Sei sulla pagina 1di 8

Heating Cable

Heat Tracing Products


Applications
Industrial Process
Electric Heat Tracing Products Maintenance Applications Commercial Applications
Chromalox heating cable line includes cables When industrial process piping and vessels In a large number of regions in the world,
suitable for most process maintenance, pipe must be maintained above the ambient air buildings are susceptible to damage caused by
and vessel freeze protection and roof and gut- temperature, Chromalox has the heating cable water freezing. Primarily, this damage involves
ter de-icing applications. to fit the application. Cables range in the maxi- either the bursting of pipes or structural
mum maintenance temperature from 150F for damage due to the weight of ice and snow
Industrial Heating Cables are ideal for process SRL to 1100F for MI cables. building up on the roof. Chromalox Commer-
maintenance applications. Maintenance cial Application Cables are intended to prevent
temperatures up to 1100F can be achieved in Petroleum Refineries Maintain petroleum this damage.
a variety of hazardous and corrosive environ- and by-products at process temperature
ments. Industrial Cables include: Cooling Tower Pipes
Waste Water Treatment Facilities Prevent
SRL Self-Regulating, Low Temperature the precipitation of NaOH from solutions Parking Garage Drain Lines
SRP Self-Regulating Process Maintenance Food Processing Plants Maintain Chiller Water Lines
viscosity of products in processes such as
SRM/E Self-Regulating, Medium Tempera- chocolate, oils and tallow Exposed Pipe Traps
ture Enhanced
Instrument Lines Exposed Storm Water Pipes
SLL Constant Wattage, Medium Temperature
Storage Tanks Sump Discharge Pipes and Equipment
CWM Constant Wattage, Medium Tempera-
ture Div. 1 and Div. 2 Hazardous Location Appli- Wet Sprinkler Fire Systems, where approved
cations (Contact your Local Chromalox Sales by Local Codes
MI Mineral Insulation, High Temperature office for Div. 1 applications)
Outdoor Sports Facilities and Stadiums
Tube Bundles Pre-Installed/Traced Tube Freeze Protection of Steam Cleaned Lines
Bundles Roof and Gutter De-icing
Power Generating Plants Trace steam
Commercial Application Cables are designed condensate lines and other chemical additive Hot Water Maintenance
to meet specific needs of winterizing applica- lines
tions such as water line freeze protection and
preventing ice damage to building structures. Asphalt Lines
Commercial Cables include:
SRF Self-Regulating Freeze Protection
SRF-RG Self-Regulating Roof and Gutter
Freeze Protection
HWM Hot Water Maintenance Applications

G-2
Heating Cable

Heat Tracing Products


Industrial & Commercial Grade Cables & Control Systems
Heat Tracing Products Section Outline

Type Model Page Type Model Page


Industrial - Application Guidelines G-5 HL Series HL-PC, HL-S, HL-T G-79
Self-Regulating (Div. 1 Connection Kits) HL-ES, D1SL1, DLSL2
Low Temperature SRL G-10 Freeze Protection Thermostats THR, THL, TXR,TXL G-83
Process Temperature SRP G-13 B100/E100 Thermostats G-85
Medium Temperature SRM/E G-16 RBF Heat Trace Sensor (RTD Kit) RBF G-87
Long Line Cable SLL G-19 Tubing Bundle
Constant Wattage CWM, SLL G-22
Pre-Insulated Tubing 2200 Series G-88
Mineral Insulated MI G-25 2210 Series G-90
Hazardous Location Low Temperature Maintenance Self- 2256 LTM, 2266 LTM G-92
Low Temperature HSRL G-31 Regulating Electric Traced Tubing
Medium Temperature HSRM G-34
High Temperature Maintenance 2256 HTM, 2262 HTM G-94
Commercial - Application Guidelines G-38 Self-Regulating Electric Traced
Self-Regulating Freeze Protection SRF G-37 Tubing
Hot Water Maintenance HWM G-45 Constant Wattage Electric Traced 2252 CPD, 2262 CPD G-96
Roof & Gutter SRF-RG G-45 Tubing
Edge Cutter System PLD-EC G-47 Single & Multiple Process Tube 2211-2213 G-98
Snow Melt Mats WSMM G-49 Heavy Steam Traced Bundles for
Snow Melting Controls APS-4C, APS-3C, High Temperature Applications
G-51
SC-40C, PD Pro, GF Tubing Bundle Accessories G-101
to
Pro, LCD-1, CIT-1, DL Series Integrated Temperature RTAS, RTBC, G-105
G-64
GIT-1, SIT6-E, RCU Controls RTAS-EP, RTBC-EP
U Series UPC, UMC, UES, UESL, G-65 Heat Trace Control & Panel Selection G-108
UBC, UAS, CCH-2, to Guide
RTES, SSK, SPA, AT-1, G-70
FT-3, PS-1, PS-3, PS-10 Electronic Controls & Control Panels DTS, ITC, ITAS, ITLS, G-110
ITASC1D2, ITLSC1D2 to
DL Series Integrated RTPC, RTST, RTES G-71 FPAS, FPLS, FPASM, G-142
Connection Accessories RTPC-SL, RTST-SL to G-75 FPLSM
EL Series Standard SSK, PJB, RT-RST, G-76 Skin Effect TTEP G-143
Connection Accessories RT-TST, RT-RES, to G-77
RT-TES Impedance Heating System G-144
General Application Accessories AT-1, FT-3, PS-1, PS-3 G-78
PS-10, BL-1, BL-2, BL-3,
ST-1, CL-1, CCH-2

