Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
341100890
Theory:
Classification of Notches
1. Rectangular Notch
2. Triangular Notch
3. Trapezoidal Notch
4. Stepped Notch
Theoretical discharge over Rectangular Notch
L dh 2 gh
Therfore;
H
Qth = L 2 gh dh
0
2 3 /2
L 2 g H
3
Actual discharge over Rectangular Notch
{ }
2
wb h cwh
+
2d 2
Q act = height hthe collecting tank .
Where
Qact
C d=
Qth
Experiments procedures
Result Table
Height of
Theoretical Actual
water rise
Discharge Discharg
S.No. h (cm) Time (sec) over the Cd
(Qth) e (Qact)
notch (H)
(m3/s) (m3/s)
(mm)
1 10 66 20 0.000249 0.000186 0.75
2 10 60 25 0.000347 0.0002045 0.59
3 10 44 30 0.00046 0.000278 0.60
4 10 38 35 0.000576 0.000323 0.56
Average value of coefficient of discharge (Cd) = 0.63
0
0
0
0
Q 0 Qth
0 Qact
0
18 20 22 24 26 28 30 32 34 36
H (m)
0
Q act 0
0
0 0 0 0 0 0.01 0.01 0.01
Qht