smart2KV3i/Biooptical

HardwareManual

Ref.No.017002.03052010

Copyright2010
PT.IntisarPrimula
JalanPemuda103
Jakarta13220
Indonesia
Ph.+62214702345(hunting)
Fax.+62214702340
Website:http://www.cardnetic.com
Email :info@intisar.co.id
TableofContents

TableOfContents1
SectionI.Introduction.2
smart2KV3i/Biooptical......3
Spesifications.4
TheCard4
HowtoUsesmart2KV3i/Biooptical...4
SectionII.StepsofInstallation..7
TheContentsofthePackage.7
HardwareSpecifications..8
BasicInstallation...12
A.Installingthesmart2KV3i/Biooptical......12
B.NetworkInstallation...14
C.Turnonthesmart2KV3i/Biooptical.....15
D.EssentialSettings..16
FurtherInstallationforAccessControl..18
SectionIII.SettingtheConfiguration19
Configuringdirectlyfromthesmart2KV3i/Biooptical..19
A.AdminMenu...19
B.TheSetupMenu29
Configuringfromtelnet..33
A.ConnectingtoHyperTerminal...33
B.ConnectingtoaTelnet...35
C.Configuringsmart2KV3i/Bioopticalandrunningsmart2KV3i/Bio
opticalcommandsfromaterminal.36
SectionIV.InstallingDigitalInput.....40
SectionV.ListofParameter..41

1 Hardware Manual smart2KV3i/Bio-Optical


SectionI.INTRODUCTION

Smart2KV3i/bioopticalisanadvancedtimeandattendancebiometricterminalbasedonfinger
print and/or employee identification number using verification/identification mode. This machine also
completedwithkeypad,usedforinputIDnumberwhencardisunused.Providedwithabuildinmemory
capacity128MBSD/MMC.Expandableupto2GB.

Thesingleshelled,plasticcasingmakeSmart2KV3i/bioopticalhasmagnificentshapefitsintoany
environment.Theplasticcasingwithallitselectronicsislockedontoawallmountedblackplateforeasy
installation and maintenance. Also completed with user friendly utility software that can be easily
installed on PC in order to manage and load data. There is also rechargeable battery available, up to 2
hoursofoperatingbackuptime.

smart2KV3I/Biooptical

FrontView RearView

2

Spec
Specifications

Microprocessor 8bithighspeedRISCcontroller
Memory NonVolatileSD/MMCCardsupportsupto2GB,formattedusingFAT16filesystem,transactions
practicallyunlimited(Forcomparison,40.000transactionsonlyneedabout500KBMemory)
RealTimeClock NonStop,Y2KCompliant,backedupby3VLithiumBattery
Display STN,LiquidCrystalDisplaywithBacklit,2linesx16Character/Line,
CharacterSize(WxH)=5x7dots,4.84x8.06mm(0.19x0.317inch)
Keypad Matrix4x4keypadwithbacklit,Membranetypewithtactilefeedback,10NumericKey,2Control
Key,and4FunctionKey.
1AudibleBuzzer 2.3kHZ@85dB
InternalTTLReader 2InternalReaderssupportBarcode(Code39),orMagneticTrack2ISO/ABAbidirectional,or
Wiegand26bit,orRFID(selectable)
*CardReaderisoptional
CommunicationPorts 10MbpsEthernetPort
DigitalInput TTLLevelInput(activeLow)
RelayContactOutput ContactRating0.6A125VAC
PowerSupply 1. WallAdapter,Input220VAC(110VACforUSonly);output9VDC,1000mAmax.
2. 6VDC,1000mAHRechargeableNiCDBattery,forupto2hoursoperatingbackuptime.
3. 3V/500mAHLithiumCoinBatteryCR2450/compatibleasmemory/RTCpowerbackup
PhysicalCharacteristics PlasticCasingSize(WxDxH)147x53x153mm(5.792x2.088x6.028inch),Mass950gr
BiometricSensor FingerprintSensorOpticalBase
FingerprintVerification
AuthenticationFacts:FingerprintandKeypad;orFingerprintonly
EqualErrorRate(ERR):0.1%atmediumsecurity
AdjustableFalseAcceptanceRate(FAR):1/100to1/20.000
AdjustableFalseRejectionRate(FRR):1/100to1/10.000
SensorLifetime:unlimited
RecordVerification9000templates
RecordIdentification<200templates(recommended)
EnrollmentTime:<2seconds
VerificationTime:<2seconds
NumberofTemplates:9000
TemplateSize:<400bytes
Max.2fingersperperson

3 Hardware Manual smart2KV3i/Bio-Optical


card
TheCard
card
Thecard(frontview) Thecard(backview)
Thefrontofthecardcontainslogo,photos, Thebackofthecardcontainsbarcodeand/ormagnetic
or/andwritings,example: code,example:

HowtoUsesmart2KV3i/Biooptical
how

1.Slideinthecardaccordingtotheinstructioninandoutonthemessageboard

Ifthesmart2KV3i/Bioopticalusesbarcodereader
Whengoingin Whengoingout


Slide in Card
Slide in Card

barcode
barcode

4

Ifthesmart2KV3i/Bioopticalusesmagneticreader
Whengoingin Whengoingout


Slide in Card Slide in Card

magnetic

magnetic




Ifsmart2KV3i/Bioopticalusingwiegandreader

5 Hardware Manual smart2KV3i/Bio-Optical



Place card next to a

wiegand reader or slide
card to wiegand reader

Cardnetic




2. Placedyourfingerontofingersensor.



3. Ifthepersonmaypassthenthemessagewillbe:
DateTime
In/Out
Ifnotthemessagewillbe:

DateTime
Personnotregistered

Important!!!
; Usethecardonlyonverificationmode,onidentificationmodedirectlyfromstep2.

