Sei sulla pagina 1di 2

SERVICE DATA SHEET ICE MAKER INFORMATION

241639000 Test Cycling


ICE & WATER - AUTOMATIC DEFROST Press the momemtary contact on the ON/OFF switch for
PERFORMANCE DATA
COUNTER DEPTH SIDE BY SIDE - R134a approximately 15 seconds. Ice maker will continue to
NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
65F (18C) Ambient 90F (32C) Ambient
complete the cycle.
Type A with Run/Start Capacitor

Operating Time
Variable Speed
74 to 84%
Standard
32 to 40%
Variable Speed
100%
Standard
55 to 65%
IMPORTANT SAFETY NOTE Water Fill Volume
Water Fill
-2 to 2F 0 to 4F -1 to 3F -1 to 3F
The information provided herein is designed to assist
Adjustment
Freezer Temperature
-19 to -17C -18 to -16C -18 to -16C -18 to -16C Remove cover by
Refrigerator Temperature
34 to 39F 34 to 39F 34 to 39F 34 to 39F qualified repair personnel only. Untrained persons should inserting screwdriver Motor
1 to 4C 1 to 4C 1 to 4C 1 to 4C not attempt to make repairs due to the possibility of electrical in notch at bottom
Gear
5 to 12 psig 5 to 12 psig 5 to 12 psig
Low Side Pressure (cut-in) N/A shock. Disconnect power cord before servicing this TU
43 to 83 kPa 43 to 83 kPa 43 to 83 kPa
and prying cover from R Mounting Ice Maker
appliance.

N
-2 to 2 psig -2 to 2 psig -2 to 2 psig -2 to 2 psig Plate ON/OFF
Low Side Pressure (cut-out)
-14 to 14kPa -14 to 14kPa -14 to 14kPa -14 to 14kPa housing. The water fill Screws Switch

90 to 105 psig 90 to 115 psig 120 to 135 psig 130 to 155 psig IMPORTANT adjustment screw will
High Side Pressure (last 1/3 cycle)
621 to 724 kPa 621 to 793 kPa 827 to 931 kPa 896 to 1069 kPa
Wattage (last 1/3 cycle) 60 to 65 120 to 150 65 to 80 130 to 160
If any green grounding wires are removed during servicing, change the fill time. Mounting
Plate
Amps (running) .7 to 1.1 1.0 to 1.4 .9 to 1.3 1.1 to 1.5 they must be returned to their original position and properly One turn is equal to Screw
Timing
Base Voltage 115 vac (127 vac max) 115 vac (127 vac max) secured. 20cc (.68 oz.). The
Gear

DEFROST SPECIFICATIONS
Thermostat Heater correct fill is 102 to
CAUTION
Cabinet Size
Cut-in Cut-out Watts Ohms
23 25F (-4C) 47F (8C) 450 30
110cc (3.25 to 3.5 oz.). When a water valve is replaced,
Electronic Timer (ADC) Defrost 24 minutes every 6 96 hours of compressor run time. All electrical parts and wiring must be shielded from torch the fill volume must be checked.
CONDENSER FAN MOTOR flame. DO NOT allow torch to touch insulation; it will char at
Watts RPM Amps
2.8 950 CW Opposite Shaft .1 Running
200F and flash ignite (burn) at 500F. Excessive heat will
ICE MAKER SPECIFICATIONS distort the plastic liner.
Electrical 115 vac (127 vac max)
Thermostat
Heater Voltage
Opens at 48F (9C)
85 vac
Closes at 15F (-9C)
NOTE
ICE MAKER CONNECTOR PLUG CONNECTIONS This product comes equipped with an Adaptive Defrost
Wire Number Wire Color Connects to: Control (ADC). To activate manual defrost, press and hold
1 Green/Yellow Ground
2 Yellow Water Valve
the Freezer temperature UP (WARMER) key while pressing
3 Black Line the Fresh Food temperature DOWN (COLDER) key 5 times
4 Light Blue Neutral within 6 seconds. A d in the freezer temperature window
and F in the refrigerator temperature window will display
when the heater is activated. To deactivate manual defrost,
press and hold Freezer temperature UP (WARMER) key while
pressing the Fresh Food temperature DOWN (COLDER) key
IMPORTANT 5 times within 6 seconds. d and F will be displayed until
the defrost cycle is complete. (approx. 8 minutes)
Please return this sheet to its original location.

Potrebbero piacerti anche