Sei sulla pagina 1di 94

Production & Economics

R2003.14
Global Release Notes

Contents

Introduction ................................................................................................................................. 2
Documentation for Release 2003.14 ........................................................................................... 4
System Requirements ................................................................................................................. 5
Before You Install ....................................................................................................................... 15
Installation .................................................................................................................................. 24
Licensing ..................................................................................................................................... 25
EDM Roles for ARIES, DSS, and Desktop Navigator ............................................................... 27
Enhancements and New Functionality ....................................................................................... 32
Problems Fixed ........................................................................................................................... 44
Known Problems ......................................................................................................................... 54
Running Production & Economics Applications ........................................................................ 60
Contacting Support ..................................................................................................................... 61
Appendix A: Roles and Privileges .............................................................................................. 66

June 2005 Part No. 162973 R2003.14


Landmark Production & Economics R2003.14 Global Release Notes

Introduction
Welcome to Landmark Graphics Corporations Windows-based Engineers Desktop R2003.14
release. This release of Landmarks Engineers Data Model (EDM) provides support to Drilling
applications and Production & Economics applications on a shared data model. Drilling
applicationsWell Engineering, Tubular Design, and Drilling Data Managementare integrated
on the shared data model. Additionally, for this release Production & Economics applications
Active Field Surveillance, Production Surveillance, Production Allocation and Data Management,
Deterministic Economics, International Economics, & Reserves Management, and Edinburgh
Petroleum Services (EPS) well engineering toolsare also integrated on the shared EDM data
model. Integration and providing natural workflows for engineering, production, and economics
are primary strategies of Landmark. The EDM platform has been developed to address these needs
in the Drilling & Well Services and Production & Economics areas.

This release of Engineers Desktop is focused on the following applications:

Engineers Data ModelAdministration Utility, EDM MSDE Administration, Drilling Data


Migration, and Production/Economics Data Migration, (R2003.14 CD, volume 5).

Drilling EngineeringCasingSeat, COMPASS, Data Analyzer, OpenWells, PROFILE,


StressCheck, WELLPLAN, (R2003.14 CD, volume 6).

Production & Economics ARIES, ARIES International, Desktop Navigator, DSS, TOW/cs,
and Edinburgh Petroleum Services (EPS), (R2003.14 CD, volume 15).

Later releases of EDM will add Pore and Fracture Pressure modeling and advanced Well Cost
Estimating, Well Planning, and Rig Scheduling capabilities.

EDT 2003.14 P & E Global Release Notes Page 2 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Engineers Desktop Release 2003.14 setup is a single installation program that enables you to
install all of the products from the EDM release from several CDs (Volumes 5, 6, and 15). The setup
program begins automatically when CD 5 is inserted into your CD-ROM drive. For detailed
installation instructions please review the EDT Installation Guide provided with this release.

IMPORTANT: Documentation available on CD Volume 5, 6, & 15

The following documents are provided in hardcopy with the release media:

Planning the Installation (EDT_PlanningInstall.pdf)


EDM Release Notes (EDM_Install.pdf)
EDT Drilling Summary Release Notes (EDT_Drilling_SummaryReleaseNotes.pdf)
EDT Production and Economics Global Release Notes (PE_ReleaseNotes.pdf)

Planning the Installation, EDT on Citrix, and EDM Release Notes are available on CD Volume 5 (in
Products\EDM\Docs).

The EDT Drilling Summary Release Notes are on CD volume 6 (in Products\DrillComp\Docs).

The EDT Production and Economics Global Release Notes are on CD Volume 15 (in Products\ProdEcon\Docs)

The following sections of this document details the following information about:

The EDM release and the enhancements provided with 2003.14.

The ARIES, DSS, TOW/cs & Desktop Navigator applications.

The Fixed defects for ARIES, DSS, TOW/cs, & Desktop Navigator.

Known Issues for ARIES, DSS, TOW/cs, & Desktop Navigator.

Contact your Landmark Sales or Support Representative for further information on upcoming
EDM release plans.

EDT 2003.14 P & E Global Release Notes Page 3 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Documentation for Release 2003.14


This 2003.14 version of the Production and Economics Global Release Notes contains release
notes for the Production and Economics applications, ARIES, ARIES International, Desktop
Navigator, DSS, and TOW/cs.

During installation of the 2003.14 EDT Production and Economics applications, online help is
installed for ARIES, ARIES International, Desktop Navigator, DSS, and TOW/cs.

The EDT Production and Economics 2003.14 release includes the following online documentation
in *.pdf format:

Planning the Installation this guide contains the installation steps for installing EDM and
the Engineers Desktop applications, as well as referencing the documentation needed to install
EDM, the EDT Drilling and Completions Installation, and the EDT Production and Economics
Installation. The file is named EDT_PlanningInstall.pdf.

EDT Production & Economics Global Release Notes This guide contains the high-level
release notes for the EDT Production and Economics release, as well as overviews, defect
fixes, enhancements, and known issues for ARIES, ARIES International, Desktop Navigator,
DSS, and TOW/cs. The file is named PE_ReleaseNotes.pdf.

EDT Production and Economics Installation Guide this guide contains the installation
procedures for installing the Production and Economic applications, ARIES, ARIES
International, Desktop Navigator, DSS, & TOW/cs. The file is named EDT_PE_Install.pdf.

EDT Production and Economics Database & Migration Guide this guide explains how to
migrate legacy data from TOW/cs and ARIES into the EDM database. The guide also explains
how to install, configure, and manage your EDM Oracle, Microsoft SQL Server, or MSDE
database, and includes configuration, SQL scripts, preparation of the server, and so forth. The
file is named EDT_PE_Database_&_Migration.pdf.

LAM 2003.0Windows Release Notes these notes explain the procedures for installing,
configuring, and managing the license system for Landmark applications. Directions are also
given for uninstalling older versions of the FLEXlm license server. The file is named
LAMReleaseNotes.pdf and is located in the Products\EDT\Install\LAM folder on the
Volume 5 CD.

You will also receive a Landmark OpenBooks CD. This CD contains all available documentation
for Landmark Products.

EDT 2003.14 P & E Global Release Notes Page 4 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

System Requirements
Network Clients or Standalone

Recommended Minimum

Windows XP Professional, SP 2 or Windows XP Professional, SP 2 or


Windows 2000 Professional, SP 4 Windows 2000 Professional, SP 4
2 GHz processor 300 MHz processor
1 GB RAM or greater 256 MB RAM or greater
VGA Color Monitor VGA Color Monitor
106-key Windows-ready integrated keyboard 106-key Windows-ready integrated keyboard
MS-compatible mouse or pointing device MS-compatible mouse or pointing device
TCP/IP-based network connection 100 Mbps, TCP/IP-based network connection 100 Mbps,
or or
FLEXid dongle (bitlock), FLEXlm version 7.2i (for FLEXid dongle (bitlock), FLEXlm version 7.2i (for
licensing) licensing)

3 GB or better disk space 2.1GB disk space (with everything installed)


CD-ROM drive (not required if installing from CD-ROM drive (not required if installing from
a network location) a network location)
For Standalone systems, should have For Standalone systems, should have
parallel port or USB port if dongle/bitlock parallel port or USB port if dongle/bitlock
license used. license used.

Servers

Recommended Minimum

Windows 2000 Professional Server, SP 4 Windows 2000 Professional Workstation,


SP 4
2 GHz or higher 600 MHz processor
1 GB RAM or greater 512 MB RAM or greater
VGA Color Monitor VGA Color Monitor
106-key Windows-ready integrated keyboard 106-key Windows-ready integrated keyboard
MS-compatible mouse or pointing device MS-compatible mouse or pointing device
TCP/IP-based network connection 100 Mbps TCP/IP-based network connection 10 Mbps
2-4 GB or better disk space 2 GB disk space
CD-ROM drive (not required if installing from CD-ROM drive (not required if installing from
a network location) a network location)

EDT 2003.14 P & E Global Release Notes Page 5 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Recommended Minimum

Windows 2003 Server Windows 2003 Server


2 GHz or higher 600 MHz processor
2 GB RAM or greater 1 GB RAM or greater
VGA Color Monitor VGA Color Monitor
106-key Windows-ready integrated keyboard 106-key Windows-ready integrated keyboard
MS-compatible mouse or pointing device MS-compatible mouse or pointing device
TCP/IP-based network connection 100 Mbps TCP/IP-based network connection 10 Mbps
2-4 GB or better disk space 2 GB disk space
CD-ROM drive (not required if installing from CD-ROM drive (not required if installing from
a network location) a network location)

OpenWorks Clients

Recommended Minimum

Windows 2000 Server Windows 2000 Server


500 MHz Intel Pentium processor 350 MHz Intel Pentium III processor
2 GB RAM or greater 512 MB RAM or greater
VGA Color Monitor VGA Color Monitor
101 AT-style Windows-ready integrated 101 AT-style Windows-ready integrated
keyboard keyboard
MS-compatible mouse or pointing device MS-compatible mouse or pointing device
TCP/IP-based network connection 100 Mbps TCP/IP-based network connection 100 Mbps
3 GB or better SCSI disk space 3 GB SCSI disk space
1.44 MB, 3.5 floppy drive 1.44 MB, 3.5 floppy drive
CD-ROM drive CD-ROM drive

OpenWorks Servers

Recommended Minimum

Windows 2000 Server Windows 2000 Server


800 MHz Intel Pentium processor 350 MHz Intel Pentium III processor
2 GB RAM or greater 512 MB RAM or greater
VGA Color Monitor VGA Color Monitor

EDT 2003.14 P & E Global Release Notes Page 6 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Recommended Minimum

101 AT-style Windows-ready integrated 101 AT-style Windows-ready integrated


keyboard keyboard
MS-compatible mouse or pointing device MS-compatible mouse or pointing device
TCP/IP-based network connection 100 Mbps TCP/IP-based network connection 100 Mbps
4 GB or better SCSI disk space 3 GB SCSI disk space
1.44 MB, 3.5 floppy drive 1.44 MB, 3.5 floppy drive
CD-ROM drive CD-ROM drive

Citrix

The 2003.14 Engineers Desktop applications were also tested in a Citrix environment. The test
environment consisted of three server-class PCs:

Server 1 (Database server, SAM server)


Operating System: Windows 2003 Server Enterprise
Services: SQL Server 2000 Enterprise
Oracle 9i
EDM database
(SAM Simultaneous Access Monitor (Note that the SAM server cannot be on the
same server with Citrix and the published applications)
Server 2 (Citrix and Applications)
Operating System: Windows 2003 Server Standard
Services: Citrix Presentation Server 3.0
Citrix Resource Manager
Citrix License Server components
NFuse Elite
Server 3 (Citrix and Applications)
Operating System: Windows 2003 Server Standard
Services: Citrix Presentation Server 3.0
Citrix Resource Manager

EDT 2003.14 P & E Global Release Notes Page 7 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Citrix Servers (Tested Configuration)


Windows 2003 Server Standard Edition
2 x 933 MHz Intel Pentium III processors
2 GB RAM
TCP/IP-based network connection 100 Mbps (both NICs)
12 GB disk space

Note: Citrix can be configured in a number of different ways. Landmark supports only the
configuration outlined above.

For more details regarding Citrix, refer to the Citrix Guide (EDT_Citrix.pdf), located on CD
Volume 5.

EDT 2003.14 P & E Global Release Notes Page 8 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Space Requirements for Individual Applications and Tools

The table below shows the minimum disk space requirements for various installation combinations:

Applications Approximate Disk Space Needed to Install


EDM 780 MB
Engineers Data Model
(Required support files will be copied into the Windows
installation directory; the installation of EDM and MSDE
support and temporary installation files requires 400 MB
of disk space)
Drilling & Completions 280 MB
Drilling Engineering (CasingSeat, COMPASS,
StressCheck, WELLPLAN)

Drilling & Completions 250 MB


Data Management (Data Analyzer, OpenWells,
OpenWells Regulatory Reports, PROFILE)

Production and Economics 100 MB


ARIES Family

Production and Economics 85 MB


DSS

Production and Economics 225 MB


TOWcs

Production and Economics 160 MB


Desktop Navigator

Production and Economics 50 MB


OpenWire Production

TOTAL: Everything ~2 GB

ODBC Drivers

ODBC Driver Name Version Supported

Microsoft SQL Server 2000 2000.81.9042.00 Supported

Oracle 8.1.7 ODBC Driver 8.01.07.00 No longer supported

Oracle 9i ODBC Driver 9.02.00.65 Supported

Oracle 10g ODBC Driver 10.01.00.31 Supported

EDT 2003.14 P & E Global Release Notes Page 9 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Note: OpenWorks will now work with Oracle 9i, so if you need to integrate EDM applications with
OpenWorks, you will have to use Oracle 9i. EDM on Oracle 8.1.7 is no longer supported.

Configuration Combinations For Engineers Desktop, DecisionSpace,


and OpenWorks

Applications
Engineers DecisionSpace Engineers DecisionSpace DecisionSpace
Desktop R2003.10.0.7, Desktop R2003.10.0.7/ R2003.10.0.7/
R2003.14, on on Oracle 9i R2003.14, OpenWorks OpenWorks
Oracle 9i or on MSDE R2003.12, R2003.12, on
10g on Oracle 8.1.7 Oracle 9i
Windows yes; see 5 yes yes yes; see 1 yes; see 1
2000 below below below
Professional
Windows yes; see 5 yes yes yes; see 1 yes; see 1
Operating System

2000 Server below below below

Windows XP not tested; see 5 yes yes see 1 and 4 see 1 and 4
Professional below below below

Windows yes; see 5 untested yes untested untested


2003 Server below

1
DecisionSpace only supports Oracle 8.1.7 client, but it will support an Oracle 9i database.
2 If you want to run Engineers Desktop R2003.14 and DecisionSpace R2003.10.0.7 on the same standalone
workstation, you MUST run on Windows 2000.
3
If you want to run Engineers Desktop R2003.14 and DecisionSpace R2003.10.0.7 on an XP workstation,
then they MUST connect to an OpenWorks instance on another workstation.
4 Oracle 8.1.7 Client is not officially supported by Oracle on any platform above Windows 2000. You may
need to perform some special installation operations to enable this driver on this platform. See the instal-
lation instructions included with either DecisionSpace and/or OpenWorks for more information.
5
Oracle10g is not supported for Drilling applications.

EDT 2003.14 P & E Global Release Notes Page 10 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Operating System and Third Party Upgrades

The following table describes the operating systems (OS) and third party software upgrades supported for
applications in Release2003.14.

Product/Package Microsoft Windows Windows XP Profes-


2000 sional and Microsoft
Windows Server 2003
Certified OS Windows 2000 Professional, Windows XP Professional,
SP 4 SP 2
Adobe Systems Inc., Adobe Reader 6.0 6.0

Adobe Systems Inc., Adobe Acrobat 6.0 (TOW/cs only) 6.0 (TOW/cs only)

Apache/XML Xerces 14.0 14.0


Blue Marble Carto 5.0.0.31 5.0.0.31
Commons BeanUtils 1.4.1 1.4.1
Commons Collections 2.0 2.0
Commons Logging 1.0.2 1.0.2
ComponentOne LLC Chart 7.0 7.0
ComponentOne LLC TrueDBGrid Pro 7.0b 7.0b
Crystal Reports Runtime 9.2 9.2
Data Dynamics, Ltd., ActiveBar Pro 2.0 (TOW/cs only) 2.0 (TOW/cs only)
Decisioneering, Inc. Crystal Ball Crystal Ball 2000 Standard Crystal Ball 2000 Standard
Desaware Inc., SpyWorks 6.3 Professional 6.3 Professional 6.3 Professional
DEX 3.61 3.61
DirectX 9.0c 9.0c
FarPoint Technologies Inc., Spread 7.0 7.0
FarPoint Technologies Inc., FarPoint 3.1.1.0 3.1.1.0
Technologies TabPro
Hewlett-Packard Development Company, L.P., 6.1a; 6,5 (ARIES only) 6.1a; 6.5 (ARIES only)
Compaq Visual Fortran
Hummingbird Ltd., Exceed/Exceed 3D 7.0 (VIP Desktop 2003) ----
7.1 (VIP Desktop 2003)
Infragistics Corp., Active Threed Plus 3.0.1.10 3.0.1.10

EDT 2003.14 P & E Global Release Notes Page 11 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Product/Package Microsoft Windows Windows XP Profes-


2000 sional and Microsoft
Windows Server 2003
Infragistics Corp., Active Toolbars 1.0.0.35 1.0.0.35
Infragistics Corp., Active ListBar 1.0.0.24 1.0.0.24
Infragistics Corp., Active TreeView 1.0.2.8 1.0.2.8
Infragistics Corp., Data Widgets 3.1 3.1
Infragistics Corp., Calendar Widgets 1.1 1.1
Infragistics Corp., NetAdvantage 2004, Vol. 3 2004, Vol. 3
Infragistics Corp., UltraToolBars 4.01 4.01
Inner Media Inc., DynaZip 4.0.0 4.0.0
INT 3.4 3.4
Mabry Software Inc., FTP/X Control 5.0.0.12 5.0.0.12
Macrovision Corporation Flexlm 7.2i 7.2i
Macrovision InstallShield Admin Studio 6.0 6.0
Microsoft Internet Explorer 6.0 6.0
Microsoft JET 4.0 SP8 4.0 SP8
Microsoft Data Access Components (MDAC) 2.70.9001 2.8 SP1
Microsoft Office 2003 SP1 SP1
Microsoft Office 2000 (Microsoft Access, SP2 SP1
Microsoft Excel)
Microsoft XP Professional (Microsoft ---- SP2
Access, Microsoft Excel)
Microsoft SQL Server Desktop Engine 2.0 SP3A 2.0 SP3A
(MSDE)
Microsoft SQL Server 2000 SP3 2000 SP3
Microsoft.NET Framework 1.1 1.1.4322, SP1 1.1.4322. SP1
Microsoft Visual Studio 6 SP6 SP6
Microsoft Visual Studio 7 (.NET) 1.0 1.0
MKS Inc., NuTCRACKER 4.2a 4.2a
OPC Foundation SDK 2.00 2.00
Oracle Corporation, ORACLE Client 9i/10g (10g not supported for 9i/10g (10g not supported for
Drilling) Drilling)
Oracle Corporation, ORACLE Server 9i/10g (10g not supported for 9i/10g (10g not supported for
Drilling) Drilling)
PaTENT MPI Dev Kit 4.0.15 4.0.15

EDT 2003.14 P & E Global Release Notes Page 12 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Product/Package Microsoft Windows Windows XP Profes-


2000 sional and Microsoft
Windows Server 2003
PaTENT MPI Runtime 4.0.15 4.0.15
Rawtech List Collection LC3 3.0 3.0
Rogue Wave 6.0.4 6.0.4
Rogue Wave Software, Inc., Stingray Studio 8.11 8.11
Objective Grid PRO
Rogue Wave Software, Inc., Stingray Studio 8.03 8.03
Objective Grid Standard
Rogue Wave Software, Inc., Stingray Studio 8.03 8.03
Objective Toolkit Standard
SCGrid.com, SCGrid Active X grid Control 4.5.0.3 4.5.0.3
SDI 5.3 ----
Silicon Graphics, Inc. OpenGL 1.2 1.2
Softel vdm, Inc., Sft Tree/DLL 4.5 4.5
Software FX, Inc., Chart FX Active X 3.0.35.0 3.0.35.0
Control
Software FX, Inc., Chart FX .NET Control 6.2 6.2
Sun Microsystems Inc., Java 2 Runtime 1.4.1_05-B01 1.4.1_05-B01
Environment, Standard Edition
sysFire LLC, GreenLeaf Software 2.13 2.13
ArchiveLib
TCL Library (Tclib) 8.2.3 8.2.3

Screen Resolutions

Recommended Minimum

1024 x 768 or higher 1024 x 768

Note: If you experience display problems when running PROFILE, PROFILE Symbol Manager, or graphs
in WELLPLAN Critical Speed module, upgrade your video driver to the latest version.