6
SectionII.STEPSOFINSTALLATION
TheContentsofthePackage
Insidethepackageyouwillfind:
Thesmart2KV3I/Bioopticalkeyreader, LANCablewithRJ45,amount:1
amount:1



*Cardreaderisoptional.

InstallationCDincludingUsersManuals, Adaptor,amount:1
amount:1


Screws,amount:several TestCard,amount:several
HexKeys,amount:1 GroundCable,jumlah:1


Ifsmart2KV3I/Bioopticalisusedforaccesscontrol,thepackagewillalsocontains:
Adaptor,amount:1
Thelockforthedoor,amount:1
Hard

7 Hardware Manual smart2KV3i/Bio-Optical


HardwareSpecifications

Thekeyreader

Note:CardReaderonlyuseonverifymode.CardReaderisoptional.

8
Thesmart2KV3I/BioopticalMotherboardBlueprint

9 Hardware Manual smart2KV3i/Bio-Optical


10
Screwboard:
PINnamesstartfromlefttoright:

No PINName Descriptions

1. GND Ground

2. DCIN 9VoltDCInput

3. RX0 RXRS232

4. TX0 TXRS232

5. CTS CurrentlyNotavailable

6. RTS CurrentlyNotavailable

7. GND Ground

8. +5V +5VoltOutput

9. SPR1 Spare1

10. SPR2 Spare2



11. D RS485D

12. D* RS485D*

13. DOOR DoorSensor

14. REX RexButton

15. K1CM Relay1Common

16. K1NO Relay1NormallyOpen

17. K2NC Relay1NormallyClosed

18. K2CM Relay2Common

19. K2NO Relay2NormallyOpen

20. K2NO Relay2NormallyClosed

11 Hardware Manual smart2KV3i/Bio-Optical



BasicInstallation
A.Installingthesmart2KV3i/Biooptical

1.Turnthelockclockwisetoopenit.Thelockwill 2. Open the back casing of smart2K/Web by pulling


beinverticalposition. the upper portion of the back plate. If you cannot
open the case, try to open it with a tool. Put the
tool inside the back plate hole and pull the back
plateusingthetool.



3. After you open the casing, put the back plate 4. Hang the front part of the smart2K/Web on the
back plate to have more convenience in attaching
onthewall.Firmlysecurewithfourscrewsor
thecables.
nails as appropriate for the surface.
Remembertoslipthecablesthroughthehole
ontheplate.


DonotplugintheACadaptoryet!!!

12

5.Screwthegroundingcableatthebackofthebox. 6.WiringthePowerSupply(Adaptor)
Connect the positive (+), which is usually
marked, of the +9 Vdc Power Supply
(Adaptor) wire to pin 2 of the screw board
and the negative () part to pin 1. Then,
plugthepowersupply(Adaptor)to110Vac
poweroutlet.

Note:groundingcablehastobeplantedtotheearth
later on and measured with ohmmeter get
max4ohmgroundresistance.


WARNING: do not reverse the voltage (do not
connect+toorto+)

13 Hardware Manual smart2KV3i/Bio-Optical


B.NetworkInstallation
Therearethreekindsofnetworkselectionyoucanchoose:




ConnectingtoEthernet
1. InsertoneoftheendstheEthernetcable(RJ45 2.Connectotherendoftheethernetcableto
maleconnector)toEthernetconnectorof modem,LANcard,orhub.
smart2KV3I/Bioopticalmotherboard. Ifthesmart2KV3I/Bioopticalisturnedon
andtheEthernetconnectionisfine,the
greenlightnexttotheEthernetconnection
willbeturnedonandtheredonewillblink.

14

C.Turnonthesmart2KV3I/Biooptical

1. When you finished wiring the Power Supply and the communication cable, 2.Thenlocktheback
closethebackplatetightly casing (get the
key in the
horizontal
position).


2. ThenPressthepowerbuttononthetoprighthandcornerofthesmart2K/Webkeypadtoturnonthe
smart2K/Web.Themessageboardwillbeturnedon.

Date Time
-IN Direction-->trans data<--Out Direction

4.Plantthegroundingcable.
Remember to measure the grounding cable first and make sure that the ohmmeter shows a number
lessorequalthan4ohm.Plantitorconnectittoanironbarwhichisplantedintheground.

