SP2) and Windows NT 3.51 post-SP5 to the SNMP components so that the
different system types are now reported as follows:
1.3.6.1.4.1.311.1.1.3.1.1 for Windows NT Workstation
1.3.6.1.4.1.311.1.1.3.1.2 for Windows NT Servers
1.3.6.1.4.1.311.1.1.3.1.3 for Windows NT Domain Controllers

This enables the user of the SNMP utility to more precisely identify the type
of Windows NT system.

4.3.6 Service Pack 1

None.

4.4 SNMP Related Bugs in Windows NT (not fixed)

Q128746 - Removing SNMP leaves SNMP Counters in Performance Monitor

Copyright 1999 Ci Technologies Page: 39


Citect for Windows, V5.xx SNMP Driver

Applies To: Microsoft Windows NT Workstation versions 3.5, 3.51, 4.0;


Microsoft Windows NT Server versions 3.5, 3.51, 4.0

Symptoms: When you install Microsoft Simple Network Management


Protocol (SNMP) under Windows NT 3.5, 3.51 and 4.0, the following objects
are added to Performance Monitor:

ICMP
IP
Network Interface
TCP
UDP

When you remove SNMP, the objects added to Performance Monitor during
installation are not removed, and continue to be available.

Cause: This behavior is by design. The objects are not removed in order to
preserve the integrity of the performance monitor counters.

Q135597 - No Prompt to Restart When Adding SNMP Community Names

Applies To: Microsoft Windows NT operating system version 3.1; Microsoft


Windows NT Advanced Server version 3.1; Microsoft Windows NT
Workstation versions 3.5, 3.51, 4.0; Microsoft Windows NT Server versions
3.5, 3.51, 4.0

Symptoms: When you add an SNMP Community Name the Network


Settings dialog box closes without presenting the Restart dialog box. If you
do not restart the computer, the SNMP Community Name information is not
recognized.

Resolution: To work around this problem, after adding SNMP information,


shutdown and restart Windows NT or stop and restart the SNMP service in
Control Panel Services.

Q146004 - SNMP Counter Values Are Unreliable in SMP Computers

Applies To: Microsoft Windows NT Server versions 3.5, 3.51, 4.0

Symptoms: Windows NT simple network management protocol (SNMP)


counters, such as output queue length, may yield unlikely results in
symmetric multiprocessor (SMP) computers. The SNMP counters can be
viewed using Snmputil.exe from the Windows NT Resource Kit, or
Performance Monitor using the Network Interface object. For example:

snmputil getnext <server> public 2.2.1.21.1


Variable = interfaces.ifTable.ifEntry.ifOutQLen.2
Value = Gauge 3749

NOTE: In normal operation, the output queue length counter should rarely
rise above zero, when it does, it should return to zero very quickly.

Cause: This problem occurs because Windows NT TCP/IP does not use
interlocked operations to maintain its statistics counters. The SNMP
counters are maintained in the TCP/IP code.

Copyright 1999 Ci Technologies Page: 40


Citect for Windows, V5.xx SNMP Driver

In the case of output queue length, the counter is incremented every time a
packet is indicated to NdisSend(), and decremented when NDIS completes
the send successfully by returning a status of success, or returning status
pending and later calling ARPSendComplete().

Because spinlocks are not used in this code to guarantee the integrity of the
counters, SMP computers can affect the counter values during retrieval,
causing unlikely values to be reported.

The decision to not implement spinlocks to guarantee the integrity of the


SNMP counters is based on performance concerns and will not be changed.

More Information: Spinlocks were left out of the TCP/IP code for counter
operations intentionally for performance reasons. This will not be fixed.

Q149080 - Err Msg in SNMPUTIL: "error on SnmpMgrRequest 40"

Applies To: Microsoft Windows NT Workstation versions 3.5, 3.51, 4.0;


Microsoft Windows NT Server versions 3.5, 3.51, 4.0; Microsoft Windows NT
Resource Kit versions 3.5 and 3.51

Symptoms: The following error message appears when you use the
Snmputil.exe utility in the Windows NT Resource Kit:

Error on SnmpMgrRequest 40 MgmtAPI Process Detach

This error occurs when the Simple Network Management Protocol (SNMP)
service fails or does not start.

Resolution: To correct this problem, restart the service or, if necessary,


restart the computer.