EDT 2003.14 P & E Global Release Notes Page 13 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Other Requirements

Applications require that Landmark LAM or a FLEXlm bitlock be installed for licensing purposes. FLEX
dongle bitlocks are not supported on a Server installation
Applications require Microsoft Data Access Components (MDAC) version 2.7 or higher. The Setup
Program will automatically install MDAC 2.7 if necessary.
The TOW/cs SCADA application supports only version 6.x of Visual Systems CygNet using the
TCP/IP protocol.
For Windows XP Professional users, all Critical and Recommended Updates from Windows Update
should be installed.
Internet Explorer 6.0 is needed for the installation.
Oracle users must use either Oracle 9i or 10g client. (10g cannot be used for Drilling).

EDM Install Shield and MSDE Install Requirements

The Engineers Desktop installation always copies required support files into the Windows instal-
lation directory. This is in addition to disk space required for the EDM program files, which go
into a separate directory. The installation of EDM and MSDE support files requires approximately
30 MB of disk space for files, as well as an additional 50 MB for temporary files created by the
installation.

EDT 2003.14 P & E Global Release Notes Page 14 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Before You Install


Before installing Engineers Desktop 2003.14, review these release notes entirely. The release
notes give you necessary information about:
the Production and Economics applications in Engineers Desktop R2003.14.

the hardware and operating systems on which you can run Engineers Desktop R2003.14

product dependencies

New features, fixed defects, and known problems for individual production and economics prod-
ucts are included in the document and listed on page 32.

Installation Checklist

The applications found in Engineers Desktop 2003.14 require a certain order of installation. The
following checklist outlines the phases of the installation process.

1. If you wish to upgrade your EDM 2003.5 database to the 2003.14 version, make sure that you
have applied the latest patch (2003.5.0.4) to EDM 2003.5 BEFORE proceeding with the
2003.14 installation! For information on the patch, contact Landmark Support.

2. Upgrade the Operating System, if necessary. For Windows 2000, Service Pack 4 must be
installed for use with FLEXlm LAM Client/Server. For Windows XP, Service Release 1 must
be installed.

3. Install Oracle (if you use Oracle).

4. Patch Oracle (if you use Oracle).

5. Before installing products you must load Adobe Acrobat Reader (available on CD Volume 2)
to read the available documentation.

6. Uninstall any existing FLEXlm license servers (LAM servers) older than R2003.0 (FLEXlm
version 7.2e). See LAM 2003.0Windows Release Notes (LAMReleaseNotes.pdf), located in
the Products\EDT\Install\LAM folder on CD 5, for details.

7. Install individual products (available on CD Volumes 5, 6, and 15).

8. Install the 2003 LAM server (FLEXlm version 7.2e) and obtain product licenses. See LAM
2003.0Windows Release Notes (LAMReleaseNotes.pdf), located in the
Products\EDT\Install\\LAM folder on CD 5, for details.

EDT 2003.14 P & E Global Release Notes Page 15 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

9. Upgrade existing EDM 2003.11.0.3 databases to 2003.14. See the EDT Drilling Database
Guide, the EDT Drilling Migration Guide, or the EDT Production and Economics Database
& Migration Guide for details.

10. If you dont have an existing EDM database and want to create one on Oracle, see the EDT
Drilling Database Guide or the EDT Production and Economics Database & Migration
Guide for details.

11. Migrate any existing pre-2003.11 databases to 2003.14. For Drilling applications, see the EDT
Drilling Migration Guide for details; for Production & Economics applications, see the EDT
Production and Economics Database & Migration Guide for details.

12. If you want to install EPS (Edinburgh Petroleum Services) well engineering tools (WellFlo
and PanEDM), install them now by running the executables from CD 15s \Petroleum
Engineering Utilities folder.

MSDE Install Behavior with SQL Server Client/SQL Server

Microsoft Desktop Engine or MSDE is the standalone database provided with the Engineers
Desktop R2003.14 release. MSDE is a new technology that provides local data storage compati-
ble with Microsoft SQL Server 2000. It is designed and optimized for use on smaller computer
systems, such as a single-user computer or a small workgroup server.
Microsofts utility for installing MSDE is included within the Landmark Engineers Desktop
2003.14 install program. The behavior of the MSDE install on a PC is different if the PC already
has Microsoft SQL Server Client installed or SQL Server itself. Landmark has no control over
this MSDE install behavior, as these are Microsofts own installation tools.
Complete documentation of this behavior and recommended installation procedures for the three
different installations found in R2003.14 are provided in Landmarks EDM_Install.pdf,
EDT_Drilling_Install.pdf, and EDT_PE_Install.pdf. These instructions enable a client to success-
fully install Engineers Desktop and MSDE without affecting existing SQL Server Client applica-
tions. It is important that clients using Microsoft SQL Server Client or SQL Server review the
installation notes thoroughly before attempting to install Engineers Desktop 2003.14.

EDT 2003.14 P & E Global Release Notes Page 16 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Contents of the Engineers Desktop 2003.14 Release

Engineers Desktop 2003.14 is contained on the following volumes:


Volume 5 Engineers Data Model (EDM)

Volume 6 Drilling Engineering

Volume 15 Production and Economics and third-party applications


from Edinburgh Petroleum Services (EPS)

The Engineers Desktop 2003.14 Release includes the following applications and tools:

Acrobat Reader 6.0

Acrobat Reader is needed to view the release notes and other documentation in *.PDF format. If
you already have this version of the Reader installed, you do not need to
re-install it. The application is available on CD Volume 2.

Planning the Installation

This guide outlines the necessary installation and data migration steps for the Engineers Desktop
R2003.14. The file for this document is labeled EDT_PlanningInstall.pdf.

Please note

R2003.14 contains three installation categories:

Engineers Data Model (EDM)


Drilling and Completions applications
Production and Economics applications

EDM Release Notes

The EDM Release Notes will contain information on the Engineers Data Model, including a list
of new tables and known issues. The file for this document is labeled EDM_ReleaseNotes.pdf.

EDM Installation Guide

The EDM Installation Guide explains the process of setting up a new EDM database or migrating
an old database to this new method of storing data and working with integrated applications. The
file for this guide is labeled EDM_Install.pdf.

EDT 2003.14 P & E Global Release Notes Page 17 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

EDT Drilling Summary Level Release Notes

The EDT Drilling Summary Level Release Notes contains highlevel documentation for the
Drilling and Completions portion of Engineers Desktop R2003.14. The file for this document is
labeled EDT_Drilling_SummaryReleaseNotes.pdf.

EDT Drilling Installation Guide

The EDT Drilling Installation Guide explains the process of installing Landmarks Drilling &
Completions applications. This file is labeled EDT_Drilling_Install.pdf. EDT Production and
Economics Global Release Notes, this document.

EDT Production & Economics Installation Guide

The EDT Production & Economics Installation Guide explains the process of installing Land-
marks Production and Economics applications. This file is labeled EDT_PE_Install.pdf.

Install Shield

The Install Shield that is displayed during installation will install the selected
applications.

Engineers Data Model

Selecting Engineers Data Model installs the following applications:

EDM Database
EDM Administration Utility
MSDE Administration Utility
Drilling Data Migration
Production and Economics Data Migration

EDM Database

EDM (Engineers Data Model) is Landmarks newest integrated database product. This release
of Engineers Desktop 2003.14 enables the migration of legacy data from COMPASS,
WELLPLAN, DIMS, TOWcs, and ARIES applications into the new common database.
CasingSeat and StressCheck can directly import legacy data files. Common data from each
legacy database can be merged into one set of shared business objects, preventing future
duplication of information.

The EDM database allows for centralization of Drilling application data sets and Production &
Economics application data sets, and enables naturally integrated engineering workflows. For

EDT 2003.14 P & E Global Release Notes Page 18 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

this release, integrated workflows are available for Drilling applications, Production &
Economics applications, and l cross-domain workflows between the Production and Drilling
applications.

EDM Administration Utility

The EDM Administration Utility is used to configure and implement database settings from a
single location for all the applications. This prevents future duplication of information.

The following operations can be performed using the EDM Administration Utility:

Create and customize EDM Output Reports (you must purchase Crystal Reports 9 to enable
this), System Settings, and Unit Management Sets
Create and customize OpenWells Data Entry Forms, Preview Panes, Shortcut Bars, OpenWells
Carry Overs and Status Colors
Configure EDM Security
Import and Export source files and EDM Administration Utility configurations
Generate EDM Schema for output reports

MSDE Administration Utility

Use the EDM MSDE Administration Utility to perform the following functions:

Install MSDE (Microsoft Desktop Engine) if it is not present on the local machine
Create a blank copy of the EDM database
Attach an EDM database file to MSDE
Create two default users for new MSDE databases:
username: EDM, password: landmark (Default application user)

Drilling Data Migration

Please refer to the EDT Drilling Migration Guide for instructions on using the Drilling Data
Migration Toolkit.

Production and Economics Data Migration

EDM provides support for Production and Economics applications on a shared data model.
Production and Economics data can be migrated from a 2003.4.2.0 AFS Database, a standalone
2003.41 ARIES Database, or a standalone TOW Database using a variety of tools and
executables. Please refer to the EDT Production and Economics Database & Migration Guide
(EDT_PE_Database_&_Migration.pdf) for more information.

EDT 2003.14 P & E Global Release Notes Page 19 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Unit Converter

Use the Unit Converter application to convert a data value from one unit system to an
equivalent unit system based on unit types (categories) defined in the database.

EDM Report Manager

This application is used to view, save, and send Output Reports created with the EDM
Administration Utility and available to the OpenWells and COMPASS applications. Landmark
plans to implement this Report Manager in other EDM applications in future releases.

EDM Services Utility

The EDM Services Utility is used to configure encryption, Field Office Data Transfer database
connection information, sender and receiver information (email addresses, monitored
directories, email servers, network login information, login information); to configure the
SAM (Simultaneous Activity Monitor) server (host name, port number, server name and log
file); and to configure database connection information for the EDM Publishing Service
application. All data is compressed when sending.

EDM to OpenWorks Link

EDM-OpenWorks Link is a tool that enables you to map wells in the selected EDM database
to projects in the selected OpenWorks database. This association between databases is called
mapping. After a well is mapped to a project in OpenWorks, you can use the Engineer's Link
application to transfer data from the EDM database to OpenWorks.

For this release of EDM-OpenWorks Link, the mapping is enabled in one direction only: EDM
to OpenWorks.

EDM Publishing Service

The EDM Publishing Service is a application that enables automated or manual generation of
OpenWells Reports in printed (hard copy) or electronic (.PDF) format.

EDM Publishing Service Controller

The EDM Publishing Service Controller runs in the Windows System Tray, which gives quick
access to the EDM Publishing Service application and Publishing Service Status.

EDT 2003.14 P & E Global Release Notes Page 20 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

EDM Services Controller

The EDM Services Controller runs in the Windows System Tray and enables EDM Services to
be started, stopped, and restarted. The following Services are managed by the EDM Services
Controller: LGC EDM Data Receiver (Email), LGC EDM Data Receiver (File System), LGC
EDM Simultaneous Activity Monitor, and LGC EDM Publishing.

Production and Economics

Selecting Production and Economics installs the following applications:

Desktop Navigator
ARIES
ARIES International
ARIES/RMS
DSS
TOW/cs
Choosing Applications for Installation

If you do not wish to install one or more of the P & E applications, select the
desired applications from the tree structure by clicking in the appropriate box.

Desktop Navigator

The Desktop Navigator allows you to access the entire Engineers Desktop suite of applications
from a single Graphical User Interface (GUI).

ARIES

ARIES (Deterministic Economics & Reserves Management) is the integrated, easy-to-use


solution that enables economics, engineering, and business teams to efficiently organize,
manage, and evaluate economic, reserves, and production data. Rapidly and accurately assess
changing market conditions with this fast and flexible tool to maximize the profitability of
your hydrocarbon reserves. ARIES combines sophisticated graphics and analysis capabilities
with a robust economics engine to significantly improve productivity. Powerful project
management capabilities give engineers and managers the means to evaluate corporate
prospects at any level of detail. ARIES is unparalleled in its ability to analyze, consolidate and
report large numbers of properties.

ARIES International

ARIES International is a new solution that extends the widelyused ARIES economic

EDT 2003.14 P & E Global Release Notes Page 21 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

application. this tool empowers companies to evaluate complex fiscal regimes anywhere in the
world and consolidate the results. It replaces multiple evaluation tools with one, and retains the
familiar ARIES workflows, rollup strengths, and decline curve analysis. The results flow
seamless into the reserves management and the portfolio management system.

By supporting various levels of user expertise ARIES International satisfies the need for both
rapid model customization and consistent, secure deployment of models for company users.
Company experts can use the fully customizable modeling engine to create the exact
calculations they need for their contracts, and publish these models for the nonexperts within
the company to use in day to day evaluations. Intermediate PSC Super Template to quickly
assemble needed combinations of fiscal terms. In all cases, the expandable Fiscal Function
Library saves time and increases accuracy.

ARIES RMS

ARIES RMS (Reserves Management System) tracks your reserve changes on a property basis.
Using RMS, you can define several booking proposals using economic and/or volumetric
calculations. After making your proposals, you can compare them to each other and to the
previous booked reserves prior to selecting one of the proposals for booking. Once you select
a proposal, you can either book your properties separately, or use the Mass Booking function
to book a group of properties.

When you book reserves you are assigning specific remaining reserves to a property at a
specific point in time. Although you may run economics on a property several times a year, you
usually book reserves only annually or semi-annually. When you perform the booking
procedure, RMS stores the reserves and date in the RMSRESERVES table.

DSS

DSS (Dynamic Surveillance System) helps production and reservoir engineers add reserves
and increase profitability. The tool provides a powerful, easy-to-use graphical interface to
evaluate a variety of data. DSS lets you search for anomalous reservoir behavior using dynamic
bubble, pie and contour mapping. Workover and stimulation opportunities are identified easily
by monitoring well production curves and failures. Completion and structural relationships
between wells can be compared by displaying wellbore, log and zone data in a cross section.
The powerful grouping, normalizing and decline features of DSS enable you to determine
which completion or drilling technique is most effective.

DSS allows you to view surface, bottomhole, or even surveyed well locations with only a few
mouse clicks. You can create relevant maps and select a well to display its historical production
curve, while looking for inter-well communication from a recently drilled producer. Your data
are always readily available to analyze cause-and-effect situations within the field. Such
accurate and timely production data are invaluable in making correct economic and
engineering decisions, and in complying with state and federal accounting requirements and
reporting regulations.

EDT 2003.14 P & E Global Release Notes Page 22 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TOW/cs

TOW/cs provides a complete production data management system. The TOW/cs software
application offers functions for setting up facilities, as well as capturing, managing, graphing,
and optimizing production data. There is also builtin reporting functionality.

TOW/cs stores data on a monthly basis, providing corporate access to an active production
history repository. Because everything is conveniently located in one place, you no longer need
to move data to evaluate reserves and economics. The system handles data communication
between field sites and central corporate databases, allowing field and office to be
synchronized like never beforeeveryone sees information in the same format.

EDT 2003.14 P & E Global Release Notes Page 23 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Installation
The Engineers Desktop software is delivered on multiple CD-ROMs, Volumes 5, 6, and 15. You
can install all of the Engineers Desktop applications by referencing the individual Installation
Guides:
EDM Installation Guide, volume 5
EDT Drilling Installation Guide, volume 6
EDT Production & Economics Installation Guide, volume 15

Once you have completed the individual installations, the guides will be saved to your hard drive
under the documentation folder (c:\Landmark\EDT_2003.14\Documentation).

Troubleshooting the Installation

Remember to reboot your computer before attempting to use the Engineers Desktop. If you run
into problems, please refer to the Installation Troubleshooting section of the Corresponding
Installation Guide.