15 Hardware Manual smart2KV3i/Bio-Optical


D.EssentialSettings

1.SettingInstallationDate
1. KeyinCandEnter().Thismessagewillappearonthemessageboard:
14:41TUE02/11
PASSWORD:

2. Enter12345forthepassword.Thismessagewillappear:
SetUp
SetTimeAndDate

3. PressEnter()..Thismessagewillappear:

200710302141906

4. AndinsertthecurrentdateandtimeinthisformatYYYYMMDDWHHMMSS.
YYYYiscurrenttheyear,example:2007
MMistheMonth,example:10
DDistheDate,example:30
Wisthedayofweek(0=Sunday,1=Monday,etc),example:2
HHisthecurrenthour,example:14
MMisthecurrentminute,example:19
SSisthecurrentsecond,example:06
ThenpresstheEnterbutton().
NOTE:toeraseusetheF4/button.

5. PressEnter().

6. PressCtoclosemenu.

2.IfyouuseEthernetconnection,SetIPAddress/PeerAddress.

16
1. KeyinCandEnter().Thismessagewillappear:

14:41TUE02/11
PASSWORD:

2. Input12345againforthepassword.TheSetUpmenuwillappearimmediately
afteryouveloggedin.
SetUp
SetTime/Date

3. PressF1/once.
SetUp
SetParameter

4. PressEnter().

001Addr.No007


5. PressCtocleartheparametercode.
__Addr.No007


6. Inputthe204.

7. PressEnter().

204IPAddress
192.168.2.35

8. PressEnter().

204IPAddress
_

9. InputthenewIPAddress.UseEnter()toskipthedots.
10. PressEnter().
11. PressCtwicetogobacktomainmenu.

12. PressCagaintoclosemenu.

17 Hardware Manual smart2KV3i/Bio-Optical


furt
FurtherInstallationforAccessControl
Toconnectthesmart2KV3I/Bioopticalsothatitcancontroltheopeningofthedoor,youwillneed
todomoreinstallation.
1. Turnoffthesmart2KV3I/Biooptical.
2. Openthesmart2KV3I/Biooptical.
3. Connectthe()ofthelocktothe()oftheadaptor.
4. Connectthe(+)ofthelocktoN0ofthescrewboard.
5. Connectthe(+)oftheadaptor(usuallymarked)toCOMofthescrewboard.
Example:controlling12VDCElectricLock.


Example:
Theconnectiononthelock: Theconnectiononthescrewboard:


6. Plugintheadaptor.
7. Setparameter211RL1Modeto001.
8. Setparameter209Relay1Dur(lengthofrelaytimeofRelay1)tohowmanysecondsyou
wishtherelaytoexist.1000=1second.
Note:
SeesectionVParameterList.
Besideusingparameter,youcanalsosetuptheconfigurationbyusing
smart2KV3I/BioutilitysoftwaresectionHardwareConfigurationfolder
Outputs.

18

SectionIII.SETTINGTHECONFIGURATION
Therearetwowaystoconfigurethesmart2KV3I/Biooptical:
a. Directlyonthesmart2KV3I/Biooptical.

b. FromTelnet.
Configuringdirectlyfromthesmart2K/v3i
Configuringdir
Thesmart2K/V3iBiohastwokindsofmenu:theadminmenuandthesetupmenu.

A.AdminMenu:
1.RegisteringUsers:
1. PressCandpressEnter().Thismessagewillappearonthemessageboard:
14:41TUE02/11
PASSWORD:

2. Enter 14789 or the Admin password for the password. This message will
appear:
Setup
Enroll/Register

3. PressEnter().Thismessagewillappear:
ENTERID#:
_

4. YoucaninputyouIDby:
a. InputyourIDnumberbytypingitonthekeypad.
b. Slideinyourcard.
AfterIDhasbeeninputedthismessagewillappear:

ID#:1234567
PlaceFinger!

5. Placeyourfingeronthefingersensor.
6. Ifacceptedthismessagewillappear:
2NDFINGER?
Yes=EnterNo=C

7. Ifyouwishtoinputanotherfinger,pressEnter().IfnotPressC.

19 Hardware Manual smart2KV3i/Bio-Optical


2.DeleteUserbyUser:
1. PressCandpressEnter().Thismessagewillappearonthemessageboard:
14:41TUE02/11
PASSWORD:

2. Enter 14789 or the Admin password for the password. This message will
appear:
SetUp
Enroll/Register

3. PressF1/once.Thismessagewillappear:
SetUp
Delete/Erase

4. PressEnter().Thismessagewillappear:
DeleteFinger
DeleteAll

5. PressEnter().Thismessagewillappear:
DeleteFinger
DeleteSingle

6. PressEnter().Thismessagewillappear:
ENTERID#:
_

7. YoucaninputyouIDby:
a. InputyourIDnumberbytypingitonthekeypad.
b. Slideinyourcard.
AfterIDhasbeeninputedthismessagewillappear:

ENTERID#:
SUCCESS!