Q152569 SNMP Agent Does Not Respond After Suspend Power Is


Invoked

Applies To: Microsoft Windows NT Workstation versions 3.5, 3.51, and 4.0;
Microsoft Windows NT Server versions 3.5, 3.51, and 4.0; and Microsoft
Windows 95.

Symptoms: On a computer system that has advanced power management


features or a manual power standby button (commonly found on portable
computers), invoking this power feature will disable the SNMP agent. After
the computer returns from the power saving mode, the SNMP agent does
not respond.

Cause: The SNMP agent does not reset after a power saving mode has
been released.

Resolution: The computer must be restarted to reinitialize the SNMP


agent. If you use SNMP frequently, you may also want to disable any
automatic power saving mode that is scheduled on the computer.

Copyright 1999 Ci Technologies Page: 41


Citect for Windows, V5.xx SNMP Driver

Q158770 - SNMP Service Will Not Start with Event ID: 7024

Applies To: Microsoft Windows NT operating system version 3.1; Microsoft


Windows NT Advanced Server version 3.1; Microsoft Windows NT
Workstation versions 3.5, 3.51; Microsoft Windows NT Server versions 3.5,
3.51, 4.0

Symptoms: The SNMP service fails to start and displays the following
message:

EVENT ID: 7024


Description: The SNMP Service terminated with service specific
error 3.

Cause: One possible cause of this error is that another application may be
binding to the same port as the SNMP Service. An easy way to determine if
this is the problem is to change the port number that the SNMP service
binds to. If this resolves the issue look, for any third-party applications that
may be using the same port number.
To change the port number that the SNMP service binds to, use a text editor
(such as Notepad.exe) to edit the Services file located in Windows NT
System32\Drivers\Etc directory. For example,

# Copyright (c) 1993 -1994 Microsoft Corp.


#
# This file contains port numbers for well -known services as defined by
# RFC 1060 (Assigned Numbers).
#
# Format:
#
# <service name> <port number>/<pro tocol> [aliases...] [#<comment>]
#

snmp 165/udp snmp


snmp-trap 166/udp snmp

NOTE: Remember to change the values back after you are done testing.

More Information: One method to determine if a service is using the


same port as SNMP is to execute Netstat.exe from a command prompt using
the following syntax:
netstat -an

Q163595 - SNMP Entry Point not Found

Applies To: Microsoft Windows NT Server version 4.0; Microsoft Windows


NT Workstation version 4.0

Symptoms: After you install the Simple Network Management Protocol


(SNMP) service on your Windows NT 4.0 Service Pack 2 or later computer
you may receive the following error message:

SNMP Error - Entry point not found.


The procedure entry point SnmpSvcGetEnterpriseOID could not
be located in the dynamic link library snmpapi.dll

Copyright 1999 Ci Technologies Page: 42


Citect for Windows, V5.xx SNMP Driver

Event Viewer on your Windows NT computer may also log one or more of
the following event messages:

Event ID : 7022
Source : Service Control Manager
Description: The SNMP service hung on s tarting.

-or-

Event ID : 1106
Source : SNMP
Description: The SNMP service is ignoring extension agent dll.
C:\winnt\system32\inetmib1.dll because it is missing or misconfigured.

Cause: The files you install with the SNMP service are from the original
Windows NT installation media and are older than the files supplied with the
service pack.

Resolution: To resolve this issue, you will need to reapply the latest
Windows NT service pack to update all the files.

More Information: Compaq's Insight Manager is one application that


requires the SNMP service to be installed and working correctly. Please use
the following installation order when working with a computer that is using
Insight Manager:

1. Install all required services including SNMP.


2. Before rebooting apply the latest Windows NT Service Pack.
3. Before rebooting apply the appropriate SSD from Compaq.
4. Reboot.
5. Install Insight Manager from Compaq.

Insight Manager is manufactured by Compaq Computer Corp., a vendor


independent of Microsoft; we make no warranty, implied or otherwise,
regarding this product's performance or reliability.

Q168451 - Cached IP Address Never Expires for SNMP Trap Destination

Applies To: Microsoft Windows NT Workstation versions 3.5, 3.51, 4.0;


Microsoft Windows NT Server versions 3.5, 3.51, 4.0

Symptoms: In the Simple Network Management Protocol (SNMP) Service


Configuration, the trap destination can be entered as a host name or IP
address. The host name is resolved to an IP address when the SNMP Agent
loads, and is cached until the computer with the SNMP agent is restarted, or
the SNMP service is stopped. This cached address is only used by SNMP;
other services will do a name query to find this IP address.

