FEATURES
CAPACITIVE LIMIT DETECTION FOR FOOD AND BEVERAGE WITH HYGIENIC PROCESS
CONNECTION
PARTICULARLY SUITABLE FOR LOW LEVEL INDICATION AT TANK BOTTOMS
INDEPENDENT OF CONDUCTIVITY OF MEDIA
SPECIALLY FOR LIMIT DETECTION OF PASTY MEDIA AND HEAVY PRODUCT DEPOSITS
EXTENDED MEASURING RANGE FOR CRITICAL MEDIA (E.G. OIL, FAT, ...)
ROUGH CONSTRUCTION IN PROTECTION CLASS IP 69K
DESCRIPTION Examples
Medium DK value
The LEVELTEC L capacitive level switch is used specifically for low level (empty)
detection at tank bottoms for pasty and adhesive media. Due to its construction of Water 81
an inactive extension of the measuring pipe, the LEVELTEC L is insensitive to product Ketchup, honey 24
deposits, thereby guaranteeing reliable detection. Due to the temperature resistance of the
Cream (skin) 19
device, sterilisation and CIP cleaning can be performed.
The output signal can be connected directly to a PLC or PLS for further processing. The Acetic acid 6.2
hygienic adaptation to the process is ensured by corresponding welded-in parts and Butter 6
flush-mounting. The adaptation to the DK values of the respective media can be infinitely Chocolate 3
adjusted in the device.
Vegetable oil 2
INSTALLATION INSTRUCTIONS
Due to their high flexibility and installation lengths, the level probes of type LEVELTEC L
are suitable both for applications in metallic tanks for empty or full level detection, as well
as for use in metallic pipes, as pump protection.
Hengesbach GmbH & Co. KG Schimmelbuschstr. 17 D-40699 Erkrath Tel. +49 (0) 21 04/30 32-0 Fax +49 (0) 21 04/30 32-0 www.hengesbach.com
Capacitive level switch
- Type LEVELTEC L - minimum detection
TECHNICAL DATA
General details
Device type/measuring principle LEVELTEC L / capacitive level detection
Output
Output signal 3-wire: Active output, max. 50mA, short-circuit-proof
Switching function adjustable by polarity of supply
- high active (sensor wetted high)
- low active (sensor wetted low)
Status display LED
Electronics
Version S Standard version, set to a dielectric constant (Dk value), factory setting =20
Parametrised by pressing on TeachIn button
Conditions of use
Installation position 10h, 14h, horizontal
Setting Press and hold TeachIn button for approx. 3 seconds; probe must be covered when settings are created
Medium temperature Design B: -20...+100C (short duration 140C for max. 30min)
Design HT: -20...+140C (high-temperature version)
Ambient temperature -20...+80C
Storage temperature -20...+80C
Max. operating pressure 6bar (with TEM1FTP16 welded socket)
Protection class acc. to EN60529 IP 67 and IP 69K (by use of M16x1,5 Hengesbach-system)
Electromagnetic compatibility Sensitivity against interference: acc. to DIN IEC 61000-6-2
Interference radiation: acc. to DIN IEC 61000-6-4
Construction
Electrical connection - Standard: M16x1.5 cable gland, nickel-plated brass (stainless steel available on request)
- Optional: M12x1 connector, nickel-plated brass (stainless steel available on request)
Process connection - G1/2" with elastomer-free sealing cone (TP16), tightening torque max. 10Nm
Materials - Housing / lid: Stst. 1.4301 (304)
- Housing seal: FPM (Viton)
- Process connection/extension tube: Stst. 1.4305 (305)
- Coupling part and inactive extension: PEEK (FDA-compliant)
- Probe tip: PFA P16501 approx. 200m thick
Device design / installation length - A installation length 46mm
Auxiliary energy resources
Supply voltage 12...35V DC, max. 25mA without switching load
N-LEVELTEC-L-EN-16-1/2
Hengesbach GmbH & Co. KG Schimmelbuschstr. 17 D-40699 Erkrath Tel. +49 (0) 21 04/30 32-0 Fax +49 (0) 21 04/30 32-0 www.hengesbach.com
Capacitive level switch
- Type LEVELTEC L - minimum detection
DIMENSIONAL DRAWINGS (dimensions in mm)
M16x1,5
(M12-Stecker) zem / TP16 zem / TP
M16x1,5 mit Leckage
(M12-circular connector) with bore
leakage
zfl / VA - TP16
VARIVENT - Flansch d=68mm
VARIVENT - flange d=68mm
Prozessanschlussadapter: (weitere Ausfhrungen auf Anfrage)
adapters for process-connection: (other constructions on request)
TMN...FTP16 NAM1FTP16
Kegelstutzen DIN 11851 Adaptermuffe L
conical nozzle DIN 11851 adapter socket L
DN25, DN40, DN50
N-LEVELTEC-L-EN-16-1/3
Hengesbach GmbH & Co. KG Schimmelbuschstr. 17 D-40699 Erkrath Tel. +49 (0) 21 04/30 32-0 Fax +49 (0) 21 04/30 32-0 www.hengesbach.com
Capacitive level switch
- Type LEVELTEC L - minimum detection
ORDERING INFORMATION for LEVELTEC L
Electronics
S Standard version with adjustment via TeachIn button
Design
B Standard version
HT High-temperature version
Electrical connection
C M16x1.5 cable gland
M M12x1 round connector
Installation length
A 46mm
LEVELTEC L S
Please observe the permissible nominal pressure of the process connection selected.
All specifications and certifications specified are only guaranteed when Hengesbach original components are used.
Dont use these devices in hazardous or explosive or security-relevant areas It is not permitted for these applications.
Our devices are subject to constant development; subject to technical modification.
N-LEVELTEC-L-EN-16-1/4