Sei sulla pagina 1di 86

FLAT SLAB

Step 1: Span / d = 35 (Flat Slab Design)

Span, L 6000 mm
d 171.43 mm

Assume exposure classification A2 (Perth, temperate zone)


f'c 32.00 Mpa
cover 60.00 mm
bar diameter 16.00 mm

Ds > 239.43 mm
Take Ds = 250.00 mm

Step 2: Deemed to Comply Span-to-Depth Ratio for Reinforced Slab

< AS 3600 9.3.4.1>

Permanent, G 7.25 kPa (Slab Self Weight + 1kPa Superimposed Load)


Imposed, Q 10.00 kPa AS 1170 Table 3.1 Physical Activities and storage (assu

k3 0.95 <9.3.4.2>
k4 1.75 Exterior
s 0.70 AS 1170
l 0.40 AS 1170
Kcs 2.00 (Assume no steel reinforcement in compression zone)
Ec 30100 M Pa <Table 3.1.2>
Ln 5100 mm
Ln+D 5350 mm
L 6000.00
Lef 5350.00 (lesser of Ln+D or L)
Total Deflection Incremental Deflection
Fdef <9.3.4.1> 36.75 kPa
/ Lef 0.004 (1/ 250)
Lef/d < 24.69
d > 216.67

Minimum d 253.71 mm
Minimum Ds 321.71 mm
Round off Ds 325.00 mm
So, take Ds 350.00 mm Same as Office Slab, construction e
d 282.00 mm

Step 3: Design Load , Fd in kPa


1.2 G 11.70 kPa
1.5 Q 15.00 kPa
Fd = 1.2 G+ 1.5Q 26.70 kPa
Pa Superimposed Load)
sical Activities and storage (assume 1.25 m of storage)

pression zone)
Incremental Deflection
29.50 kPa
0.002 (1 /500)
21.09
253.71

as Office Slab, construction ease


L1 L2 L3
6000 6000 6000

L11 L12 L13 L21 L22 L23 L24


3000 1500 1500 1500 1500 1500 1500
3000 1500 3000 1500 1500 3000
3000 1500 3000 1500 1500 3000
4500 3000 3000 3000
Segment 4 Segment 5 Segment 6
3000 6000 6000

Y-DIRECTION
L1 5000 mm
L2 5000 mm

L11 L12 L13 L14 L21 L22 L23


1250 1250 1250 1250 1250 1250 1250
1250 1250 1250 2500 1250 1250
1850 2500 2500 2500

Segment 1 Segment 2 Segment 3


3100 5000 3100
X-DIRECTION
X

column strip
Middle Strip

L31 L32 L33 L34


1500 1500 1500 1500
3000 1500 1500 1500
3000 1500 1500 1500 Extend
3000 3000 2100 600 18600
Segment 6 Segment 7
6000 3600 18600
L24
1250
1250 Extend
1850 600 11200 (OK)

Segment 3
3100 11200 (OK)
X-DIRECTION

olumn strip
Middle Strip

Bottom Span= Top Span


Span, L 6000
Span Limit, L/2 3000

(OK)

X
Y

Middle strip
column strip

Take middle span


Span, Lo 6000
Span Limit, Lo/2 3000
Segment 1: Edge Design Strip; Lt = 3100 mm

Step 1: Total Static Moment

Depth of flat slab, Ds 350.00 mm


d 282.00 mm
f'c 32 Mpa

Permanent Action, G 9.75 kPa


Imposed Action, Q 10.00 kPa
Fd= 1.2 G+ 1.5 Q 26.7 kPa
Step 2: Moment Distribution
AS 3600 Table 6.10.4.3 (A) and (B)
M1 M2
Distribution Factor -0.65 0.35
M*(kNm) -228.4598705945 123.016853397

AS 3600 Table 6.9.5.3


Column Strip M1 M2
Distribution Factor 0.75 0.5
M*(kNm) -171.3449029459 61.5084266985
M*/m (kNm/m) -92.6188664572 33.2477982154