EDT 2003.14 P & E Global Release Notes Page 24 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Licensing
For Engineers Desktop R2003.14, all PC and UNIX products including the Engineers Desktop
applications support use of FLEXlm licensing, which is the only licensing mechanism sup-
ported by Landmark. FLEXlm licensing has been supported with past releases, so many clients
will already be using this licensing mechanism. FLEXlm licensing is available for networked
application and standalone application use. FLEXlm standalone licensing may be used in con-
junction with a network card or through a FLEXlm dongle (bitlock) where no PC network identi-
fication is possible.
Previous versions of the Drilling applications and the Production & Economics applications sup-
ported use of a proprietary Landmark licensing mechanism called Netsecure for networks. Addi-
tionally, Sentinel bitlocks attached to a PCs parallel port could be used for licensing of standalone
installs, Crypkey licensing was also supported for standalone installs. Use of Netsecure, Sentinel
bitlocks and Crypkey has been discontinued by Landmark and is not supported for use with
Release2003 products.
The EDM R2003.14 applications require that an EDM license feature be available from the cus-
tomer's licensing server in order for the Engineer's Desktop applications to run. The EDM license
is handled as a Group Checkout for each application user on a particular PC. Only one EDM
license is checked out for all Engineer's Desktop applications being run by a user on a single
machine. Therefore, clients will need to acquire a set of EDM licenses based on their expected
concurrent user level. Please contact your local Landmark representative for EDM licensing.
Existing EDM and application licenses are valid for customers who have installed and run ver-
sions of EDM 2003.5 and later.
If you have:
2003.11 installedyour licenses are all valid for 2003.14.
2003.5 installedyou must obtain a new EDM license
W2000 installedyou must re-license your applications and obtain an EDM license.
To re-license, customers must contact their local Landmark representative. Refer to the LAM
2003.0-Windows Release Notes (LAMReleaseNotes.pdf), located in the \Prod-
ucts\EDT\Install\LAM folder on CD 5, for details.

IMPORTANT! If you have a version of LAM server older than 7.2e (Release 2003.0 and later), you
must uninstall it before installing the LAM 2003 server.

Failure to uninstall all previous versions of LAM Server before installing LAM Server 2003 will result in a
duplicate FLEXlm service that replicates itself until it crashes Windows.

The procedures for uninstalling LAM server are detailed in the section LAM Server - Uninstallation Notes in
the LAM 2003.0Windows Release Notes (LAMReleaseNotes.pdf), located in the Products\EDT\Install\LAM
folder on CD 5. Products that were licensed under the older server will still work with the new LAM server.

EDT 2003.14 P & E Global Release Notes Page 25 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

IMPORTANT! If you are using a FLEXlm dongle (bitlock), you must install FLEXlm 7.2i on the
standalone or client machine.

To install FLEXlm 7.2i for bitlocks (either parallel or USB):

1. Go to your installed \LAM\bin folder, and run flexid.exe to install the bitlock drivers.

2. To request a bitlock license, run \LAM\bin\lmtools.exe. Select System Settings tab; provide the value you see
in the FLEXID9 field.

EDT 2003.14 P & E Global Release Notes Page 26 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

EDM Roles for ARIES, DSS, and Desktop Navigator


ARIES, DSS, and Desktop Navigator each require users to be granted specific database roles in
order to gain access to the EDM database.
The configurable roles are:
ARIESROLE Add this role if the user will be running ARIES or DSS.

RMSROLE Add this role if the user will be running ARIES RMS.

DESKTOPROLE Add this role if the user will be running the Desktop
Navigator.

DSSROLE Add this role if the user will be running DSS

EDMROLE Add this role to run the Engineers Data Model database.

RTS Role Add this role if the user will be running OpenWire
Production.

Roles in the EDM Database

Roles grant specific privileges to certain tables within the EDM Database. For a complete list of tables
and the privileges granted by each role, view Appendix A.

Configuring Roles

You can configure roles for each user in a variety of ways:

Using the EDM Administration Utility

Executing an SQL Script against the database

Use the databases graphical tool to grant a user role

Using the EDM Administrator to Set up a Role

To configure a user role through the EDM Administrator:

1. Launch the EDM Administration Utility.

2. Log into the Data Source.

3. Expand the EDM Security.

EDT 2003.14 P & E Global Release Notes Page 27 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

4. Expand Users.

5. Select the user you wish to configure.

6. Select Grant or Revoke on each role.

7. Click the Save button to save the selections.

Using Oracle to Set up a Role

The following instructions describe using Oracle to set up the roles.

User Created by TOW/cs Utility

When the user is created with the TOW/cs Utility the VCR_INQUIRY role is granted automati-
cally and additional roles can be added by using the following commands:

EDT 2003.14 P & E Global Release Notes Page 28 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

grant user <USERNAME> <ROLENAME,ROLENAME...>;


alter user <USERNAME> default role VCR_INQUIRY, <ROLENAME,
ROLENAME...>

Example: Scott is the user and he will be using TOW/cs, ARIES, and DSS. The command is:
grant user scott ARIESROLE,DSSROLE;
alter user scott default role VCR_INQUIRY,ARIESROLE,DSSROLE

User Created Outside of TOW/cs

When the user is not using TOW/cs, a default role is not necessary and the grants to other roles
can be achieved using the following commands:
grant user <USERNAME><ROLENAME,ROLENAME...>

Example: Scott is the user and will only be using ARIES and ARIES RMS. The command is:
grant user scott ARIESROLE,RMSROLE, VCR_INQUIRY

Example: Scott is the user and will only be using DSS. The command is:
grant user scott ARIESROLE,DSSSROLE, VCR_INQUIRY

Using SQL Server/MSDE To Set Up a Role

When the user is created with the TOW/cs Utility the VCR_INQUIRY role is granted automati-
cally and additional roles can be added for this user or a user without TOW/cs by using the fol-
lowing commands:
sp_addrolemember <ROLENAME>, <USERNAME>

Example: Scott is the user and will be using ARIES, and DSS. The command is:
sp_addrolemember ARIES, scott
go
sp_addrolemember DSSROLE, scott
go

As an alternative method, use the Enterprise Manager Utility to set up a role:

1. Select the database.


2. Click on Users.
3. Double Click on the User name.
4. Assign roles by adding check marks next to the roles.
5. Click OK.

EDT 2003.14 P & E Global Release Notes Page 29 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Listing Tables and Permissions by Role

To display the list of tables and the permissions that each role grants, execute the following SQL
statements against the database.

SQL Server/MSDE
Select Grantee as RoleName, Table_Name, Privilege_Type from
INFORMATION_SCHEMA.TABLE_PRIVILEGES
where Grantee = DSSROLE
Order By Table_Name, Privilege_Type

Oracle
Select Grantee as Role_Name, Table_Name, Privilege from
USER_TAB_PRIVS
where grantee = DSSROLE
Order By Table_Name, Privilege

EDT 2003.14 P & E Global Release Notes Page 30 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Integrated Workflows
The Engineers Desktop 2003.14 release provides a comprehensive set of workflows that
demonstrate to the user the full benefit of deploying Drilling, Production, and Economics
tools on a single data platform. After installation, you can view these workflows by select-
ing Workflows from your EDT.chm online help file.

EDT 2003.14 P & E Global Release Notes Page 31 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Enhancements and New Functionality


In this release of the Engineers Desktop, Landmark continues to develop and fine tune the Desktop
Navigator. The Engineers Desktop is used to organize and manage Wells, Wellbores,
Completions, and/or any top-level database object.

EDM Common Interface Components for Production & Economics


Applications

Login Dialog

Engineers Desktop (EDT) applications are run against a database, SQL Server, MSDE, or Oracle
Enterprise. Use of a database requires that the user log into the application so that database
permissions and security levels may be determined. All EDT applications share the same common
login dialog. Use of the common EDM Data Services layer means that a user need only login into
a EDT application once. EDT applications that are subsequently launched will automatically use
the initial login information, so the user does not need to re-login for each application.

Property Dialogs

Accessible from the right-click menu, each hierarchical node (level) displayed in the Well Explorer
has its own Properties dialog, which is used to create new node objects or modify existing objects.
The contents of the Properties dialogs can vary between applications. Information present is
configured for each application, so the data displayed is only that which is relevant for the currently
open application.

Locking Support

Property dialogs support locking of data levels, which is a simple toggle feature used to prevent
accidental updates/changes to data. Locked levels signify to other users that the information
should not be changed. Used in conjunction with Data Passwords entered at the Company level,
the locking feature can be used to further protect data from unplanned changes or deletions.
You can lock the Company properties only, or individually lock other data levels (Project, Site,
Well, Wellbore, Design, Case, etc.) as well.

Data Auditing

EDM provides automated auditing support for all data sets in the database. EDM automatically
logs the User name, Application name, and Date/Time when each object is created and last
updated. Users can provide additional documentation describing changes to the data in the
available Notes field.

EDT 2003.14 P & E Global Release Notes Page 32 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Unit Systems Editor

The Unit System Editor is available to all EDM applications in the Tools menu (Tools > Unit
System). A major component of the EDM Unit Management System (UMS), the Unit System
Editor enables users to create or change selection of their active display unit sets. EDM ships with
two system unit setsAPI and SIwhich cannot be edited. However, users can make copies of
these unit sets to create their own custom unit sets which may be changed. Unit sets are stored in
the database and are therefore available to all users. You can also import and export unit systems
(you cant use reserved characters).

The EDM database supports storage of data to a consistent storage unit set. With the Engineers
Desktop release, this storage unit set is fixed to store data to API units.

EDM Data Transfer Files

A significant component of the Engineers Desktop release is support for .XML EDM data transfer
files that enable users to export and import EDM data at different levels of the EDM data hierarchy
to facilitate movement of data between EDM databases. Part of the Data Services layer, the Data
Transfer Export generates a .XML file which may be copied, emailed, or sent to other EDM sites
where that information may be imported. This .XML file format supports inclusion of Blob data
such as logo images stored within EDM.

When doing an XML import into a database, Landmark strongly recommends that you close any
open data sets in the application unless you know they are not related to the contents of the
imported data transfer file; the transfer process will not update open data items. Changes made by
the import process will not be visible in open items until these items are closed and re-opened or
refreshed.

EDM Common Interface Components for Drilling & Completions


Applications

Please refer to the EDM Release Notes for more information on the EDM
Common Interface Components for Drilling & Completions applications.

EDT 2003.14 P & E Global Release Notes Page 33 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Production & Economics Enhancements and New Functionality

The EDT Production & Economics Global Release Notes document (this document) lists all
enhancements, fixed defects, and known issues for the Engineers Desktop, Desktop Navigator,
ARIES, DSS, and TOW/cs.

Engineers Desktop

NT Authentication

The NT Authentication is a new feature available in this Production and Economics 2003.14
release. This feature allows you to use Windows NT user names, passwords and domains to
control the security logins of your application. This centralizes your security profiles within the
Windows NT framework (rather than using the internal application framework).

ARIES

Project Manager

Property/Data Management Column Calculator

The user may calculate column values for a range of rows.

Property/Data Management Data Importer

A new dedicated method is now available to import production data from DrillingInfo.

Report Names Auto Refresh

ARIES automatically refreshes the reports list names after you save a new report.

Property Data Management Picklist Counter

The Pick list Counter displays both a value for Marked Properties and the Marked Properties
and Sums for the current item.

EDT 2003.14 P & E Global Release Notes Page 34 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Property Data Management Unicode tolerant

The ARIES underlying database now accepts unicode data types.

Economics Module

Calculations Group Economic Calculations

ARIES will perform both economic limit and payout calculations at a Summary Group level.
The members of the group are automatically rerun using these calculated dates.

Calculation Time Frames

ARIES will generate up to 128 reporting time frames. This allows for more detail
(i.e.; budgeting). This new functionality will change the structure of the SUM files, so the user
will not be able to mix the new files with the old files when performing a summary run.

Data Output Expanded Output Streams

New functionality populates the output array and sum files with up to 400 streams of results.

Data Entry New Spreadsheet

New ARIES functionality features a pop up spreadsheet data entry method where the user
can list, copy, or paste production forecasts.

Data Entry Variable DELAY Option

Included in the ARIES application, is a START date option for a variable delay period (number
of months) to automatically shift the beginning point forward or backward. A user can also
combine this new feature with the ENDDATE to model a delay in starting workovers.

Data Entry Investment Section

There is no limitation on the number of investment lines that can contain the RISK X
procedure.

EDT 2003.14 P & E Global Release Notes Page 35 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Calculations Decline Calculations

When using the hyp/exp switchover procedure in the ARIES economics package, the decline
curve forecasting matches the MultiGraph results.

Data Entry Economic Titles

ARIES now offers the ability to enter blank lines within the economic title section so that the
user may tailor the appearance.

Economic Run Settings Delete Output Option

ARIES now features an option (Delete Output Before Run) you can use to automatically delete
the economic output file at the start of each run. This option is located in the Miscellaneous
area of the Output tab on the Economic Run Settings dialog.

MultiGraph Module

Trend Alignment

ARIES permits up to 500 wells to be used in the Trend alignment analysis method.

START Data Lookup

MultiGraph can use the start date from the economic data lines that contain the lookup entry:
@M.STARTDATE.

Plots Default Plot Orientation

Landscape mode is the new default plot orientation for ARIES. Use the Graph Preferences
dialog box to set the orientation to Landscape or Portrait.

Plots Tab Entries

Tab functionality has been added to the ARIES Plot Title line dialogue text to enable the user
with better formatting capabilities. Use the backslash t (\ t) command to set the tab stop, as the
actual tab button on your key board has been designed to move you to the next dialogue box.

EDT 2003.14 P & E Global Release Notes Page 36 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Status Bar

For improved usability, the SHOW ID box on the multi-graph status bar has been enlarged.

ARIES International

This is the initial release of ARIES International, please look for subsequent releases for new
enhancements and functionalities.

ARIES RMS (Reserves Management System)

Several enhancements have been added to the 2003.14 Release of ARIES RMS. These
enhancements include improved interim production adjustment methods and a second booking
approval level. The second booking approval level also includes a freeze procedure for
reserves and revision values, which will help the user community with their close outs at year
end.

Desktop Navigator

NT Authentication

There is not an NT user setup within these applications. They connect to any ODBC data
source. The database administrator configures NT Authentication within the applicable
database setup.

The database administrator uses the EDM Administrator Utility to create NT users and grant
NT user rights. The Desktop Navigator Login dialog has an Edit check box. When the user
marks the Edit check box, the Edit Connection dialog displays.

On the Connection tab, there is a Trusted Connection check box. Checking this box and
clicking OK automatically enters the current Windows login User ID in the disabled Username
field on the login dialog.

Templates

PIck List Editor

Use the Pick List Editor to create and manage pick lists used by the Template Designer.

EDT 2003.14 P & E Global Release Notes Page 37 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Related Tables Editor

The Related Tables Editor was developed to allow Desktop Navigator users the ability to add
extensions to the data model and to expose these extensions through the templates.

Template Designer

The Template Designer provides a common base for visual layout tools such as graphical
facility setup, chart layouts, and screen template designs.

Template Management

The Template Management provides a management tool and storage space for template related
settings and editing.

Data Management

OpenWire Production Data Management

OpenWire Production Data Management retrieves data from the OPC servers and transfers the
datum to EDM.

OpenWire Production Host Management

OpenWire Production Host Management configures the OPC host that you will be using and
retrieves your tags.

Formulas

Formula Editor

The Formula Editor has been created to assist the user in the formulation creation process. You
may also edit existing formulas using this functionality.

Formula Results

This new functionality displays the results of the formula calculations.

EDT 2003.14 P & E Global Release Notes Page 38 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Table Properties

This functionality was developed to assist the user in adding or deleting a new group, adding
or removing a table, and/or saving or closing the current table properties.

Tools

Toolboxes

Use the Toolbox to display or hide the Attachments, Launch Bar, Entity Explorer, or Properties
windows. You can also reset the default Desktop Navigator settings or restore your last saved
settings from the Toolbox list.

Entity Explorer

Entity Explorer List View Update

The Entity List View has been improved to expose additional entity types.

Entity Explorer Route Stop

An enhanced tree structure has been applied to the 2003.14 release of the Desktop Navigator.

Properties

Entity Properties Toolbox

The Entity Properties Toolbox now displays the ID, Name, and Type of entity or entities
selected.

Snap-Ins

There are now ten Landmark shipped Snap Ins shipped with this 2003.14 release of the
Desktop Navigator. Please refer to the Desktop Navigator online help for further details.

EDT 2003.14 P & E Global Release Notes Page 39 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

DSS

NT Authentication

There is not an NT user setup within these applications. They connect to any ODBC data
source. The database administrator configures NT Authentication within the applicable
database setup.

Map Charts

Enhanced Map Chart Montage

The map chart functionality supports the ability to plot eight variables as well as x y plots.

Subsurface Display Options Dialog

Downhole Equipment Annotations

The user may now customize Downhole Equipment Annotations.

Tools Menu

Back Allocation Option

Use the Back Allocation Option to calculate data from child entities. The allocation will be
calculated using source value splits from the parent entity.

Declines

Auto Cum feature

The Auto Cum feature has been removed and now allows the user to forecast other variables
in the decline chart.

Chart Decline Options Dialog

A new field has been added to this dialog box and automates the decline rate changeover from

EDT 2003.14 P & E Global Release Notes Page 40 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Harmonic or Hyperbolic decline to an Exponential decline depending on the decline rate.

Workbook Options Dialog

Use the Auto Refresh Interval field to set the time interval for the automatically refresh your
workbooks.

ID Cross Reference Extension

New development has been applied to the ID Cross Reference and extends the functionality to
cover areas not covered by the calculation engine.

Graphs

Use the Deep Copy option, located on the Workbooks rightclick menu, to create a full copy
of the workbook, worksheet, and subsequent charts thus giving yourself the ability to create
new graphs.

