Sei sulla pagina 1di 3

Ultimate Design of Isolated footings and Columns

Fcu= 250 kg/cm2 for concrete


Fy= 3600 kg/cm2 for steel
working B.c= 1.5 kg/cm2 for soil
no. floors 1 floors for building

Ultimate Loads Design of columns plain footing


ultimate dia. of
column load /floor pu col. Ac bc tc As bars Lb Bb tp
no.
no. ton ton cm2 cm cm cm2 mm bars m m m
1- 15 16.5 147.82 30 30 5.4 16 4 1.6 1.6 0.4
1 120 132 1182.6 30 50 11.8 16 6 2.65 2.45 0.4
2 156 171.6 1537.4 30 70 15.4 16 8 3.1 2.75 0.4
3 185 203.5 1823.1 30 80 18.2 16 10 3.4 2.95 0.4
4 235 258.5 2315.9 30 100 23.2 16 12 3.9 3.25 0.4
Columns
Bbc Bbc
rc

tc

Lrc

Lbc

P col.

t rc

t bc
Lbc
Lrc

Reinforced concrete footing check shear


dia. of
c1 c/d j no. lsh Qsh qsh
L rc B rc t rc qc mu As bars
bars
m m m t/m2 t.m/m'-------------------- cm2 mm /m' m t/m t/m2
1 1 0.6 18.15 1.112 26 0.13 0.826 10.2 16 6 0.075 1.361 2.475
2.05 1.85 0.6 38.29 11.5 8.11 0.13 0.826 10.2 16 6 0.5 19.14 34.81
2.5 2.15 0.6 35.12 14.22 7.29 0.13 0.826 10.2 16 6 0.625 21.95 39.91
2.8 2.35 0.6 34 17 6.67 0.13 0.826 10.4 16 6 0.725 24.66 44.84
3.3 2.65 0.6 32.52 21.5 5.93 0.13 0.826 13.15 16 7 0.875 28.45 51.73
check shear check punch
check
bond
check lp bp Qp Ap qp check
stress
shear punch
m m ton m2 t/m2
Shear safe 0.85 0.85 0.408 1.87 0.2184 punch safe safe
Shear safe 1.05 0.85 38.29 2.09 18.319 punch safe safe
Shear safe 1.25 0.85 57.07 2.31 24.704 punch safe safe
Shear safe 1.35 0.85 74 2.42 30.576 punch safe safe
Shear safe 1.55 0.85 102 2.64 38.797 punch safe safe