Industrial Cable Applications Constant Wattage


Self-Regulating Chromalox CWM Constant Wattage Heating Cables are ideally suited for ap-
plications where a particular watt density is required at all times. The heater
Chromalox SRL, SRP and SRM/E Self Regulating Heating Cables provide
element consists of a nichrome wire wrapped around parallel, insulated
the most versatility in heat trace designs and applications. Constructed of a
buss wires. At specific intervals, a short section of insulation is removed

heat tracing
semiconductive heater matrix extruded between parallel buss wires, a self-

products
from alternating buss wires to create connection nodes for the nichrome
regulating cable adjusts its output to independently respond to tempera-
wire. The result is a network of parallel resistors along the entire length of
tures all along its length. As temperatures increase, the heaters resistance
constant wattage cable.
increases which lowers the output wattage. Conversely, as the temperature
decreases, the resistance decreases and the cable produces more heat. The Constant wattage cables are flexible, can be cut-to-length in the field, and
result an energy efficient heating cable. are manufactured for use on voltages from 120 to 480V. Although not suited
for overlapping, its constant output makes it an ideal choice for higher
Self-regulating cables are flexible, can be cut-to-length in the field and can
temperature applications where higher watt densities are required. Equipped
be overlapped without fear of burnout in areas where complex piping and
with a ground braid and optional FEP jacket, Chromalox constant wattage
equipment require additional heat trace cable.
cables are third party tested and approved for use in harsh, corrosive and
Chromalox manufactures low (SRL) Process (SRP) and medium (SRM/E) hazardous areas. Contact your local Chromalox Sales office for hazardous
temperature self-regulating heating cable for use on 120 and 208 to 277V. area designs.
Equipped with a ground braid and optional TPR or FEP jacket, Chromalox
self-regulating cables are third party tested and approved for use in harsh
corrosive and hazardous applications.

G-3
Heating Cable

Heat Tracing Products


Industrial & Commercial Grade Cables (contd.)