Grids

Users may now copy the grid header to the clipboard after selecting the header.

Functions

This release of DSS now offers the @FORMAT, @NOW, and @TODAY functionality.

@FORMAT. Gives the user more control over the presentation of data in reports and
posted values.

@NOW. Returns the system date with and without a time stamp.

@TODAY. Returns the system date with or without a time stamp.

Note: @NOW and @TODAY functions are useful for surveillance calculations
requiring comparisons with an actual date.

OpenWire Production

The database administrator uses the EDM Administrator Utility to create NT users and grant
NT user rights. The Desktop Navigator Login dialog has an Edit check box. When the user
marks the Edit check box, the Edit Connection dialog displays.

EDT 2003.14 P & E Global Release Notes Page 41 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

On the Connection tab, there is a Trusted Connection check box. Checking this box and
clicking OK automatically enters the current Windows login User ID in the disabled Username
field on the login dialog.

TOW/cs

Common Login

A Common Login has been developed for this 2003.14 release. Once you have logged into an
application, any subsequent application you open, whether as a Desktop Navigator snapin or
outside the Desktop, will not require input in the login or password field.

Job Scheduler Login

Please note, the Job Scheduler will not use the shared memory established
by the registry table that is accessed to create the common login
functionality.

NT Authentication

NT Authentication can be used to set up external users. The TOW/cs Login screen features a
Use Windows Authentication checkbox. If your company decides to use NT Authentication,
and your database administrator has set the end user up as an NT user (or external user), the
end user simply checks this box and the end users external User ID automatically enters in the
User ID field.

Creating an NT User

To create an NT User, the database administrator must first set up the NT User outside of
TOW/cs using the database tools that are provided by the database vendor (this cannot be done
through the TOW/cs Utilities module).

After the NT User is set up within the database, the TOW/cs administrator can open the
TOW/cs Utilities module and access the User Accounts dialog by selecting Tools > User
Accounts from the main menu. There, the administrator will see a column labeled NT User. In
this column, a checked box appears on the row next to any user that is an NT User (external
user). If the user was setup using the Utilities application, then he is an internal user and the

EDT 2003.14 P & E Global Release Notes Page 42 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

box is unchecked for that column.

Note

If you do use NT Authentication, the User ID and Password


fields on the Edit TOW/cs User Account dialog are disabled
and can only be maintained by the database administrator
outside of the application. However, you can still maintain all
of the information in the Groups section of the dialog.

EDT 2003.14 P & E Global Release Notes Page 43 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Problems Fixed
Many legacy problems have been fixed for the Production & Economics release of the Engineers
Desktop version 2003.14. The following list includes all P0 and P1 defects and enhancements that
have been resolved, and the patches that included them, since the 2003.11 release of the Engineers
Desktop.

Fixed Problems in Production & Economics Applications

ARIES

Patch 2003.11.0.2

Defect Case No. Description


124366 267817 CALDAY curve not abandoning at specified EUR from PZ table.
125691 Landmark CUM on CALDAY is incorrect for Summary Level plot.
129917 292605 Ratio lines are drawn incorrectly when retrieving forecasts.
131781 Landmark CUMS written to Econ with Back forecast turned off.
134703 704442 MG does not read the start date if it looks like this in Econ: @M.STARTDATE.
139771 Landmark Hyperbolic fit with Exp Switch does not honor EUR abandonment.
614017 930870 Enhancement request to increase the number of wells allowed in Trend.
90146 261159 Cannot fit Hyperbolic Incline. Try Exponential fit instead with manual hyperbolic fore-
cast.

Release 2003.14.0.0

Defect Case No. Description


149912 Landmark Economic Excel Load: does not recognize currency format.
150451 Landmark Accumap - Item was not found error displays when dump file has injection data.
615340 1011512 Multigraph display of summary data for non-producing cases.
616391 1011663 Using Oracle OS Authentication with ARIES.
629973 1061668 Severence tax overlay is not included in stream 747.

EDT 2003.14 P & E Global Release Notes Page 44 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Desktop Navigator

Release 2003.14.0.0

Defect Case No. Description


615287 Landmark Sorting Entities List - Cannot find Column XXX issue.
616583 Landmark Message when locking an entity is incorrect.
617417 Landmark Verifying all web links during start-up, so if one site is down, the launch takes more
than five minutes.
617441 Landmark PanSystem is not available from Desktop Navigator.
617567 Landmark Pressing F1 in the Entity Properties panel fields delivers a Page cannot be displayed
message.
617595 Landmark Attachment File Path should allow UNC paths as Attachment Properties panel allows it.
632710 1068058 Desktop Navigator Real Time Surveillance - Host Name field is too short.

DSS

Release 2003.11.1.0

Defect Case No. Description


166244 Landmark Map Formats: New map prompts to save in formats that haven't been created.
166249 Landmark Group and Report Footers are not using the selected width of page.
166311 1011441 Map Scale is incorrect on screen but correct on Printout.
168543 Landmark Calculation engine parsing fails when the formula begins with a unary operator.
170459 Landmark Map: Group ID instead of Name in the Pie Grouping Membership dropdown.
171071 Landmark Receive error when Calculate location from center of group is chosen.
177289 926540 GPF when creating the first new annotation filter on chart.
178825 931696 The Histogram Chart probability curve should be plotted on the R1 axis.
178826 931696 The Histogram Chart is normalizing the probability curve.
178840 931696 The Show Values Tool does not show decimals when right clicking on any chart.
178893 931604 The x-scale dates in the chart montage show wrong start date when date range is greater
than 25 years.
179802 934631 @TOTAL returns incorrect volumes when there are nulls with &weighted or &interp.
180063 Landmark Format Conversion: Monthly Batch Build loses it Time Step.
180066 Landmark The X versus Y Chart loses a data point when viewed as log-log.
180067 Landmark Build Wizard is malfunctioning.
180374 Landmark DSS exits with no warning when declining on some wells.

EDT 2003.14 P & E Global Release Notes Page 45 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Defect Case No. Description


612038 Landmark DSS hangs up when using the &STRAIGHT option in @AVG.
612191 Landmark Build Wizard shows a list of entities on the group selection page.
612280 Landmark Wizard Range page showing for tables without resolution join types.
612285 Landmark Need to update the default Join Types list with all new columns.
612491 Landmark DSS Sample DB is version 2003.11.0 instead of 2003.11.1.0
612709 Landmark Chart Montage format does not save streams if saved publicly.
612899 Landmark Auto decline does not give a message when a fit fails.
612968 Landmark Records mode should not be available for charts of dynamic group data.
612898 Landmark Auto Decline with the Best option causes DSS to disappear if an incline is generated.
613043 Landmark Auto Refresh has range from 5 to 120 inclusive seconds instead of 5 to 300.
613046 Landmark Rolling up an Instrument to a completion on a daily level gives an extra day in the
results.
613191 Landmark Open Chart Options - Range node and DSS will malfunction.
613224 Landmark Problem with Conversion of DSS 2003.4.1.1. Database to 2003.11.1.0.7562.
613328 Landmark Header chart does not show PID and PTYPE for entities that do not have a rollup set.
613467 Landmark Conversion does not take into account project settings for ID data type when creating
new default tables.
613623 Landmark Join Types are not updating when converting from 2003.11.0.0 to 2003.11.1.0.
614523 Landmark Exploded well shows all data source columns in chart instead of first column only.
614709 Landmark Workbook Open Options\Method other than Standard do not work.
614727 Landmark DSS will malfunction when pressing F1 on a Header Chart.
615007 1011441 Map Scale not showing in the Main Legend.
615167 Landmark Table qualifier in dynamic locations needs to be removed.
615187 Landmark DOCS: Map Wizard and Workbook Wizard have lists of incomplete entities.
615866 Landmark EDM project creation creates tables that should not be there.
615937 Landmark A group build to a new table has only PID and PTYPE columns, no data.
615952 Landmark The Criteria field is not showing by default therefore criteria will fail.
616481 Landmark Canceling out of the Group Build dialog causes DSS to crash.
616362 Landmark n_ columns in group builds are not getting the correct entity count.

EDT 2003.14 P & E Global Release Notes Page 46 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Patch 2003.11.1.1

Defect Case No. Description


616260 1014896 Forecast curve and footer values are not refreshed after changing any decline limit.
616573 Landmark DSS crashes after exit with a certain scenario.
617073 Landmark Saving temporary group forecasts to a table produces errors.
617100 Landmark Decline: cum part of WOR chart shows annual decline, Forecast Editing screen has
daily.
617120 Landmark Multiple listings for each group and increases after selection on Map Options setup,
Color of pie charts is lost in this process also.
619317 1025272 Linear regression fit and formula may not match the data points.
619838 Landmark User gets an Error Opening Format after canceling in the Deep Copy option.
620515 1028873 Normalized Group Build displays error message: norm days cannot contain a null.

Release 2003.14

Defect Case No. Description


621593 1034078 DSS will GPF when pressing the arrow keys on the keyboard when a Header Chart is
active.
623919 1073435 The Decline Solver Parameters options for the Rate vs Cum charts do not match
enabled boxes.

TOW/cs

Patch 2003.4.2.5

Defect Case No. Description


173582 1067020 Enter/enter keystoke sometimes skips an entity.
176212 1023077 Get error when clicking AboutBox in most modules for Oracle.
178714 1006813 Run tickets created by Use Sum of Dailies on prod meters not used for theoretical.
612338 Landmark Special characters are not working.

Patch 2003.4.2.105

Defect Case No. Description


141521 222264 LA - By Field needs to have usage points available for selection/setup.
150935 822778 MMS/OGOR Injected volume totals must be included in the T3 record on EDI.
163694 872762 NM - report has incorrect order of oil, water, gas lines on POD listing.
169172 893112 NM Water Production column/data not showing when viewing report.

EDT 2003.14 P & E Global Release Notes Page 47 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Defect Case No. Description


169497 897409 WY 16 A - Edi File puts blank spaces after operator code.
172541 925043 NM amendments should be submitted as total report resubmitted.

Patch 2003.4.2.6

Defect Case No. Description


130381 Landmark Down periods date range lost when data entry screen opens.
145960 796718 TDML Activity Monitor loses initial inventories if allocated results are edited.
147136 934714 Accessing Related Entities screen through Other Usage Points gives error.
151974 825194 Allocation code on gath sys set-up not defaulting to 01 if well head meter on well.
154827 841760 Desk Security incorrectly preventing access based on similar templates.
161867 865158 Enter more than one run ticket using + and gross and net only calc on last ticket.
162545 1020941 Call Sheet - should scroll down one record at a time as new volumes are entered.
163415 1056249 If a well is shut in and gets a volume allocated to it, should be a fatal error.
165584 882640 Filtering by entering the first few letters hangs the selection if delay is less than 0.6.
165639 Landmark Saving copied data bumps the cursor back to the entered record or one day forward.
165840 891395 R_205 Daily History report errors if downtime in hours and minutes > 3 digits.
167329 884868 Hourglass does not display during entire save.
169108 870235 Request that no record be written to Proc stat if system allocated before eff date.
169129 896492 My Desk Filter is not working unless combined with another filter.
169564 1034670 Clearing and not validating required date effective fields on set up screens.
169920 1030929 Entire disposition volume should go to only station w/ theoretical even if up=down.
170317 903636 BAPI call fails when setting up new BA if BA type, can't save after fixed.
172133 911512 Related Entities not showing all information when launched from a completion.
173251 1062878 Users are getting Object variable or with block variable not set errors.
176573 1022456 Daily allocation not using the correct theoretical when MO tank in the system.
178125 1062877 Volumes in Gas Receipt column are doubled in the Summary tab when using 810 meter.
179102 1042654 Call Sheet: BTU Content doesn't get recalculated when volume is changed.
614924 Landmark When importing or exporting the Job Scheduler does not display the information.
616977 1022156 TOW/cs Export- get Caught an unhandled exception error.
617600 1018597 Completion in oil gathering system with 99 code is still getting water allocated.
617816 1019990 Export process missing some well tests and run tickets records when creating files.
617897 1020158 Getting dup record error on alloc that has multiple tickets with different oil prod
codes.

EDT 2003.14 P & E Global Release Notes Page 48 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Defect Case No. Description


619143 1033683 Copy forward (ditto) shift-F4 and prorate shift-F3 are not seeing newly saved records.

Patch 2003.4.2.106

Defect Case No. Description


72019 1009052 LA Amended Report Creation picking up leases with no changes.
133135 282408 LA OGP - Oil Disposition Pulling From Previous Page if Blank.
134802 905055 Reg - Duplicate field names appear in Regulatory select list WY, LA, TX.
138636 842579 MMS/PASR for an FMP should only include volumes for equipment on the FMP.
148104 806061 Regs - reports should be able to get mid-month status info from PA.
149638 Landmark Regs - Slow screen load when bringing up View Select Screen.
149639 Landmark Regs - Slow load of Close Finalized Version Screen. Needs a way to filter.
149641 868262 CO - Adjusting column needs to be able to accept a negative volume.
168048 891780 NM: API gravity value being truncated to 2 digits instead of 3 in edi file.
169162 896665 CO 7 TA well status shows as SI on report.
169329 897478 MMS/OGOR Header/Footer lease showing incorrect contact after it is changed.
169958 887326 NM- Edit by Well/Well POD Cross-ref should not require equipment field.
172986 891288 Regs: closed versions show up and can be selected from View/Edit Open Versions.
173203 915302 Regs - selecting by operator pulls up everything for the contact name.
177064 925478 TX H10 is incorrectly showing 0 number of readings when other values are all 0.
177787 Landmark Regs - unclose open report screen doesn't retrieve all records.
612794 1035554 Amended reports created for fields with no changes when Create by Contact.
612808 1004235 LA By Field select screen should filter by Field name.
613818 1050168 When creating reports for a field with multiple operators, only one creates.
614136 1009064 LA on screen - no version info for reports.
615970 1013871 CO Injection pressures for disposal wells not coming across from accounting to EDI.
616333 1015170 View Utah report select screen needs to have well name choice in select by.
616335 1015181 No way to end date a well which needs to be dropped from the Utah reg report.
616848 1016170 North Dakota report BS&W Drawn column shows running total rather than each well's
volume.
617012 1015511 CO Form 14A report gets created for producing wells but not for injection wells.
617014 1015511 CO Form 14A - Range info for source wells not showing on the pdf (printed report).
618350 1021393 NM- Amended C115 not creating for a metered SWD well.
618421 1022196 SWD wells not showing the production info (detail records) when viewing report.

EDT 2003.14 P & E Global Release Notes Page 49 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Defect Case No. Description


619115 1024939 Texas H10 View report lists dates (months) out of order.
619121 1024939 Average tubing pressure calculation is not using all records in the month.
619125 1024939 When all vc_daily_well records have a vol_origin of 'S' the count should show 0.

Patch 2003.4.2.7

Defect Case No. Description


620953 1057502 TDML Activity monitor is very slow and takes all the computer's resources.
621092 1037160 Getting error entering on a usage meter daily template.
621903 1034538 When large numbers of stations as upstream points, some entities not getting allocated.

Patch 2003.4.2.107

Defect Case No. Description


150246 1006529 TX P1/P2 - add capability to handle multiple Commingling Permits on one lease.
159130 1032238 TX P1/P2 would like to filter on Commingling No.
159531 Landmark TX P1/P2 Need casinghead gas on lowest lease # for commingled lease.
162972 869081 TX P1/P2 Edit by Lease should not allow wells for different districts on same lease.
165501 879349 TX P1 SPEC is printed last and it should be first followed by the wells.
170481 1021036 TX P1/P2 reports being merged to the New PR report due out in January 2005.
171588 1027105 TX P1/P2 - Operator/contact info lost when lease ID changed (edited).
180012 935466 TX P1/P2 - lease should not create if all wells end-dated.
619614 1026690 Printed report and EDI are not pulling the Record Unique.
619741 Landmark Printed report and EDI are not pulling the Record Unique.
620572 1030191 TX PR Formation Gas field on the Hard Copy not being populated.
620616 1030458 TX reg beta Create Report Screen Filtering problems.
620623 1030433 Lease code filtering not working on the Select Report screen.
620706 Landmark Lease code field on Lease setup screen not long enough for 8 digit API (used for Pend-
ing reclassed wells).
620712 Landmark Report will not create for reclassified well.
620722 Landmark Field name and lease name not on PR record in edi file.
620754 1030959 Page numbering for TX PR is incorrect.
620850 Landmark Since e-mail is required for edi creation, should be visible in hdr/ftr (pull from contact).
620885 1031188 1st well name mirror imaging on hard copy using Adobe 5.
621072 1032202 Can't save lease setup on SQL Server db.

EDT 2003.14 P & E Global Release Notes Page 50 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Defect Case No. Description


621181 1030888 Beta - Pilot Test - TX Regs - PR Report - Adding Remarks.
621503 1033774 Tow navigation bar not showing lease name on view report screen.
621540 1029709 View Report takes a long time to filter.
622780 Landmark Error on install - files failing to self-register.
622791 1032203 Can't create report in SQL Server db.
622880 1039330 EDI Header record - phone number being truncated.
622989 Landmark TX PR Reclassify screen has a non required field as required.
622991 Landmark TX PR Reclassify screen Effective Date From needs to be a Month/Year drop down.
622992 Landmark TX PR Reclassify Inventory screen Date needs to be a Month/Year drop down.
77239 883189 TX P1/P2 - a well reclassified f/gas to oil need inventory to continue until sold.
84775 926903 WY - request to page break on lease number.
85233 921428 TX P1/P2-Edit by Lease -has own numbering system of leases but TOW requires
unique.
98864 201878 TX P1/P2-to recreate unclosed rpt ALL allocations for all wells need re-approval.