If the SNMP Agent is configured to send traps based on host name, and the
IP address changes on the SNMP Management Station at some point after
the SNMP Agent is started on the Windows NT computer, the trap would not
be received.

Resolution: If host names are used for trap destinations, and the IP
address of a Network Management station changes, be sure to stop and
restart the SNMP service on the Windows NT computer. The SNMP service

Copyright 1999 Ci Technologies Page: 43


Citect for Windows, V5.xx SNMP Driver

can be stopped and started by using the Services tool in Control Panel, or
by typing net stop SNMP and net start SNMP at the command line.

You can also use an IP address for the trap destination; and modify this
address if needed.

Q169363 - DOC Err: SNMP OIDs Leave off Leading Dot

Applies To: Microsoft Windows NT Workstation version 4.0; Microsoft


Windows NT Server version 4.0

Symptoms: In chapter 11 of the Windows NT 4.0 Server Resource Kit,


several example OIDs for simple network management protocol (SNMP) are
given without the leading dot.
For example table 11.3 gives an example of:

Internet MIB-II iso.org.dod.internet.mgmt.mib -2 1.3.6.1.2.1

This should be listed as:

Internet MIB-II iso.org.dod.internet.mgmt.mib -2 .1.3.6.1.2.1

When you query using an incorrect oid you will receive the following error:

Error: Invalid oid, x.x .x.x, specified.

When you use SNMP Monitor (Snmpmon.exe) from the Windows NT


Resource Kit, SNMP monitor will simply not collect data.

Resolution: To resolve this issue, use the syntax above that includes the
leading dot (.)

Q170326 - SNMPUTIL Fails with "invalid oid <oid name> specified" Error
Msg

Applies To: Microsoft Windows NT Workstation version 4.0; Microsoft


Windows NT Server version 4.0

Symptoms: When you are using the Windows NT Server 4.0 Resource Kit
utility SNMPUTIL or another simple network management protocol (SNMP)
utility, the command fails with an "invalid oid <oid name> specified" error
message.

For example, when you attempt to perform the following "get" command,
an error occurs:

C:\PROGRA~1\reskit>snmputil get testmachine publ ic system.sysDescr.0

Error: Invalid oid, system.sysDescr.0, specified.

Cause: This is caused by an invalid Mib.bin file in the path. In the case of
the above example, the SNMPUTIL utility uses the Mib.bin file in its current
folder (which is the Mib.bin file that ships with the Windows NT Server
Resource Kit), instead of the Mib.bin file in the %Systemroot%\System32
folder.

Copyright 1999 Ci Technologies Page: 44


Citect for Windows, V5.xx SNMP Driver

Resolution: Rename all Mib.bin files in the path except the one in the
%Systemroot%\system32 directory. After this is completed, the SNMP
query will work successfully, as follows:

C:\PROGRA~1\reskit>snmputil get testmachine public system.sysDescr.0

Variable = system.sysDescr.0
Value = OCTET STRING Hardware: x86 Family 6 Model 1
Stepping 7 AT/AT COMPATIBLE - Software: Windows NT
Version 4.0 (Build Number: 1381 Uniprocessor Free)

This behavior is by design.

Q173240 Multihomed Agent Sends SNMP Trap with Incorrect IP Source

Applies To: Microsoft Windows NT Workstation version 4.0; Microsoft


Windows NT Server version 4.0

Symptoms: When your multihomed Windows NT computer sends Simple


Network Management Protocol (SNMP) traps, the IP address of the first
interface is included as the originating host in the Agent ID field of the Trap
Protocol Data Unit (PDU), even though the SNMP traps are being sent to the
network on a different interface.

Resolution: Microsoft has confirmed this to be a problem in Windows NT


version 4.0. A supported fix is now available, but has not been fully
regression-tested and should be applied only to systems experiencing this
specific problem. Unless you are severely impacted by this specific problem,
Microsoft recommends that you wait for the next Service Pack that contains
this fix. Contact Microsoft Technical Support for more information.

More Information: The Trap PDU is issued by an SNMP entity on behalf of


a network management agent application. It is used to notify the
management station of a significant event. The Agent ID field is included in
the Trap PDU, and it should contain the IP address of the object generating
the trap.

