Sei sulla pagina 1di 22

Analysis and Design of Reinforced Concrete Structure-I

CEN 323
Ultimate Strength Design (USD) of Beam:

M u Mn

P u Pn

V u V n

The nominal strength of a proposed member is calculated based on the best current knowledge of member
and material behavior. That nominal strength is modified by a strength reduction factor , less than
unity, to obtain the design strength.

The required strength, should the hypothetical overload stage actually be realized, is found by applying
load factors , greater than unity.

Flexural Design

M n Mu

The distribution of concrete compressive stresses at or near ultimate load have no well-defined shape
parabolic, trapezoidal, or other shape. For this and other reasons, wholly rational flexural theory for
reinforced concrete has not yet been developed. Present methods of analysis, therefore, are based in part
on known laws of mechanics and are supplemented, where needed, by extensive test information.
It has been mentioned before that an exact criterion for concrete compression failure is not yet known,
but that for rectangular beams, strains of 0.003 to 0.004 have been measured immediately preceding
failure. If one assumes, usually slightly conservatively, that the concrete is about to crush when the
maximum strain reaches = 0.003.
Figure 1: Stress distribution at ultimate load
Let

f av (1)
= '
f c

Then (2)
'
C= f c bc

For a given distance c to the neutral axis, the location of C can be defined as some fraction of the

distance. Thus, as indicated in Fig. 1 for a concrete of given strength it is necessary to know only

and to completely define the effect of the concrete compressive stresses.

Extensive direct measurements, as well as indirect evaluations of numerous beam tests, have shown that
the following values for and are satisfactorily accurate.

(3)
Figure 2: Variation of and
with concrete

If this

experimental information is accepted, the maximum moment can be calculated from the laws of
equilibrium and from the assumption that plane cross sections remain plane. Equilibrium requires that
C=T f 'c bc= A s f s

Also, the bending moment, being the couple of the forces C and T, can be written as either

M =Tz= A s f s ( dc ) (4)

(5)
'
M =Cz= f bc ( dc )
c

f s=f y . Substituting this value in Eq. (3), one


For failure initiated by yielding of the tension steel,
obtain the distance to the neutral axis
(6)
As f y
c= '
f cb

A s =bd , the neutral axis distance is (7)


Alternatively, using

f yd
c=
f 'c
M n is then
giving the distance to the neutral axis when tension failure occurs. The nominal moment

obtained from Eq. (4), with the value for c just determined, and
f s=f y ; that is
(8)

f y
2
M n= f y b d 1
( f 'c )
(9)
With the specific, experimentally obtained values for and
given previously, this becomes

fy
(
M n= f y b d 2 10.59
f 'c )
b
The above equation is valid only for a steel ratio less than the balance steel ratio,

'
f u (10)
b= c
f y u + y

Equivalent Rectangular Stress Distribution

A equivalent rectangular stress distribution of concrete stress was proposed by C. S. Whitney and was
subsequently elaborated and checked experimentally by others and accepted in many countries are
presented below

Figure 3: Actual and equivalent stressc distribution at ultimate load


' '
Where
C= f c bc= f c ab from which =
a
f 'c psi

4000 5000 6000 7000 8000


0.72 0.68 0.64 0.60 0.56

0.425 0.400 0.375 0.350 0.325

1=2 0.85 0.80 0.75 0.70 0.65

= / 1 0.85 0.85 0.85 0.86 0.86

Figure 4: Table containing concrete stress block parameter

The concrete compression force at failure in a rectangular beam of width b is


(11)
C=0.85 f 'c ab

From of Eq. (10),

f 'c u (12)
b=0.85 1
f y u+ y

Over reinforced Beams

A compression failure in flexure, should it occur, gives little if any warning of distress.

Why Under reinforced Beams desirable

In Under reinforced beam failure initiated by yielding of the steel, typically is gradual.
Distress is obvious from observing the large deflections and widening of concrete cracks asso-
ciated with yielding of the steel reinforcement, and measures can be taken to avoid total collapse.
Strain-hardening of the reinforcing steel is not considered, which provide substantial strength to
the beam.

That is why to design a beam, which fail by yielding of steel, reinforcement ration, is chose less
b .
than the balance reinforcement ration

ACI provision for under reinforced beam


t
To ensure under reinforced behavior, ACI Code 10.3.4 establishes a minimum net tensile strain at
'
the nominal strength of 0.005 for members subjected to axial loads less than 0.10 f A g . By way of
c

y , the steel strain at the balanced condition, is 0.00207 for f y =60,000 psi .
comparison

t = y =0.005
Using in Eq. (12) provides the maximum reinforcement ratio allowed by ACI code
for beam

f 'c u
max =0.85 1
f y u +0.005

The value of reduction factor depends upon the net tensile strain of steel of which can be
determined by following figure.