Patch 2003.4.2.108

Defect Case No. Description


141826 919221 TX P1/P2 - Some aspects of the R3 tank exclusion are not working.
622397 1067044 LA - with more than one detail line for transporters/volume first one not on print report.
622993 Landmark TX PR Report needs to attach a sheet if more space is needed for remarks.
623460 1042037 LA R5D missing casinghead gas on printed report.
623689 1048013 H10 By Well setup should have a text field for filling in a default description of
Other.
623735 Landmark The year and month are in the wrong positions in the H10 edi file.
623787 1048206 TX H10 well number not formatted correctly in the edi.
624907 1047324 Negative production not allowed on report; other volumes need to be adjusted.
625146 1055753 When appserver is selected on create screen, list of leases disappears.
625328 1048598 Texas H-10 - 0 (zero) is not getting picked up for minimum casing pressure reading.
625513 1068493 99 should be used as the number of readings for continuously monitored wells.
626573 1056699 VC_REG_RPT_DTL records are not being converted for SQL Server dbs.
626687 1055250 TX PR form must have approval from state.
627118 1060064 Not able to create the PR Texas Report by lease code.
69715 283313 TX P2 Create function does not omit P2 Condensate.

EDT 2003.14 P & E Global Release Notes Page 51 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Patch 2003.4.2.109

Defect Case No. Description


619248 1022178 CA reports Wells changing from producing to injection mid-month need to be on both
production and injection reports.
621923 1035160 New Mexico C115 Oil disposition volumes do not match well production.
624227 1045754 California regulatory report EDI file 2-digit months (Oct, Nov, Dec) are given a leading
zero.
626215 1053004 Average tubing pressure is too low on WAG wells when the well alternates during the
month.
627683 1058098 Lease with multiple commingle permits do not create.
627742 1057691 TX PR Report - Reg data conversion using 2003.4.2.108 patch is not finishing the lease
conversions.
627881 1058733 Record Selection range too large error when trying to view/create PR TX report for sev-
eral leases.
627967 1058917 TX Reg PR is incorrectly adding the Gas Lift meter input volume on the report.
628218 1059105 OGOR-C adjustment code column not showing the code for the largest volume.
628231 1059572 Edi not including the commingling permit numbers.
628288 1058961 Getting one lease per page when printing WY report - makes the report twice as many
pages.
628302 1059712 Some adjustment codes need to show as a negative per state requirements.
628307 1057228 State of NM - inj and disp wells code is doubling on the report.
628427 1059740 Location info & long well name is being cut off on the Form 10 report.
628546 1060176 Viewing Utah Form 10 - selecting by well name, get vc_reg_control does not match
error.
628633 1060318 Wyoming EDI Report missing the last 15 zeros for each row.
628685 1061111 The gas well number is missing from the edi PR record.
628686 1060358 when printing multiple months at once, gas production missing from all but first month.
629010 1061246 Remarks columns allow entry longer than allowed in edi; G4 remark needs even fewer.
629014 1061151 Error occurs when creating the amended report if there were dispositions on original
report.
629470 Landmark NM reports should not create when version is closed and there are no changes.

EDT 2003.14 P & E Global Release Notes Page 52 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Patch 2003.11.0.1

Defect Case No. Description


178392 Landmark CA EDI Production Report fixes for 2003.4.2.104 not in 2003.11.0.
178396 Landmark CA EDI Injection Report fixes for 2003.4.2.104 not in 2003.11.0.
178398 Landmark CA Injection Report-Surface Inj Pressures fixes for 2003.4.2.104 not in 2003.11.0.

Patch 2003.11.0.2

Defect Case No. Description


625301 1050476 Modified Metric run ticket screen pulls up in Daily, but not in Production Accounting
631863 1066268 Compressor - mechanical down reason codes are not correct on HHFO.

Release 2003.14

Defect Case No. Description


180158 935997 Run Time Error and crash when using reselect button between meter and tank run
tickets.
626925 1055812 User is receiving an invalid use of Null error trying to run 2003.11 SP3 against MSDE
db.
631748 1065812 Records created in dw_ tables (for Aries) by TOW PDM table triggers should have
TOW for datasource.
635382 Landmark Need more info on how to set up for metric and non-English US installations.

EDT 2003.14 P & E Global Release Notes Page 53 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Known Problems
The Engineers Desktop 2003.14 has been a significant development effort intended to realize the
strategy of supplying integrated applications to the client that enable engineering workflows. For
each product, changing the application to support a new data model was a significant challenge.

Engineers Desktop 2003.14 is being released with some outstanding issues that are known, but not
thought to prevent users from achieving the efficiency gains provided by these applications. The
following list of issues enables clients to compare observed application behavior against issues
known to Landmark at the time of release. These issues will be addressed in future releases of EDM
together with any additional issues reported by clients.

International Settings for Data Entry Volumes

For our international clients, it is important to change your regional settings so that our applica-
tions accurately display and calculate the data entry volumes, commas, and decimal separators.

Regional Settings:

In most Latin America countries, the decimal symbol is comma (,) and the digit group symbol is
period (.) (ex. 12.500,50). TOW/cs does not handle this setting. Because of this, when language is
set to Spanish (ex. Spanish (Venezuela)), the Decimal Symbol has to be changed to period (.) and
Digit Group Symbol to comma (,). If the settings are not changed, some of the fields calculated by
TOW/cs are incorrect.

To Change the Regional Setting

To change the regional settings:


1. Click Start > Settings > Control Panel > Regional and Language Options (for XP users) or
Regional Settings (for Windows 2000 users).

2. On the Regional Options tab, click the drop down menu arrow and scroll the menu and
highlight your language/country.

3. Click OK.

4. Click the Customize button.

5. Change the Decimal symbol to a period (.) and the Digit grouping symbol to a comma (,).

6. Click OK.

EDT 2003.14 P & E Global Release Notes Page 54 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Oracle client setup:

TOW/cs does not recognize decimal places if the decimal symbol is a comma and the digit group
symbol is a period at the Oracle client level.

To Change the Oracle Client Setup

To Change the Oracle Client Setup:


1. Set NLS_LANG to AMERICAN_AMERICA (in this way NLS_NUMERIC_CHARACTERS
= ., (period, comma) by default)

Or

2. Set NLS_LANG to SPANISH_SPAIN, added the NLS_NUMERIC_CHARACTERS


parameter to the registry, and entered ., (period, comma) as value (in this way, the value
defines implicitly by the territory part of the NLS_LANG variable gets overridden).

Please Note:
NLS_LANG = LANGUAGE_TERRITORY.CHARACTERSET TERRITORY specifies:
monetary and numeric formats,
territory and conventions for calculating week and day numbers

This applies when NLS_LANG = SPANISH_SPAIN, NLS_NUMERIC_CHARACTERS = ,.


(comma, period).

and

NLS_LANG = AMERICAN_AMERICA, NLS_NUMERIC_CHARACTERS = ., (period,


comma)

The NLS_NUMERIC_CHARACTERS parameter specifies the decimal character and grouping


separator, overriding those defined implicitly by NLS_TERRITORY. The group separator is the
character that separates integer groups (that is, the thousands, millions, billions, etc.). The decimal
character separates the integer and decimal parts of a number.
The characters are specified in the following format:
NLS_NUMERIC_CHARACTERS = "<decimal_character><group_separator>"

In other words, if NLS_NUMERIC_CHARACTERS = ,. (comma, period), then the decimal char-


acter is a comma, and the group separator is a period.

EDT 2003.14 P & E Global Release Notes Page 55 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

ARIES

Defect Case No. Description


624338 1046282 There is a problem populating S750 and S751 in the monthly table with ABDN capital
costs.
628338 1059562 The MUL of the ratio dependant phase is not correct with CUM correlation.
630176 Landmark MultiGraph displays a hidden message when Notes are open in MultiGraph and Project
Manager and the user goes to next property. The user must tab to the message so that
he can view it and respond.
632726 Landmark The Forecast Upper Range Line becomes stuck after moving it with the keyboard. This
problem only occurs on walk with arrow key and Missing data points. Workaround is to
use Shift Arrow (move 12 Steps at a time) or Mouse to Drag the marker to required
spot.
633165 Landmark User gets a run-time error when editing an .rsi file that has a long path with spaces.

ARIES/RMS

Defect Case No. Description


178335 Landmark RMS EIA: The RMS_EIA table only updates correctly if the next year is booked.

ARIES International

Defect Case No. Description


635409 Landmark ARIES International gets an error for MDATA lines. Caused by a line shifted right due
to comma in mdata_field title. For a workaround, do not include commas in the
MDATA fields.
699720 Landmark The International tab does not check to verify that the parameter name matches the
items defined in the Well script.

Desktop Navigator

Defect Case No. Description


Known Landmark TOW/cs User rights are not working correctly and numerous defects have been logged
Issue against this functionality.
Known Landmark The Company template will not accept all data entry formats of a telephone number.
Issue The correct format for telephone number is
(123) 456-7890. The extension, spaces, and hyphens are optional.
617596 Landmark There is inconsistency in the Well Properties dialog during creation, as well as when it
is viewed.

EDT 2003.14 P & E Global Release Notes Page 56 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Defect Case No. Description


617696 Landmark When creating a new entity, the online help should be context sensitive to the type of
entity.
617697 Landmark The online help lacks content regarding Locked Password and Company Locked
Password.
621759 Landmark Object reference is not set to an instance of an object error messages when working
with reports.
622751 Landmark When OpenWorks is locked, Projects, Sites, Wells, Wellbores, and Completions can be
unlocked without passwords.
631803 Landmark The Intervals box is missing from the Data Range page.
632606 Landmark Edit > Find command does not work.
698478 Landmark Latitude and Longitude values get reset when leaving the control.
698928 Landmark Desktop Navigator may throw stack trace for incorrect queries.
698932 Landmark Enumeration operation may not execute while adding sections in the Template
Manager.

EDT 2003.14 P & E Global Release Notes Page 57 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

DSS

Defect Case No. Description


621235 1032774 When the user cancels the editing of a group membership, the members disappear from
the screen.
Known Landmark Error Received when creating Station or Economic groups: When creating Station or
Issue Economic groups, selecting Assign from selected member or Calculate the location at
the center of the grouping results in an error message. This error occurs because neither
the Station or Economic groups have location coordinates at this time. Click the OK
button to continue the creation process with the default coordinates of Long - 0, Lat - 0.
Known Landmark Error received when creating groups: When creating groups for the first time in a
Issue project converted from a previous version, you may receive an error message. To fix
this problem, you have two options. Either update the column properties for the table
mapped to the GroupMaster Table Map Option, or change the Project Options > Join
Types > Setup page to set the GROUP_ID join type automatically.

OpenWire Production

Defect Case No. Description


613624 Landmark E_MAXEXCEEDED exception displays while moving OPCHDA_END Aggregate
from OPC Server with RI of one minute for a one year period.
616748 Landmark When a large number of instruments are present, and the user has pulled in the
instruments; they show up again in the Instrument Panel list.
616937 Landmark Navigating from a third un-saved pipeline to an already started pipeline 1 causes an un-
handled exception.
616992 Landmark An invalid EDM connection in pipeline start state does not show stop state. Also,
switching back to valid EDM connection does not automatically start the pipeline.
617760 Landmark OWP Pipeline Manager crashes at launch for non-administrator users on Windows
2000.

TOW/cs

Defect Case No. Description


175905 Landmark Using the calculation method as Manual does not populate the columns.
176132 Landmark R_270 report dates are displaying twice.
176809 Landmark Changing the state code, then tabbing and changing the county code causes the state
code to change.
622433 1037397 The International Decimal Symbol and Digit Group Symbol settings can cause
incorrect calculations.
623509 1042288 User is not able to cross-reference wells in TOW/cs and OpenWorks.
624800 1048494 User is unable to save a new liquid analysis when using the Add Record button.

EDT 2003.14 P & E Global Release Notes Page 58 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Defect Case No. Description


625592 1051597 A Subscript Out of Range error generates when inserting 16 or more production
potential values.
633185 1064797 There is an intermittent problem when setting up new completions or equipment. Can
save with zero SK or saves completely.
698436 1074672 LA Regs - Oil Sales Volume is not appearing on the report.
698983 1080743 The Battery Summary Report (R_230) does not retrieve data if the date format is dd/
mm/yyyy and the from date is the 12th or 13th.
700155 1076829 The Sum-Multiple Tanks Current function does not sum all the tickets entered on the
same day.
700748 1078293 The SUM-TANK VOL # DAYS BACK function is carrying forward the last value if
DAYS BACK is set to 0 and the user is running allocations for several days.
700881 1080141 PDM_PRODUCTION_HDR not getting the X,Y values.
700883 1080141 Plot_X and Plot_Y columns are not large enough for values used internationally.

EDT 2003.14 P & E Global Release Notes Page 59 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Running Production & Economics Applications


Landmark recommends accessing and running the Production and Economics applications through
the Desktop Navigator. All of the applications are window-based, and can be opened on your
desktop simultaneously. See the Desktop Navigator online help for details.

Accessing the Desktop Navigator

To access the Desktop Navigator:

1. Click Start > Programs > Landmark Engineers Desktop 2003.14 > Desktop Navigator.

2. Login using with your Username and Password.

3. Click Edit to navigate to your database.

4. Click Login

The Desktop Navigator will be displayed.

You may also access Production & Economics applications from Start > Programs > Landmark
Engineers Desktop 2003.14, or by clicking the application icon on your desktop. Note, however,
that TOW does not have an icon on the desktopyou can access the TOW modules by clicking
Start > Programs > Landmark Engineers Desktop 2003.14 > TOWcs, and selecting the
desired module.

If you want to run EPS (Edinburgh Petroleum Services) WellFlo

The WellFlo application is located on CD 5, under the \Petroleum Engineering Utilities folder.

Shortcut icons for TOW are not placed on the desktop.

This is expected behavior. Shortcut icons to launch TOW/cs applications are not placed on the Desktop
during the install, even if you selected Yes to the question Do you want to place shortcuts on your
Desktop?. To launch TOW/cs applications, select the application from the
Start > Landmark Engineers Desktop 2003.14 > TOWcs menu.

EDT 2003.14 P & E Global Release Notes Page 60 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Contacting Support
Landmark operates Technical Assistance Centers (TACs) in Houston, Texas, Leatherhead, UK
and Perth, Australia. Additional support is provided through district support offices around the
world. If problems cannot be resolved at the district level, our escalation team is called to resolve
your incidents quickly.

Support information is always available on the Landmark Graphics Support internet page located
at:- http:\\www.lgc.com\customersupport.

Technical Assistance Centers


North America 713-839-2200 (Houston, TX, USA)
7:30 am - 5:30 pm Central Standard Time Toll Free 1-877-435-7542
Monday - Friday, excluding holidays (1-877-HELP-LGC)
Fax: 713-839-2168 (Houston, TX)
After Hours Support: Fax: 512-292-2200, 2220 (Austin, TX)
24 hour support is offered only to ARIES, DIMS & Fax: 907-275-2655 (Anchorage, AK)
OpenWells subscribing customers. Includes weekends Fax: 303-796-0807 (Denver, CO)
and holidays. Fax: 403-262-1929 (Calgary, Canada)
Contact Toll Free: 1-877-435-7542
Email: support@lgc.com

Latin America 1-713-839-3405 (Houston, TX, USA)


(Spanish, Portuguese, English) Fax: 713-839-3646
7:00 am - 5:00 pm Central Standard Time Email: soporte@lgc.com
Local normal business hours
Toll Free from:
After Hours Support: Argentina: 0800-800-5263
24 hour support is offered only to DIMS & OpenWells Brazil: 0800-891-0837
subscribing customers. Includes weekends and Chile: 800-201-898
holidays. Colombia: 01800-915-4743
Contact: 1-713-839-3405 Mexico: 001-888-438-1296
Peru: 0800-51634
Trinidad: 1-888-438-1296
Venezuela: 0-800-526-3627

Toll Free from local area:


Ecuador (Quito) (02)226-1908

Europe, Africa, Middle East 44-1372-868686 (Leatherhead, UK)


8:00 am - 5:30 pm Local Time Fax: 44-1372-868601 (Leatherhead, UK)
Monday - Friday, excluding holidays Fax: 44-1224-723260 (Aberdeen, UK)
Email: eame_helpdesk@lgc.com
After Hours Support:
24 hour support is offered only to DIMS & OpenWells
subscribing customers. Includes weekends and
holidays.
Contact: 44-1224-763200 (Aberdeen, UK)

EDT 2003.14 P & E Global Release Notes Page 61 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Asia, Pacific 61-8-9481-4488 (Perth, Australia)


8:00 am - 5:00 pm Local Time Toll-free 1-800-448-488
Monday-Friday, excluding holidays Fax: 61-8-9481-1580
Email: apsupport@lgc.com
After Hours Support:
24 hour support is offered only to DIMS & OpenWells Toll-Free from:
subscribing customers. Includes weekends and China: 10-800-6100-253
holidays. Indonesia: 001-803-61284
Contact: 61-8-9427-7339 Japan: 00531-61-0021
Malaysia 1800-803-687
New Zealand 0800-400-555
Philippines 1800-1611-0207
South Korea 00308-61-0046
Taiwan 00801-61-1350
Thailand 001-800-611-2784

Toll Free from local area:


Vietnam: 84-8-9101910

District Support Offices


Algiers, Algeria 21-337-7239
8:30 an - 4:30 pm Local Time Email: eame_helpdesk@lgc.com
Saturday - Wednesday, excluding holidays

Republic de Angola (Luanda) 1-817-493-5900


8:00 am - 5:00 pm Local Time Fax: 1-817-493-560
Monday - Friday, excluding holidays Email: eame_helpdesk@lgc.com

Argentina (Buenos Aires) 54-11-4312-8411


9:00 am - 6:00 pm Toll Free 0800-800-5263
Local normal business hours Fax: 54-11-4311-9566
Email: soporte@lgc.com

Australia (Perth) 61-8-9481-4488


8:00 am - 5:00 pm Local Time Toll Free 1800-448-488
Monday - Friday, excluding holidays Fax: 61-8-9481-1580
Email: apsupport@lgc.com

