Sei sulla pagina 1di 2

520

DEEP SEA ELECTRONICS PLC Automatic


Start

Issue 4
VH 23/10/01

DESCRIPTION

The Model 520 is an Automatic Engine Configurable inputs are available for:
Control Module designed to
automatically start and stop the engine. It Low Oil Pressure
will indicate the operational status and High Engine Temperature
fault conditions, automatically shut down Remote Start.
the engine and indicate the engine failure
by a flashing LED on the front panel. This allows the module to function with
Other simultaneous faults are indicated normally open or normally closed switches.
by steady LED. Four fully configurable auxiliary inputs are
provided to give protection expansion.
Selected operational sequences, timers These can be selected to be indication,
and alarms can be altered by the warning or shutdown inputs either
customer by using either the 807 hand immediate or held off during start up.
held calibration unit or a PC and the 808
interface. This also provides the Uncommitted LEDs allow additional
operator with real-time diagnostic annunciation. DC Supply:
facilities to monitor the operation of the 8 to 35 V Continuous.
system either locally or remotely. Multiple alarm channels are provided to
Cranking Dropouts:
Remote PC-controlled engine starting monitor the following
Able to survive 0 V for 50 mS,
and stopping is also featured. providing supply was at least 10 V
Under/Overspeed
before dropout and supply recovers
Operation of the module is via a three Charge Fail
to 5V. This is achieved without the
position rotary switch (key-switch option Emergency Stop
need for internal batteries.
available) mounted on the front panel Low oil pressure Max. Operating Current:
with STOP, AUTO and MANUAL High engine temperature
290 mA at 12 V. 210 mA at 24 V.
positions. Fail to Start Max. Standby Current:
Fail to stop
50 mA at 12 V. 30 mA at 24 V.
Microprocessor control allows for Loss of speed sensing Alternator Input Range:
enhanced operation. The module Programmable inputs as selected
15 - 300 V ac RMS
features a comprehensive list of timers Alternator Input Frequency:
and pre-configured sequences. This First up alarm is indicated by a flashing
50 - 60 Hz at rated engine speed.
allows complex specifications to be LED. Subsequent simultaneous alarms Magnetic Input Range:
achieved are displayed by a steady LED.
0.5 V to +/- 70 V (Clamped by
transient suppressors)
Configurable expansion facilities are Magnetic Input Frequency:10Hz
provided. The 500 series modules have been to 10,000 Hz
designed for front panel mounting. Start Relay Output:
Relay outputs are provided for: The module is fitted into the cut-out 16 Amp DC at supply voltage.
with the fixing clips removed. Fuel Relay Output:
Fuel Solenoid Output These are then fitted from the rear. 16 Amp DC at supply voltage.
Start Output Connection is via locking plug and Auxiliary Relay Outputs:
3 configurable outputs. socket connectors 5 Amp DC at supply voltage.
Dimensions:
Normally the relays are configured as 72 X 144 X 118.5mm (Excluding
pre-heat, load transfer and alarm outputs. switch)
However the relay function is Charge Fail / Excitation Range:
configurable to activate on a range of 32 0 V to 35 V
different functions, conditions or alarms. Operating Temperature Range:
The relays supply positive plant supply -30 to +70C
out.
CASE DIMENSIONS

1 13
72.0mm
65.5mm
14 23

111.0mm 144.0mm

Panel Cu t-o ut: 68mmx138.5mm


7.5mm

TYPICAL CONNECTIONS

NOTE:- When connected to


F a completed Panel/Gen-set
Real time diagnostic
status display is available

F F

Deep Sea Electronics plc


Highfield House, Hunmanby Industrial Estate, North Yorkshire, YO14 0PH, England
Tel: +44 (0) 1723 890099 Fax: +44 (0) 1723 893303 E-mail sales@deepseaplc.com