Sei sulla pagina 1di 7

FORM 72

RECOMMENDED SCOPE OF ACCREDITATION


(For Testing Laboratories)
Laboratory: Sparkle Labs India Private Limited. (Gurgaon) Date(s) of Visit: 18 19 June 2016
Discipline: Mechanical
Sl
Product(s) / Specific tests performed * Test Method / Standard Range of Testing/ Uncertainty of
Material of test against which tests are Limits of detection Measurement
performed ()

1 High Strength Nominal mass IS: 1786-2008 0.075-100 kg / mt


0.67 kg/m @
0.995 kg/m
Deformed
Steel Bars
4.09 N/mm2@
IS 1786 Ultimate Tensile Stress IS.1608-2005(Reaffirmed 2010) 160 N/mm 900 N/mm
707.8N/mm2
IS.1608-2005 3.72
Yield Stress (Reaffirmed 2010) 100 N/mm 800 N/mm N/mm2@459.2N/
mm2

Elongation IS.1608-2005 (Reaffirmed 2010) 5% - 40% 2 %@ 19.02%

* When referring to publications like NCCLS, IP, BP, USP, ASTM, AOAC etc. kindly mention the clause / chapter / page number, as appropriate.
+ The value at which uncertainty of measurement estimated shall also be specified.
Laboratories performing site testing shall clearly identify the Specific tests on products(s) / material performed at permanent laboratory and / or at site. Refer NABL 130 for
details.

Signature, Date & Name of Lab Signature, Date & Name of Signature, Date & Name of Lead
Representative Assessor(s) Assessor
National Accreditation Board for Testing and Calibration Laboratories

Doc. No: NABL 215 Assessment Forms and Checklist (Based on ISO/IEC 17025: 2005)
Issue No: 05 Issue Date: 02.07.2012 Amend No: 00 Amend Date: - Page No: 1/ 63
FORM 72

RECOMMENDED SCOPE OF ACCREDITATION


(For Testing Laboratories)
Laboratory: Sparkle Labs India Private Limited. (Gurgaon) Date(s) of Visit: 18 19 June 2016
Discipline: Mechanical
Sl
Product(s) / Specific tests performed * Test Method / Standard Range of Testing/ Uncertainty of
Material of test against which tests are Limits of detection Measurement
performed ()

2. Aggregate
Sieve Analysis IS : 2386- Part 1-1963,
(Coarse) 150 micron 80mm 1 mm @ 20 mm
(Reaffirmed 2011)

Specific gravity IS : 2386- Part 3-1963,


(Reaffirmed 2011)
24 0.01@ 2.68

Water Absorption IS : 2386- Part 3-1963,


0.1% - 5% 0.20 %@2.45%
(Reaffirmed 2011)

IS : 2386- Part 3-1963, 0.01kg/ltr@


Bulk Density (Loose & Rodded) 0.8 to 2.2 kg/lit
(Reaffirmed 2011) 1.92kg/ltr

Flakiness Index IS : 2386- Part 1-1963,


2% - 50% 2.87 % @20.6%
(Reaffirmed 2011)

Elongation Index IS : 2386- Part 1-1963, 3.61 %


2% - 50%
(Reaffirmed 2011) @ 21.04%

IS : 2386- Part 4-1963,


Agg. Impact value 5% - 50% 2.45 % @25%
(Reaffirmed 2011)

Aggregate Crushing value IS : 2386- Part 4-1963,


2% - 60% 1.81 % @20%
(Reaffirmed 2011)
10% fines value IS : 2386- Part 4-1963, 50 -400kn 9.3kn @186.25kn
(Reaffirmed 2011)

* When referring to publications like NCCLS, IP, BP, USP, ASTM, AOAC etc. kindly mention the clause / chapter / page number, as appropriate.
+ The value at which uncertainty of measurement estimated shall also be specified.
Laboratories performing site testing shall clearly identify the Specific tests on products(s) / material performed at permanent laboratory and / or at site. Refer NABL 130 for
details.

