Sei sulla pagina 1di 13

Lab equipment for Electrical Installation and Workshop Laboratory

N Catego Type Specification Purpose Q


o ry tt
y
1 Weldin 1. 1
g Solder Temperature Range : 180-480C 0
ing P
Statio c
n with I/P Voltage: 190-270VAC s
Indige
nous
Heater
60W O/P Voltage : 24 VAC

Max Power : 60 -90 Watts

Time to temperature Rising

From ambient - 350C : 45 Sec.

Heater Type : Ceramic

Tip to ground Resistance : < 0.2


Ohms

Tip to ground potential : < 2mV

Auto Sleep Function : No

Temperature Lock
mode : Optional

Application: HighMass
Components & Solar PV Cells
2. 2
solde 0
r r
wire o
ll
Lab equipment for Electrical Installation and Workshop Laboratory

4 Meter 1. 1
2 digit 0
al P
Watt c
mete s
r

2. auto-polarity, auto-ranging 1
digit 0
al P
Multi c
mete s
r
Digit shall measure the electrical parameters Max voltage: 600 ac
al including current, voltage, Current input (In): On
Multi power factor, active and reactive power current transformers,
funct and frequency by means In /
ion of microprocessor technology. The 5A (secondary)
Powe meter shall be able to Measurement : - True
r communicate with PC-based Building RMS value of line
Management System via
Mete current for each phase
a common network protocol (e.g.
r and
RS232/RS485) by means of
neutral current
plugging in communication module and
without further - True RMS value of
modification of the basic unit phaseneutral voltage
for each
phase
- True RMS value of
line
voltage for each phase
- Active power, kW
Lab equipment for Electrical Installation and Workshop Laboratory

- Reactive power, kVAr


- Apparent power, kVA
- Frequency, Hz
- Power factor
- Energy, kWh
Communication
- Numeric
- Analog
Series link: RS-232 or
RS-485
Analog: 4-20 mA
output
3. 1
Tach 0
omet P
er c
s
4. 5
mete P
r c
tape s
5. Lamp test max output 3000 V Save time and reduce
Fluke peak Auto power of 20 costs by using the only
1000 minutes after non-use tester that performs all
FLT - NCV (VoltAlert) 5 essential lighting
Fluor 85 to 400 V AC tests in less than 30
esce 45 a 67 Hz seconds.
nt 10 cm (4 in) distance Lamp test: Test bulb
Light Size 21.5 cm x 3.0 cm x 6.5 cm without removing from
Teste (8.5 x 1.2 x 2.6 in) fixture
r Weight 0.37 kg (0.80 lb.) Ballast test: Easily
Battery type 4 x AA alkaline IEC determine if ballast is
LR6 working
Non-contact
voltage: Quickly
check for voltage
presence
Pin continuity
test: Tests if filaments
have continuity
Ballast-type
test: Determine if
ballast is electronic or
magnetic without
taking fixture apart
identify energy wasting
ballasts
Lab equipment for Electrical Installation and Workshop Laboratory

5. The Fluke 1623-2 earth


GEO 3- and 4-Pole Fall-of-Potential ground tester is able to
Earth (using stakes) measure earth ground loop
Groun resistances using only
d clamps. With this test
4-Pole Soil Resistivity Testing
Tester method, two clamps are
(using stakes)
placed around the earth
ground rod and each are
Selective Testing (using 1 clamp connected to the tester. No
and stakes) earth ground stakes are
used at all. A known, fixed
Stakeless Testing (using voltage is induced by one
2 clamps only) clamp and the current is
measured using the second
clamp.
5. Specified current range:30 mA to The i30 current clamp 5
Hall 30 A DC, is based P
efec 30 mA to 20 A AC rms on Hall efect c
t Output sensitivity:100 mV/A technology for use s
clam Accuracy (at +25 C): 1 % of in measurement of
p reading 2 mA both dc and
mete Resolution: 1 mA ac current. The i30
r Load impedance:> 10 k Ohms may be used
and 100 pF in conjunction with
Conductor position sensitivity: multimeters,
1 % relative to recorders and other
center reading suitable
Frequency range:DC to 20 kHz (- recording instruments
0.5 dB) for accurate
Temperature coefficient: 0.01 non-intrusive current
% of reading/C measurement.
Power supply:9 V Alkaline,
MN1604/PP3,
30 hours, low battery indicator
Working voltage
300 V ac rms or dc
Maximum conductor size:19 mm
(.748 in)
diameter
6. AA
batte
ry
7. Watt-hour meter shall have
Watt- Class 2 accuracy calibrated at
hour the normal
Mete working voltage and frequency.
r
3 Motor 1. Voltage 1
Lab equipment for Electrical Installation and Workshop Laboratory