8. Ifyouwishtodeletemoreusers,inputID.Else,pressC.
9. PressCagaintoquitAdminMenu.

20


3.DeleteAllUsers:
1. PressCandpressEnter().Thismessagewillappearonthemessageboard:
14:41TUE02/11
PASSWORD:

2. Enter 14789 or the Admin password for the password. This message will
appear:
SetUp
Enroll/Register

3. PressF1/once.Thismessagewillappear:
SetUp
Delete/Erase

4. PressEnter().Thismessagewillappear:
DeleteFinger
DeleteAll

5. PressEnter().Thismessagewillappear:
DeleteFinger
SUCCES!

6. PressCtoquitAdminMenu.











21 Hardware Manual smart2KV3i/Bio-Optical





4.Choosingsecuritysetup.
1. PressCandpressEnter().Thismessagewillappearonthemessageboard:
14:41TUE02/11
PASSWORD:

2. Enter 14789 or the Admin password for the password. This message will
appear:
SetUp
Enroll/Register

3. PressF1/untilthismessagewillappear:
SetUp
SecurityLevel

4. PressEnter().
SecurityLevel:
Medium

5. ChoosethesecuritytypeyouwishbypressingF1/orF2/.PressEnter().
Note:
Low
Medium
High

6. PressCtoreturntothemainmenu.

22

1. Fingers

Thisfeatureisusedtokonwhowmanyfingerslisted.

1. PressCandEnter().Thismessagebelowwillappear:
14:41TUE02/11
PASSWORD:

2. Enter 14789 or the Admin password for the password. This message will
appear:
SetUp
Enroll/Register

3. PressF1/untilthismessagewillappear:
SetUp
Fingers


4. PressEnter().Thismessagebelowwillappear:
SetUp
0

5. PressCtoreturntothemainmenu.

23 Hardware Manual smart2KV3i/Bio-Optical



6.FastMode.
Thisfeatureisusedtosetupthesearchingspeedwhenidentificationmodeactivated.

1. PressCandEnter().Thismessagebelowwillappear:
14:41TUE02/11
PASSWORD:

2. Enter 14789 or the Admin password for the password. This message will
appear:
SetUp
Enroll/Register

3. PressF1/untilthismessagebelowappear:
SetUp
FastMode



4. PressEnter().Thismessagebelowwillappear:

FastMode6
New:_

5. Inputthedesiredvalue.Thismessagebelowwillappear:

FastMode6
New:_

Note:
0:Slowest
6:Fastest


6. PressCtoreturntothemainmenu.

24

7.ImageQuality.
Thisfeatureisusedtodeterminethetresholdvalueduringenrollment
1. PressCandEnter().Thismessagebelowwillappear:
14:41TUE02/11
PASSWORD:

2. Enter 14789 or the Admin password for the password. This message will
appear:
SetUp
Enroll/Register

3. PressF1/untilthismessagebelowisappear:
SetUp
ImageQuality

4. PressEnter().Thismessagebelowwillappear:
IMAGEQTY:1
New:_

Note:
0:Weakqualification
1:Moderatequalification(Default)
2:Strongqualification
3:Strongestqualification
5. Inputthedesiredargument.Thenthismessagewillappear:

IMAGEQTY:1
New:_

6. PressCtoreturntothemainmenu.

25 Hardware Manual smart2KV3i/Bio-Optical





8.Sensitivity.
Thisfeatureisusedtodeterminethefingerprintsensitivitylevel.

1. PressCandEnter().Thismessagebelowwillappear:
14:41TUE02/11
PASSWORD:

2. Enter 14789 or the Admin password for the password. This message will
appear:
SetUp
Enroll/Register

3. PressF1/untilthismessagebelowwillappear:
SetUp
Sensitivity

4. PressEnter().Thismessagebelowwillappear:

Sensitivity7
New:_

5. Inputthedesiredargument.Thismessagebelowwillappear:

Sensitivity7
New:7

Note:
0:LessSensitive
7:MostSensitive


6. PressCtoreturntothemainmenu.

26

9.SFM3KFIRMWARE.
Thisfeatureisusedtoknowsmart2K/V3IsDSPboardfirmwareversion.

1. PressCandEnter().Thismessagebelowwillappear:
14:41TUE02/11
PASSWORD:

2. Enter 14789 or the Admin password for the password. This message will
appear:
SetUp
Enroll/Register

3. PressF1/untilthismessagewillappear:
SetUp
SFMFIRMWARE



7. PressEnter().Thismessagebelowwillappear:

SFMFIRMWARE
A17C

8. PressCtoreturntothemainmenu.

27 Hardware Manual smart2KV3i/Bio-Optical





10.Lighting.
Thisfeatureisusedtodeterminelightingmode.

1. PressCandEnter().Thismessagebelowwillappear:
14:41TUE02/11
PASSWORD:

2. Enter 14789 or the Admin password for the password. This message will
appear:
SetUp
Enroll/Register

3. PressF1/untilthismessagebelowappear:
SetUp
Lighting


4. PressEnter().Thismessagebelowwillappear:

LightingMode
Outdoor

5. Input the desired argument by pressing F1/ and then press Enter ( ). This
messagebelowwillappear:

LightingMode
Indoor
Catatan:
Outdoor
Indoor

6. TekanCduakaliuntukkembalikemenuutama

28



B.TheSetupMenu

1.Configuringtimeanddate.
a. KeyinCandEnter().Thismessagewillappear:

14:41TUE02/11
PASSWORD:

b. Input12345forthepassword.TheSetUpmenuwillappearimmediatelyafter
youlogin.