Brazil (Rio de Janeiro) 55-21-3974-4000 or


8:00 am - 5:30 pm Toll Free 0800-891-0837
Local normal business hours Fax: 55-21-3974-4002
Email: soporte@lgc.com

Brunei (Bandar Seri Bagawan) 67-3-233-5319


8:30 am - 5:30 pm Local Time Email: apsupport@lgc.com
Monday - Friday, excluding holidays

EDT 2003.14 P & E Global Release Notes Page 62 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Canada (Calgary) Toll Free 1-877-435-7542


7:30 am - 5:30 pm Mountain Time (1-877-HELP-LGC)
Monday-Friday, excluding holidays Fax: 403-262-1929 (Calgary, Canada)
Fax: 713-830-2168 (Houston, TX)
Email: support@lgc.com

Chile (TAO TAC, Houston, Texas) Toll Free 800-201-898


Local normal business hours Fax: 1-713-839-3646
Email: soporte@lgc.com

Colombia (Bogota) 57-1-326-4000-57-1-326-6710


8:00 am - 5:00 pm Toll Free 01800-915-4743
Local normal business hours Fax: 57-1-326-6717
Email: soporte@lgc.com

Ecuador (Quito) 59-32-226-1844 (ext 146)


8:00 am - 5:00 pm Toll Free from Quito (02)226-1908
Local normal business hours Fax: 59-32-226-2590
Email: soporte@lgc.com

Egypt (Cairo) 20-2-517-3095


8:00 am - 4:00 pm Local Time (ask for Landmark Technical Support)
Saturday - Wednesday, excluding holidays Email: eame_helpdesk@lgc.com

India (New Delhi) 91-11-622-1885


9:00 am - 5:30 pm Local Time (c/o Samit Enterprises)
Local Business Days, excluding holidays Fax: 91-11-647-9246
Email:

Indonesia (Jakarta) 62-21-3003-9039 or


7:30 am - 4:30 pm Local Time Toll Free 011-803-61284
Monday - Friday, excluding holidays Fax: 62-21-3003-9088
Email: apsupport@lgc.com

Malaysia (Kuala Lumpur) 603-2164-1121 or


8:30 am - 5:30 pm Local Time Toll Free 1800-803-687
Monday - Friday, excluding holidays Fax: 603-2164-1135
Email: apsupport@lgc.com

Mexico (Reynosa) 52-555-208-3533


8:00 am - 6:00 pm 52-555-208-3868
Local normal business hours Toll Free 001-888-438-1296
Local Office Fax: 52-555-514-7646
Support Fax: 1-713-839-3646
Email: soporte@lgc.com

EDT 2003.14 P & E Global Release Notes Page 63 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

New Zealand (New Plymouth) 61-6-755-2318


8:00 am - 5:00 pm Local Time Toll Free 0800-400-555
Monday - Friday, excluding holidays Fax: 64-6-755-2407
Email: apsupport@lgc.com

Nigeria (Lagos) 234-1-262-0765


8:00 am - 5:00 pm Local Time (ask for Landmark Technical Support)
Monday - Friday, excluding holidays Fax: 234-1-262-0769
Email: eame_helpdesk@lgc.com

People's Republic of China (Beijing) 86-10-8486-4501


9:00 am - 5:30 pm Local Time Toll Free 10-800-6100-253
Monday - Friday, excluding holidays Other Phone: 10-800-810-0209
Fac: 86-10-8486-4819
Email bjsupport@lgc.com
or apsupport@lgc.com

Peru (Lima) Toll Free 0800-51634


Local normal business hours Fax: 1-713-830-3646
Email: soporte@lgc.com

Russia (Moscow) 7-095-755-8300


7:00 am - 5:00 pm Local Time (ask for Landmark Technical Support)
Local Business Days, excluding holidays Fax: 7-095-755-8301
Email: eame_helpdesk@lgc.com

Taiwan Toll Free 00801-61-1350


8:30 am - 5:30 pm Local Time Fax:
Monday-Friday, excluding holidays Email: apsupport@lgc.com

Thailand (Bangkok) 66-2-278-8100


8:00 am - 5:00pm Local Time Toll Free 001-800-611-2784
Monday - Friday, excluding holidays Fax: 66-2-278-8199
Email: apsupport@lgc.com

Trinidad & Tobago (TAO TAC, Houston, TX) Toll Free: 1-888-438-1296
7:00 am - 5:00 pm Central Standard Time Fax: 1-713-839-3646
(Houston, TX) Email: soporte@lgc.com
Local normal business hours

United Arab Emirates (Dubai) +971-4-3313142


7:00 am - 5:00 pm Local Time (ask for Landmark Technical Support)
Local Business Days, excluding holidays Fax: +971-4-3315837
Email: gulf_support@lgc.com

EDT 2003.14 P & E Global Release Notes Page 64 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Venezuela (Caracas) 58-212-953-0774


8:00 am - 5:00 pm Toll Free 0-800-526-3627
Local normal business hours Fax: 58-212-952-3845
Email: soporte@lgc.com

Vietnam (Ho Chi Minh City) 84-8-910-1901


8:00 am - 5:00 pm Local Time Fax: 84-8-910-1902
Monday - Friday, excluding holidays Email: apsupport@lgc.com

Helpful internet links are shown below.

Name Website Address


Landmark Graphics home page http://www.lgc.com
Landmark Graphics FTP Site ftp://ftp.lgc.com
Oracle home page http://www.oracle.com
FLEXlm license management software http://www.macrovision.com/products/
home page legacy_products/flexlm/index.html
Microsoft SQL Server home page http://www.microsoft.com/sql/default.asp
Adobe Acrobat Reader http://www.adobe.com
Microsoft MSDE http://www.microsoft.com/sql/default.asp

EDT 2003.14 P & E Global Release Notes Page 65 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Appendix A: Roles and Privileges

Role Privileges by Table

TABLE_NAME PRIVILEGE

ARBATCHMACROS DELETE
ARBATCHMACROS INSERT
ARBATCHMACROS SELECT
ARBATCHMACROS UPDATE
ARBKTITLES DELETE
ARBKTITLES INSERT
ARBKTITLES SELECT
ARBKTITLES UPDATE
ARCURVE DELETE
ARCURVE INSERT
ARCURVE SELECT
ARCURVE UPDATE
ARDBSLIST DELETE
ARDBSLIST INSERT
ARDBSLIST SELECT
ARDBSLIST UPDATE
ARECOPHASE DELETE
ARECOPHASE INSERT
ARECOPHASE SELECT
ARECOPHASE UPDATE
ARECOSTRM DELETE
ARECOSTRM INSERT
ARECOSTRM SELECT
ARECOSTRM UPDATE
ARENDDATE DELETE
ARENDDATE INSERT
ARENDDATE SELECT
ARENDDATE UPDATE
ARFILTER DELETE

EDT 2003.14 P & E Global Release Notes Page 66 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

ARFILTER INSERT
ARFILTER SELECT
ARFILTER UPDATE
ARFILTERS DELETE
ARFILTERS INSERT
ARFILTERS SELECT
ARFILTERS UPDATE
ARGRAPH DELETE
ARGRAPH INSERT
ARGRAPH SELECT
ARGRAPH UPDATE
ARGRAPHCURVE DELETE
ARGRAPHCURVE INSERT
ARGRAPHCURVE SELECT
ARGRAPHCURVE UPDATE
ARGROUPTABLE DELETE
ARGROUPTABLE INSERT
ARGROUPTABLE SELECT
ARGROUPTABLE UPDATE
ARGROUPTEST DELETE
ARGROUPTEST INSERT
ARGROUPTEST SELECT
ARGROUPTEST UPDATE
ARGROUPVW SELECT
ARGROUPVW UPDATE
ARIESSCHEMAVERSION DELETE
ARIESSCHEMAVERSION INSERT
ARIESSCHEMAVERSION SELECT
ARIESSCHEMAVERSION UPDATE
ARLOCK DELETE
ARLOCK INSERT
ARLOCK SELECT
ARLOCK UPDATE
ARLOOKUP DELETE
ARLOOKUP INSERT
ARLOOKUP SELECT
ARLOOKUP UPDATE
ARPLOT DELETE
ARPLOT INSERT
ARPLOT SELECT

EDT 2003.14 P & E Global Release Notes Page 67 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

ARPLOT UPDATE
ARPROJECT DELETE
ARPROJECT INSERT
ARPROJECT SELECT
ARPROJECT UPDATE
ARPROJLIST DELETE
ARPROJLIST INSERT
ARPROJLIST SELECT
ARPROJLIST UPDATE
ARPZCALCINS DELETE
ARPZCALCINS INSERT
ARPZCALCINS SELECT
ARPZCALCINS UPDATE
ARREPORTFORMAT DELETE
ARREPORTFORMAT INSERT
ARREPORTFORMAT SELECT
ARREPORTFORMAT UPDATE
ARSELFILTERS DELETE
ARSELFILTERS INSERT
ARSELFILTERS SELECT
ARSELFILTERS UPDATE
ARSORTFILTERS DELETE
ARSORTFILTERS INSERT
ARSORTFILTERS SELECT
ARSORTFILTERS UPDATE
ARSORTTITLE DELETE
ARSORTTITLE INSERT
ARSORTTITLE SELECT
ARSORTTITLE UPDATE
ARSTREAM DELETE
ARSTREAM INSERT
ARSTREAM SELECT
ARSTREAM UPDATE
ARSUMPROPS DELETE
ARSUMPROPS INSERT
ARSUMPROPS SELECT
ARSUMPROPS UPDATE
ARSYSCOL DELETE
ARSYSCOL INSERT
ARSYSCOL SELECT
ARSYSCOL UPDATE

EDT 2003.14 P & E Global Release Notes Page 68 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

ARSYSTBL DELETE
ARSYSTBL INSERT
ARSYSTBL SELECT
ARSYSTBL UPDATE
ARTBLSETS DELETE
ARTBLSETS INSERT
ARTBLSETS SELECT
ARTBLSETS UPDATE
ARTREND DELETE
ARTREND INSERT
ARTREND SELECT
ARTREND UPDATE
ARUNITS DELETE
ARUNITS INSERT
ARUNITS SELECT
ARUNITS UPDATE
ARUNITTYPES DELETE
ARUNITTYPES INSERT
ARUNITTYPES SELECT
ARUNITTYPES UPDATE
AR_ECONOMIC DELETE
AR_ECONOMIC INSERT
AR_ECONOMIC SELECT
AR_ECONOMIC UPDATE
AR_ECON_SUMMARY DELETE
AR_ECON_SUMMARY INSERT
AR_ECON_SUMMARY SELECT
AR_ECON_SUMMARY UPDATE
AR_NOTES DELETE
AR_NOTES INSERT
AR_NOTES SELECT
AR_NOTES UPDATE
AR_RATIO DELETE
AR_RATIO INSERT
AR_RATIO SELECT
AR_RATIO UPDATE
AR_RESERVE DELETE
AR_RESERVE INSERT
AR_RESERVE SELECT
AR_RESERVE UPDATE
AR_SETUP DELETE

EDT 2003.14 P & E Global Release Notes Page 69 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

AR_SETUP INSERT
AR_SETUP SELECT
AR_SETUP UPDATE
AR_SETUPDATA DELETE
AR_SETUPDATA INSERT
AR_SETUPDATA SELECT
AR_SETUPDATA UPDATE
AR_TEST DELETE
AR_TEST INSERT
AR_TEST SELECT
AR_TEST UPDATE
AR_VIPDATA DELETE
AR_VIPDATA INSERT
AR_VIPDATA SELECT
AR_VIPDATA UPDATE
AR_WELL DELETE
AR_WELL INSERT
AR_WELL SELECT
AR_WELL UPDATE
DW_DAILY_INJECTION DELETE
DW_DAILY_INJECTION INSERT
DW_DAILY_INJECTION SELECT
DW_DAILY_INJECTION UPDATE
DW_DAILY_PROD DELETE
DW_DAILY_PROD INSERT
DW_DAILY_PROD SELECT
DW_DAILY_PROD UPDATE
DW_ECON_DETAIL DELETE
DW_ECON_DETAIL INSERT
DW_ECON_DETAIL SELECT
DW_ECON_DETAIL UPDATE
DW_ECON_MONTHLY DELETE
DW_ECON_MONTHLY INSERT
DW_ECON_MONTHLY SELECT
DW_ECON_MONTHLY UPDATE
DW_ECON_ONELINE DELETE
DW_ECON_ONELINE INSERT
DW_ECON_ONELINE SELECT
DW_ECON_ONELINE UPDATE
DW_ECON_OWNER DELETE
DW_ECON_OWNER INSERT

EDT 2003.14 P & E Global Release Notes Page 70 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

DW_ECON_OWNER SELECT
DW_ECON_OWNER UPDATE
DW_ECON_PZFCST DELETE
DW_ECON_PZFCST INSERT
DW_ECON_PZFCST SELECT
DW_ECON_PZFCST UPDATE
DW_MONTHLY_INJECTION DELETE
DW_MONTHLY_INJECTION INSERT
DW_MONTHLY_INJECTION SELECT
DW_MONTHLY_INJECTION UPDATE
DW_MONTHLY_PROD DELETE
DW_MONTHLY_PROD INSERT
DW_MONTHLY_PROD SELECT
DW_MONTHLY_PROD UPDATE
DW_PROD_CUMS DELETE
DW_PROD_CUMS INSERT
DW_PROD_CUMS SELECT
DW_PROD_CUMS UPDATE
ECON_EXTENSION DELETE
ECON_EXTENSION INSERT
ECON_EXTENSION SELECT
ECON_EXTENSION UPDATE
ECON_EXTENSION_UEXT DELETE
ECON_EXTENSION_UEXT INSERT
ECON_EXTENSION_UEXT SELECT
ECON_EXTENSION_UEXT UPDATE
ECON_EXTENSION_UEXT_V SELECT
ECON_EXTENSION_UEXT_V UPDATE
ECON_PROPERTY DELETE
ECON_PROPERTY INSERT
ECON_PROPERTY SELECT
ECON_PROPERTY UPDATE
EDM_DATA_SOURCE SELECT
EDM_GROUP DELETE
EDM_GROUP INSERT
EDM_GROUP SELECT
EDM_GROUP UPDATE
EDM_GROUP_MEMBERS DELETE
EDM_GROUP_MEMBERS INSERT
EDM_GROUP_MEMBERS SELECT
EDM_GROUP_MEMBERS UPDATE

EDT 2003.14 P & E Global Release Notes Page 71 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

EDM_SCENARIO DELETE
EDM_SCENARIO INSERT
EDM_SCENARIO SELECT
EDM_SCENARIO UPDATE
EDM_SCENARIO_DTL DELETE
EDM_SCENARIO_DTL INSERT
EDM_SCENARIO_DTL SELECT
EDM_SCENARIO_DTL UPDATE
MD_PK_PDEN_TYPE SELECT
MD_SYS_DB_VERSION SELECT
PEMV_ARIES_DW_DD SELECT
PEMV_ARIES_DW_MM SELECT
PEMV_ECON_PICKLIST SELECT
RMS_EIAHEADER DELETE
RMS_EIAHEADER INSERT
RMS_EIAHEADER SELECT
RMS_EIAHEADER UPDATE

EDT 2003.14 P & E Global Release Notes Page 72 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Desktop Roles and Privileges

TABLE_NAME PRIVILEGE

ARECOPHASE SELECT
ARSYSTBL SELECT
CD_ATTACHMENT DELETE
CD_ATTACHMENT INSERT
CD_ATTACHMENT SELECT
CD_ATTACHMENT UPDATE
CD_ATTACHMENT_JOURNAL DELETE
CD_ATTACHMENT_JOURNAL INSERT
CD_ATTACHMENT_JOURNAL SELECT
CD_ATTACHMENT_JOURNAL UPDATE
CD_COMPLETION INSERT
CD_COMPLETION SELECT
CD_COMPLETION UPDATE
CD_POLICY INSERT
CD_POLICY SELECT
CD_POLICY UPDATE
CD_PROJECT INSERT
CD_PROJECT SELECT
CD_PROJECT UPDATE
CD_SITE INSERT
CD_SITE SELECT
CD_SITE UPDATE
CD_WELL INSERT
CD_WELL SELECT
CD_WELL UPDATE
CD_WELLBORE INSERT
CD_WELLBORE SELECT
CD_WELLBORE UPDATE
ECON_PROPERTY INSERT

EDT 2003.14 P & E Global Release Notes Page 73 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

ECON_PROPERTY SELECT
ECON_PROPERTY UPDATE
EDM_GROUP INSERT
EDM_GROUP SELECT
EDM_GROUP UPDATE
EDM_GROUP_MEMBERS INSERT
EDM_GROUP_MEMBERS SELECT
EDM_GROUP_MEMBERS UPDATE
MD_DESKTOP_FORMATS INSERT
MD_DESKTOP_FORMATS SELECT
MD_DESKTOP_FORMATS UPDATE
MD_HIERARCHY_ENTITY_BINDING DELETE
MD_HIERARCHY_ENTITY_BINDING INSERT
MD_HIERARCHY_ENTITY_BINDING SELECT
MD_HIERARCHY_ENTITY_BINDING UPDATE
MD_HIERARCHY_LEVEL_OBJECTS DELETE
MD_HIERARCHY_LEVEL_OBJECTS INSERT
MD_HIERARCHY_LEVEL_OBJECTS SELECT
MD_HIERARCHY_LEVEL_OBJECTS UPDATE
MD_HIERARCHY_SCHEMES DELETE
MD_HIERARCHY_SCHEMES INSERT
MD_HIERARCHY_SCHEMES SELECT
MD_HIERARCHY_SCHEMES UPDATE
MD_HIERARCHY_SCHEME_LEVELS DELETE
MD_HIERARCHY_SCHEME_LEVELS INSERT
MD_HIERARCHY_SCHEME_LEVELS SELECT
MD_HIERARCHY_SCHEME_LEVELS UPDATE
MD_HIERARCHY_SCHEME_TYPES SELECT
MD_SITE_APP_ACTION SELECT
MD_SITE_APP_ACTION_OWNER SELECT
MD_SITE_TIGHT_GROUP SELECT
MD_SITE_TIGHT_GROUP_MEMBER SELECT
MD_SITE_USER SELECT
MD_SYS_DB_VERSION SELECT
MD_SYS_FIELD_DEF SELECT
MD_SYS_TABLE_DEF SELECT
VC_SK_CONTROL SELECT
VC_SK_CONTROL UPDATE
VC_STATE_PROV SELECT
VC_TOW_REF SELECT
VC_WELLCOMP INSERT
VC_WELLCOMP SELECT
VC_WELLCOMP UPDATE