Elect 110V/220V 0
ric Size P
12''/16''/18''
fan Frequency c
50Hz s
Power
45W
Motor size
66*14mm/66*16mm
Motor material
Copper/Aluminium
Speed setting
3 speed control

2. 1- Mains Supply : 230 V 10%, 50 Hz 5


ph Induction Motor P
AC Type : Capacitor start c
moto Phase : Single s
Current type : AC
r
Rating : 1 HP
Voltage rating : 230 V 10%
Meters Used
Voltmeter : 0-300 V
Ammeter : 0-10 A
Wattmeter : 1000 W
MCB : 10 A
3. 3- Three Phase Induction Motor 5
ph Mains Supply : Three Phase, 415V Trainer is an adaptable P
AC 10%, 50HzThree Phase Induction Motor training system for the c
moto Electrical laboratories. The s
Type : Squirrel Cage product helps you to get
r
fully acquainted with the
basic concepts and
Rating : 1HP (Also available with 2 HP,
functioning of a Three Phase
3 HP and 5 HP)
squirrel cage Induction
Motor. The trainer practically
Voltage Rating : 415V
expertises you in exercises
like Running and Reversing,
Speed : 1440 RPM (No Load) No Load Test, Block Rotor
Test, Slip Measurement,
Insulation : Class B Load Test etc.

Loading arrangement : Mechanical

Brake Drum/Pulley : Aluminum Casted

Analog Meters used

Wattmeter : 1000W (2 Nos.)

Voltmeter (MI) : 500V


Lab equipment for Electrical Installation and Workshop Laboratory

Ammeter (MI) : 5A

MCB (TPN) : 10A

Tachometer : 20,000 RPM

Dimensions (mm) : W 600 x D 350


x H 450 (Control Panel)

W 250 x D 400 x H 600 (Motor)

Weight : 14.5kg (approximate) (Control


Panel)

22kg (approximate) (Motor)

Optional

Three Phase Variac, 10A

4 Screws 1. 5
star S
head e
set t
s
2. Wera flat (slotted) extra long 5
Stan screwdriver, 0.8mm (0.03 inch) S
dard/ thick x 4mm (0.16 e
flat/ inch) wide x 300mm (11.81 inch) t
head long blade s
set
3. 5
Philip S
s e
head t
set s
4. 5
Adjus P
table c
wren s
ch(Ri
ng)
5. 3.6 volts /// 1 speed, 200
Elect rpm /// No clutch /// Work
ric
light: yes /// 11 in. long /// 16.5
cordl
oz.
Lab equipment for Electrical Installation and Workshop Laboratory

ess
scre
wdriv
er
set
5 Electro 1.
mecha Cont
nical actor
contac 2.
tors Time
and r
motor
starter
s
3.
6 Wires 1.
and Difer
cables ent
thick
ness
wires
2. (1.5 up to 185 mm2)
Cabl
es
3
Megg
er
4. Hi- Types of Measurements: used to verify electrical
pot AC/DC Selectable insulation in finished
teste Testing Method: appliances, cables or
r Automatic other wired
Measurements: AC voltage: assemblies, printed
0.055kV /current: circuit boards, electric
DC voltage: 0.056kV /current: motors,
Output Frequency:50hz and transformers.
Resistance Range:
Communications:
Digital Meter
Interfaces: GPIB(General-purpose
interface bus)
Features: Built-in Calibration,
Buzzer or Annunciator, PLC
Interface,

