Sei sulla pagina 1di 8

Engineering Parameters Supported in Different

Network Systems
This describes mandatory fields and optional fields of the engineering parameters supported in different
network system, such as GSM, WCDMA, CDMA, TD-SCDMA, and LTE. You can refer to these parameters
when you import the engineering parameters of different network protocol.

For details about GSM engineering parameters, see Descriptions of GSM Engineering Parameters.
For details about WCDMA engineering parameters, see Descriptions of WCDMA Engineering
Parameters.
For details about CDMA engineering parameters, see CDMA Engineering Parameters.
For details on LTE engineering parameters, see LTE Engineering Parameters.
For details about TD-SCDMA engineering parameters, see TD-SCDMA Engineering Parameters.

Descriptions of GSM Engineering Parameters

Parameter Mandatory Description Value


(Yes/No)
Indicates the ID of a base transceiver
BTSID Yes station. Data type: character string.
Data type: character string. The length of
BTSName Yes Indicates the name of a BTS. the string is 0 to 99.
Data type: character string. The length of
CellName No Indicates the name of a cell. the string is 0 to 99.
Data type: double; value range: -180.0 to
Longitude Yes Indicates the longitude (degree). 180.0
Data type: double; value range: -90.0 to
Latitude Yes Indicates the altitude (degree). 90.0
Indicates the cell global identity Data type: character string. The length of
CGI No (CGI). the string is 0 to 99.
Indicates the location area code Data type: integer; value range: 0 to
LAC Yes (LAC). 65535
Data type: integer; value range: 0 to
CI Yes Indicates the cell identity (CI). 65535
Indicates the broadcast control
BCCHNo Yes channel number. Data type: integer; value range: 0 to 1023
Indicates the traffic channel (TCH) Data type: character string. The length of
TCHList No list. the string is 0 to 99.
Indicates the base station identity
code (BSIC), which is composed of
the network color code (NCC) and Data type: integer; value range of NCC
BSIC No base station color code (BCC). and BCC: 0 to 7
Parameter Mandatory Description Value
(Yes/No)
AntHeight No Indicates the antenna height. Data type: float; value range: 0 to 100000
Indicates the antenna azimuth
Azimuth Yes (degree). Data type: float; value range: 0 to 360
Indicates the mechanical down tilt
MechTilt No (degree). Data type: float; value range: 0 to 90
Indicates the electric down tilt
ElecTilt No (degree). Data type: float; value range: 0 to 90
Altitude No Indicates the antenna altitude. Data type: float; value range: 0 to 100000
Indicates whether the general packet Data type: character string; value range:
GprsSupport No radio service (GPRS) is supported. Y or N.
Data type: character string. The length of
Polarization No Indicates the polarization mode. the string is 0 to 99.
AntGain No Indicates the antenna gain. Data type: float; value range: 0 to 100.
Data type: character string. The length of
FreqBand
No Indicates the frequency band. the string is 0 to 99.
Indicates whether the enhanced data
rates for GSM evolution (EDGE) are Data type: character string. The length of
EdgeSupport No supported. the string is 0 to 99.
Indicates the frequency hopping Data type: character string. The length of
FH Mode No (FH) mode. the string is 0 to 99.
Data type: character string. The length of
SiteConfig No Indicates the site type. the string is 0 to 99.
Data type: character string. The length of
City No Indicates the city. the string is 0 to 99.
Data type: character string. The length of
Region No Indicates the region. the string is 0 to 99.
Data type: character string. Value:
BTSType No Indicates the type of a BTS. Macrocell and Microcell.
Data type: character string. The length of
AntType
No Indicates the antenna type. the string is 0 to 99.
Indicates the name of a base station Data type: character string. The length of
BSCName No controller (BSC). the string is 0 to 99.
Data type: character string. The length of
ProjectPhase No Indicates the project phase. the string is 0 to 99.
Indicates the routing area code Data type: integer; value range: 0 to
RAC No (RAC). 65535
Indicates the mobile allocation Data type: character string. The length of
MA No (MA). the string is 0 to 99.
Parameter Mandatory Description Value
(Yes/No)
Indicates the type of a tower Data type: character string. The length of
TMAType No mounted amplifier (TMA). the string is 0 to 99.
TMAGain No Indicates the TMA gain. Data type: integer; value range: 0 to 100
Horizontal Indicates the horizontal half-power
Beamwidth No beamwidth (degree). Data type: float; value range: 0 to 360
Vertial Indicates the vertical half-power
Beamwidth No beamwidth (degree). Data type: float; value range: 0 to 360
Data type: character string; value range:

Macro (Default)
Micro
Pico
In Door
CellType No Indicates the type of a cell.
Data type: double; value range: 0 to
CellRadius No Indicates the cell radius (meter). 1000000
Active No Indicates the active state. Value range: Y, N or 0, 1
Indicates whether outdoor carriers
Outdoor No are configured for a cell. Value range: Y, N or 0, 1
Area No Indicates the area. Data type: character string.
DisplayMode No Indicates the mode of diapaly. Data type: character string.

