Sei sulla pagina 1di 4

FCEVCVAV780AAN_evcvav_uk 9/09/03 14:27 Page 4

AIR CONDITIONING
EV/CV Split-System packaged units
AV Monobloc packaged units
CENTRIFUGAL FAN
Cooling only

Heat pump

Electric heating
Range
R407C
INDUSTRIAL
FCEVCVAV780AAN_evcvav_uk 9/09/03 14:26 Page 1

EV/CV Split-System packaged units


AV Monobloc packaged units
This range comprises 6 model versions
of centrifugal fan Monobloc (AV) or
EV AIR TREATMENT UNITS
Split-System (EV/CV) packaged units
for ducted air distribution.
Available in Cooling only or Heat pump
versions, with capacities ranging from
20 to 56 kW, these packaged units
corresponds perfectly to all air
conditioning and heating requirements
in medium to large sized premises.
This product range is particularly suited
for the requirements of the industrial
and tertiary sectors.

CV CONDENSER UNITS

EV/CV CENTRIFUGAL FAN UNITS HAVE BEEN DESIGNED


TO BE LOCATED ON TOP OF EACH OTHER; AN ADVANTAGE
AV MONOBLOC UNITS OFFERING OPTIMISED SPACE MANAGEMENT.

THE ENTIRE UNIT OPERATION IS CONTROLLED BY A PCB PROVIDING TOTAL OPERATING


AND MANAGEMENT CONTROL.
PRINCIPAL CHARACTERISTICS
INTELLIGENT MICROPROCESSOR CONTROL for all commercial and industrial
applications.
4 DIGIT DISPLAY - Easy access to all system status, alarm and sensor
information.
COMPRESSOR CONTROL - Optimised comfort levels via a control algorithm.
ENERGY SAVINGS - Electric heating only used when necessary (compressor
priority).
INTELLIGENT DEFROSTING - Adjusts the duration of defrosting in order
to improve comfort and optimise performance in all temperature conditions.
ALARMS JOURNAL - Memorises the last 10 alarms, even after power failure,
for easier diagnosis and maintenance.
RANDOM STARTING - Avoids simultaneous start up of several units after
an interruption in the power supply.
TEST MODE - Simple, one touch control for testing all operating modes.
ALARM OUTPUT - Dry contact for remote supervision.
FCEVCVAV780AAN_evcvav_uk 9/09/03 14:26 Page 2

Cooling only Heat pump Electric


heating

EASY ACCESS TO MAIN COMPONENTS : QUALITY EQUIPMENT :


Cooling circuit and Scroll compressor R407C refrigerant.
Fan motor 1 or two cooling circuits equipped with Scroll compressors,
Electrical cabinet and PCB depending on the model.
Scroll compressors with phase controller.
Pipe lengths up to 50 m (20 m height difference) for
EV/CV models.
Evaporator external static pressure available: up to 25 daPa.
Condenser external static pressure available: up to 15 daPa.
Variable pulley and belt fan drive.
G3 efficiency rated air filter mounted on the air
treatment unit.
OPTIONS AND ACCESSORIES
The models in this range are available with a broad selection
of accessories and options enabling made to measure air
conditioning systems to be designed.
Factory fitted Around the year.
Factory fitted High Ventilation equipment.
Electric heating.
Hardwired RCW2 wall mounted remote control.
G3 or G4 efficiency rated air filter mounted on the
Condenser Unit.
FAN MOTOR AND TRANSMISSION MOUNTED ON AN ADJUSTABLE SLIDING CHASSIS

RCW2 MODEL WALL MOUNTED


REMOTE CONTROL (ACCESSORY)
BASIC FUNCTIONS AND PROGRAMMING
Controlling up to 15 different zones (32 units) with
individual zone programming and temperature
adjustments.
Programmable 7 day thermostat
with 2 daily time periods.
Electronic Cooling / Heating
regulation.
Night time slow running.
Dehumidification.

CENTRALISED CONTROL
Easy duplication of functions for quick programming.
Master / Slave function.
Phased start up of air treatment units (multiple unit
installation).
Permanent I feel function (single installation).
THESE PACKAGED AIR CONDITIONING UNITS
ARE DESIGNED TO BE INSTALLED EXCLUSIVELY
IN A TECHNICAL SERVICES AREA.

Dimensions and weights


EV air treatment units 253 303 353 403 503 603
Weight kg 170 180 185 185 235 235
Dimensions (LxDxH) mm 1050x890x400 1050x890x650 1050x890x650 1050x890x650 2210x890x725 2210x890x725
CV condenser units
Weight kg 395 430 415 425 600 610
Dimensions (LxDxH) mm 1050x890x1300 1750x890x1550 1750x890x1550 1750x890x1550 2210x890x1775 2210x890x1775

AV air treatment units 253 303 353 403 503 603


Weight kg 568 729 804 814 835 865
AV air treatment units mm 1050x890x1800 1750x890x2200 1750x890x2200 1750x890x2200 2210x890x2450 2210x890x2450
FCEVCVAV780AAN_evcvav_uk 9/09/03 14:27 Page 3