SetUp
SetTime/Date

c. PressEnter()
200204117114500
_

d. AndinsertthecurrentdateandtimeinthisformatYYYYMMDDWHHMMSS.
YYYYiscurrenttheyear,example:2002
MMistheMonth,example:04
DDistheDate,example:11
Wisthedayofweek(0=Sunday,1=Monday,etc),example:4
HHisthecurrenthour,example:13
MMisthecurrentminute,example:45
SSisthecurrentsecond,example:00
ThenpresstheEnterbutton().
CATATAN:toerase/backspacepressF4/.
e. PressEnter().

29 Hardware Manual smart2KV3i/Bio-Optical


2. Configuringparameter.
A.ParameterDescription
Theformatoftheparameterisexplainedbelow:

001SetupTerminalAddress(1255)
001istheparametercodenumber
SetupTerminalAddressistheparameterdescription
displayedonthesmart2KV3I/Biooptical.
(1255)istheargumentvaluethatyoucanenter

NOTE:YoucanusethefollowingsyntaxinHyperTerminalorTelnet:
setpar<parametercode><argument>

B.Stepstoconfigureparameterdirectlyfromthesmart2KV3I/Biooptical:
a. KeyinCandEnter()thismessagewillappear:
14:41TUE02/11
PASSWORD:

b. Input12345forthepassword.TheSetUpmenuwillappearimmediatelyafter
youveloggedin.
SetUp
SetTime/Date

c. PressF1/once.
SetUp
SetParameter

d. PressEnter().

001Addr.No007


e. PressCtocleartheparametercode.
__Addr.No007


f. Inputthenewparametercode,example013.

30
g. PressEnter().

013SlideDir002

h. PressEnter().

013SlideDir002
NewValue:

i. Inputthenewargument,example:001

j. PressEnter().

k. PressCtwicetogobacktomainmenu.
l. PressCagaintoclosemenu.
PleaserefertosectionVtoseethecompletelistofparameters.

3. GoDefault.
Thiscommandisusedtoreturntodefaultsetup.
a. PressCandEnter()thismessagebelowwillappear:
14:41TUE02/11
PASSWORD:

b. Input12345forthepassword.TheSetUpmenuwillappearimmediately
SetUp
SetTime/Date

c. PressF1/untilthismessagebelowwillappear.
SetUp
GoDefault

d. PressEnter().Thismessagebelowwillappear.

AREYOUSURE?
ENTER=YesC=No

e. PressCtocancel,andthenpressEnter()toexecute.

f. PressCtoreturntothemainmenu.

31 Hardware Manual smart2KV3i/Bio-Optical



4. Restart.
Thiscommandusedtorestarttheterminal.
a. PressCandEnter().Thismessagebelowwillappear:
14:41TUE02/11
PASSWORD:

b. Input12345forthepassword.TheSetUpmenuwillappearimmediately:
SetUp
SetTime/Date

c. PressF1/untilthismessagewillappear.
SetUp
Restart

d. PressEnter().Thenthemachinewillrestart.

32

l
Configuringfromtelnet

This section describes how you can configure on the smart2KV3I/Biooptical using a
HyperTerminalorTelnetprogram.Followthestepsbelow:

A.ConnectingtoHyperTerminal.
1. ClickstartmenuonyourcomputermonitorandthenchooseProgramAccessories
CommunicationsHyperTerminal
2. ThenConnectionDescriptionWindowwillappearonyourscreentomakeconnection
shownbelow:



3.EnteranynameandchooseaniconfortheconnectionandpressOK.
4.TheConnectTowindowsasinthefigurebelowwillappear.ChooseConnectUsingby
clickingthearrowbutton.




33 Hardware Manual smart2KV3i/Bio-Optical





UsingtheTCP/IP(Winsock).

- For the TCP/IP specify an IP address of the smart2KV3I/Biooptical


then enter an IP address in host address column. Note for the port
numberis23(default).

- ThenclickOK.

5. Then hit the ENTER button on the keyboard and the smart2KV3I/Biooptical will
respond back with SMART2K 2.10 001 that means the smart2KV3I/Biooptical is
readytocommunicate.Thehyperterminalwillgivethefollowingmessage:



NOTE:
Smart2K:isthesmart2Kname

34
2.10 :isthefirmwareversionofthesmart2K
001 :isthesmart2KBioterminalnumber
a. Typeyourcommands.Toseecommandlist,seesectionB.iii
b. ToExitfromHyperTerminal,clickFileexit

B.ConnectingtoaTelnet.
You can use Telnet if the smart2KV3I/Biooptical is using TCP/IP (Winsock) only, you must
assignanIPaddresstothesmart2KV3I/Biooptical.RefertosectionVListofParametersSetting
forexplanationonhowtosettheIPAddressforthesmart2KV3I/Biooptical.
TostartusingTelnetCommunicationfollowtheprocedurebelow:
1. ClickStartMenuoncomputermonitorthenclickRun.IncolumnOpen,typetelnetfollowed
byanIPAddressthatisusedbythesmart2KV3I/Bioopticalasshowninthescreenbelow.

2. ClickOK
3. Thetelnetwindowwillappear.
4. PresstheENTERbuttonandthewindowwilllooklikethefigurebelow:

35 Hardware Manual smart2KV3i/Bio-Optical



5. Typeyourcommands.Toseecommandlist,seesectionC
6. ToExitfromHyperTerminal,clicktheXbuttononthetoprightofthewindow.

SectionIV.INSTALLINGDIGITALINPUT
DigitalInputforsmart2KV3I/BioopticalREXbutton.