Half Middle Strip M1 M2


M*(kNm) -57.11 61.51

Step 3: Ast for Column Strip

Most critical M*/m 92.62 kNm/m


Aggregate size 20.00 mm
Bar diameter 16.00 mm

Minimum c/c spacing 30.00 max (1.5 a, db, 25)


Maximum c/c spacing 300.00 min (300, 2 Ds)

Ast min req (flexure) 707.7085741918 mm2


Ast min req (moderate cont) 1225.00 mm2
75% of Ast (mod control) 918.75 mm2

Ast required (greatest) 918.75 mm2

Bar Spacing 300 275


Ast required per bar 275.63 252.66
Bar diameter required 18.73 17.94
Bar diameter used 16.00 16.00

Choose N16-200, Ast 1005.00 mm2


Spacing chosen 200.00 mm
Final dy 282.00
Step 4: Moment Capacity Check

2 0.904 > 0.85


Take 2 0.85
0.826 < 0.85 (OK)
T= Cc
T= Ast* Fsy 502500 N
Cc= 2*f'c**kud*b 6335750.40 ku
T= Cc, ku 0.08
1.1040788438 > 0.8
Take 0.8

Mu 109.54 kNm/ m

Step 5: Ast reinforcement

No of bar 10
Column Strip M1 M2
M* per meter -92.62 33.25
Ast reinforcement 10 N12-150 10 N12-150

No of bar 7
Half Middle Strip M1 M2
M* per meter -45.69 49.21
Ast reinforcement 7N12-150 7N12-150
t = 3100 mm

Extend 600 mm Lo1


L11 1250 mm Lo2
Column Strip 1850 mm Lo3
L12 1250 mm
Half Middle Strip 1250 mm Mo1
Mo2
Lt 3100 mm Mo3
M3 M4 M5 M6
-0.65 -0.65 0.35 -0.65
-228.4598705945 -220.0332849 118.4794611 -220.0332849
8.4265856945 33.8512746

M3 M4 M5 M6
0.75 0.75 0.5 0.75
-171.3449029459 -165.024963675 59.23973055 -165.024963675
-92.6188664572 -89.2026830676 32.021475973 -89.2026830676

M3 M4 M5 M6
-57.11 -55.01 59.24 -55.01

AS 3600 Clause 9.1.1


AS 3600 Clause 9.4.3.4

250 225 200 175


229.69 206.72 183.75 160.78
17.10 16.22 15.30 14.31
16.00 16.00 16.00 12.00

Bar chosen 16.00


OK

M3 M4 M5 M6
-92.62 -89.20 32.02 -89.20
10 N12-150 10 N12-150 10 N12-150 10 N12-150

M3 M4 M5 M6
-45.69 -44.01 47.39 -44.01
7N12-150 7N12-150 7N12-150 7N12-150
5828.5 mm (Left) L1 6000
5720 mm (Middle) L2 6000
5720 mm (Right) L3 6000

351.48 kNm Column Size 400


338.51 kNm
338.51 kNm
M7 M8 M9
-0.75 0.5 -0.25
-253.8845595 169.256373 -84.6281865
33.8512746 84.6281865

M7 M8 M9
0.75 0.5 1
-190.413419625 84.6281865 -84.6281865
-102.92617277 45.7449656757 -45.74496568

M7 M8 M9
-63.47 84.63 0.00

150 125 100


137.81 114.84 91.88
13.25 12.09 10.82
12.00 10.00 10.00
M7 M8 M9
-102.93 45.74 -45.74
10 N12-150 10 N12-150 10 N12-150

M7 M8 M9
-50.78 67.70 0.00
7N12-150 7N12-150 7N12-150
mm
mm
mm

mm
Segment 2: Interior Design Strip, Lt = 5000 mm

Step 1: Total Static Moment

Depth of flat slab, Ds 350.00 mm


d 282.00 mm
f'c 32 Mpa

Permanent Action, G 9.75 kPa


Imposed Action, Q 10.00 kPa
Fd= 1.2 G+ 1.5 Q 26.7 kPa

Step 2: Moment Distribution


AS 3600 Table 6.10.4.3 (A) and (B)
M1 M2
Distribution Factor -0.65 0.35
M*(kNm) -368.48 198.41