Figure 5: Net tensile strain

Minimum Steel Ratio

200
min =
Minimum steel ratio according to ACI 10.5 is fy for flexural member.

Example 1
A rectangular beam has the dimensions
b=10., h=25. ,d=23. , and is reinforced with three No. 8
'
(No. 25) bars. The concrete cylinder strength f c =4000 psi. and yield
f y =60,000 psi .
point of steel is Compute the nominal and design
strength of the section.

Solution:

A s 3 0.79
For this beam reinforcement ratio, = bd = 10 23 =0.0103

f 'c 0.003 4 0.003


Max reinforcement ratio, 0.005=0.85 1 =0.85 0.85 =0.0181
f y 0.003+ 0.005 60 0.008

< 0.005
As the beam is Underreinforced beam

Nominal Moment,
fy
2
M n= f y b d 10.59
( '
fc ) 2
=0.0103 60,000 10 23 10.59
0.0103 60
( 4 )
2,970,000lb=248 ft - kips

M n=0.9 248=223.2 ft - kips


Design Moment,

Example 2

A rectangular beam must carry a distributed live load of 680 plf and support the dead load of a wall
weighing 380 plf, in addition to its own weight, on a simple span of 24 ft. Design the beam for flexure,

using f y =60 ksif 'c =4 ksi .

Solution 1:
The total load acting on the beam includes its own weight, which must be estimated. As a trial a total
depth equal to 1 in. per ft of span and a width of one-half that amount are assumed; the beam weight is
144
estimated as 12 24 / 150=300 plf ,

Dead load self weight +wall dead load=300+380=680 plf

Live load 680 plf

Factored load 1.2 DL+1.6

1.2 680+1.6 680

1904 plf

1
Factored Moment,
M u= l 2
8
Figure: Assumed section
1
1904 242 ft - lb
8

137088 ft - lb

1645056- lb

fy
Now we have, (
M n= f y b d 2 10.59
f 'c )
60
1645056=0.9 60,000 12 212 10.59 ( 4 )
1645056=285.768 106 ( 18.85 )

1645056=285.768 106 2.529 109 2

2.529 109 2285.768 106 +1645056=0

1=0.1069, 2=0.00608
by solving this two degree equation,

assume, =0.00608

f 'c 0.003 4 0.003


Max reinforcement ratio, 0.005=0.85 1 =0.85 0.85 =0.0181
f y 0.003+ 0.005 60 0.008

200
min = =0.003
Minimum steel ratio according to ACI 10.5 is fy

min < < 0.005

with this reinforce ration the beam would be under reinforced one.

A s=bd=0.00608 12 21=1.53 2

This could be provided by two No. 6 (No.19) and two No.5 (No.16) bars in a row which provide a steel

area 1.50 2 , which is sufficiently close to the required steel.

2#6 & 2#5


(1.50)

Figure: Design section


Solution 2:

The total load acting on the beam includes its own weight, which must be estimated. As a trial a total
depth equal to 1 in. per ft of span and a width of one-half that amount are assumed; the beam weight is
144
estimated as 12 24 / 150=300 plf ,

Dead load self weight +wall dead load=300+380=680 plf

Live load 680 plf

Factored load 1.2 DL+1.6

1.2 680+1.6 680

1904 plf

1
Factored Moment,
M u= l 2
8

1
1904 242 ft - lb
8

137088 ft - lb

1645056- lb

f 'c 0.003 4 0.003


Max reinforcement ratio, 0.005=0.85 1 =0.85 0.85 =0.0181
f y 0.003+ 0.005 60 0.008

Taking =0.0181
fy
Now we have,
2
(
M n= f y b d 10.59
f 'c )
0.0181 60
1645056=0.9 0.0181 60,000 b d 2 10.59 ( 4 )
820.84 b d 2=1645056 3

b d 2=2004.11 3

Assume b=10.

Then 10 d2 =2004.11 3

2 2
d =200.41

d= 200.41.

d=14.15.

d 14.5.

Assume a total depth, h=d+ 3.5=14.5+3.5=18.

2
A s=bd=0.018110 14.5=2.62

This could be provided by six No. 6 (No.19) bars in two rows which provide a steel area 2.64 2 ,
which is slightly greater to the required steel.

