D-6006
Re-contacting Drum
Jan 2017/TKH 2
Section 11 : Process Flow Diagram Example (1/2)
Bottom Circuit of
Distillation Tower
Jan 2017/TKH
3
A. Design Temperature(DT)
A. Design Temperature(DT)
1. Every piece of process equipment or piping is designated a design temperature.
2. For conditions up to + 400 C ,
DT = maximum operating temperature + 30 C
3. Value normally rounded up to next higher number in 5 C increment.
4. Tighter safety margins may be used above this given temperature range.
5. DT is used to determine the allowable stress value (S) for use in equation to
calculate minimum thickness for a vessel/piping:
Pi Di
t= >> eqn. 14.13 Towler 's Chem. Eng . Design
2 SE 1.2 Pi
6. Often there is need to consider critical exposure temperature (CET) for equipment
and piping.
7. CET is temperature that equipment will be subjected to at internal pressure greater
than 25 % design pressure or the lowest one-day mean temperature , whichever is less.
8. Important for cryogenic processes and cold climates ; to ensure equipment material has
sufficient toughness to prevent brittle fracture.
Jan 2017 / TKH 4
B. Design Pressure (DP)
B. Design Pressure(DP)
1. DP value is used in equation for calculating minimum thickness of piping and equipment (=Pi).
2. For most process equipment:
DP = 110% maximum operating pressure , or
= max. operating pressure + 170 kPa (1.7bar), whichever is greater.
3. Value normally rounded up to higher number in 50 kPa increment.
4. Safety Valve(SV) protecting equipment is normally set to relieve at DP value.
5. Delta(~ 10%) takes care of normal fluctuations in operating pressure as well as preventing SV leakage.
6. For equipment operating in vacuum( partial of full):
DP = 110 kPag (16 psig) & Full Vacuum ( 0 kPaa)
This allows vessel to be designed in accordance with ASME code.
7. For centrifugal pump (casing) and also downstream equipment:
DP = max. suction pressure + 120% ( rated pump differential pressure)
120% allowance caters for pressure rise in a centrifugal pump at shutoff condition.
Jan 2017 / TKH For flanges larger than NPS 24 (DN 600), refer to ASME
7
B16.47 Series B
C. ASME 16.5 2013 Ratings for Stainless Steel Flanges thru NPS 24 ( DN 600)