AS 3600 Table 6.9.5.3


Column Strip M1 M2
Distribution Factor 0.75 0.5
M*(kNm) -276.36 99.21
M*/m (kNm/m) -110.5450986748 39.6828559345

Half Middle Strip M1 M2


M*(kNm) -46.06 49.60

Step 3: Ast for Column Strip

Most critical M*/m 110.55 kNm/m


Aggregate size 20.00 mm
Bar diameter 16.00 mm

Minimum c/c spacing 30.00 `


Maximum c/c spacing 300.00 min (300, 2 Ds)

Ast min req (flexure) 707.7085741918 mm2


Ast min req (moderate cont) 1225.00 mm2
75% of Ast (mod control) 918.75 mm2

Ast required (greatest) 918.75 mm2

Bar Spacing 300 275


Ast required per bar 275.63 252.66
Bar diameter required 18.73 17.94
Bar diameter used 16.00 16.00

Choose N16-200, Ast 1005.00 mm2


Spacing chosen 200.00 mm
Final dy 317.00
Step 4: Moment Capacity Check

2 0.904 > 0.85


Take 2 0.85
0.826 < 0.85 (OK)
T= Cc
T= Ast* Fsy 502500 N
Cc= 2*f'c**kud*b 7122102.40 ku
T= Cc, ku 0.07
1.1135654068 > 0.8
Take 0.8

Mu 123.61 kNm/m

Step 5: Ast reinforcement

No of bar 13
Column Strip M1 M2
M* per meter -110.55 39.68
Ast reinforcement 13N12-150 13N12-150

No of bar 7
Top Half Middle Strip M1 M2
M* per meter -36.85 39.68
Ast reinforcement 7N12-150 7N12-150

No of bar 7
Bottom Half Middle Strip M1 M2
M* per meter -36.85 39.68
Ast reinforcement 7N12-150 7N12-150
00 mm

Lo1
Lo2
Column Strip 2500 mm Lo3
Top Half Middle 1250 mm
Bottom Half Middle 1250 mm Mo1
Mo2
Lt 5000 mm Mo3

M3 M4 M5 M6
-0.65 -0.65 0.35 -0.65
-368.48 -354.89 191.10 -354.89
13.5912672492 54.59883

M3 M4 M5 M6
0.75 0.75 0.5 0.75
-276.36 -266.17 95.55 -266.17
-110.5450986748 -106.4677185 38.219181 -106.4677185

M3 M4 M5 M6
-46.06 -44.36 47.77 -44.36

AS 3600 Clause 9.1.1


AS 3600 Clause 9.4.3.4

250 225 200 175


229.69 206.72 183.75 160.78
17.10 16.22 15.30 14.31
16.00 16.00 16.00 12.00

Bar chosen 16.00


OK

M3 M4 M5 M6
-110.55 -106.47 38.22 -106.47
13N12-150 13N12-150 13N12-150 13N12-150

M3 M4 M5 M6
-36.85 -35.49 38.22 -35.49
7N12-150 7N12-150 7N12-150 7N12-150

M3 M4 M5 M6
-36.85 -35.49 38.22 -35.49
7N12-150 7N12-150 7N12-150 7N12-150
5828.5 mm (Left) L1 6000 mm
5720 mm (Middle) L2 6000 mm
5720 mm (Right) L3 6000 mm