SLL Series Long Line Cables Commercial Cable Applications Self-Regulating Roof & Gutter
Chromalox SLL Series Long Line cable Self-Regulating Freeze Protection De-Icing
provides safe, reliable heat tracing for process
Chromalox SRF Self Regulating Freeze Protection SRF-RG Heating Cable is specifically designed for
temperature maintenance and freeze protec-
Heating Cable is a self-regulating cable designed roof and gutter de-icing applications.
tion of pipes, valves, tanks and similar ap-
for the freeze protection of water lines. The self- SRF-RG features a self-regulating matrix that re-
plications. Constructed of industrial grade 16,
regulating matrix allows for overlapping and easy duces output as snow melt requirements decrease
14, 12 or 10 AWG buss wire with metal braid
field installation. SRF also lowers its output and or when warm weather is present.
and fluropolymer overjacketing, SLL ensures
energy consumption as the temperature increases
operating integrity in most hostile industrial The braided and overjacketed construction pro-
thus lowering energy costs. The 16 AWG buss
environments. The 450F (232C) maximum vides reliable moisture protection. The 16 AWG
wires provide for long circuits which reduce the
exposure temperature rating allows steam buss wires allow ample circuit lengths and rugged
number of accessories required.
cleaning of process equipment with up to 300 design. Accessories are available for mounting to
psig steam. A braided and braided with overjacket construc- roofs and gutters.
tion is available. Braided cable should be used
on dry pipes and dry locations. The overjacket
Mineral Insulated construction is suitable for wet locations where
occasional exposure to moisture is expected.
Chromalox MI Mineral Insulated Heating Cables
are the most rugged heating cable in Chromalox's SRF heating cable is not for use in hazardous
product line. Constructed of a solid series resistor locations. Consult the Industrial Cable Products
element embedded in highly compacted mineral in this section for cables suitable for hazardous
insulation, MI cables are built to handle high locations.
temperature, high wattage applications. The series
resistor and mineral insulation are encased in a Self-Regulating Hot Water Maintenance
metallic jacket of Alloy 825 for high temperature
or corrosive applications. HWM Cable is specifically designed for hot water
temperature maintenance applications. HWM
Mineral insulated cables are factory assembled features a self regulating matrix that varies its
and tested, ensuring the highest quality product. output to accommodate changes in ambient or
Since the units consist of a series resistor, virtu- pipe temperature. This cable is designed to make
ally any wattage/voltage/length cable configura- up heat losses through the piping insulation and
tion can be produced within the cable's physical maintain consistent pipe temperatures for sink,
operating limits. Chromalox mineral insulated shower, dishwashing, laundry, and kitchen service
cables are available for use up to 600V and are applications. HWM will maintain temperatures
tested and approved for use in corrosive and haz- between 90F and 140F for these applications
ardous areas. Optional accessories include pulling with service voltages between 120 and 277
eyes and reverse glands. Other special features volts, Circuit lengths up to 500 feet are available.
are also available. HWM cable and accessories provide a low cost
alternative to expensive recirculation systems
for domestic hot water temperature maintenance
applications.

G-4
Heating Cable

Heat Tracing Products


Application & Selection
Guidelines
Step 1 Collect Required performing heat loss calculations. For Com-
General Product Summary Application Data & Determine mercial Freeze Protection, please see Cable
Selection Tables in this section.
This section is designed to assist you in Heat Loss
determining the appropriate cable for use in The second category of data required is the
Application data required can be split into two application and environmental conditions. This
your application.
categories. The first is the heat loss data. This includes:
Step 1 Collect Required Application Data includes:
and Determine Heat Loss Maximum Exposure Temperature
Maintenance Temperature (Power Off Condition)
Step 2 Choose the cable that best meets
Minimum Ambient Temperature Circuit Length Considerations
your specific application parameters based
on the summary. Consideration of application Pipe Size Available Voltage
temperature, exposure temperature, applica-
tion requirements and environmental ratings Insulation Type (or K factor) Hazardous Area Requirements
should be made. Insulation Thickness Type of Pipe (Plastic or Metal)
Step 3 Select Heating Cable Wattage Rating Indoor/Outdoor Installation Chemical Exposure
Step 4 Determine Total Cable Required Maximum Expected Wind Speed Fire Resistance.
Step 5 Determine Circuits and Circuit Required Safety Factor.
Protection Step 2 Select the Cable
Refer to the Technical section of this catalog,
Step 6 Select Appropriate Accessories Determining Heat Energy Requirements Choose the cable that best fits your specific
Pipe & Tank Tracing for details on application parameters and wattage require-
ments.

Heat Tracing Product Features


Industrial Commercial
Features SRL SRP SRM/E CWM SLL Alloy 825 MI SRF SRF-RG HWM
Max. Maintenance Temp. (F) 150 225 302 320 302 900 100 50 225
Max. Exposure Temp. (F)
185 275 420 400 450 1,100 185 185 275
Power Off
Max. W/Ft. 10 15 20 12 12 50 8 12 15
Max. Circuit Length (Ft.) 95-660 55-750 150-750 225-900 7,500 330-1,000 180-660 135-540 500-800
Buss Wire Size 16 16 16 12 16,14,12,10 N/A 16 16 16
120, 120, 120, 120, 120, 120, 120,
Voltages 120-600 Up to 600
208-277 208-270 208-277 208-277, 480 208-277 208-277 208-270