Signature, Date & Name of Lab Signature, Date & Name of Signature, Date & Name of Lead
Representative Assessor(s) Assessor
National Accreditation Board for Testing and Calibration Laboratories

Doc. No: NABL 215 Assessment Forms and Checklist (Based on ISO/IEC 17025: 2005)
Issue No: 05 Issue Date: 02.07.2012 Amend No: 00 Amend Date: - Page No: 1/ 63
FORM 72

RECOMMENDED SCOPE OF ACCREDITATION


(For Testing Laboratories)
Laboratory: Sparkle Labs India Private Limited. (Gurgaon) Date(s) of Visit: 18 19 June 2016
Discipline: Mechanical
Sl
Product(s) / Specific tests performed * Test Method / Standard Range of Testing/ Uncertainty of
Material of test against which tests are Limits of detection Measurement
performed ()

IS : 2386- Part 2-1963,


Soundness 0% - 20% 0.86 %@3.27%
(Reaffirmed 2011)

Stripping Value IS: 6241-1971, RA 2003 Up to 100%


Qualitative

3 Aggregate
Sieve Analysis IS : 2386- Part 1-1963,
(Fine) 75 micron 12.5mm 0.4mm @ 4.75mm
(Reaffirmed 2011)

Specific gravity IS : 2386- Part 3-1963,


(Reaffirmed 2011)
24 0.01@ 2.68

Water Absorption IS : 2386- Part 3-1963,


0.1% - 5% 0.20 %@2.45%
(Reaffirmed 2011)

IS : 2386- Part 3-1963, 0.01kg/ltr@


Bulk Density (Loose & Rodded) 0.8 to 2.2 kg/lit
(Reaffirmed 2011) 1.92kg/ltr

Bulking IS : 2386- Part 3-1963,


0% - 20% 1.72 % @13.19%
(Fine Aggregate) (Reaffirmed 2011)

IS : 2386- Part 2-1963,


Soundness 0% - 20% 0.86 %@3.27%
(Reaffirmed 2011)

IS : 2386- Part 2-1963,


Deleterious Materials 0.2% -10% 0.17 %@2.38%
(Reaffirmed 2011)

4 Fresh concrete Workability (slump) 1S:516-1959 0mm - 250mm 5 mm @132mm


with Admixture (Reaffirmed 2013)
* When referring to publications like NCCLS, IP, BP, USP, ASTM, AOAC etc. kindly mention the clause / chapter / page number, as appropriate.
+ The value at which uncertainty of measurement estimated shall also be specified.
Laboratories performing site testing shall clearly identify the Specific tests on products(s) / material performed at permanent laboratory and / or at site. Refer NABL 130 for
details.

Signature, Date & Name of Lab Signature, Date & Name of Signature, Date & Name of Lead
Representative Assessor(s) Assessor
National Accreditation Board for Testing and Calibration Laboratories

Doc. No: NABL 215 Assessment Forms and Checklist (Based on ISO/IEC 17025: 2005)
Issue No: 05 Issue Date: 02.07.2012 Amend No: 00 Amend Date: - Page No: 1/ 63
FORM 72

RECOMMENDED SCOPE OF ACCREDITATION


(For Testing Laboratories)
Laboratory: Sparkle Labs India Private Limited. (Gurgaon) Date(s) of Visit: 18 19 June 2016
Discipline: Mechanical
Sl
Product(s) / Specific tests performed * Test Method / Standard Range of Testing/ Uncertainty of
Material of test against which tests are Limits of detection Measurement
performed ()

1S:516-1959
Setting time 3 hr -12 hr 0.53 hr@ 6hrs
(Reaffirmed 2013)
1S:516-1959
Bleeding 0% - 10% 0.52 %@5%
(Reaffirmed 2013)
1S:516-1959
Water content 5% - 30% 1.42@76.4%
(Reaffirmed 2013)
1S:516-1959 0.42 N/mm2 @
Compressive strength 5 N/mm260 N/mm2
(Reaffirmed 2013) 35.46N/mm2
5 Bitumen IS : 1448-Part-69 : 1969
Flash Point (Reaffirmed 2003) 30 oC 400 oC 1.1oC @ 164.8oC

IS : 1448-Part-69 : 1969
Fire Point (Reaffirmed 2003) 30 oC 400 oC 1.4oC @ 260.8oC

IS : 1205-1978 1.6 oC
Softening Point 40 oC - 85 oC
(Reaffirmed 2004) @ 47.4 oC
6 Asphalt Mix Binder content ASTM- D 2172 2 - 12% 0.3 % at 5.4%
7 Soil Liquid Limit IS 2720 (Part 5) 1985
10 to 50 % 1.0% at 23.14 %
Reaffirmed 2011
Plastic Limit IS 2720 (Part 5) 1985
10 to 40 % 0.2% at 19.92 %
Reaffirmed 2011
Specific Gravity IS 2720 (Part 3) 1980 1 to 3.0 0.01 at 3
second revision
Reaffirmed 2011