EDT 2003.14 P & E Global Release Notes Page 74 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

DSS Roles and Privileges

TABLE_NAME PRIVILEGE

CD_COMPLETION SELECT
CD_WELL SELECT
DSS_ANNOTATIONS DELETE
DSS_ANNOTATIONS INSERT
DSS_ANNOTATIONS SELECT
DSS_ANNOTATIONS UPDATE
DSS_ANNOT_LEGEND DELETE
DSS_ANNOT_LEGEND INSERT
DSS_ANNOT_LEGEND SELECT
DSS_ANNOT_LEGEND UPDATE
ECON_PROPERTY SELECT
EDM_DOWNHOLE_EQUIPMENT SELECT
EDM_GROUP DELETE
EDM_GROUP INSERT
EDM_GROUP SELECT
EDM_GROUP UPDATE
EDM_GROUP_MEMBERS DELETE
EDM_GROUP_MEMBERS INSERT
EDM_GROUP_MEMBERS SELECT
EDM_GROUP_MEMBERS UPDATE
EDM_SCENARIO SELECT
PEMV_ACCT_COMPLETION SELECT
PEMV_DEFINITIVE_SURVEY_STATION SELECT
PEMV_WELLBORE SELECT
PEMV_WELLBORE_ZONE SELECT
PEMV_WELL_WORK_OVER SELECT
VC_EQUIPMENT SELECT

EDT 2003.14 P & E Global Release Notes Page 75 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

RMS Roles and Privileges

TABLE_NAME PRIVILEGE

RMS_BKDELTA DELETE
RMS_BKDELTA INSERT
RMS_BKDELTA SELECT
RMS_BKDELTA UPDATE
RMS_BKMEMO DELETE
RMS_BKMEMO INSERT
RMS_BKMEMO SELECT
RMS_BKMEMO UPDATE
RMS_BKPROD DELETE
RMS_BKPROD INSERT
RMS_BKPROD SELECT
RMS_BKPROD UPDATE
RMS_CHANGE DELETE
RMS_CHANGE INSERT
RMS_CHANGE SELECT
RMS_CHANGE UPDATE
RMS_DEFMEMO DELETE
RMS_DEFMEMO INSERT
RMS_DEFMEMO SELECT
RMS_DEFMEMO UPDATE
RMS_EIA DELETE
RMS_EIA INSERT
RMS_EIA SELECT
RMS_EIA UPDATE
RMS_EIAHEADER DELETE
RMS_EIAHEADER INSERT
RMS_EIAHEADER SELECT
RMS_EIAHEADER UPDATE
RMS_EIAID DELETE

EDT 2003.14 P & E Global Release Notes Page 76 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

RMS_EIAID INSERT
RMS_EIAID SELECT
RMS_EIAID UPDATE
RMS_NONBKMEMO DELETE
RMS_NONBKMEMO INSERT
RMS_NONBKMEMO SELECT
RMS_NONBKMEMO UPDATE
RMS_PHASE DELETE
RMS_PHASE INSERT
RMS_PHASE SELECT
RMS_PHASE UPDATE
RMS_REPORT DELETE
RMS_REPORT INSERT
RMS_REPORT SELECT
RMS_REPORT UPDATE
RMS_RESCAT DELETE
RMS_RESCAT INSERT
RMS_RESCAT SELECT
RMS_RESCAT UPDATE
RMS_RESERVES DELETE
RMS_RESERVES INSERT
RMS_RESERVES SELECT
RMS_RESERVES UPDATE
RMS_RPT DELETE
RMS_RPT INSERT
RMS_RPT SELECT
RMS_RPT UPDATE
RMS_RPTHDR DELETE
RMS_RPTHDR INSERT
RMS_RPTHDR SELECT
RMS_RPTHDR UPDATE
RMS_SCENARIO DELETE
RMS_SCENARIO INSERT
RMS_SCENARIO SELECT
RMS_SCENARIO UPDATE
RMS_SECURITY DELETE
RMS_SECURITY INSERT
RMS_SECURITY SELECT
RMS_SECURITY UPDATE

EDT 2003.14 P & E Global Release Notes Page 77 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

VCR_Inquiry Roles and Privileges

TABLE_NAME PRIVILEGE

ARBATCHMACROS SELECT
ARBKTITLES SELECT
ARCURVE SELECT
ARDBSLIST SELECT
ARECOPHASE SELECT
ARECOSTRM SELECT
ARENDDATE SELECT
ARFILTER SELECT
ARFILTERS SELECT
ARGRAPH SELECT
ARGRAPHCURVE SELECT
ARGROUPTABLE SELECT
ARGROUPTEST SELECT
ARIESSCHEMAVERSION SELECT
ARLOCK SELECT
ARLOOKUP SELECT
ARPLOT SELECT
ARPROJECT SELECT
ARPROJLIST SELECT
ARPZCALCINS SELECT
ARREPORTFORMAT SELECT
ARSELFILTERS SELECT
ARSORTFILTERS SELECT
ARSORTTITLE SELECT
ARSTREAM SELECT
ARSUMPROPS SELECT
ARSYSCOL SELECT
ARSYSTBL SELECT
ARTBLSETS SELECT
ARTREND SELECT
ARUNITS SELECT
ARUNITTYPES SELECT
AR_ECONOMIC SELECT
AR_ECON_SUMMARY SELECT
AR_NOTES SELECT
AR_RATIO SELECT
AR_RESERVE SELECT
AR_SETUP SELECT
AR_SETUPDATA SELECT
AR_TEST SELECT
AR_VIPDATA SELECT
AR_WELL SELECT
CD_ATTACHMENT SELECT
CD_ATTACHMENT_JOURNAL SELECT

EDT 2003.14 P & E Global Release Notes Page 78 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

CD_COMPLETION SELECT
CD_DATUM SELECT
CD_DEFINITIVE_SURVEY_HEADER SELECT
CD_DEFINITIVE_SURVEY_STATION SELECT
CD_EXTERNAL_CONNECTION SELECT
CD_LITHOLOGY_CLASS SELECT
CD_LOCATION SELECT
CD_LOCATION_CARTER SELECT
CD_LOCATION_CONGRESS SELECT
CD_LOCATION_DLS SELECT
CD_LOCATION_FPS SELECT
CD_LOCATION_NARRATIVE SELECT
CD_LOCATION_NE SELECT
CD_LOCATION_NORTHSEA SELECT
CD_LOCATION_NTS SELECT
CD_LOCATION_OCS SELECT
CD_LOCATION_OHIO SELECT
CD_LOCATION_TEXAS SELECT
CD_OPENING_STATUS SELECT
CD_POLICY SELECT
CD_PRESSURE_AOF SELECT
CD_PRESSURE_AOF_FLOW SELECT
CD_PRESSURE_AWS SELECT
CD_PRESSURE_AWS_AC SELECT
CD_PRESSURE_SG SELECT
CD_PRESSURE_SG_GRADIENT SELECT
CD_PRESSURE_SURVEY SELECT
CD_PRESSURE_TRG SELECT
CD_PROJECT SELECT
CD_REALTIME_INSTRUMENT SELECT

EDT 2003.14 P & E Global Release Notes Page 79 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

CD_RESERVOIR SELECT
CD_RESERVOIR_STATUS SELECT
CD_SITE_SOURCE SELECT
CD_STRAT_UNIT SELECT
CD_SURVEY_ANALYSIS_LIST SELECT
CD_TEST SELECT
CD_TEST_ANALYSIS SELECT
CD_TEST_ANALYSIS_LINK SELECT
CD_TEST_BEAM SELECT
CD_TEST_CAV SELECT
CD_TEST_FLOW SELECT
CD_TEST_FLUID SELECT
CD_TEST_GAS SELECT
CD_TEST_GAUGE SELECT
CD_TEST_GAUGE_DATA SELECT
CD_TEST_GAUGE_LINK SELECT
CD_TEST_INTERP SELECT
CD_TEST_METER SELECT
CD_TEST_METER_FLUID SELECT
CD_TEST_METER_GAS SELECT
CD_TEST_OIL SELECT
CD_TEST_OIL_DIST SELECT
CD_TEST_OIL_VIS SELECT
CD_TEST_SWAB SELECT
CD_TEST_WATER SELECT
CD_WBO_COMP_LINK SELECT
CD_WELLBORE SELECT
CD_WELLBORE_EXTERNAL SELECT
CD_WELLBORE_FORMATION SELECT
CD_WELLBORE_OPENING SELECT
CD_WELLBORE_ZONE SELECT

EDT 2003.14 P & E Global Release Notes Page 80 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

CD_WELLBORE_ZONE_STATUS SELECT
CD_WELL_EXTERNAL SELECT
CD_WELL_SOURCE SELECT
CD_ZONATION_SCHEME SELECT
CD_ZONE SELECT
CD_ZONE_STRUCTURE SELECT
DM_AFE SELECT
DSS_ALLOCATIONS SELECT
DSS_ANNOTATIONS SELECT
DSS_ANNOT_LEGEND SELECT
DSS_LOOKUP SELECT
DSS_PAT_BUILD SELECT
DSS_PZ_CUM_FORECAST SELECT
DW_DAILY_INJECTION SELECT
DW_DAILY_PROD SELECT
DW_ECON_DETAIL SELECT
DW_ECON_MONTHLY SELECT
DW_ECON_ONELINE SELECT
DW_ECON_OWNER SELECT
DW_ECON_PZFCST SELECT
DW_MONTHLY_INJECTION SELECT
DW_MONTHLY_PROD SELECT
DW_PROD_CUMS SELECT
ECON_EXTENSION SELECT
ECON_EXTENSION_UEXT SELECT
ECON_PROPERTY SELECT
EDM_DATA_SOURCE SELECT
EDM_DOWNHOLE_EQUIPMENT SELECT
EDM_EVENT_WORKOVER_MAP SELECT
EDM_GROUP SELECT
EDM_GROUP_MEMBERS SELECT
EDM_SCENARIO SELECT
EDM_SCENARIO_DTL SELECT
EDM_WELL_WORK_OVER SELECT
GENERATE_KEY EXECUTE
MD_DESKTOP_FORMATS SELECT

EDT 2003.14 P & E Global Release Notes Page 81 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

MD_ERROR_MODEL SELECT
MD_ERROR_SURFACE SELECT
MD_HIERARCHY_ENTITY_BINDING SELECT
MD_HIERARCHY_LEVEL_OBJECTS SELECT
MD_HIERARCHY_SCHEMES SELECT
MD_HIERARCHY_SCHEME_LEVELS SELECT
MD_HIERARCHY_SCHEME_TYPES SELECT
MD_NORTH_TYPE SELECT
MD_PK_DATUM_TYPE SELECT
MD_PK_INSTRUMENT_TYPE SELECT
MD_PK_LOCATION_TYPE_CODE SELECT
MD_PK_PDEN_TYPE SELECT
MD_PK_PHASE SELECT
MD_PK_SCAN_METHOD SELECT
MD_PK_SURVEY_CALC SELECT
MD_PK_WALK_TYPE SELECT
MD_PK_WARNING_METHOD SELECT
MD_PK_WELL_TEST_TYPE SELECT
MD_PK_ZONATION_SCHEME_TYPE SELECT
MD_SITE_APP_ACTION SELECT
MD_SITE_APP_ACTION_OWNER SELECT
MD_SITE_STORAGE_UNITS SELECT
MD_SITE_TIGHT_GROUP SELECT
MD_SITE_TIGHT_GROUP_MEMBER SELECT
MD_SITE_USER SELECT
MD_SYS_ATTR_DICTIONARY SELECT
MD_SYS_BUSOBJ SELECT
MD_SYS_DB_VERSION SELECT
MD_SYS_FIELD_DEF SELECT
MD_SYS_LOOKUP_INIT_HINT SELECT
MD_SYS_TABLE_DEF SELECT
MD_SYS_TABLE_RELATIONS SELECT
MD_UTIL_FIELD_ATTR SELECT
MD_VS_ORIGIN SELECT
PDM_DAILY_INJECTION SELECT
PDM_DAILY_PROD SELECT

EDT 2003.14 P & E Global Release Notes Page 82 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

PDM_MONTHLY_INJECTION SELECT
PDM_MONTHLY_PROD SELECT
PDM_PRODUCTION_HDR SELECT
PDM_PROD_CUMS SELECT
PEM_ALLOC_FACTOR SELECT
PEM_ANALYSIS_CURVE SELECT
PEM_LAYER SELECT
PEM_POOL SELECT
PEM_PREDICT_PERFORM_FLOWING SELECT
PEM_PREDICT_PERFORM_GASLIFT SELECT
PEM_PREDICT_PERFORM_HDR SELECT
PEM_PTA_FLUID_PARAMETERS SELECT
PEM_PTA_GAS_COMPOSITION SELECT
PEM_PTA_INTERPRETATION SELECT
PEM_PTA_LAYER_PARAMETERS SELECT
PEM_PTA_LOG_LOG_RESULTS SELECT
PEM_PTA_QM_DATA SELECT
PEM_PTA_QM_RESULTS SELECT
PEM_PTA_RADIAL_FLOW_RESULTS SELECT
PEM_PTA_RATE_CHANGE SELECT
PEM_PTA_RESERVOIR_DS SELECT
PEM_PTA_TYPE_CURVE_RESULTS SELECT
PEM_PTA_WELL_PARAMETERS SELECT
PEM_REALTIME SELECT
PEM_REALTIME_HOST SELECT
PEM_REALTIME_WIRELINE SELECT
PKG_ACCOUNTING_COMPLETION EXECUTE
PKG_ATTACHMENT EXECUTE
PKG_ATTACHMENT_JOURNAL EXECUTE
PKG_COMPANY EXECUTE
PKG_COMPLETION EXECUTE
PKG_ECONOMIC_PROPERTY EXECUTE
PKG_FORMATS EXECUTE
PKG_GROUPS EXECUTE
PKG_PROJECT EXECUTE
PKG_SCHEMES EXECUTE

EDT 2003.14 P & E Global Release Notes Page 83 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

PKG_SECURITY EXECUTE
PKG_SITE EXECUTE
PKG_SURVEYS EXECUTE
PKG_WELL EXECUTE
PKG_WELLBORE EXECUTE
RMS_BKDELTA SELECT
RMS_BKMEMO SELECT
RMS_BKPROD SELECT
RMS_CHANGE SELECT
RMS_DEFMEMO SELECT
RMS_EIA SELECT
RMS_EIAHEADER SELECT
RMS_EIAID SELECT
RMS_NONBKMEMO SELECT
RMS_PHASE SELECT
RMS_REPORT SELECT
RMS_RESCAT SELECT
RMS_RESERVES SELECT
RMS_RPT SELECT
RMS_RPTHDR SELECT
RMS_SCENARIO SELECT
RMS_SECURITY SELECT
TDML_WRITE_CUMULATIVE EXECUTE
TDML_WRITE_DAILY_INJ EXECUTE
TDML_WRITE_DAILY_PROD EXECUTE
TDML_WRITE_MONTHLY_INJ EXECUTE
TDML_WRITE_MONTHLY_PROD EXECUTE
UMS_SYS_CLASS_ASSIGNMENTS SELECT
UMS_SYS_SETTINGS SELECT
UMS_SYS_UNIT_CLASSES SELECT
UMS_SYS_UNIT_MEASURES SELECT
UMS_SYS_UNIT_SYSTEMS SELECT
UMS_SYS_UNIT_SYSTEMS_HEADER SELECT
UMS_SYS_UNIT_TYPES SELECT
VCV_RB_001 SELECT
VCV_RF_INTERVAL SELECT

EDT 2003.14 P & E Global Release Notes Page 84 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

VCV_RF_TARGET_TYPES SELECT
VC_ACTIVITY SELECT
VC_ACTIVITY_ALLOCATION SELECT
VC_ACTIVITY_COLUMN SELECT
VC_ACTIVITY_INTERFACE SELECT
VC_ACTIVITY_REGULATORY SELECT
VC_ACTIVITY_TDML SELECT
VC_ACTIVITY_VARIANCE SELECT
VC_ADDRESS SELECT
VC_ADDR_TYPE SELECT
VC_AGENCY_PROD_XREF SELECT
VC_ANALYSIS_XREF SELECT
VC_APPS SELECT
VC_APP_SCREENS SELECT
VC_APP_SRVR SELECT
VC_BA SELECT
VC_BATCH_ACTION SELECT
VC_BATCH_ERROR SELECT
VC_BA_TYPE SELECT
VC_CHART_DAYS SELECT
VC_CHEM_PRICE SELECT
VC_CHEM_VESS SELECT
VC_CMPR_STAGE SELECT
VC_COEFF_FACTORS SELECT
VC_COMMENTS SELECT
VC_COMPLETION_RF SELECT
VC_COMPLETION_ZONE SELECT
VC_COMP_CHRON SELECT
VC_COMP_STATUS SELECT
VC_COMP_TYPE SELECT
VC_COMP_ZONE_INJECTION SELECT
VC_COMP_ZONE_PRODUCTION SELECT
VC_COMP_ZONE_XREF SELECT
VC_CONSTRAINTS SELECT
VC_CONTACT SELECT
VC_CONTACT_TYPE SELECT

