Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Slide 1
Content
Principles
Features
Integrated model
Advanced Technology
Flowcytometry
Friendly User
SNCS
Aids in Diagnosis Patient
UTI
Hematuria
Conductivity
Early stage nephropathy
Summary
Urobilinogen
Keton body
Nitrite salt
Micro-Alb
Creatinin
Turbidity
Glucose
Specific
Gravity*
Protein
Bililbin
Blood
Color
WBC
pH
Name
Meditape10U N/A I I I
Meditape10K N/A I I I
Slide 4
UX-2000 Principle - CHM
Strips
Detector LED
LED
(Photo Diode)
Dual-
Wavelength
Reference
Method
Test Strip
Slide 5
UX-2000 Principle - CHM
Specific
Light Flow Cell Sample Prism Slit
Gravity (LED)
Transmission
Refractometry S.G.-Unit
Method
CCD-sensor
Slide 6
UX-2000 Principle - CHM
Cylindrical Cell
Photodiode
Color 470/525/635nm
Multi-LED
(Transmitted
light)
Hue
Reflectivity
Measurement
Method Photodiode
(Scattered light)
23 combination colors
NORMAL
Slide 7
UX-2000 Principle - CHM
Cylindrical Cell
Photodiode
470/525/635nm
(Transmitted
Turbidity Multi-LED light)
Light Scattering
Measurement
Method
Photodiode
(Scattered light)
Slide 8
UX-2000 Principle - FCM
Fluorescence flow cytometry method using 635nm red
semiconductor laser
Slide 10
Integration
(Operator)
Aids in
Advanced
diagnosis
technology
patient
(Managerial)
(Clinicians)
Consolidated workflow
Fast TAT with troughput approx. 100 samples/h (chemistry+sediment)
Less time spent in operating different instruments
Compact design
Saves space in labs with limited work area
Scattergrams &
CHM results Histograms
Crosscheck flag
Crosscheck Function
Check if 2 parameters
relating each other are
consistent or not
User-definable
Up to 10 conditions
Examples:
BLD x RBC
LEU x WBC
NIT x BACT
PRO x CAST
Slide 14
Appendix 2
Reflex Test
Automatically order a FCM
test according to CHM result
User-definable
Up to 10 conditions
SG, Turbidity and Color can
be used
Application choices:
sediment analysis or bacteria
only analysis
Examples:
GLU > 1.70mg/dL and
PRO > 2.10mg/dL
Slide 15
Integration (and automation)
Standardization
Eliminates subjectivity (e.g. in urine strip color determinations,
urine particle recognition under microscope)
Eliminates error-prone analysis and minimizing causes of
variance (e.g. Aspirated sample volume, centrifugation, etc)
SNCS SV at Sysmex
Questra SV in Japan
Scientific
Remote Preventive Remote
Online QC tools e.g.
service maintenance version up
Case study
Online QC
3 lots of QC are chosen
Send QC results to server
Real time
Remote service
Sysmex & customers share same IPU screen
Error log automatically send to server when instrument is shut
down
Using spot urine (instead of 24h urin for albumine and creatinine
parameters), within minutes.
P/C results:
Diagnose patients with renal diseases
Monitor patients with renal diseases
Slide 29
Summary Managerial view point
Feature Advantages Benefits
Advanced Technology FCM proven technology Decrease labor cost by
User-friendly software spending less time on
Dedicated sediment and screening all samples but
bacteria channels for high focus on pathological samples
sensitive measurement only
SNCS available Easy to operate, spend less
time on training and
troubleshooting
On-line QC for real time QC
result comparison with peer
group
Remote service to shorten
troubleshooting time, thus
decrease down time of
instrument
Slide 30
Summary Clinical view point
Slide 31