Sei sulla pagina 1di 4

CALCULATE CAPACITY OF Room AIR CONDITIONER

Room Detail Unit Sq.Foot


Length of Room(Foot) 12 Width of Room(Foot) 11

Windows in North Side Window in South Side


Qty Lengt(Foot) Width(Foot) Qty Lengt(Foot) Width(Foot)
1 3 3 0.84 1 10 4 4
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0

Total 0.837 Total 3.72

Total Room Area in Sq.Foot 132


Is there any Blinds on The windows Yes
Nos of Persons Who may utilize the Room
CONDITIONER

Electrical Appliances in The Room


Electrical Equipments Electrical Lighting
Qty Watt Total Qty Watt Total
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Jignesh.Parmar www.electricalnotes.wordpress.com. jiguparmar@yahoo.com

CALCULATION
Room BTU 4125
South window BTU 3229
North Window BTU 137
Windows BTU 3366
Occupant BTU 0
Equipment BTU 0
Lighting BTU 0

Total Heat Load BTU 10857


Total Cooling Required (BTU) 10857

Required A.C (Tone) 0.90


OR
Required A.C (KW) 3.18

Yes
No

Sq.Foot
Sq.Meter
(Foot)