566.8979419219 kNm Column Size 400 mm


545.9883 kNm
545.9883 kNm

M7 M8 M9
-0.75 0.5 -0.25
-409.49 272.99 -136.50
54.59883 136.497075

M7 M8 M9
0.75 0.5 1
-307.12 136.50 -136.50
-122.8473675 54.59883 -54.59883

M7 M8 M9
-51.19 68.25 0.00

150 125 100


137.81 114.84 91.88
13.25 12.09 10.82
12.00 10.00 10.00
M7 M8 M9
-122.85 54.60 -54.60
13N12-150 13N12-150 13N12-150

M7 M8 M9
-40.95 54.60 0.00
7N12-150 7N12-150 7N12-150

M7 M8 M9
-40.95 54.60 0.00
7N12-150 7N12-150 7N12-150
Segment 3: Edge Design Strip, Lt = 3100 mm

Step 1: Total Static Moment

Depth of flat slab, Ds 350.00 mm


d 282.00 mm
f'c 32 Mpa

Permanent Action, G 9.75 kPa


Imposed Action, Q 10.00 kPa
Fd= 1.2 G+ 1.5 Q 26.7 kPa

Step 2: Moment Distribution


AS 3600 Table 6.10.4.3 (A) and (B)
M1 M2
Distribution Factor -0.65 0.35
M*(kNm) -228.4598705945 123.016853397

AS 3600 Table 6.9.5.3


Column Strip M1 M2
Distribution Factor 0.75 0.5
M*(kNm) -171.3449029459 61.5084266985
M*/m (kNm/m) -92.6188664572 33.2477982154

Half Middle Strip M1 M2


M*(kNm) -57.11 61.51

Step 3: Ast for Column Strip

Most critical M*/m 92.62 kNm/m


Aggregate size 20.00 mm
Bar diameter 16.00 mm

Minimum c/c spacing 30.00 max (1.5 a, db, 25)


Maximum c/c spacing 300.00 min (300, 2 Ds)

Ast min req (flexure) 707.7085741918 mm2


Ast min req (moderate cont) 1225.00 mm2
75% of Ast (mod control) 918.75 mm2

Ast required (greatest) 918.75 mm2

Bar Spacing 300 275


Ast required per bar 275.63 252.66
Bar diameter required 18.73 17.94
Bar diameter used 16.00 16.00

Choose N16-200, Ast 1005.00 mm2


Spacing chosen 200.00 mm
Final dy 317.00
Step 4: Moment Capacity Check

2 0.904 > 0.85


Take 2 0.85
0.826 < 0.85 (OK)
T= Cc
T= Ast* Fsy 502500 N
Cc= 2*f'c**kud*b 7122102.40 ku
T= Cc, ku 0.07
1.1135654068 > 0.8
Take 0.8

Mu 123.61 kNm/m

Step 5: Ast reinforcement

No of bar 10
Column Strip M1 M2
M* per meter -92.62 33.25
Ast reinforcement 10 N12-150 10 N12-150

No of bar 7
Half Middle Strip M1 M2
M* per meter -45.69 49.21
Ast reinforcement 7 N12-150 7 N12-150
mm

Extend 600 mm Lo1


L24 1250 mm Lo2
Column Strip 1850 mm Lo3
L23 1250 mm
Half Middle Strip 1250 mm Mo1
Mo2
Lt 3100 mm Mo3
M3 M4 M5 M6
-0.65 -0.65 0.35 -0.65
-228.4598705945 -220.0332849 118.4794611 -220.0332849
8.4265856945 33.8512746

M3 M4 M5 M6
0.75 0.75 0.5 0.75
-171.3449029459 -165.024963675 59.23973055 -165.024963675
-92.6188664572 -89.2026830676 32.021475973 -89.2026830676

M3 M4 M5 M6
-57.11 -55.01 59.24 -55.01

AS 3600 Clause 9.1.1


AS 3600 Clause 9.4.3.4

250 225 200 175


229.69 206.72 183.75 160.78
17.10 16.22 15.30 14.31
16.00 16.00 16.00 12.00

Bar diameter 16.00


OK

M3 M4 M5 M6
-92.62 -89.20 32.02 -89.20
10 N12-150 10 N12-150 10 N12-150 10 N12-150

M3 M4 M5 M6
-45.69 -44.01 47.39 -44.01
7 N12-150 7 N12-150 7 N12-150 7 N12-150
5828.5 mm (Left) L1 6000 mm
5720 mm (Middle) L2 6000 mm
5720 mm (Right) L3 6000 mm