Q183864 - Windows NT 4.0 Resource Kit Perfm.bat Error

Applies To: Microsoft Windows NT Server version 4.0; Microsoft Windows


NT Workstation version 4.0

Symptoms: When running the Perfm.bat batch file from the Windows NT
resource kit to install SNMP Performance Monitor Agent Extensions, you
may receive the error:

Unable to open 'C: \NTRESKIT\LMMIB2MIB'

Also, the Mib.bin file created by this batch file is incorrectly only 23 bytes
and Snmputil.exe queries may not work properly.

Cause: The batch Perfm.bat file supplied with the Windows NT resource kit
to automatically install SNMP Performance Monitor Agent Extensions has
various typos and errors that cause it to fail.

Copyright 1999 Ci Technologies Page: 45


Citect for Windows, V5.xx SNMP Driver

Resolution: The following batch file, if run from the NTReskit directory at an MS-DOS
prompt inside of Windows NT, should create the correct Mib.bin file and add the
Performance Counter Agent Extensions correctly:

@echo off
echo "Creating perfmib....."
@echo on
perf2mib perfmib.mib perfmib.ini memory 1 memory processor 2 CPU
"Network Segment" 3 net PhysicalDisk 4 disk
@echo off
echo "Compiling perfmib"
@echo on
mibcc -omib.bin -n -t -w2 SMI.MIB LMMIB2.MIB mib_ii.mib perfmib.mib

@echo off
echo "Stopping snmp service"
@echo on
net stop snmp

@echo off
echo "Saving old mib to mib.old...."
@echo on
move %systemroot% \system32\mib.bin %systemroot%\system32\mib.old
@echo off
echo "Copying perfmib files from NTResKit to s ystem32"
@echo on
copy perfmib.dll %systemroot% \system32\perfmib.dll
copy perfmib.ini %systemroot% \system32\perfmib.ini
copy mib.bin %systemroot% \system32\mib.bin

@echo off
echo "Registering new Mibs"
@echo on
regini perfmib.reg

@echo off
echo "Restarting SNMP Service"
@echo on
net start snmp

NOTE: If the SNMP Service causes an access violation when it restarts, restart the
computer.

More Information: To test the results of the batch file above, try the
following command using the Snmputil.exe utility from the Windows NT
resource kit:

SNMPUTIL get <agent> <community>


.iso.org.dod.internet.private.enterprises.microsoft.software.1.3.1.1.1
.1.0

The results should look similar to the following:

>snmputil get <agent / computernmae> <communtiy>


.iso.org.dod.internet.private.enterprises.microsoft.software.1.3.1.1.1
.1.0 Variable =
.iso.org.dod.internet.private.enterprises.microsoft.software.1.3.1.1.1
.1.0 Value = INTEGER - 757760

The above example is the "memory free" OID.

Copyright 1999 Ci Technologies Page: 46


Citect for Windows, V5.xx SNMP Driver

Q185208 - Compaq CPM v1.10 Causes 100% Processor Usage in SNMP

Applies To: Microsoft Windows NT Server version 4.0; Microsoft Windows


NT Workstation version 4.0

Symptoms: A computer running Windows NT Server or Workstation with


Compaq's Power Management Service version 1.10 installed but not
enabled, may experience 100 percent processor usage in the SNMP process.

Resolution: To work around this problem, enable the Compaq Power


Management Service v1.10 to allow the processor usage for the SNMP
service to return to normal operating levels.

To resolve this problem, upgrade the Compaq Power Management Service


v1.10 to version 1.20.

More Information: The third-party products discussed here are


manufactured by vendors independent of Microsoft; we make no warranty,
implied or otherwise, regarding these products' performance or reliability.

Q194169 - SNMP Process Object Returns the Incorrect Value

Applies To: Microsoft Windows NT Server version 4.0

Symptoms: The Object Identifier (OID) for the Process Instance Name
counter does not return the correct value when sending an SNMP Get or
Walk. Also, when walking the process OID tree when there are multiple
processes with the same name, the SNMP walk will go into an endless loop.

More Information: Performance Monitor objects can be created by using


the Perfmib utilities from the Windows NT 4.0 Resource Kit. The following
steps can be used to create a Management Information Base (MIB), which
exposes the Performance Monitor process objects:

1. From an MS-DOS prompt, run the Perfmib.reg utility from the Windows
NT 4.0 Resource Kit. This will create the appropriate registry entries for the
Perfmib.dll extension agent.