heat tracing
Hazardous Ratings Yes Yes Yes Yes Yes Yes No No No

products
Usable on Plastic Pipe Yes No No No No No Yes Yes Yes
Cut-to-Length in Field Yes Yes Yes Yes Yes No Yes Yes Yes
Field Splicable Yes Yes Yes Yes Yes No Yes Yes Yes
Can be Overlapped Yes Yes Yes No No No Yes Yes Yes
Output Varies with Temp. Yes Yes Yes No No No Yes Yes Yes
Varies Output Along Length Yes Yes Yes No No No Yes Yes Yes
Design of System Simple Simple Simple Simple Involved Involved Simple Simple Simple
Installation of System Easiest Easiest Easiest Simple Simple Involved Easiest Easiest Easiest
Fire Resistance Fair Fair Fair Fair Fair Excellent Fair Fair Fair
Chemical Resistance See Corrosion Guide, next page
Size (Max. In.) .435x.185 .435x 185 .435x.185 .435x.235 .435x.185 0.4 .435x.185 .435x.185 .435x.185
Accessories DL/EL/U D/UL DL/U DL/EL/U U DL/EL/U RG Access. DL/U
Monitor Wire Available Contact Contact
Yes Yes No No No No Yes
Factory Factory
Applications FL,FH, FL,FH, FL,FH, FL,FH, FL,FH,
FL,PL FL RG HWM
PL,PH PL,PH PL,PH PL,PH PL,PH
FL = Freeze Protection PH = Process Maintenance, High Temperature
FH = Freeze Protection, High Exposure Temp. RG = Roof and Gutter De-icing
PL = Process Maintenance, Low Temperature HWM = Hot Water Maintenance

G-5
Heating Cable

Heat Tracing Products


Application & Selection Guidelines (contd.)
Agency Approvals
Area SRL-C SRL-CR SRL-CT HSRL SRM/E-C SRM/E-CT SRP HSRM CWM-C CWM-CT MI SRF-C SRF-CR SRF-RG HWM
Ordinary Area
UL *
Factory Mutual
CSA
ATEX *
Class 1 Div 2, Groups B,C,D
UL *
Factory Mutual
CSA
ATEX *
Class II Div 2, Groups FG
UL *
Factory Mutual
CSA
ATEX *
Class III Div 2
UL *
Factory Mutual
CSA
ATEX *
Class 1 Div 1, Groups B,C,D
UL *
Factory Mutual *
CSA *
ATEX *
Class II Div 1, Groups FG
UL *
Factory Mutual *
CSA *
ATEX *
Class III Div 1
UL *
Factory Mutual *
CSA *
ATEX *
Zone 2 and Zone 22
Factory Mutual *
CSA *
ATEX *
Zone 1 and Zone 21
Factory Mutual *
CSA *
ATEX *
*Class I, Division I, Groups B,C & D - UL, CSA, FM - Contact your Local Chromalox Sales office for design assistance.

Corrosion Guide to Select Proper Cable Construction


Industrial Commercial
Exposure To SRL SRM/E SRP HSRL HSRM CWM SLL Alloy 825 MI SRF SRF-RG HWM
Moisture C, CR, CT C, CT C, CT CT CT C, CT CT Yes C, CR Yes C, CT
Aqueous Solutions of CR, CT CT CT CT CT CT CT No No No CT
Inorganic Compounds
Liquids Organic CT CT CT CT CT CT CT Yes No No CT
Chemicals
Acids or Bases CT CT CT CT CT CT CT No No No CT
Note This is a recommendation guide. Chromalox cannot warrant any Electric Heat Trace against failure by sheath degradation if such failure
is the result of operating conditions beyond the control of the heater manufacturer. It is the responsibility of the purchaser to make the
ultimate choice of sheath material based on knowledge of the chemical composition of the corrosive solution, character of materials
entering the solution, and controls which maintains the process.

G-6
Heating Cable

Heat Tracing Products


Application & Selection Step 3 Select Heating
Cable Wattage Rating
Cable Output vs. Temperature

Guidelines (contd.) After calculating the heat loss


24

in the pipe and adjusting for any Cable Output vs.


Temperature
application deviations, you may 20
determine which cable rating
20 W/Ft.
Required Jacket Material to use. If you have selected a
self-regulating cable you must
Select the appropriate jacket configuration for adjust the output based on 16

the desired level of mechanical and corro- maintenance temperatures,


sive chemical protection. The CR over-jacket using the Thermal Output

Heat Output (W/Ft.)


15 W/Ft.
option can be used when additional mechani- Rating Graphs shown on the indi-
12
cal protection is desired. The CR over-jacket vidual product pages, select
option is required when the cable can be the lowest cable rating that will
exposed to aqueous inorganic chemicals. The provide the pipe maintenance tem- 10 W/Ft.