6#6 bars
(2.64)

Figure: Design section


An improved economy may be possible, refining the steel area based on the actual larger
effective depth and smaller concrete section.

144
Now self weight can be estimated = 10 18/ 150=187.5 190 plf

Dead load self weight +wall dead load=190+380=570 plf

Live load 680 plf

Factored load 1.2 DL+1.6

1.2 570+1.6 680

1772 plf

1 2
Factored Moment,
M u= l
8

1 2
1772 24 ft - lb
8

127584 ft - lb

1531008- lb

fy
Now we have,
2
(
M n= f y b d 10.59 '
fc )
60
1531008=0.9 60,000 10 14.52 10.59 ( 4 )
1531008=113.535 10 6 ( 18.85 )

1531008=113.535 10 6 1.004 109 2

9 2 6
1.004 10 113.535 10 +1531008=0

Solving this two degree equation


1=0.09743, 2=0.015650

Assume, =0.015650

A s=bd=0.0156 10 14.5=2.26 2

This could be provided by three No. 6 (No.19) and three No.5 (No.16) bars in two row which provide a
2
steel area 2.25 , which is sufficiently close to the required steel.

3#6 bars & 3#5


(2.25)

Figure: Alternate Design section

Over reinforced Beams

According to the ACI Code, all beams are to be designed for yielding of the tension steel with
t max
not less than 0.004 and, thus, . Occasionally, however, such as when analyzing
the capacity of existing construction, it may be necessary to calculate the flexural strength of an
fs fy
over reinforced compression controlled member, for which is less than at flexural
failure.

dc
s = u
In this case, the steel strain, c

From the equilibrium requirement that C=T , one can write

'
0.85 1 f c bc= s E s bd

k u =c /d , one obtains a quadratic


Substituting the steel strain from in the last equation, and defining

equation in
k u as follows:

k u2 +m k um=0

As
Here, = as usual and m is a material parameter given by
bd

Es u
m=
0.85 1 f 'c

ku ,
Solving the quadratic equation for


k u = m+
m 2 m
( )
2

2

Neutral axis depth for the over reinforced beam,


c=k u d , after the stress-block depth a=1 c .

f s=E s s
With steel stress the nominal flexural strength is
( a2 )
M n= A s f s d

The strength reduction factor will be equal 0.65 for beams in this range

Practical Consideration in the design of beams

To focus attention initially on the basic aspect of flexural design, the preceding examples were
carried out with only minimum regard for certain practical considerations that always influence
the actual design of beams. These relate to optimal concrete protection, rounding of dimension,
standardization of dimension and selection of bar combination.

a) Concrete protection for reinforcement


ACI Code 7.7

Not exposed
Concrete is cast
directly to Exposed to weather or in contact
in direct contact
ground or with ground
with the ground
weather
2.
Slab 3 1
and
. 1 . 3.
4 ( 2 for No. 5 and smaller
wall
bar)
Beam 1 2. 3.
1 .
and 2
column
1
1 .
( 2 for No. 5 and smaller

bar)

In general, the center of main flexural bars in beams should be placed


1 1
2 3. 1 .
2 from the top or bottom surface to furnish at least 2 of clear

cover
In slabs, 1 in. to the center of the bar is ordinarily sufficient to give the required
3
. cover.
4

To simplify construction and thereby to reduce costs, the overall dimension of


beams, b and h, are almost always rounded to the nearest inch, and often to the
next multiple of 2 in.

1
For slab, the total depth h, is generally rounded to the nearest 2 in. up to 6 in.

and to the nearest in above that thickness.

Selection of Bars and Bar Spacing

No. 14 and No. 18 bars are used mainly in column


Should be arranged symmetrically about the vertical centerline
Many designers limit the variation in diameter of bars in a single layer to two bar sizes
According to ACI Code 7.6, the minimum clear distance between adjacent bars in beam
shall not be less than the nominal diameter of the bars, or 1 in.
When reinforcement are placed two or more layers, the clear distance between layers
must not be less than 1 in., and the bar in the upper layer should be placed directly above
those in the bottom layer.