Descriptions of WCDMA Engineering Parameters

Parameter Mandatory Description Value


(Yes/No)
Data type: integer; value range: 0 to
RNCID No Indicates the ID of a RNC. 4095
Data type: integer; value range: 0 to
RAC No Indicates the RAC. 65535
Indicates the location area code Data type: integer; value range: 0 to
LAC No (LAC). 65535
NodeBID No Indicates the ID of a NodeB. Data type: character string
Data type: character string. The length
NodeBName No Indicates the name of a NodeB. of the string is 0 to 99.
Data type: character string. Value:
NodeBType No Indicates the type of a NodeB. Macrocell and Microcell.
SectorID No Indicates the ID of a sector. Data type: character string
CellID Yes Indicates the ID of a cell. Data type: integer; value range: 0 to
Parameter Mandatory Description Value
(Yes/No)
65535
Data type: character string. The length
CellName No Indicates the name of a cell. of the string is 0 to 99.
Indicates the uplink UTRA
absolute radio frequency channel Data type: integer; value range: 0 to
UARFCN Yes number (UARFCN). 65535
Indicates the primary scrambling Data type: integer; value range: 0 to
P-SC Yes code of a cell. 511
Data type: double; value range: -180 to
Longitude Yes Indicates the longitude (degree). 180
Data type: double; value range: -90 to
Latitude Yes Indicates the altitude (degree). 90
Azimuth Yes Indicates the azimuth (degree). Data type: float; value range: 0 to 360
Indicates the total down tilt
DownTilt No (degree). Data type: float; value range: -90 to 90
Indicates the electric down tilt
ElecTilt No (degree). Data type: float; value range: -90 to 90
Indicates the mechanical down
MechTilt No tilt (degree). Data type: float; value range: -90 to 90
Data type: float; value range: -65535 to
AntHeight No Indicates the antenna height. 65535
Data type: float; value range: 0 to
Altitude No Indicates the altitude. 100000
Data type: character string. The length
AntType No Indicates the antenna model. of the string is 0 to 99.
Data type: float; value range: 0 to
AntGain No Indicates the antenna gain. 65535
Indicates the horizontal half-
HorizontalBeamwidth
No power beamwidth (degree). Data type: float; value range: 0 to 90
Indicates the vertical half-power
VerticalBeamwidth No beamwidth (degree). Data type: float; value range: 0 to 90
Data type: character string. The length
FeederType No Indicates the feeder type. of the string is 0 to 99.
Data type: float; value range: 0 to
FeederLength No Indicates the feeder length. 100000
Indicates the channel element of Data type: float; value range: 0 to
NodeBCE No a NodeB. 65535
CellType No Indicates the cell type. Data type: character string; value
Parameter Mandatory Description Value
(Yes/No)
range:

Macro
Micro
Pico
In Door

Data type: double; value range: 0 to


CellRadius No Indicates the cell radius (meter). 1000000
Active No Indicates the active state. Value range: Y, N or 0, 1
Indicates whether outdoor
Outdoor No carriers are configured for a cell. Value range: Y, N or 0, 1
TMAEquipment No Indicates the TMA device. Data type: character string
GroudHeight No Antenna height above the ground Data type: float. Range: 0 to 100000.
Area No Indicates the area. Data type: character string.

CDMA Engineering Parameters

Field Description Value Mandatory


(Yes/No)
PN Pseudo-random number Data type: integer. Range: 0 to 511. Yes
Longitude Longitude Data type: double. Range: -180.0 to 180.0. Yes
Latitude Latitude Data type: double. Range: -90.0 to 90.0. Yes
Azimuth Azimuth (degree) Data type: integer. Range: 0 to 360. Yes
Cell ID Cell ID Data type: integer. Yes
ARFCN Frequency number Data type: integer. Yes
Sector ID Sector ID Data type: integer. Yes
DownTilt Downtilt (degree) Data type: integer. Range: 0 to 90. No
Site ID Site ID Data type: integer. No
Site Name Site name Data type: character string. No
Carrier ID Carrier ID Data type: integer. No
SID System ID Data type: integer. No
NID Network ID Data type: integer. No
Antenna Antenna height (m) Data type: integer. No
Height
BeamWidth Angle of the horizontal lobe (degree) Data type: integer. Range: 0 to 90. No
Field Description Value Mandatory
(Yes/No)
Area Area Data type: character string. No