* When referring to publications like NCCLS, IP, BP, USP, ASTM, AOAC etc. kindly mention the clause / chapter / page number, as appropriate.
+ The value at which uncertainty of measurement estimated shall also be specified.
Laboratories performing site testing shall clearly identify the Specific tests on products(s) / material performed at permanent laboratory and / or at site. Refer NABL 130 for
details.

Signature, Date & Name of Lab Signature, Date & Name of Signature, Date & Name of Lead
Representative Assessor(s) Assessor
National Accreditation Board for Testing and Calibration Laboratories

Doc. No: NABL 215 Assessment Forms and Checklist (Based on ISO/IEC 17025: 2005)
Issue No: 05 Issue Date: 02.07.2012 Amend No: 00 Amend Date: - Page No: 1/ 63
FORM 72

RECOMMENDED SCOPE OF ACCREDITATION


(For Testing Laboratories)
Laboratory: Sparkle Labs India Private Limited. (Gurgaon) Date(s) of Visit: 18 19 June 2016
Discipline: Mechanical
Sl
Product(s) / Specific tests performed * Test Method / Standard Range of Testing/ Uncertainty of
Material of test against which tests are Limits of detection Measurement
performed ()

IS 2720 (Part 4) 1985 0.05 mm at


Grain Size 0 to 100 %
Reaffirmed 2011 4.75mm
IS 2720 (Part 40) 1977
Free Swell Index 0 to 20 % 1.5 % at 21.72 %
Reaffirmed 2011
Proctor test
IS 2720 (Part 7) 1983 M. D. D.- 0.01 g/cc at 1.77
Light Compaction Test
Reaffirmed 2010 1.5 to 2.5g/cc g/cc
IS 2720 (Part 8) 1983 O. M.C.- 4 to 20 % 0.01 g/cc at 1.94
M. D. D.- 1.6 to 2.8 g/cc
Heavy Compaction Test second revision g/cc
O. M.C.- 4 to 20 %
Reaffirmed 2010 0.1% at 10.60 %
IS 2720 (Part 2) 1983
Moisture Content 0 to 50% 0.1% at 10.60 %
Reaffirmed 2011
CBR Value IS:2720 (Part 16) 2.3% at 25.66 %
2.0 to 40 %
Reaffirmed 2011

8 Cement IS : 4031-Part 4-1998 (Reaffirmed 1.5 %


Consistency 2009) 15%-45%
@ 34.5%

IS : 4031-Part 5-1998 4.46 minutes


Initial setting time 30 minutes -300 minutes
(Reaffirmed 2009) @155minutes

IS : 4031-Part 5-1998 5.61 minutes


Final setting time 150 minutes - 700 minutes
(Reaffirmed 2009) @253minutes
Fineness IS : 4031-Part 2-1999 (Reaffirmed 150 m2/kg 450 m2/kg 3.96 m2/kg
(Blaines method) 2008) @355 m2/kg

* When referring to publications like NCCLS, IP, BP, USP, ASTM, AOAC etc. kindly mention the clause / chapter / page number, as appropriate.
+ The value at which uncertainty of measurement estimated shall also be specified.
Laboratories performing site testing shall clearly identify the Specific tests on products(s) / material performed at permanent laboratory and / or at site. Refer NABL 130 for
details.

Signature, Date & Name of Lab Signature, Date & Name of Signature, Date & Name of Lead
Representative Assessor(s) Assessor
National Accreditation Board for Testing and Calibration Laboratories

Doc. No: NABL 215 Assessment Forms and Checklist (Based on ISO/IEC 17025: 2005)
Issue No: 05 Issue Date: 02.07.2012 Amend No: 00 Amend Date: - Page No: 1/ 63
FORM 72

RECOMMENDED SCOPE OF ACCREDITATION


(For Testing Laboratories)
Laboratory: Sparkle Labs India Private Limited. (Gurgaon) Date(s) of Visit: 18 19 June 2016
Discipline: Mechanical
Sl
Product(s) / Specific tests performed * Test Method / Standard Range of Testing/ Uncertainty of
Material of test against which tests are Limits of detection Measurement
performed ()