351.4767239916 kNm Colume Size 400 mm


338.512746 kNm
338.512746 kNm
M7 M8 M9
-0.75 0.5 -0.25
-253.8845595 169.256373 -84.6281865
33.8512746 84.6281865

M7 M8 M9
0.75 0.5 1
-190.413419625 84.6281865 -84.6281865
-102.92617277 45.7449656757 -45.74496568

M7 M8 M9
-63.47 84.63 0.00

150 125 100


137.81 114.84 91.88
13.25 12.09 10.82
12.00 10.00 10.00
M7 M8 M9
-102.93 45.74 -45.74
10 N12-150 10 N12-150 10 N12-150

M7 M8 M9
-50.78 67.70 0.00
7 N12-150 7 N12-150 7 N12-150
SEGMENT4- EDGE DESIGN STRIP, Lt = 3000 m

Step 1: Total Static Moment

Depth of flat slab, Ds 350.00 mm


d 282.00 mm
f'c 32 Mpa

Permanent Action, G 9.75 kPa


Imposed Action, Q 10.00 kPa
Fd= 1.2 G+ 1.5 Q 26.7 kPa

Step 2: M* for Middle Srip = 2 x M* middle strip for interior support

Half Middle Strip M1 M2


M*(kNm) 0.00 109.88
M*/m (kNm/m) 0 36.6277692188

Step 3: Ast for Middle Strip

Most critical M*/m 36.63 kNm/m


Aggregate size 20.00 mm
Bar diameter 16.00 mm

Minimum c/c spacing 30.00 max (1.5 a, db, 25)


Maximum c/c spacing 300.00 min (300, 2 Ds)

Ast min req (flexure) 707.7085741918 mm2


Ast min req (moderate cont) 1225.00 mm2
75% of Ast (mod control) 918.75 mm2

Ast required (greatest) 918.75 mm2

Bar Spacing 300 275


Ast required per bar 275.63 252.66
Bar diameter required 18.73 17.94
Bar diameter used 16.00 16.00

Choose N16-200, Ast 1005.00 mm2


Spacing chosen 200.00 mm
dx 301.00 mm
Step 4: Moment Capacity Check

2 0.904 > 0.85


Take 2 0.85
0.826 < 0.85 (OK)
T= Cc
T= Ast* Fsy 502500 N
Cc= 2*f'c**kud*b 6762627.20 ku
T= Cc, ku 0.07
1.1095024383 > 0.8
Take 0.8

Mu 117.18 kNm

Step 5: Ast reinforcement

No of bar 16
Middle Strip M1 M2
M* per meter 0.00 36.63
Ast reinforcement 17 N12-150 17 N12-150
00 m

Lo1
Lo2
Column Strip 0 mm
Middle Strip 3000 mm
Mo1
Mo2
Lt 3000 mm

erior support

M3 M4 M5 M6
-82.41 -82.41 109.88 0.00
-27.4708269141 -27.4708269141 36.6277692188 0

AS 3600 Clause 9.1.1


AS 3600 Clause 9.4.3.4

250 225 200 175


229.69 206.72 183.75 160.78
17.10 16.22 15.30 14.31
16.00 16.00 16.00 12.00

Bar chosen 16.00

OK

M3 M4 M5 M6
-27.47 -27.47 36.63 0.00
17 N12-150 17 N12-150 17 N12-150 17 N12-150
4720 mm (Top) L1 5000 mm
4720 mm (Bottom) L2 5000 mm

Column Size 400 mm


223.06248 kNm
223.06248 kNm
150 125 100
137.81 114.84 91.88
13.25 12.09 10.82
12.00 10.00 10.00
SEGMENT5- EDGE DESIGN STRIP, Lt = 4800 m