7 switch 1. 2
es SPST 5
2.
Lab equipment for Electrical Installation and Workshop Laboratory

two
way
switc
hes
3.
inter
medi
ate
switc
hes
4.
triple
switc
h
5. NC
and
NO
Push
butto
ns
8 CB , 1. (15-600A rating)
fuses Circu
and it
relays brea
ker
2. (15-600A rating)
fuse
3. Class 10, 20, and 30
Ther
mal
over
load
relay
9 Lightin 1.
g fluor
compo esce
nents nt
and lamp
bells 2.
incan
desc
ent
lamp
s
with
lamp
hold
Lab equipment for Electrical Installation and Workshop Laboratory

ers
3.
sodiu
m-
vapo
r
lamp
s
4.
elect
ric
bell
5.
Sock
ets
1 Cutters 1.
0 and diag
strippe onal
rs plier
2.
side
cutti
ng
nipp
ers
3.
Com
binat
ion
Pliers
(Line
man
s
Pliers
)
4.
Long
Nose
Pliers
5.
Wire
Strip
per
6.
Elect
ricia
ns
Lab equipment for Electrical Installation and Workshop Laboratory

Knife
7.
cordl
ess
Elect
ric
drill
set
8.
Hack
saw
1 supple 1.
1 mentar lighti
y ng
equip arres
ment tor
2.
joint
box
3.
work
benc
h
4.
Claw
ham
mer
5.
PVC
cond
uits
(flexi
ble
and
rigid)
6.
Pract
ice
Boar
d
8. designed to help reduce harmful
Work discharges from reaching vulnerable
Stati parts and assemblies.Part of the overall
on solution is to have a workstation
designed with the proper grounding
Safe
system to dissipate any charge away
from the productyoure producing.
9. Air
Lab equipment for Electrical Installation and Workshop Laboratory

heat
er
10. Active Diagonal Size 69''
Whit Aspect Ratio 4:3
eboa Power Supply: USB Power Supply
rd Power Consumption: 1W
Inter Writing Tools: Pen, finger,
activ pointer and any other
e objects
Infrar With full accessories
ed
69
Inch
11. Cabinet Size: Component Organiser:
Com - 400mm x 250mm x 160mm - Ideal for storing
pone Size of Drawers: electronic parts,
nt - 150mm x 75mm x35mm hardware etc
Orga - Suitable for homes
niser workshops and
- 25 factories
Draw - Comes with clear see
ers through plastic
drawers for easy
visibility of contents
- Comes with 25
Drawers, 5 Each in Row
and Column
12.
Clips
13.
Distri
butio
n
boar
d
1 Softwa 1.
2 re CAD
Elect
rical
1 PCB 1. Benchtop Guillotine type
3 PCB shearing machine to cut
Width : 300 mm (12) PCBs and Laminates.
Shea
ring Compact
structure with central handle
Mach Size : 400 mm x 350 mm
allows ease of cutting.
ine
Lab equipment for Electrical Installation and Workshop Laboratory

2.
PCB A compact tabletop High
Motor Speed : upto 20,000 speed PCB drilling machine
Drilli
R.P.M. with a Quick change Chuck
ng
Mach Drill holding by precision
ine Range : 0.6 to 3.0 mm chuck with lapped jaws

Base : MetalT Mains operated DC motor


Direct drive ( no belt and
pulley)
Working Area : 280 mm x 170
3 Step Speed Control and
mm
Illumination of work Area

Electrical Power : 230/ 50Hz,


5 A Socket required
3.
PCB Useful etching area : 250 mm
Etchi
ng x 300 mm (10 x 12)
Mach
ine Tank Capacity : 20 Liters.
Includes a heater and air flow
compressor. All construction materials
are corrosion free.

Heater : Titanum non-corrossive


with thermostat control

Timer : Provided

Electrical Power : 230/50Hz, 5A


Socket required
4.
Rolle Maximum PCB Width : 250 mm
r
Tinni ( 10)
ng
Mach Maximum PCB Thickness : 6 mm
ine
Solder Bath Capacity : 5 kgs

Heaters : 2 x 500 Watts


Lab equipment for Electrical Installation and Workshop Laboratory

Rollers : Silicon Coated

Bearings : Teflon

Electrical Power : 230V - 50 Hz,


5A Socket required

Potrebbero piacerti anche