Rectangular Beams with Tension and Compression Reinforcement

If a beam cross section is limited because of architectural or other consideration, it may happen
that the concrete cannot develop the compression force required to resist the given bending
moment. In that case, reinforcement is added in the compression zone, resulting in a so-called
doubly reinforced beam.

a) Tension and Compression Steel Both at Yield Stress

M n 1=A 's f y ( dd ' )

A
( s A 's )f y d ( a2 ) or
M n 2=

With the definition


= A s /bd
and ' = A's /bd
'
'
M n 2=( ) f y b d 10.592
( f y ( )
f 'c )
The total nominal resisting moment is then
A
( s A's) f y d( a2 )
M n=M n 1+ M n 2= A 's f y ( d d ' ) +

Or
'
' ' '
M n=M n 1+ M n 2= A f y ( d d ) +( ) f y b d 10.59
s
2
( f y ( )
f 'c )
In accordance with the safety provision of the ACI Code, the net tensile strain is checked,
0.005,
and if t this nominal capacity is reduced by the factor =0.9 to obtain the
t
design strength. For between 0.005 to 0.004, must be adjusted.

In doubly reinforced beam, maximum reinforcement ratio should be limited by


max =max + '

b) Compression Steel below Yield Stress


cy
Minimum tensile reinforcement ratio that will ensure yielding of the compression
steel at failure
f 'c d ' u
cy =0.85 1 + '
f y d u y

To be under reinforced beam the reinforced ratio should be less than


'
f
max =0.005 + s'
fy

'
s
' d'
[
Where f =E =E s u d ( u +0.005) f y
s s ]
Then value of c could be found out by solving

cd '
A s f y =0.85 1 f 'c bc + A's u E s
c

Then
a=1 c
Nominal capacity of the section would be

( a2 )+ A f ( dd )
M n=0.85 f 'c ab d ' '
s s
'
20

10

Example 3

A rectangular must carry a dead and live load as shown as figure and its self weight. For
Architectural reason the section is fixed by 10 in. width and 20 in total depth. If
f y =60 ksif 'c =4 ksi , what steel must be provided?

Solution:

144
Self weight can be estimated = 10 20/ 0.150=0.21 klf

Dead load self wei ght+ dead load=0.21+1=1.21 klf

Live load 5 klf

Factored load 1.2 DL+1.6

1.2 1.21+1.6 5

9.452 klf
1
M u= l 2
Factored Moment, 2

1
9.452 72 ft - kips
2

231.57 ft - kips

2778.88- kips

Assuming the tensile steel centroid will be 4 in. below the top face of the beam and that
compression steel, if required, will be placed 2.5 in. above the beams bottom surface. Then
d=16.

First, check the capacity of the section if singly reinforced with reinforcement ratio

f 'c 0.003 4 0.003


0.005 =0.85 1 =0.85 0.85 =0.0181
f y 0.003+ 0.005 60 0.008

The maximum nominal moment that the section can provide is

fy
(
M n= f y b d 2 10.59 '
fc) (
=0.0181 60 10 162 10.59
0.0181 60
4 )
2334.82- kips

M n=2101.33- kips
Because corresponding design moment, , is less than the required

capacity, 2779 -kips , compression steel is needed as well as additional tension steel.

The remaining moment to be carried by the compression steel couple is

2779
M n 1= 2334.82=752.95- kips
0.9
As d is less than the value required to develop the compression reinforcement yield stress (Table
3.2, page 99, Nilson 13th edition), a reduced stress in the compression reinforcement will be used.

[ ]
'
d
f 's=E s 's=E s u ( u +0.005)
d

29000 .00175 ksi

29000 .00175 ksi

50.75 ksi

For the compression reinforcement to obtain the area of steel

' M n1 752.95 2
As= = =1.12i n
'
f ( d d )
s
'
50.75(162.5)

The total area of tensile reinforcement at 60 ksi is

' f 's
A s = bd + As
fy

50.75
0.0181 10 16+1.12
60

3.84 in 2

Four No. 9 bars in two rows will be placed in the tension zone and two No. 7 bar provide slightly
greater than the required steel. 10

4#9

20

14.75

2#7


A final check is made to ensure that the section has sufficient capacity

cd '
A s f y =0.85 1 f 'c bc + A's u E s
c

c2.5
4 60=0.85 0.85 4 10 c +1.20 0.003 29000
c

c2.5
4 60=0.85 0.85 4 10 c +1.20 0.003 29000
c

28.9c 2135.6 c261=0

c 1=6.16c 2=1.47
Solving the equation

c 1.47 , c=6.16

6.162.5
f 's=E s 's= 's=29000 0.003 =51.69 ksi
6.16

17.256.16
t =0.003 =0.0054
6.16

For which =0.9 and a=1 c=0.85 6.16=5.236

Then [
M n =0.9 0.85 4 5.236 10 16 ( 5.236
2 )
+1.2 51.69 ( 162.5 )
]
= 2897.7 - kips

This is greater than


M u , so all right

Potrebbero piacerti anche