Step 1: Total Static Moment

Depth of flat slab, Ds 350.00 mm


d 282.00 mm
f'c 32 Mpa

Permanent Action, G 9.75 kPa


Imposed Action, Q 10.00 kPa
Fd= 1.2 G+ 1.5 Q 26.7 kPa
Step 2: Moment Distribution
AS 3600 Table 6.10.4.3 (A) and (B)
M1 M2
Distribution Factor -0.25 0.5
M*(kNm) -109.8833076563 219.7666153125

AS 3600 Table 6.9.5.3


Column Strip M1 M2
Distribution Factor 1 0.5
M*(kNm) -109.8833076563 109.8833076563
M*/m (kNm/m) -36.6277692188 36.6277692188

Half Middle Strip M1 M2


M*(kNm) 0.00 54.94

Step 3: Ast for Column Strip

Most critical M*/m 82.41 kNm/m


Aggregate size 20.00 mm
Bar diameter 16.00 mm
Minimum c/c spacing 30.00 max (1.5 a, db, 25)
Maximum c/c spacing 300.00 min (300, 2 Ds)

Ast min req (flexure) 707.7085741918 mm2


Ast min req (moderate cont) 1225.00 mm2
75% of Ast (mod control) 918.75 mm2

Ast required (greatest) 918.75 mm2

Bar Spacing 300 275


Ast required per bar 275.63 252.66
Bar diameter required 18.73 17.94
Bar diameter used 16.00 16.00

Choose N16-200, Ast 1005.00 mm2


Spacing chosen 200.00 mm
dx 301.00 mm
Step 4: Moment Capacity Check

2 0.904 > 0.85


Take 2 0.85
0.826 < 0.85 (OK)
T= Cc
T= Ast* Fsy 502500 N
Cc= 2*f'c**kud*b 6762627.20 ku
T= Cc, ku 0.07
1.1095024383 > 0.8
Take 0.8

Mu 117.18 kNm

Step 5: Ast reinforcement

No of bar 16
Column Strip M1 M2
M* per meter -36.63 36.63
Ast reinforcement 13 N12-150 13 N12-150

No of bar 8
Left Half Middle Strip M1 M2
M* per meter 0.00 36.63
Ast reinforcement 10 N12-150 10 N12-150

No of bar 8
Right Half Middle Strip M1 M2
M* per meter 0.00 36.63
Ast reinforcement 10 N12-150 10 N12-150
00 m

Lo1
Lo2
Column Strip 3000 mm
Left Middle Strip 1500 mm
Right Middle Strip 1500 mm Mo1
Mo2
Lt 6000 mm
M3 M4 M5 M6
-0.75 -0.75 0.5 -0.25
-329.6499229688 -329.6499229688 219.7666153125 -109.8833076563

M3 M4 M5 M6
0.75 0.75 0.5 1
-247.2374422266 -247.2374422266 109.8833076563 -109.8833076563
-82.4124807422 -82.4124807422 36.6277692188 -36.6277692188

M3 M4 M5 M6
-41.21 -41.21 54.94 0.00
AS 3600 Clause 9.1.1
AS 3600 Clause 9.4.3.4

250 225 200 175


229.69 206.72 183.75 160.78
17.10 16.22 15.30 14.31
16.00 16.00 16.00 12.00

Bar chosen 16.00 mm

OK

M3 M4 M5 M6
-82.41 -82.41 36.63 -36.63
13 N12-150 13 N12-150 13 N12-150 13 N12-150

M3 M4 M5 M6
-27.47 -27.47 36.63 0.00
10 N12-150 10 N12-150 10 N12-150 10 N12-150

M3 M4 M5 M6
-27.47 -27.47 36.63 0.00
10 N12-150 10 N12-150 10 N12-150 10 N12-150
4685 mm (Top) L1 5000 mm
4685 mm (Bottom) L2 5000 mm