TheshapeofaRexButton:

1.Hardwareconfiguration:
PushSwitchButton smart2KV3I/Biooptical
1 REX
2 GND



2.Parametersetup.ToseehowtosetparametersseesectionIII,ParameterConfiguration.

SetParameter211(RL1Mod)withvalue50331665.

3.Restartsmart2KV3I/Biooptical.

36

C.Configuringandrunningsmart2KV3i/Bioopticalcommandsfromaterminal

BelowarethelistofcommandsthatcanbeusedbothusingtelnetandHyperTerminal.
NOTE:thetypedcommandscannotbeseen,buttheresultscan.Forexample:type
DIRFILESandtheresultwillbe:

Howtodosetupparameterwithterminals:
Tohaveaparametersetupfromterminalstypethecommandbelow:
CommandFormat:
Commandphrase<argumen1><argumen2><argumen3>
Forexample,togetparametervalueforparameternumber23<argument1>,youcan
typethefollowingcommand:
PAR23
Formoreparameterscodeandexplanations,seetheParameterListonsectionVlistof
parametersortypeLISTPAR





37 Hardware Manual smart2KV3i/Bio-Optical



LISTofCOMMANDS

DELFILE(FNAME)
Delfile command is used to delete data in smart2KV3i/Biooptical Memory for a specific
file.

DIR
Dircommandisusedtoviewallthefile/directorylist.

GETVER
Getvercommandisusedtoviewthefirmwareversionofthesmart2KV3i/Biooptical,type
getvertoviewthecurrentfirmwareversion.

LISTPAR
Listparcommandisusedtoviewallthecontentsofsmart2K/Web/Biosparameters.

LOCKSYS
Locksyscommandisusedtolockthesmart2KV3i/Bioopticalsystem(tomakeareadernon
active), usually to process the deleting of data. In this condition, the smart2KV3I/Bio
opticalcannotreadthecard.

PAR(PARNUM)
Par command is used to get or set parameter value of the smart2KV3i/Biooptical as
specifiedbyPARNUM(ParameterNumber).

RESTART
Restartcommandisusedtorestartthesmart2KV3i/Bioopticalsystemincludepower.
SFMPAR
SFMPAR command is used to get DSP parameter using command SFMPAR or set DSP
ParameterwithcommandSFMPAR(ParameterNumber).RefertosectionV.
TYPE
TypecommandisusedtoListallfilecontentusingcommandTYPE(File)ortolistallfinger
usingcommandIDTYPE(TMPTABLE).
ULOCKSYS
Unlocksys command is used to unlock the smart2KV3i/Biooptical system (to make the
readeractive).

38
CommandTable

Perintah Argument1 Argument2 Keterangan Contoh
DIR Directory Daftarfile/directori "DIR\trans"orjust"DIR"
LISTPAR none DaftarsemuaParameter
PAR ParNumber none GetParametervalue "PAR23"
ParNumber ParValue SetParametervalue "PAR231"
(dorestartafterfinish
setparams)
FINGERS none none GetCountofFingers
GETVER none none Getfirmwareversion
TIME none none GetSystemtimeanddate
TIME
String$TIME none SetSystemtimeanddate "200711272124013"
GetFingerData(binary)
(Response:384Byte
TMPDATA FingerIDNo none binarydata)
ResetSystem(Include
RESTART none none Power)
LOCKSYS none none Lockingthesystem
UNLOCKSYS none none Unlockingsystem
FingerIDNo Index Deleteonefinger "DELTEMP111112"
DELTEMP ALL none DeleteAllFinger "DELTEMPALL"
"TYPE
File(MMC/SD) none Listallfilecontent \TRANS\010107.DAT"
TYPE TMPTABLE none ListallfingerID "TYPETMPTABLE"
FingerIDNo+ Binarystream(384
TMPSAVE CR+LF Bytefix) Savefingertemplate
Loadfilewithdata
(Append)
FileName+CR ASCIIstream,"*"as (Requireslinedelay "LOAD
LOAD +LF <EOT> >=10ms) \SYSTEM\AXGROUP.DAT"
"DELFILE
DELFILE File None DeleteFile \TRANS\010207.DAT"
Directory
MKDIR name none CreateDirectory
Directory
RMDIR name none DeleteDirectory
DSPPar
Number none GetDSPParameter (SeeSUPREMADoc)
DSPPar
SFMPAR Number DSPParvalue SetDSPParameter
SETLOGON SlaveAddress Logintoslave "Setlogon2"
TRANSFILE Flagdownload FLAGTRANS
FLAGTRANS NAME transactionfile 210108.DAT
Note:
CommandFormat:
COMMANDPHRASE+''+ARG1(Ifany)+''+ARG2(Ifany)+''+ARG3(Ifany)+CRLF

39 Hardware Manual smart2KV3i/Bio-Optical



SectionV.LISTOFPARAMETERS

Thissectionallowsyoutoknowallkindsofparametersthatareprovided.SeesectionIIIforParameter

DescriptionandSettings.