Soundness IS : 4031-Part 3-1988


0.50 mm10 mm 0.29 mm @0.52mm
a) Le-Chateliers method (Reaffirmed 2009)
IS : 4031-Part 3-1988
b) Autoclave method 0.02 - 0.8% 0. 016 % @0.07%
(Reaffirmed 2009)
IS : 4031-Part 6-1988 1.78 N/mm2
Compressive strength 10 N/mm2 -70N/mm2
(Reaffirmed 2009) 45.10N/mm2
9 Fly Ash
Fineness 100 Sq.m/kg 7.60sq.m/kg@352q
IS : 4031 pt 2 1999
(Blaines method) - 450 Sq.m/kg .m/kg

IS : 1727-1967
Specific gravity 13 0.14@2.14
(Reaffirmed 2008)

10 Bricks
IS : 3495 -1992
Water absorption 1% - 20% 1.25 %@12.16%
(Reaffirmed 2007)

IS : 3495 -1992 1.52 N/mm2


Compressive strength 1 N/mm2 - 30 N/mm2
(Reaffirmed 2007) @12.6 N/mm2

IS : 3495 -1992 Qualitative, Visual


Efflorescence Not applicable
(Reaffirmed 2007) Observation

L- 4500- 4700 mm 1.5mm @ 4652.4


IS : 3495 -1992 2.83mm@2236mm,
Dimensions W- 2100-2300 mm
(Reaffirmed 2007) 1.84mm@1411.8m
H- 1300-1500 mm
m

* When referring to publications like NCCLS, IP, BP, USP, ASTM, AOAC etc. kindly mention the clause / chapter / page number, as appropriate.
+ The value at which uncertainty of measurement estimated shall also be specified.
Laboratories performing site testing shall clearly identify the Specific tests on products(s) / material performed at permanent laboratory and / or at site. Refer NABL 130 for
details.

Signature, Date & Name of Lab Signature, Date & Name of Signature, Date & Name of Lead
Representative Assessor(s) Assessor
National Accreditation Board for Testing and Calibration Laboratories

Doc. No: NABL 215 Assessment Forms and Checklist (Based on ISO/IEC 17025: 2005)
Issue No: 05 Issue Date: 02.07.2012 Amend No: 00 Amend Date: - Page No: 1/ 63
FORM 72

RECOMMENDED SCOPE OF ACCREDITATION


(For Testing Laboratories)
Laboratory: Sparkle Labs India Private Limited. (Gurgaon) Date(s) of Visit: 18 19 June 2016
Discipline: Mechanical
Sl
Product(s) / Specific tests performed * Test Method / Standard Range of Testing/ Uncertainty of
Material of test against which tests are Limits of detection Measurement
performed ()

11 Concrete
IS : 516-1959 5 N/mm2 - 2.08 N/mm2
Cube Compressive Strength
(Reaffirmed 2008) 80 N/mm2 @23.25N/mm2

Workability by Slump Test IS: 1199-1959, RA 2004 Upto 250 mm 2.03 mm @ 100
mm

12 PRECAST Compressive Strength IS: 15658-2006 5.0 N/mm to 80


1.78 N/mm2 @
CONCRETE N/mm
45.10N/mm2
PAVER
BLOCK Visual Inspection IS: 15658-2006 NA
NA

Dimensions IS: 15658-2006 1 mm to 500 mm


1mm @ 204mm

Water Absorption IS: 15658-2006 1% to 20%


2.83% @ 5.16 %

* When referring to publications like NCCLS, IP, BP, USP, ASTM, AOAC etc. kindly mention the clause / chapter / page number, as appropriate.
+ The value at which uncertainty of measurement estimated shall also be specified.
Laboratories performing site testing shall clearly identify the Specific tests on products(s) / material performed at permanent laboratory and / or at site. Refer NABL 130 for
details.

Signature, Date & Name of Lab Signature, Date & Name of Signature, Date & Name of Lead
Representative Assessor(s) Assessor
National Accreditation Board for Testing and Calibration Laboratories

Doc. No: NABL 215 Assessment Forms and Checklist (Based on ISO/IEC 17025: 2005)
Issue No: 05 Issue Date: 02.07.2012 Amend No: 00 Amend Date: - Page No: 1/ 63