Sei sulla pagina 1di 10

Class DNVGL

Glass thickness Calculation

DNV/GL - RU-SHIP - PT3 (Page - 627)

The required glass thickness for single pane windows and side scuttles, in mm, can
be calculated from the following formulae:

tr= (b/200) (p) for windows

b= the minor dimension of the window in mm


= factor obtained from the graph in Figure 1
p= design load in kN/m2 as given in Ch.4 Sec.5 [3.5]
tr = required glass thickness in mm.

Ch.4 Sec.5 [3.5]

3.4.1
The external pressure for the aft and forward external bulkheads of superstructures and
deckhouse walls, in kN/m2, shall be taken as:

z=
Tsc = Scantling draft (3.0m)
fd = Coefficient to be taken as
= 4.17817905
Main particulars
Loa 68.5 m
Lbp 61.5 m
B 15 m
D 5m
T 3m
Frame spacing 600 mm
Cb 0.7798 even keel

fc = coefficient, to be taken as:

For exposed parts of machinery casings, fc shall not be take


b1 = breadth of deckhouse at the position considered
B1 = actual breadth of ship on the exposed weather deck at the position conside

= 1
P.g 74
fb = coefficient defined in Table 32

P.g 71
ructures and

Bhd Loc. Of bhd x/l fb


A 51.3 0.834146341 1.221352617
B 49.85 0.810569106 1.19501512
C 47.7 0.775609756 1.15903257
D 45 0.731707317 1.119038519
E 42.2 0.686178862 1.083670682
F 42.2 0.686178862 1.083670682
G 39.6 0.643902439 1.056397234
H 37.8 0.614634146 1.040656603
1

S.no Width mm Height mm Window size ra


1 1500 1350 1.1111111111
2 1980 1350 1.466666667
3 1000 1500 1.5
4 1000 1500 1.5
5 1000 1500 1.5
6 1000 1500 1.5
7 1000 1500 1.5
8 1000 1500 1.5
9 1000 1500 1.5
10 1000 1500 1.5
11 1000 1500 1.5
12 1000 1500 1.5
13 1000 1500 1.5
14 1000 1500 1.5
15 1000 1500 1.5
16 1000 1500 1.5
17 1000 1500 1.5
18 1000 1500 1.5
19 1000 1500 1.5
fn Coefficient

asings, fc shall not be taken less than 1.0

eck at the position considered

L2 = Rule length need not be greater than


= 97% of 64.256
62.328

1. Unprotected fron bhd


2. Side bhds
3. Aft end bhds
2

P tr S.no Bhd Quantity


1A 2
2A 2
3B 1
4B 1
5C 1
6C 1
7D 2
8D 1
9E 1
10 E 1
11 F 1
12 G 1
13 H 2
14 H 1
S.no
1
2
3
4
5
6
ule length need not be greater than 300 m 7
97% of 64.256 8
9
10
9.1552 11
9.1552 12
3.024127131 13
14
3

Width mm Height mm Minor P tr


1500 1350 1350 0.325 15.575 15.18656247
1980 1350 1350 0.275 15.575 13.96960568
1000 1500 1000 0.275 15.575 10.34785606
1000 1500 1000 0.275 15.575 10.34785606
1000 1500 1000 0.275 15.575 10.34785606
1000 1500 1000 0.275 15.575 10.34785606
1000 1500 1000 0.275 15.575 10.34785606
1000 1500 1000 0.275 15.575 10.34785606
1000 1500 1000 0.275 15.575 10.34785606
1000 1500 1000 0.275 15.575 10.34785606
1000 1500 1000 0.275 15.575 10.34785606
1000 1500 1000 0.275 15.575 10.34785606
1000 1500 1000 0.275 15.575 10.34785606
1000 1500 1000 0.275 15.575 10.34785606
Bhd Quantity Width mmHeight mmMinor P tr
A 2 1500 1350 1350 0.325 28.408859515 20.51031606
A 2 1980 1350 1350 0.275 28.408859515 18.86674672
B 1 1000 1500 1000 0.275 12.5 9.270248109
B 1 1000 1500 1000 0.275 12.5 9.270248109
C 1 1000 1500 1000 0.275 12.5 9.270248109
C 1 1000 1500 1000 0.275 12.5 9.270248109
D 2 1000 1500 1000 0.275 12.5 9.270248109
D 1 1000 1500 1000 0.275 12.5 9.270248109
E 1 1000 1500 1000 0.275 12.5 9.270248109
E 1 1000 1500 1000 0.275 12.5 9.270248109
F 1 1000 1500 1000 0.275 12.5 9.270248109
G 1 1000 1500 1000 0.275 12.5 9.270248109
H 2 1000 1500 1000 0.275 12.5 9.270248109
H 1 1000 1500 1000 0.275 12.5 9.270248109
15.575

Potrebbero piacerti anche