PAR001Addr.No(1255)

This parameter is used to set up Terminal Address. You can connect up to 255 smart2K/Bio/Web
terminalsandusethisparametertoassignauniqueaddressnumbertoeachterminal.

PAR003TimeMode(03)

Thisparameteristosetupthetimeformat.smart2KV3i/Bioopticalhasseveraltimeformat.
Format Argumen
hh:mmWWDD/MM 0
hh:mmDD/MM/YY 1

Note:
hh representshour
mm representsminute
WW representsdayofweek(0=Sunday,1=Monday,etc)
DD representsdate
MM representsmonth
YY representsyear

PAR004ReaderMd(03)

This parameter is used to set up Reader Mode. The smart2KV3i/Biooptical readercan be set to read
three different kinds of ID card format. The format can be a barcode, a magnetic stripe, or a Wiegand
(proximity).
Format Argument Format Argument
NoReader 0 MagneticStripe 2
Barcode 1 Wiegand 3

40
PAR005Rdr01Dir(14)
ThisparameterisusedtosetupReaderDirection1function.
Mode Argument
In<>Out 1
Out<>In 2
In=In 3
Out=Out 4

PAR006R1IDSPos(136)

ThisparameterisusedtosetupIDStartpositionfromReader1input,availableuntil36digit.

PAR007IDLength(39)

ThisparameterisusedtosetupsystemIDlengthfromeveryIDnumber.Canbe6,9.Defaultvalue6.

PAR008WStarBit(150)WiegandStarbitposition

ThisparameterisusedtodetermineWiegandcardstarbitposition.Defaultvalue9.

PAR009WBitLen(050)Wiegandbitlength

Thisparameterisusedtodeterminewiegandbitlenght.Canbe26,32,40.Defaultvalue26.

PAR010WBitCLen(032)WiegandCardNobitlength

Thisparameterisusedtodeterminewiegandcardnobitlength.Defaultvalue16.

PAR011TapRdr(01)Tapreadertocommunicationport

Thisparameterisusedtoactivateprintreaderdatatocommunicationport.Nilaidefault0.
Mode Argument
Readerdatainputblockedtocommunication 0
Readerdatainputbypasstocommunication(fordebuging) 1

41 Hardware Manual smart2KV3i/Bio-Optical



PAR012ReadCW(09)Barcodecheckwordchecking

ThisparameterisusedtoactivateBarcodeCheckWord.Defaultvalue0.
Mode Argument
Barcodecheckworddisable 0
Barcodecheckwordenable 1

PAR013Func.Key(04)FunctionKeymode

ThisparameterisusedtosetupFunctionKeymodespeciallyforFI,F2,F3,danF4.

Format Argument Descriptions


Disable 0 Func.Keydisable
Enablenotable,notimeout 1 Func.Keyenable,notusingfunc.Keytable
withnoidledisplay
Enablenotable,timeout 2 Func.Keyenable,notusingfunc.Keytable
withidledisplay
Enabletable,notimeout 3 Func.Keyenable,usingfunc.Keytable
withnoidledisplay
Enabletable,timeout 4 Func.Keyenable,usingfunc.Keytable
withidledisplay

PAR014FgrRetry(09)Fingerretryforverification

This parameter is used to determine how many times user can do finger retry for verification. Default
value2.

PAR015IdenSDir(02)DirectionvaluewhileIdentify

Thisparameterisusedtodeterminedirectionvalue/slidedirectionwhenidentify.Defaultvalue0.
Mode Argument
IN 0
OUT 1
LastDir 2

42

PAR016RdBypass(03)Readerbypass*

Thisparameterisusedtosetupreaderbypasswithoutfingerverification.Defaultvalue0.

Mode Argument
Tidakadabypasssamasekali 0
Rdr1bypassfinger 1
Rdr2bypassfinger 2
Note:
*Bitwise

PAR018IdlDspMd(13)*IdleDisplayMode

Thisparameterisusedtochangetheidledisplaymodeinthesmart2KV3i/BioopticalLCDmonitor.You
can specify different messages that can be displayed when smart2KV3i/Biooptical is in idle condition
(noslide).

Display Argument
ShowRd1slidedir 1
ShowRd2slidedir 2
Showrecount 3
Note:
*Bitwise

PAR022AxGroup(01)AXGroupmode

ThisparameterisusedtosetupACCESSCONTROLfunction.
Mode Argument Mode Argument
AccessGroupdisable 0 AccessGroupenable 1

43 Hardware Manual smart2KV3i/Bio-Optical


PAR023Rdr02Mod(13)Reader2mode

ThisparameterisusedtosetupReadermode2function.
Mode Argument
Barcode 1
ABA/Track2 2
Wiegand 3

PAR024Rdr02Dir(14)Reader2Direction
ThisparameterisusedtosetuptheReaderDirection2.
Mode Argument
In<>Out 1
Out<>In 2
In=In 3
Out=Out 4

PAR025R2IDSPos(136)

ThisparameterisusedtoknowIDStartpositionforReader2,availableuntil36digit.

