Sei sulla pagina 1di 1
om Neeeme ‘echnical Expertise and Innovations Action item Database Opened By Patricia Ravanello Status Assigned To Patricia Ravanello & Job Number (3169 [BJs es)efet oO 24a j Opened Date 04-Feb-03 Part Name Combustion Chamber NEW Record i Target Date 02-Jun-03 Action Entry Point Customer Complaint [2] ew Reports (remem [| View Printable Record j Identify Operation Machine | What Went Wrong? | photos/Problem | Short-Term FIX | ROOT CAUSE Category A. (ea) [@&) Find/Replace Customer Complaint: EAP [bI) Go to Jast Record Tap hill depth correct but 3/8 ~ 16 bottom tagped hole not to print (bottom tay). The measured BB find Your Action items depth of thread! is 1.5” the Jength of the scraw Is 1.75 which dbes not allow proper seating of the ES) Go to Record number screw head, allowing the combustion chamber io “foat™ during production and make castings with button height's out of tolerance, Issue Frequency _ Distribution Chart Corrective Action Status Chart E) |e) Comective Actions by Job Sumber Chart fE) (Ree ee en ome eie (CSSrORAcHOT Associated Standard Operating Procedure: = SOP-O010 Product Realization P $0.00 | $9650.00 Verified by: Date Verified: Validated by: Date Closed: Action Rom Database - copyright Juno 4, 2008, Patricia C. Ravanelio Action ftem Database, Revision: 15, July, 2008 | record: [1] « [1 (o J(br ae) oF 73