Colume Size 450 mm


439.533230625 kNm
439.533230625 kNm
150 125 100
137.81 114.84 91.88
13.25 12.09 10.82
12.00 10.00 10.00
SEGMENT 6- EDGE DESIGN STRIP, Lt = 4700 m

Step 1: Total Static Moment

Depth of flat slab, Ds 350.00 mm


d 282.00 mm
f'c 32 Mpa

Permanent Action, G 9.75 kPa


Imposed Action, Q 10.00 kPa
Fd= 1.2 G+ 1.5 Q 26.7 kPa
Step 2: Moment Distribution
AS 3600 Table 6.10.4.3 (A) and (B)
M1 M2
Distribution Factor -0.25 0.5
M*(kNm) -109.8833076563 219.7666153125

AS 3600 Table 6.9.5.3


Column Strip M1 M2
Distribution Factor 1 0.5
M*(kNm) -109.8833076563 109.8833076563
M*/m (kNm/m) -36.6277692188 36.6277692188

Half Middle Strip M1 M2


M*(kNm) 0.00 54.94

Step 3: Ast for Column Strip

Most critical M*/m 82.41 kNm/m


Aggregate size 20.00 mm
Bar diameter 16.00 mm
Minimum c/c spacing 30.00 max (1.5 a, db, 25)
Maximum c/c spacing 300.00 min (300, 2 Ds)

Ast min req (flexure) 707.7085741918 mm2


Ast min req (moderate cont) 1225.00 mm2
75% of Ast (mod control) 918.75 mm2

Ast required (greatest) 918.75 mm2

Bar Spacing 300 275


Ast required per bar 275.63 252.66
Bar diameter required 18.73 17.94
Bar diameter used 16.00 16.00

Choose N16-200Ast 1005.00 mm2


Spacing chosen 200.00 mm
dx 266.00 mm
Step 4: Moment Capacity Check

2 0.904 > 0.85


Take 2 0.85
0.826 < 0.85 (OK)
T= Cc
T= Ast* Fsy 502500 N
Cc= 2*f'c**kud*b 5976275.20 ku
T= Cc, ku 0.08
1.0989106539 > 0.8
Take 0.8

Mu 103.11 kNm

Step 5: Ast reinforcement

No of bar 16
Column Strip M1 M2
M* per meter -36.63 36.63
Ast reinforcement 13 N12-150 13 N12-150

No of bar 8
Left Half Middle Strip M1 M2
M* per meter 0.00 36.63
Ast reinforcement 10 N12-150 10 N12-150

No of bar 8
Right Half Middle Strip M1 M2
M* per meter 0.00 36.63
Ast reinforcement 9 N12-150 9 N12-150
00 m

Lo1
Lo2
Column Strip 3000 mm
Left Middle Strip 1500 mm
Right Middle Strip 1500 Mo1
Mo2
Lt 6000 mm
M3 M4 M5 M6
-0.75 -0.75 0.5 -0.25
-329.6499229688 -329.6499229688 219.7666153125 -109.8833076563

M3 M4 M5 M6
0.75 0.75 0.5 1
-247.2374422266 -247.2374422266 109.8833076563 -109.8833076563
-82.4124807422 -82.4124807422 36.6277692188 -36.6277692188

M3 M4 M5 M6
-41.21 -41.21 54.94 0.00
AS 3600 Clause 9.1.1
AS 3600 Clause 9.4.3.4

250 225 200 175


229.69 206.72 183.75 160.78
17.10 16.22 15.30 14.31
16.00 16.00 16.00 12.00

bar chosen 16.00 mm

OK

M3 M4 M5 M6
-82.41 -82.41 36.63 -36.63
13 N12-150 13 N12-150 13 N12-150 13 N12-150

M3 M4 M5 M6
-27.47 -27.47 36.63 0.00
10 N12-150 10 N12-150 10 N12-150 10 N12-150

M3 M4 M5 M6
-27.47 -27.47 36.63 0.00
9 N12-150 9 N12-150 9 N12-150 9 N12-150
4685 mm (Top) L1 5000
4685 mm (Bottom) L2 5000

