With disturbances to the electrical supply being one of the major causes of IT downtime, the UPS
system is regarded as the most critical infrastructure device in the data centre. Interruption to electrical
supply can cost organisations in excess of 100,000 per hour in lost revenues and productivity.
The innovative design of the Borri B8000FXS makes it one of the This sophisticated arrangement of features make this series
most technologically advanced UPS of its kind. ideal for applications where reliability and high performance
Exclusively developed by Borri, the FXS series delivers an advanced are fundamental.
combination of low input current distortion, unity power factor In addition, the FXS range comprises an IGBT input rectier design
input, high overall eciency and maximum load protection with dual DSP (Digital Signal Processing) and C (Micro Controller)
ensuring ultimate power quality. technologies, which provides full digital control. The FXS
conguration guarantees high quality output required by loads
requiring a stable and clean source of power, whilst ensuring that
auxiliary power supplies and processors are no longer single points
of failure as with some other UPS Systems.
3 Year | Warranty
A 3 year warranty is standard on all Borri
YE
RS N
WARRA
impressive warranty due to the superior reliability
and condence in our product.
To the best of our knowledge no other UPS manufacturer can
boast such a lengthy warranty. Not only does this give the
user peace of mind but also has the added benet of reducing
on-going maintenance costs.
As the AC input is always converted to DC and then converted
back to AC, the double conversion process provides complete
electrical isolation of the output from the input, in fact unless the
inverter is switched o the critical load will never see the raw
mains power.
This impressive operational rating provides the user with true eciency without High Level Diagnostics via
compromise. LCD Screen
> Overall efficiency in excess of 95% at half load running in full online double
conversion mode. Dual DSP Controller
> Smart Online eciency of up to 98%
Enhanced Generator
Compatibility
Ultra High Efficiency - Smart Online (SOL)
Whilst we advocate that ultimate protection is only achieved with Online Double
Conversion mode, we also understand that in some situations users will require
ultimate eciency.
With this in mind, the FXS series now features smart online mode (SOL). This mode
signicantly reduces energy consumption as the load is fed primarily through the
bypass line. The SOL function continually monitors the input characteristics of the
supply and the UPS switches to Inverter within 2mS should the control system
experience any anomalies.
www.borri.co.uk
Parallel
Oering parallel options for redundancy or capacity modes, the In the modular arrangement units can be added or removed
B8000 FXS can add future resilience or scalable growth. Up to 8 whilst the system is supporting a load. The smart parallel function
units can be connected in parallel giving a total scalable power enables individual units to shut down based on the load applied,
output of 320kVA. delivering optimum eciency whilst maintaining redundancy.
The FXS series incorporates fully digital, parallel control circuitry Two independent parallel systems can be synchronised to feed
and acts on both active and reactive power on each phase of the downstream STS for seamless transfers.
UPS outputs. This allows accurate load current sharing among the > 8 units in parallel conguration (up to 320kVA)
UPS units even during transient conditions.
> Output synchronisation of separate parallel systems
Parallel control is distributed between all units and > Smart parallel with load based shutdown
communication is achieved through the use of a CAN BUS
connection loop. This eliminates any
single point of failure within
the system and increases Mains
reliability.
Load
The data and text contained within this brochure are for general information only and can not be deemed as definitive, specifications can change without notice.
INPUT
Nominal voltage 220/380, 230/400, 240/415 VAC three phase
Voltage range -20%, +10% from nominal
Frequency 50/60 Hz (4565 Hz)
Power factor 0,99
Current distortion (THDi) 3%
OUTPUT
Nominal voltage 220, 230, 240 VAC single phase 220/380, 230/400, 240/415 VAC three phase
Frequency 50/60 Hz
Voltage regulation 1% static; 2% dynamic 100% load change, <10 ms recovery time
PF acceptable without de-rating Lagging to 0.9 leading
Overload capacity 101125% for 10 min (on-line); 126150% for 1 min (on-line);
500% for 1 cycle (bypass)
Efficiency >95%
EPS (Eco-mode) >98%
Options Parallel capacity/redundancy; isolation transformer; external bypass; external battery cabinets,
battery switch box; battery thermal probe; transformers/ autotransformers for voltage adaptation;
USER INTERFACE
Front panel Graphical LCD display, mimic with LEDs and keyboard
Standard communication ports RS232 serial port, USB port, Emergency Power Off input, battery switch monitoring port
Optional Web/SNMP, ModBus, relay, modem cards; remote panel; shutdown and monitoring software
ENVIRONMENTAL
Operating temperature 0C +40C
Storage temperature -10C +70C
Altitude <1000 m
Audible noise at 1 meter (dBA) <60
STANDARDS & CERTIFICATION
Marking CE
Safety IEC EN 62040-1
EMC IEC EN 62040-2
Test and Performance IEC EN 62040-3
Quality ISO9001 :2000
BORRI LTD Systems House Rotherside Road Eckington Sheffield S21 4HL
Tel: +44 (0)1246 431431 Fax: +44 (0)1246 431444 Email: sales@borri.co.uk Web: www.borri.co.uk
BORRI S.p.A Via 8 Marzo, 2 52010 Bibbiena (Arezzo) Italy
Tel: +39 0575 5351 Fax: +39 0575 561438 Email: info@borri.it Web: www.borri.it