P1

Height of Pier 10.5 m 920.00


Length of Pier (x section) 5.85 m
Breadth of pier 1.4 m
Length of Pipe 16 m
Unit weight of water 9.81 kN/m3 10.5 m
Unit weight of Concrete 24 kN/m3 P2
Density of Steel 78.5 kN/m3 474.6924
Inner diameter of pipe 1.75 m

Outer diameter of pipe 1.81 m


Weight of water 23.60 kN/m V
Weight of Pipe 13.17 kN/m 1394.69
Weight of water and pipe per
unit length 36.77 kN/m M1 9660.00
Total weight supported by
pier 4000.00 kN M2 2492.1351
Weight of Pier 2063.88 kN
Horizental Seismic Coef 0.23
Lateral load acting on pier

P1 920.00 kN
P2 474.69 kN
Shear at base (V) 1394.69 kN
Moment (M) 12152.14 kNm
Load factor 1.2
Factored Moment
Overturning (Mu) 14582.56212 kNm
Base width of footing 6.8 m
Resisting Moment 7017.192
AREA OF STEEL d 1700
Mu= 7565.37012 kNm fck
Mu=0.87*fy*Ast*d*(1-((Ast*fy)/fck*b*d)) fy

Solving the equation


a b c soln. (d1) soln. (d2)
b b 2 4ac
8.7 739500 7.6E+009 -11895 -73105 x
2a

Ast Req'd 11894.980353 mm2


Bar dia Area of Steel
25 mm 491 sqmm
No of bars 24.232
Provision For Rock Dowels
kN
Base width of footing 6m
Clear Cover 40 mm
d 5.92 m
Fy 500 Mpa
M1 9660.00 kNm
kN M2 2492.1351 kNm
Total 12152.14 kNm
Total unbalanced force,
say ( C )
Cxd= 12152.14
kN C 2052.72552365 kN

kNm No of Dowels assumed 5 Nos

kNm Bar dia Area of Steel


32 mm 804 sqmm

1600 Force per each dowel 410.55 kN


Actual Force taken by
dowel 241.27 kN
Factor of Safety 0.6

25
500

b b 2 4ac

2a
Footing
6m

d 5.92