LTE Engineering Parameters

Field Description Value Mandatory


(Yes/No)
eNodeBID LTE eNodeB ID Data type: character string. Yes
eNodeBName LTE eNodeB name Data type: character string. The length of Yes
the string is 0 to 99.
SectorID Sector ID Data type: character string. Yes
Local CellID Local cell ID Data type: integer. Yes
CellID Cell ID Data type: integer. Range: 0 to 255. Yes
EARFCN The E-UTRA absolute radio Data type: integer. Range: 0 to 65535. Yes
frequency channel number
PCI ID of the primary cell Data type: integer. Range: 0 to 503. Yes
Longitude Longitude Data type: double. Range: -180.0 to Yes
180.0.
Latitude Latitude Data type: double. Range: -90.0 to 90.0. Yes
Azimuth Azimuth (degree) Data type: float. Range: 0 to 360. Yes
eNodeBType LTE eNodeB type Data type: character string. Value: No
Macrocell and Microcell.
CellName Cell name Data type: character string. The length of No
the string is 0 to 99.
DownTilt Downtilt (degree) Data type: float. Range: -90 to 90. No
E-DownTilt Internal E-downTilt (degree) Data type: float. Range: -90 to 90. No
M-DownTilt Machine downTilt angle (degree) Data type: float. Range: -90 to 90. No
GroudHeight Antenna height above the ground Data type: float. Range: 0 to 100000. No
Altitude Antenna altitude Data type: float. Range: 0 to 100000. No
AntennaType Antenna type Data type: character string. The length of No
the string is 0 to 99.
AntennaGain Antenna gain Data type: float. Range: 0 to 100. No
H-Beamwidth Width of horizontal half-power beam Data type: float. Range: 0 to 360. No
V-Beamwidth Width of vertical half-power beam Data type: float. Range: 0 to 360. No
FeederType Feeder type Data type: character string. The length of No
the string is 0 to 99.
Field Description Value Mandatory
(Yes/No)
FeederLength Feeder length Data type: float. Range: 0 to 10000. No
ActiveStatus Cell status (active or not) The value is 0, 1 or Y, N. No
Outdoor Station type (outdoor or not) The value is 0, 1 or Y, N. No
TMA The tower mounted amplifier is Data type: character string. No
available or not
TAC Tracking Area Code Data type: integer. Range: 0 to 65535. No
Data type: double; value range: 0 to
CellRadius Indicates the cell radius (meter). 1000000 No
Area Area Data type: character string. No

TD-SCDMA Engineering Parameters

Field Description Value Mandatory


(Yes/No)
CellID Cell ID Data type: integer. Range: 0 to 65535. Yes
UARFCN Carrier ARFCN Data type: integer. Range: 0 to 65535. Yes
CPID Cell parameter ID Data type: integer. Range: 0 to 127. Yes
Azimuth Azimuth (degree) Data type: integer. Range: 0 to 360. Yes
Longitude Longitude Data type: double. Range: -180.0 to Yes
180.0.
Latitude Latitude Data type: double. Range: -90.0 to Yes
90.0.
RNCID Radio network controller (RNC) Data type: integer. Range: 0 to 65535. No
ID
NodeBID NodeB ID Data type: integer. Range: 0 to 65535. No
NodeBName NodeB name Data type: character string. No
CellType Cell type Data type: character string. No
CellName Cell name Data type: character string. No
DownTilt Downtilt (degree) Data type: float. Range: 0 to 90. No
ElecTilt Internal electronic downtilt Data type: float. Range: 0 to 90. No
(degree)
MechTilt Mechanical downtilt (degree) Data type: float. Range: 0 to 90. No
AntHeight Antenna height above the ground Data type: float. No
Altitude Antenna altitude Data type: float. No
AntType Antenna type Data type: character string. No
Field Description Value Mandatory
(Yes/No)
Antgain Antenna gain Data type: float. No
HorizontalBeamwidth Width of horizontal half-power Data type: float. Range: 0 to 90. No
beam
VerticalBeamwidth Width of vertical half-power beam Data type: float. Range: 0 to 90. No
FeederType Feeder type Data type: character string. No
FeederLength Feeder length Data type: float. No
OnAir Whether the cell is available Value: Y or N. No

Y: indicates the cell is


available.
N: indicates the cell is
unavailable.

Outdoor Whether the cell is an outdoor Value: 0 or 1. No


cell.
0: indicates that the cell is an
indoor cell.
1: indicates that the cell is an
outdoor cell.

TMAGain TMA gain Data type: character string. No


Area Area Data type: character string. No
Parent topic: Importing Engineering Parameters and Neighboring Cell Data

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

Potrebbero piacerti anche