Column Size 450


439.533230625 kNm
439.533230625 kNm
150 125 100
137.81 114.84 91.88
13.25 12.09 10.82
12.00 10.00 10.00
mm
mm

mm
SEGMENT 7- EDGE DESIGN STRIP, Lt = 2745 m

Step 1: Total Static Moment

Depth of flat slab, Ds 350.00 mm


d 282.00 mm
f'c 32 Mpa

Permanent Action, G 9.75 kPa


Imposed Action, Q 10.00 kPa
Fd= 1.2 G+ 1.5 Q 26.7 kPa
Step 2: Moment Distribution
AS 3600 Table 6.10.4.3 (A) and (B)
M1 M2
Distribution Factor -0.25 0.5
M*(kNm) -66.918744 133.837488

AS 3600 Table 6.9.5.3


Column Strip M1 M2
Distribution Factor 1 0.5
M*(kNm) -66.918744 66.918744
M*/m (kNm/m) -31.8660685714 31.8660685714

Half Middle Strip M1 M2


M*(kNm) 0.00 66.92

Step 3: Ast for Column Strip

Most critical M*/m 71.70 kNm/m


Aggregate size 20.00 mm
Bar diameter 16.00 mm
Minimum c/c spacing 30.00 max (1.5 a, db, 25)
Maximum c/c spacing 300.00 min (300, 2 Ds)

Ast min req (flexure) 707.7085741918 mm2


Ast min req (moderate cont) 1225.00 mm2
75% of Ast (mod control) 918.75 mm2

Ast required (greatest) 918.75 mm2

Bar Spacing 300 275


Ast required per bar 275.63 252.66
Bar diameter required 18.73 17.94
Bar diameter used 16.00 16.00

Choose N16-200, Ast 753.00 mm2


Spacing chosen 150.00 mm
dx 307.00 mm
Step 4: Moment Capacity Check

2 0.904 > 0.85


Take 2 0.85
0.826 < 0.85 (OK)
T= Cc
T= Ast* Fsy 376500 N
Cc= 2*f'c**kud*b 6897430.40 ku
T= Cc, ku 0.05
1.1308656592 > 0.8
Take 0.8

Mu 90.32 kNm

Step 5: Ast reinforcement

No of bar 15
Column Strip M1 M2
M* per meter -31.87 31.87
Ast reinforcement 11 N12-150 11 N12-150

No of bar 11
Middle Strip M1 M2
M* per meter 0.00 44.61
Ast reinforcement 8 N12-150 8 N12-150
45 m

Lo1
Lo2
Column Strip 2100 mm
Middle Strip 1500 mm
Mo1
Mo2
Lt 3600 mm
M3 M4 M5 M6
-0.75 -0.75 0.5 -0.25
-200.756232 -200.756232 133.837488 -66.918744

M3 M4 M5 M6
0.75 0.75 0.5 1
-150.567174 -150.567174 66.918744 -66.918744
-71.6986542857 -71.6986542857 31.8660685714 -31.8660685714

M3 M4 M5 M6
-50.19 -50.19 66.92 0.00
AS 3600 Clause 9.1.1
AS 3600 Clause 9.4.3.4

250 225 200 175


229.69 206.72 183.75 160.78
17.10 16.22 15.30 14.31
16.00 16.00 16.00 12.00

Bar chosen 12.00 mm

OK

M3 M4 M5 M6
-71.70 -71.70 31.87 -31.87
11 N12-150 11 N12-150 11 N12-150 11 N12-150

M3 M4 M5 M6
-33.46 -33.46 44.61 0.00
8 N12-150 8 N12-150 8 N12-150 8 N12-150
4720 mm (Top) L1 5000
4720 mm (Bottom) L2 5000

Column Size 400


267.674976 kNm
267.674976 kNm
150 125 100
137.81 114.84 91.88
13.25 12.09 10.82
12.00 10.00 10.00

`
mm
mm

mm

Potrebbero piacerti anche