TECHNICAL SPECIFICATIONS
EV/CV SERIES
Cooling only models 253 303 353 403 503 603
Number of circuits 1 1 2 2 2 2
Cooling capacity (1) kW 23 28 33 38 46 56
Power input kW 10 12,2 14,3 16,5 21,5 27,9
EV air treatment units
Nominal airflow m3/h 3400 6500 7000 7200 8600 9150
- Minimum/Maximum m3/h 2750/4000 5200/7500 5600/8000 5600/8300 7000/10000 7500/10500
Available external static pressure daPa 15/25 15/25 15/25 15/25 15/25 15/25
Powersound level (nominal) dB(A) 76 77 78 78 80 80
CV condenser units
Nominal airflow m3/h 6600 10900 13500 13500 210000 23000
- Minimum/Maximum m3/h 6100/7100 9800/11000 12100/14800 12100/14800 19500/22500 21500/24500
Available external static pressure daPa 15 15 15 15 15 15
Powersound level (nominal) dB(A) 78 80 81 81 84 84
Compressor type Scroll Scroll Scroll Scroll Scroll Scroll
Power supply 3N~400V - 50Hz

- Printed in U.E.
Fuse rating am (3N~400V) A 25 32 40 40 63 63
Maximum current A 23,3 28 36 38 50 58,3
EV/CV RC SERIES
Heat pump models 253 RC 303 RC 353 RC 403 RC 503 RC 603 RC
Number of circuits 1 1 2 2 2 2
Heating capacity (2) kW 25 30 35 40 46 56
Power input kW 9,7 11,8 13,7 15,8 20,8 26
Cooling capacity (1) kW 23 28 33 38 46 56
Power input kW 10 12,2 14,3 16,5 21,5 27,9
Connections characteristics between units
Refrigerating pipe lengths (not supplied)
- Basic equipment

REF : FC EV/CV-AV 780A/AN ACE MARKETING - RCS VERSAILLES B 421 305 996 - Specifications subject to change without notice - Pictures non contractual -
Basic maximum length m 30 30 30 30 30 30
Maximum height difference (CV above EV) m 25 25 25 25 25 25
Maximum height difference (EV above CV) 15 15 15 15 15 15
Gas pipe diameter (union) Inchs 13/8 13/8 7/8 7/8 13/8 13/8
Liquid pipe diameter Inchs 5/8 5/8 1/2 1/2 5/8 5/8
- Longer length options
Length m 50 50 50 50 50 50
Gas pipe diameter Inchs 13/8 13/8 7/8 7/8 15/8 1 " 5/8
Liquid pipe diameter Inchs 5/8 5/8 1/2 1/2 5/8 5/8
Maximum height difference m 15 15 15 15 15 15
Condensate drainage Inchs 1 1 1 1 1 1
Electrical connections (not supplied)
3N~ 400 V version mm2 4x1,5 4x1,5 4x1,5 4x1,5 4x1,5 4x1,5
NOTES: All values are specified for a 3N~400 V 50 Hz supply voltage. (1) Nominal cooling capacity: International conditions: (NF EN 255.2 - NF EN 814.2 standards) - 27C / 19C (wet bulb) - Outside air temperature 35C / 24C (wet
bulb)). (2) Nominal heating capacity: International conditions: 20C / 12C (wet bulb) - Outside air temperature 7C / 6C (wet bulb).

AV SERIES
Cooling only models 253 303 353 403 503 603
Number of circuits 1 1 2 2 2 2
Cooling capacity (1) kW 23 28 33 38 46 56
Power input kW 10 12,2 14,3 16,5 21,5 27,9
Air treatment
Nominal airflow m3/h 3400 6500 7000 7200 8600 9150
- Minimum/Maximum m3/h 2750/4000 5200/7500 5600/8000 5600/8300 7000/10000 7500/10500
Available external static pressure daPa 15/25 15/25 15/25 15/25 15/25 15/25
Powersound level (nominal) dB(A) 76 77 78 78 80 80
Condensing
Nominal airflow m3/h 6600 10900 13500 13500 210000 23000
- Minimum/Maximum m3/h 6100/7100 9800/11000 12100/14800 12100/14800 19500/22500 21500/24500
Available external static pressure daPa 15 15 15 15 15 15
Powersound level (nominal) dB(A) 78 80 81 81 84 84
Compressor type Scroll Scroll Scroll Scroll Scroll Scroll
Fuse rating am (3N~400 V) A 25 32 40 40 63 63
Power supply 3N~400V - 50Hz
Fuse rating am (3N~400 V) A 25 32 40 40 63 63
Maximum current A 23,3 28 36 38 50 58,3
AV RC SERIES
Heat pump models 253 RC 303 RC 353 RC 403 RC 503 RC 603 RC RC
Number of circuits 1 1 2 2 2 2
Heating capacity (2) kW 25 30 35 40 46 56
Power input kW 9,7 11,8 13,7 15,8 20,8 26
Cooling capacity (1) kW 23 28 33 38 46 56
Power input kW 10 12,2 14,3 16,5 21,5 27,9
NOTES: All values are specified for a 3N~400 V 50 Hz supply voltage. (1) Nominal cooling capacity: International conditions: (NF EN 255.2 - NF EN 814.2 standards) - 27C / 19C (wet bulb) - Outside air temperature 35C / 24C (wet
bulb)). (2) Nominal heating capacity: International conditions: 20C / 12C (wet bulb) - Outside air temperature 7C / 6C (wet bulb).

Your distributor

Potrebbero piacerti anche