Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
rxbli:mo=rxotrx-395-5; (Block)
rxtei:mo=rxotrx-395-5; (Perf. Test)
rxble:mo=rxotrx-395-5; (Deblock)
rxmfp:mo=rxotrx-395-5;
rxmsp:mo=rxotrx-395-5,subord;
Note: State, BLO, BLA all the values will be zero for active TRX (TRX in good condition)
rxtcp:moty=rxotg , cell=dx03214;
allip:alcat=bts;
allip:alcat=sw_dev;
rxbli:mo=rxotrx-23-0,subord; (Block)
rxese:mo=rxotrx-23-0,subord; (Reload Order)
rxesi:mo=rxotrx-23-0,subord; (Reload Execute)
rxble:mo=rxotrx-23-0,subord;(Deblock)
11. TRX no. of 900B and 1800B
1 2 3 1 2 3 (No. of Cell)
0 4 8 0 4 8 |
1 5 9 1 5 9 |
2 6 10 2 6 10 | (No.
3 7 11 3 7 11
Note: Searching format to find out the Fault description, Action from the PDF file: No of class: fault
code. Example: 1B:33, 2A:30
rrgbp;
rxbli:mo=rxotrx-23-0,subord; (Lock)
rxble:mo=rxotrx-23-0,subord; (Unlock)
rxbli:mo=rxotrx-23-0; (Lock)
rxble:mo=rxotrx-23-0; (Unlock)
17. To check the RBL2 of a site either it is Working or not (Loop check)
dtstp:dip=84rtltb;
dtstp:dip=84rtltt;
caclp;
21.To find the number of traffic channel of a site
c7ltp:ls=all;
dtqsr:dip=all,es;
dtqsr:dip=all,cs2;
dtqsr:dip=all,ses;
dtqsr:dip=all,ses2;
dtqsr:dip=all,sf;
24. To look into either a cell holding call or to see channel status
rlcrp:cell=dx00932;
c7spp:sp=all;
rldep:cell=dx00931;
Lj-l
30. The command to point the connected BSCs for the TRC
rrbsp;
31. The command of getting the name of MSC to which BSC is connected
rrmbp;
rrmbp:msc=all;
dtstp:dip=all;
34. To see either a cell is halted or active
rlstp:cell=dx00931;
rlstp:cell=all,state=halted;
rxapp:mo=rxotg-6;
Here 6 is the TG value of the site. If no. of TCH starts from 1 to 31 then 2E1. If starts from 1 to 15
then it will be 1E1 carrying site .
dtstp:dip=all,state=abl;
rxasp:mo=rxotrx-260-0;
rxmop:mo=rxocf-8;
1. dtble:dip=78rblt2; (Unblock)
2. dtbli:dip=78rblt2; (block)
rxasp:mo=rxotg-340;
rxmop:mo=rxotg-8;
rxmfp:mo=rxotrx-8-0;
If RU Version, Position all values show zero then the TRX is without hardware.
45. To check if AP is up
1) aploc;
2) prcstate l
AP is equivalent to BAM. APs are redundant.
Elaboration:
Note:
For CDU-G : If TG value is less than 200 then it is 900B else 1800B
For CDU-K : Both bands will have same TG
Sometimes 1800B and 900B are thrown over 1E1 in that case RBLT2 of Both will be same but their
TG value will be different.
If OML fault appears against a TRX or site that means OMC connection is broken for that site or
TRX. So no command will be successful in that case.
BTS
!
!------RBLT2
!
BSC
!------RTLTB/RTB/RTB2
!
!------RTLTT/RTT
TRC
!
!------RAL2/RALT2
!
MSC
RAL2/RALT2 equivalent to PCMA
RTLTT/RTT2 equivalent to PCMS
RBL2/RBLT2 equivalent to PCMB
49.To Find out how many ckt are block of a STM( for this command please connected to respective
switch )
Stdsp:dety=rtltt2,bsc=all;
50, To see the trx band(900/1800) here 289 TG value,2b TRX number
RXMOP:MO=RXOTRX-289-2,subord;
Calculation: NBL/NDV
RXMSP:MO = RXOTG-##,SUBORD;
RXESI:MO = RXOTRX-##-##,SUBORD;
RXBLE:MO = RXOTRX-##-##,SUBORD;
54,
Rrgbp;