CT over-jacket option is required when the perature. For Example: A 8


8 W/Ft.
cable can be exposed to organic chemicals or 15 W/Ft. SRM/E cable @ 150F
strong corrosives. Use Corrosion Guide above will output approximately
5 W/Ft.
to determine the correct jacket material option 10 W/Ft. Multiple passes or runs
for the cable type selected. of cable may be required to 4
provide sufficient output per
foot calculated in Step 1. This is
accomplished with parallel runs 0
of cable or spiraling. Contact 30 50 70 90 110 130 150 170 190 210 230 250 270 290 300
your Local Chromalox Sales office. Pipe Temperature (F)

Step 4 Determine Total Length of Step 5 Determine Circuits &


Cable Required Circuit Protection
The total amount of heating cable is Circuit protection depends on the breaker
determined by adding the total footage of size being used and the start-up temperature.
pipe to be traced and adding for allowances The National Electric Code (NEC 1996)
for the components such as flanges, valves, requires the use of ground fault protection
pipe supports; then, multiply by the total breakers for heating cable. Refer to the
number of runs or Wrap Factor determined in specific data of the individual heat trace cable
Step 3. to determine maximum circuit lengths. To
determine the number of circuits required for
(Total Feet of Traced Pipe + Cable Allowance
each pipe, divide the total cable length found
for Components) x # of Runs = Total Cable
in Step 4 by the maximum circuit length found
Length)
in the individual cable data charts. Round up

heat tracing
products
to the next higher number.
Number of Circuits = Cable Length
Maximum Circuit Length
Pipe Component Cable Allowance Estimation
Component Cable Allowance Factor (Ft.) x # Components Total Additional Cable
Flange Pair 1.5 x
Pipe Support 2.0 x
Butterfly Valve 2.5 x
Ball Valve 2.7 x
Globe Valve 4.0 x
Gate Valve 5.0 x
Example: Pipe: 150 feet
Valves: 1 globe valve
Pipe Supports: 2
Flanges: 2
Total Cable Length = [150 + (1 x 4) + (2 x 2) + (2 x 1.5)] x 2 runs
= 161 feet x 2 runs
= 322 feet

G-7
Heating Cable

Heat Tracing Products


Application & Selection Guidelines (contd.)

Design of Multiple Runs when Heat Requirements


Exceed Cable Output Ratings

Insulation

Sensors

Multiple Straight Runs

Heating Cable

Spiral Run

Step 6 Select Controls & General Accessory Descriptions


Application Accessories DL Series
U Series
Chromalox provides a wide range of termina- Designed for Ordinary and Hazardous Area Designed for Ordinary and Hazardous Area
tion accessory and control options for your use in Industrial applications use in Industrial Applications
heat tracing systems needs. Integrated design allows for quick cable Integrated design allows for fast installation
Accessory options range from ordinary area termination
Box design allows easy access for field wir-
under the insulation kits in our EL series all the Line carries worldwide approvals including ing, maintenance and trouble shooting
way through connections and terminations for ATEX and IECex
Division 1 hazardous areas in our HL series. CSA, Factory Mutual and UL approved for
The accessories carry a full complement of Reduced parts count results in fast installa-
ordinary and Hazardous area use (Div. 2)
third party approvals from UL, Factory Mutual, tion times
Canadian Standards, ATEX and IECex. Line includes: Line Includes
Power Connection Power Connection
Controls range from Thermostats for both am- Splice and Tee (connect up to 3 cables)
bient air and pipe/tank sensing applications to Multi Entry Connection (for splice, tee or
multiple power to 3 cables) Below Insulation End Seal
WeatherTrace power distribution and controls
panels through our IntelliTrace line of distribu- Above Insulation End Seal Lighted End Seal (ordinary area use only)
tion, monitoring and control panels. Whether Below Insulation End Seal Ambient Thermostat
your project is a few lines of freeze protection Lighted End Seal Line Sensing Thermostat
or a few hundred lines of process piping we Ambient Thermostat
Line Sensing Thermostat Thermostats also serve as power connection
have the right control option for your needs. for cable - eliminating need for extra power
Lighted End Seal
connection box.
Thermostats also serve as power connection
for cable - eliminating need for extra power
More Information connection box.
is Available Online
on Heat Trace.
Bookmark Your Browser to
www.chromalox.com
and Select Manuals.
G-8
Heating Cable