2. Build a Perfmib.mib and a Perfmib.ini file using the Per2mib.exe utility


from the Windows NT 4.0 Resource Kit. For example, from an MS-DOS
prompt, run the following command:

perf2mib perfmib.mib perfmib.ini process 300 proc

This creates a Perfmib.mib file and a Perfmib.ini file. These files are used to
expose the performance monitor process instance object.

3. Stop the SNMP service by doing either of the following:


- From an MS-DOS prompt, run the following command:

net stop SNMP

-or-

- Stop SNMP by using the Services utility in Control Panel.

Copyright 1999 Ci Technologies Page: 47


Citect for Windows, V5.xx SNMP Driver

4. Rename the mib.bin file, found in the System32 folder, to mib.old.

5. Compile a new mib.bin file, which will include the perfmib.mib file created
earlier in step 2, by performing the following steps:

a. From an MS-DOS prompt, set the default folder to t he


Windows NT 4.0 Resource Kit folder (for example, type: CD
%ntreskit%).

b. Run the following command:

mibcc -n o%ntreskit%\mib.bin -t -w2 smi.mib lmmib2.mib mib_ii.mib


perfmib.mib

6. Copy the following files from the Windows NT 4.0 Resource Kit folder
(%ntreskit%) to the System32 folder (%SystemRoot% \System32 folder):

Mib.bin
Perfmib.bin
Perfmib.ini
Perfmib.dll

7. Start the SNMP service by doing either of the following:


- From an MS-DOS prompt, run the following com mand:

net start SNMP

-or-

- Start SNMP by using the Services utility in Control Panel.

After the new MIB that contains the performance monitor process instant
objects is created, it can be tested by using the Snmputil.exe utility found in
the Microsoft Windows NT 4.0 Resource Kit. To test the MIB do the
following:

1. From an MS-DOS prompt, run the following command to change your


default to the resource kit directory:

CD %ntreskit%

2. Use the Snmputil utility to walk the process OID tree:


Run the following command:

Snmputil walk localhost public .1.3.6.1.4.1.311.1.1.3.1.1.300.1.1

Results: If there are two processes with the same name, the utility will loop
indefinitely. As long as there are not two processes with the same name,
the utility will successfully walk the tree but it will not display the process
instance name (.1.3.6.1.4.1.311.1.1.3.1.1.300.1.2); this value will be
skipped.

Q195336 - Resource Kit Perfmib.dll Cannot Read Some SNMP Counters

Applies To: Microsoft Windows NT Workstation version 4.0; Microsoft


Windows NT Server version 4.0

Copyright 1999 Ci Technologies Page: 48


Citect for Windows, V5.xx SNMP Driver

Symptoms: After installing the Perf2Mib utility from the Windows NT


Resource Kit, SNMP queries to various Performance Monitor Object Counters
return a value of zero.

Cause: The Perfmib.dll does not handle object instances correctly.

Resolution: A new version of Perfmib.dll that resolves this problem is


available on:

"ftp://ftp.microsoft.com/bussys/winnt/winnt-public/reskit/nt40/<Platform>

Please note that the Perf2Mib utility has been removed from the Resource
Kit as of Supplement2 and, consequently, future issues concerning the tool
will not be addressed.

More Information: Using Perf2mib.exe, the Performance Monitor MIB


Builder Tool, developers can create new ASN.1 syntax MIBs for their
applications, services, or devices that use Performance Monitor counters.
Administrators can then track performance of these components by using
any system-management program that supports SNMP.

This tool also creates a .mib file that can be used by an SNMP-based
management console to perform SNMP requests for the performance data in
question and, thus, to monitor performance remotely. This allows all
performance data available through the HKEY_PERFORMANCE_DATA
registry key to be exposed through SNMP.

4.5 SNMP Related Bugs in Windows 95/98 (not fixed)

The following bugs have not been fixed at the time of this release.

Q152569 SNMP Agent Does Not Respond After Suspend Power Is


Invoked

Applies To: Microsoft Windows NT Workstation versions 3.5, 3.51, and 4.0;
Microsoft Windows NT Server versions 3.5, 3.51, and 4.0; and Microsoft
Windows 95.

Symptoms: On a computer system that has advanced power management


features or a manual power standby button (commonly found on portable
computers), invoking this power feature will disable the SNMP agent. After
the computer returns from the power saving mode, the SNMP agent does
not respond.