PAR027PeerIPAddressmode(01)

ThisparameterisusedtosetupthePeerIPAddressmode.
Format Argument
PeerIPAddressmodedisable 0
PeerIPAddressmodeenable 1

PAR028JTAGMode(01)

ThisparameterisusedtosetupJTAGEnwhichisusedtoupgradingfirmware.
Format Argument
JTAGdisable 0
JTAGenable 1

44
PAR029AUTHMODE(13)
Thisparameterisusedtosetupordetermineauthentificationmode.
Format Argumen
Verifyonly 1
Identifyonly 2
VerifyandIdentify 3

PAR030OnlineMode(01)

Thisparameterisusedtoactivateonlinemode.
Format Argument
Disable 0
Enable 1

PAR031COM1/RS485BaudRate(02)

ThisparameterisusedtosetupCom1/RS485baudrate.
Format Argument
9600bps 0
19200bps 1
115200bps 2

PAR032AutoSlideDirection/AutoReverseDir(01)

Thisparameterisusedtoactivateautoslidedirection/autoreversedirection.
Format Argumen
Disable 0
Enable 1

45 Hardware Manual smart2KV3i/Bio-Optical


PAR201IPAddr

This parameter is used to set up IP Address (in dotted decimal). IP address will be asked if
smart2K/Web/BiousesaTCP/IP(Winsock)Network.
For example : to set the IP address of the smart2K/Web/Bio to 192.168.1.207 (using
HyperTerminalorTelnet).
type:setpar204192.168.1.207

PAR202GateWay

ThisparameterisusedtosettheGateway(indotteddecimal).

PAR203NetMask

ThisparameterisusedtosettheNetMask(indotteddecimal).


PAR204PeerAdr1

ThisparameterisusedtosettheFirstIPaddressofaPCthatcanbeacceptedbytheterminal,ifEXCLPEER
=1.

PAR205PeerAdr2

This parameter is used to set the second IP address of a PC that can be accepted by the terminal, if
EXCLPEER=1.

PAR206TelnetPort

ThisparameterisusedtoactivateonlineportonTCP/IPmode.Telnetcommunicationhavetobesetup
usingPortNumber23.

46
PAR207PassWd1

ThisparameterisusedtochangetheSetUpPasswordonSetupMenu.Maximumcharacterprovidedis5
character.Withdefaultvalue12345.

PAR208PassWd2
This parameter is used to change the Administration Password on Admin Menu. Maximum character
providedis5character.Withdefaultvalue14789.

PAR209RL1Dur

ThisparameterisusedtosetuphowlongRELAY1canbeactivate(inmillisecond).Withdefaultvalue
5000.

PAR210RL2Dur

ThisparameterisusedtosetuphowlongRELAY2canbeactivate(inmillisecond).Withdefaultvalue
5000.

PAR211RL1Mode

ThisparameterisusedtosetupRELAY1Mode.ModeRelay1canbesetwithdifferentcombinationof
condition(32bitbinarycode).Thedefaultvalueis50331665.

PAR212RL2Mode
ThisparameterisusedtosetupRELAY2Mode.ModeRelay2canbesetwithdifferentcombinationof
condition(32bitbinarycode).Thedefaultvalueis50331665.

PAR301F1Msg
ThisparameterisusedtosetthemessagethatwillbedisplayedontheLCDmonitorforswipeF1.
Seepar013Func.Keyasrelatedparameter.

47 Hardware Manual smart2KV3i/Bio-Optical


PAR302F2Msg

ThisparameterisusedtosetthemessagethatwillbedisplayedontheLCDmonitorforswipeF2.
Seepar013Func.Keyasrelatedparameter.

PAR303F3Msg

ThisparameterisusedtosetthemessagethatwillbedisplayedontheLCDmonitorforswipeF3.
Seepar013Func.Keyasrelatedparameter.

PAR304F4Msg

ThisparameterisusedtosetthemessagethatwillbedisplayedontheLCDmonitorforswipeF4.
Seepar013Func.Keyasrelatedparameter.

PAR305F5Msg

ThisparameterisusedtosetthemessagethatwillbedisplayedontheLCDmonitorforswipeF5.
Seepar013Func.Keyasrelatedparameter.

PAR306F6Msg

ThisparameterisusedtosetthemessagethatwillbedisplayedontheLCDmonitorforswipeF6.
Seepar013Func.Keyasrelatedparameter.

PAR307F7Msg

ThisparameterisusedtosetthemessagethatwillbedisplayedontheLCDmonitorforswipeF7.
Seepar013Func.Keyasrelatedparameter.

PAR308F8Msg

ThisparameterisusedtosetthemessagethatwillbedisplayedontheLCDmonitorforswipeF8.
Seepar013Func.Keyasrelatedparameter.

48

PAR309OpenTheDoor
ThisparameterisusedtosetupdisplaymessageOpentheDooronLCDmonitor.

PAR310OpentooLong
ThisparameterisusedtodisplaymessageOpentheDooronLCDmonitor.

PAR311ForcedDoor

ThisparameterisusedtodisplaymessageForcedDooronLCDmonitor.

PAR312Smart2KV3I
ThisparameterisusedtodisplaymessageSmart2KV3IonLCDmonitor.

PAR313AutoDirTime
Thisparameterisusedtosetupautomaticdirectiontime.