Heat Tracing Products


Application & Selection Guidelines (contd.)
EL Series EL Controls IntelliTrace ITC Series
Designed for use in ordinary areas for both The EL controls line contains ambient and The lTC is a 1 or 2 circuit microprocessor-
commercial and industrial applications
line sensing controllers for use in Division based temperature controller, switching 40
Low profile designs allow for ease of insula- 1 and Division 2 areas. All products switch Amps per circuit at 100-277 Vac, and may be
tion around connections 22 amps and come in NEMA 4x and NEMA 7 used in either freeze protection or process
Kits include standard electrical terminations rated enclosures. Two models are available in temperature control applications. The ITC's
and heat shrink products familiar to most dual output form. All capillaries are nontoxic compact 10" x 8" x 6" NEMA 4X enclosure
installers oil filled available in 8 and 10 foot lengths. facilitates all of the electrical connections and
Products carry UL, Factory Mutual and CSA it features a high resolution TFT display, PID
Low parts count allows fast termination of
approvals. or On/Off SSR control, selectable soft start
cables
WeatherTrace Control and Distribution program, dual RTD sensor input per circuit,
Third Party Approvals through UL, Factory current load and GFEP monitoring. All process
Mutual and CSA. Panels
variables may be monitored both locally and
Line Includes The Chromalox FPAS, FPASM, FPLS, and remotely. The lTC is designed for line or ambi-
Junction Box FPLSM series panels offer power distribu- ent sensing heat trace applications in hazard-
Pipe Stand off with sealing grommets tion, ground fault protection, individual circuit ous (Class I, Division 2) or non-hazardous
and cable boots alarming, with options for both line sensing areas.
Heat shrink splice and tee kits and ambient sensing control. Line sensing is
Heat Shrink end caps accomplished in conjunction with U SERIES, Should the lTC unit realize a failed sensor, the
DL SERIES or EL SERIES thermostats. Ambi- controller automatically switches into a user
HL Series ent sensing can be accomplished with thermo- adjustable manual output duty cycle. This con-
stats or optional Chromalox solid state 1604 troller provides LED indication of load, power
Specifically designed for use in Division 1
series temperature controllers. The panels and alarm status for each circuit, has front
hazardous areas
are housed in NEMA 4 enclosures for indoor/ panel capacitive touch user interface buttons
Corrosion Resistant housing made of high outdoor applications. NEMA 4X 304 stainless and comes complete with heavy gage stainless
strength cast aluminum steel enclosures may be selected as an option steel mounting brackets.
Reduced parts count for fast installation for more harsh environments. The standard
IntelliTrace Control, Monitoring and
models are available in 12,18,20,30 and 42
Small profiles for ease of insulation Distribution Panels
position panel boards with 100 and 225 amp
Line Includes bus ratings in single and three phase configu- The IntelliTRACE ITAS and ITLS Series is a
Power Connection rations. Branch circuit breakers are available micro-processor based Control/Monitoring
Splice Kit in 20, 25, 30 and 40 amp single pole and two and Power Management and Distribution sys-
Tee Kit pole configurations with 30mA ground-fault tem for Heat Trace Applications. The ITAS and
End Seal Kit equipment protection. Options for Z-purge ITLS Series has models suitable for ordinary
Add on Signal lights for End Seal and systems for hazardous area installation are as well as Class I, Division 2 areas and will
Power Connection available. Sentinel monitoring system is avail- manage 6-72 circuits
able for alarm indication when a circuit loses

self-regulating
Controls Descriptions power. Common alarm available for interface The ITAS and ITLS Control Panel Series pro-
to building management systems. Panels are vides alarms for high / low temperatures, high/
DL Controls
built in a UL 508 certified manufacturing plant low current, ground fault leakage and sensor
The DL Series temperature controls are avail- and carry UL and cUL approvals. faults.
able in four models to handle a broad range
of applications. Models include two ambient DTS Digital Thermostat The 40 Amps per circuit capacity, the Integral
sensing and two line sensing thermostats. Circuit Panel and the Soft Start feature save
The DTS-HAZ is a single circuit controller significant time, installation and maintenance
These high quality models combine On/Off
which switches 30 Amps at 100-277 Vac costs.
temperature control and cable power con-
in Class I, Division 2 areas. It employs SSR
nection in one affordable, convenient easy to The customizable I/O (Sensor) Mapping, the
on/off control, soft start feature, program-
install package. The line includes two 22 amp remote monitoring capability and the wireless
mable paramater values, AC or DC alarm and
capable models for Ordinary Area installations communication option provide desirable pro-
large LED display. It comes complete with a
and two 11 amp capable hermetically sealed cess management flexibility options.
standard pipe stand or optional wall mount as
models for Division 2 hazardous area applica-
well as an RTD sensor. All of this is housed in
tions. Products carry UL, Factory Mutual and
a 6" x 6" enclosure, wich facilitates all wiring
CSA approvals.
needs.

G-9