Cause: The SNMP agent does not reset after a power saving mode has
been released.

Resolution: The computer must be restarted to reinitialize the SNMP


agent. If you use SNMP frequently, you may also want to disable any
automatic power saving mode that is scheduled on the computer.

Q159565 SNMP Agent Does Not Respond After Returning from Suspend
Mode

Copyright 1999 Ci Technologies Page: 49


Citect for Windows, V5.xx SNMP Driver

Applies To: Microsoft Windows 95 OEM Service Release versions 2, 2.1

Symptoms: When you are using Advanced Power Management features


and the computer returns from Suspend mode, SNMP Agent may not
respond when you attempt to administer the computer with SNMP network
management software.

Cause: SNMP Agent is not compatible with Advanced Power Management.

Resolution: When the computer returns from Suspend mode, quit and
restart Snmp.exe. To do so, type the following lines at a command prompt,
pressing ENTER after each line:
snmp -close
snmp

Q159567 - Windows 95 SNMP Agent Allows Only Read-Only Access

Applies To: Microsoft Windows 95

Symptoms: When you attempt to change the string value of the


sysContact, sysName, or sysLocation object on a Windows 95-based
computer using an SNMP manager (such as Hewlett-Packard OpenView),
you may receive the following error message:
SNMP error - sysContact read only (OV3122)

Cause: The Windows 95 SNMP agent allows only read-only access for the
sysContact, sysName, and sysLocation objects.

Resolution: WARNING: Using Registry Editor incorrectly can cause serious


problems that may require you to reinstall Windows 95. Microsoft cannot
guarantee that problems resulting from the incorrect use of Registry Editor
can be solved. Use Registry Editor at your own risk.

NOTE: For information about how to edit the registry, view the Changing
Keys And Values online Help topic in Registry Editor (Regedit.exe). Note
that you should make a backup copy of the registry files (System.dat and
User.dat) before you edit the registry.

Use Remote Registry Editor to set the values listed below for the
sysContact, sysName and sysLocation fields. The sysName object is not
exposed by System Policy Editor (Poledit.exe).

sysContact OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read -write
STATUS mandatory
DESCRIPTION
"The textual identification of the conta ct person for this
managed node, together with information how on to contact
this person."
::= { system 4 }

Registry key:

HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\SNMP\RFC115
6Agent\SysContact

Copyright 1999 Ci Technologies Page: 50


Citect for Windows, V5.xx SNMP Driver

sysName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read -write
STATUS mandatory
DESCRIPTION
"An administratively assigned name for this managed node.
By convention, this is the node's fully qualifi ed domain
name."
::= { system 5 }

Registry key:

HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\ComputerName
\ComputerName

sysLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read -write
STATUS mandatory
DESCRIPTION
"The physical location of this node (e.g., 'telephone
closet, 3rd floor')."
::= { system 6 }

Registry key:

HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\SNMP\RFC115
6Agent\SysLocation

More Information: The values for the SNMP objects sysContact, sysName,
and sysLocation are documented in the Internet MIB-II definition in RFC
1158.

Q188202 - Err Msg: A Required .DLL File, SNMPAPI.DLL, Was Not Found

Applies To: Microsoft Windows 98

Symptoms: When you install the Microsoft Simple Network Management


Protocol (SNMP) agent on a computer using Microsoft Client for NetWare
Networks, the SNMP agent may not start and you may receive the following
error message:
A required .DLL file, SNMPAPI.DLL, was not found.

Cause: This behavior can occur because the Snmpapi.dll file is not installed
with the Microsoft Client for NetWare Networks.

Resolution: To resolve this issue, install the Microsoft SNMP Agent. To do


so, use the following steps:

1. Click Start, point to Settings, click Control Panel, and then double-click
Network.

2. Click Add, click Service, click Have Disk, type the path to the
Tools\Reskit\Netadmin\SNMP folder on your Windows 98 CD-ROM, and
then click OK. For example, if your CD-ROM drive letter is D, the path
would be:
d:\Tools\Reskit\Netadmin\SNMP

Copyright 1999 Ci Technologies Page: 51


Citect for Windows, V5.xx SNMP Driver

NOTE: If you are prompted to specify the location of additional files,


specify the path to the Windows 98 source files on a network share, or on
the Windows 98 compact disc.

Copyright 1999 Ci Technologies Page: 52

Potrebbero piacerti anche