EDT 2003.14 P & E Global Release Notes Page 85 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

VC_CONTROL_LOG SELECT
VC_CORROSION SELECT
VC_COUNTY SELECT
VC_CTL_LOG_CNTS SELECT
VC_CTL_LOG_VOL SELECT
VC_CURR_DATABASE SELECT
VC_CUST_DEF SELECT
VC_CUST_VALID SELECT
VC_CUST_VALUES SELECT
VC_DAILY_COMPR SELECT
VC_DAILY_ENGINE SELECT
VC_DAILY_GAS_METER SELECT
VC_DAILY_GEN SELECT
VC_DAILY_LIQ_METER SELECT
VC_DAILY_STOP SELECT
VC_DAILY_VEHICLE SELECT
VC_DAILY_VOL_DISP SELECT
VC_DAILY_WEATHER SELECT
VC_DAILY_WELL SELECT
VC_DAILY_WELL_CALC SELECT
VC_DAILY_WELL_DOWN SELECT
VC_DAILY_WELL_INJ SELECT
VC_DAILY_WELL_METER SELECT
VC_DATABASE_ID SELECT
VC_DB_ASSIGN SELECT
VC_DB_DETAIL SELECT
VC_DB_DETAIL_WRK SELECT
VC_DB_ID EXECUTE
VC_DB_TBL_PARMS SELECT
VC_DEFAULT_TIME SELECT
VC_DERIVED_POINT SELECT
VC_DERIVED_VARIANCE SELECT
VC_DESK_CD SELECT
VC_DETAIL_DISPS_AUDIT SELECT
VC_DEVICE_CFG SELECT
VC_DFLT_JOB_CONFIG SELECT

EDT 2003.14 P & E Global Release Notes Page 86 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

VC_DFLT_JOB_PARMS SELECT
VC_DFLT_SCHED_CONFIG SELECT
VC_DISPOSITION SELECT
VC_DISTRIBUTION SELECT
VC_DISTRIB_LIST SELECT
VC_DLY_GAS_CALC_VOL_AUDIT SELECT
VC_DOI SELECT
VC_DOI_HDR SELECT
VC_DOWNTIME SELECT
VC_DV_FORMULA SELECT
VC_ELEC_ENTITY SELECT
VC_ELEC_LINE_COMP_XREF SELECT
VC_ELEC_MEMBERS SELECT
VC_ELEC_SYSTEM SELECT
VC_EQUIPMENT SELECT
VC_EQUIP_COMP_XREF SELECT
VC_EQUIP_COND SELECT
VC_EQUIP_OWNER SELECT
VC_EQUIP_STATUS SELECT
VC_EQUIP_STA_XREF SELECT
VC_EQUIP_TEST SELECT
VC_EQ_SPEC SELECT
VC_EXP_DEPEND_DTL SELECT
VC_FIELD SELECT
VC_FLUID_LEVELS SELECT
VC_FORMATION SELECT
VC_FORMULA_DTL SELECT
VC_FORMULA_HDR SELECT
VC_FUNCTION_ARGS SELECT
VC_FUNCTION_HDR SELECT
VC_FUNCTION_VAL SELECT
VC_GASVOLS SELECT
VC_GAS_CALC_VOL_AUDIT SELECT
VC_GAS_PLANT SELECT
VC_GATHERER SELECT
VC_GRAPH_COLUMNS SELECT

EDT 2003.14 P & E Global Release Notes Page 87 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

VC_GROUPS SELECT
VC_GROUP_MEMBERS SELECT
VC_IMPEXP_DTL SELECT
VC_IMPEXP_HDR SELECT
VC_IMPORT_EXPORT_CFG SELECT
VC_IMPORT_EXPORT_LIST SELECT
VC_INJECTION_PRESSURES SELECT
VC_JOB_DEPENDENCY SELECT
VC_JOB_MSG SELECT
VC_JOB_PARMS SELECT
VC_JOB_QUEUE SELECT
VC_JOB_STREAM_ITEMS SELECT
VC_LAND_LSE SELECT
VC_LD_O_BALANCE SELECT
VC_LD_O_INJECTION SELECT
VC_LD_O_RECOVERY SELECT
VC_LOCATION SELECT
VC_LQVOLSTK SELECT
VC_LQ_VOL SELECT
VC_L_LSE_WELL_XREF SELECT
VC_MESSAGE SELECT
VC_METER SELECT
VC_MONTHLY_VOL_DISP SELECT
VC_MONTHLY_WELL_DOWN SELECT
VC_MTR_PROV SELECT
VC_MT_TYPE SELECT
VC_NOMINATION SELECT
VC_NOMIN_PNT SELECT
VC_NOM_PNT_RATES SELECT
VC_ORG_ASSGN_TYPES SELECT
VC_ORG_DS SELECT
VC_ORG_ENT SELECT
VC_ORG_ENT_ASSGN SELECT
VC_ORG_LVL SELECT
VC_ORIFICE SELECT
VC_ORIG_PRIORITY SELECT
VC_OUTPUT_FORMAT SELECT

EDT 2003.14 P & E Global Release Notes Page 88 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

VC_OWN_IMBAL SELECT
VC_OW_PROJECTS SELECT
VC_OW_WELL_MASTER SELECT
VC_OW_WELL_PROD_ZONE SELECT
VC_PARTNERS SELECT
VC_PARTNER_ASSIGN SELECT
VC_PERIOD_CHEM SELECT
VC_PERSON_ON SELECT
VC_PLATFORM SELECT
VC_POINTS SELECT
VC_PROCESSING_ADJ SELECT
VC_PROC_STAT SELECT
VC_PRODUCING_METHOD SELECT
VC_PRODUCT SELECT
VC_PROD_ANALYSIS SELECT
VC_PROD_STATUS_CD SELECT
VC_PROD_TEST SELECT
VC_PROD_TEST_GAS_METER SELECT
VC_PROD_TEST_LIQ_METER SELECT
VC_PROD_TEST_LQVOLSTK SELECT
VC_PROFILES SELECT
VC_PROFILES_TYPES SELECT
VC_PROFILE_PROC_DAYS SELECT
VC_PROJECT SELECT
VC_PROJECT_ASSIGNMENT SELECT
VC_PROJECT_PHASE SELECT
VC_PROPERTY SELECT
VC_PROP_WELL_XREF SELECT
VC_PROSPECT SELECT
VC_PUMPER_STOP SELECT
VC_PURCHASER SELECT
VC_PURGE_ACTIVITY EXECUTE
VC_PURPOSE SELECT
VC_REG_AGENCY_CD_DS SELECT
VC_REG_ALLOWABLES SELECT

EDT 2003.14 P & E Global Release Notes Page 89 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

VC_REG_BA_XREF SELECT
VC_REG_CA_HDR_FTR_XREF SELECT
VC_REG_CA_RPT_DISP SELECT
VC_REG_CA_RPT_DTL SELECT
VC_REG_CA_XREF SELECT
VC_REG_CONTROL SELECT
VC_REG_EQ_XREF SELECT
VC_REG_HDR_FTR SELECT
VC_REG_HDR_FTR_XREF SELECT
VC_REG_KS_HDR_FTR_XREF SELECT
VC_REG_KS_RPT_DTL SELECT
VC_REG_KS_XREF SELECT
VC_REG_LA_FIELD SELECT
VC_REG_LEASE SELECT
VC_REG_MM_EQ_XREF SELECT
VC_REG_MM_HDR_FTR_XREF SELECT
VC_REG_MM_LEASE SELECT
VC_REG_MM_RPT_DTL SELECT
VC_REG_MM_XREF SELECT
VC_REG_MP_XREF SELECT
VC_REG_ND_GAS_PLANT SELECT
VC_REG_PROD_INTERV SELECT
VC_REG_RPT_DTL SELECT
VC_REG_RPT_SRC SELECT
VC_REG_RPT_VOLS SELECT
VC_REG_SRC SELECT
VC_REG_XREF SELECT
VC_RELATED_SYSTEMS SELECT
VC_REPORTS_GRAPHS SELECT
VC_RESERVOIR SELECT
VC_ROUTE SELECT
VC_RPT_BASE_DTL_1 SELECT
VC_RPT_BASE_HDR SELECT
VC_RPT_CONFIG SELECT
VC_RPT_DLY_GAS_SUM SELECT

EDT 2003.14 P & E Global Release Notes Page 90 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

VC_RPT_GAS_MTR_HIST SELECT
VC_RPT_GRP_DS SELECT
VC_RPT_GRP_XRF SELECT
VC_RPT_LSE SELECT
VC_RPT_MTH_GAS_SUM SELECT
VC_SAFETY SELECT
VC_SCADA_ATTRIBUTES SELECT
VC_SCADA_DAILY_TAG_VALUES SELECT
VC_SCADA_DATA_SRCS SELECT
VC_SCADA_TAG_DEF SELECT
VC_SCADA_TAG_ENT_XREF SELECT
VC_SCADA_TAG_FILE_LYT SELECT
VC_SCADA_TAG_NORM_RULES SELECT
VC_SCADA_TEST_TAG_VALUES SELECT
VC_SCADA_TIME_SLICE_TAG_VALUE SELECT
VC_SCAD_GAS_METER SELECT
VC_SCAD_LIQ_METER SELECT
VC_SCAD_LQVOLSTK SELECT
VC_SCREENS SELECT
VC_SCREEN_ENT_XREF SELECT
VC_SEALS SELECT
VC_SELECT_DTL SELECT
VC_SELECT_HDR SELECT
VC_SELECT_SQL SELECT
VC_SESSION_DB_OWN SELECT
VC_SESSION_STATE SELECT
VC_SHIPMENT SELECT
VC_SK_CONTROL SELECT
VC_SK_RESERV SELECT
VC_SK_TYPE_CD_XRF SELECT
VC_SK_TYPE_VAL SELECT
VC_SK_XREF SELECT
VC_STATE_PROV SELECT
VC_STATION SELECT
VC_STATION_SUMMARY SELECT
VC_STEAM_CYCLE SELECT

EDT 2003.14 P & E Global Release Notes Page 91 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

VC_STRAPS SELECT
VC_SUB_TOPICS SELECT
VC_SUB_TOPIC_GRIDS SELECT
VC_SYSTEM SELECT
VC_SYS_DOWNTIME SELECT
VC_SYS_MSG SELECT
VC_SYS_REQUIRED SELECT
VC_SYS_SQL SELECT
VC_SYS_STATUS SELECT
VC_SYS_SUM SELECT
VC_TANK_CAP SELECT
VC_TARGET SELECT
VC_TEMPLATES SELECT
VC_TEMPLATE_ASSIGN SELECT
VC_TEMPLATE_COLUMNS SELECT
VC_TEMPLATE_CONTROLS SELECT
VC_TEMPLATE_DETAIL SELECT
VC_TERMINAL SELECT
VC_TERMINAL_EQUIP SELECT
VC_TERM_LEDGER SELECT
VC_TEST_CALC SELECT
VC_THERMOMETER SELECT
VC_TOPICS SELECT
VC_TOPIC_COLUMNS SELECT
VC_TOPIC_DETAIL SELECT
VC_TOPIC_JOINS SELECT
VC_TOWCS_DICT_ALL SELECT
VC_TOW_EXIT_CALLS SELECT
VC_TOW_REF SELECT
VC_TOW_REF_HDR SELECT
VC_TUBE SELECT
VC_UPD_CALC_DT_TO EXECUTE
VC_UPD_DEACT_DT EXECUTE
VC_USAGE_RATES SELECT
VC_USER_CONFIG SELECT
VC_USER_DESK_XREF SELECT

EDT 2003.14 P & E Global Release Notes Page 92 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

TABLE_NAME PRIVILEGE

VC_VALIDATIONS SELECT
VC_VAL_ARGUMENTS SELECT
VC_VAL_CONDITIONS SELECT
VC_VAL_DICT_XREF SELECT
VC_VAL_RULES SELECT
VC_VAL_TEMP_ARG_XREF SELECT
VC_VAL_TEMP_XREF SELECT
VC_VARIANCE SELECT
VC_VARIANCE_DIST SELECT
VC_VARIANCE_DTL SELECT
VC_VARIANCE_RPT SELECT
VC_VESSEL_INC SELECT
VC_WATER_CALC SELECT
VC_WELLCOMP SELECT
VC_WELL_BEG_BAL SELECT
VC_WELL_CNTS SELECT
VC_WELL_POTENTIAL SELECT

EDT 2003.14 P & E Global Release Notes Page 93 of 94 June 2005


Landmark Production & Economics R2003.14 Global Release Notes

Landmark/Asia Pacific Landmark/EAME Landmark/The Americas


11th Floor Menara Tan & Tan Hill Park South 2101 CityWest Blvd, Building 2
207 Jalan Tun Razak Springfield Drive Houston, TX 77042-3021
50400 Kuala Lumpur Leatherhead, Surrey GU22 7NL P.O. Box 42806, Houston, TX 77242
Malaysia England U.S.A.
Tel: 011-60-3-2164-1121 Tel: 011-44 (0) 1372 868-600 Tel: 713-839-2000
Fax: 011-60-3-2164-1135 Fax: 011-44 (0) 1372 868-601 Help Desk: 713-839-2200
Help Desk: 011-61-8-9481-4488 Help Desk: 011-44 (0) 1372-868- Fax: 713-839-2168
Email: apsupport@lgc.com 686 Email: support@lgc.com
Email: eame_helpdesk@lgc.com

Trademarks
3DFS, 3D Drill View, 3D Drill View KM, 3DView, 3D Surveillance, Active Field Surveillance, Active Reservoir Surveillance,
ADC, Advanced Data Transfer, ARIES, Asset Development Center, AssetJournal, Asset Performance, AssetView, Atomic
Meshing, Automate, BLITZ, BLITZPAK, CasingSeat, COMPASS, Contouring Assistant, Corporate Data Archiver, Corporate Data
Store, DataManager, DataStar, DBPlot, DecisionSuite, Decisionarium, DecisionSpace, DecisionSpace AssetPlanner,
DecisionSpace AssetView, DecisionSpace Atomic Meshing, DecisionSpace Decision Management Systems(DMS), DecisionSpace
Nexus, DecisionSpace PowerGrid, DecisionSpace PowerModel, DecisionSpace PrecisionTarget, DecisionSpace Reservoir,
DecisionSpace TracPlanner, DecisionSpace Well Seismic Fusion, DepthTeam, DepthTeam Explorer, DepthTeam Express,
DepthTeam Extreme, DepthTeam Interpreter, Desktop Navigator, DESKTOP-PVT, DESKTOP-VIP, DEX, DIMS, Discovery,
Discovery Asset, Drill-to-the-Earth Model, Drillability Suite, Drilling Desktop, DrillModel, DrillVision, DSS, Dynamic Reservoir
Management, Dynamic Surveillance System, EarthCube, EDM, eLandmark, Engineers Data Model, The Engineer's Desktop,
Engineers Link, Executive Assistant, ezFault, ezSurface, ezTracker, FG+, FastTrack, FieldWorks, FZAP!, GeoDataLoad,
GeoGraphix (stylized), GeoGraphix Exploration System, GeoLink, GeoProbe, GeoProbe GF DataServer, GES, GESXplorer,
GMAplus, GRIDGENR, Handheld Field Operator, I2 Enterprise, iDIMS, IsoMap, iWellFile, Landmark, Landmark & Design,
Landmark Logo & Design, Landmark Decision Center, Landscape, Lattix, LeaseMap, LMK Resources, LogEdit, LogM, LogPrep,
Magic Earth, MagicDesk, Make Great Decisions, MathPack, MIMIC, MIMIC+, MIRA, Model Builder, MyLandmark, Nexus,
Object MP, OpenBooks, Open Explorer, OpenJournal, OpenSGM, OpenVision, OpenWells, OpenWire, OpenWorks, OpenWorks
Well File, PAL, Parallel-VIP, PetroBank, PetroWorks, PetroWorks ULTRA, PlotView, Point Gridding Plus, Pointing Dispatcher,
PostStack, PostStack ESP, PowerCalculator, PowerExplorer, PowerHub, Power Interpretation, PowerJournal, PowerModel,
PowerView, Presgraf, PRIZM, PROFILE, Project Administrator, ProMAGIC, ProMAGIC Connect, ProMAGIC Server, ProMAX,
ProMAX 2D, ProMAX 3D, ProMAX 3DPSDM, ProMAX MVA, ProMAX VSP, pSTAx, Query Builder, Quick, Quick+,
QUICKDIF, QUIKCDP, QUIKDIG, QUIKRAY, QUIKSHOT, QUIKVSP, Quickwell, Quickwell+, RAVE, RayMap, RayMap+,
RTOC, Real Time Asset Management Center, Real Time Asset Management Centre, Real Time Knowledge Company, Real Time
Operations Center, Real Time Production Surveillance, Real Time Surveillance, Reference Data Manager, Reservoir Framework
Builder, RESev, ResMap, RightTime, RMS, SCAN, SeisCube, SeisMap, SeisModel, SeisSpace, SeisVision, SeisWell, SeisWorks,
SeisWorks PowerCalculator, SeisWorks PowerJournal, SeisWorks PowerSection, SeisXchange, Sierra, Sierra (design), SigmaView,
SimResults, SIVA, SIVA+, smartSECTION, Spatializer, SpecDecomp, StrataAmp, StrataMap, StrataModel, StrataSim, StratWorks,
StressCheck, STRUCT, Surf & Connect, SynTool, SystemStart for Servers, SystemStart, SystemStart for Clients, SystemStart for
Storage, Tanks & Tubes, TDQ, Team Workspace, TERAS, Total Drilling Performance, TOW/cs, TOW/cs Revenue Interface,
TracPlanner, Trend Form Gridding, Turbo Synthetics, VESPA, VESPA+, VIP, VIP-COMP, VIP-CORE, VIP-DUAL, VIP-
ENCORE, VIP-EXECUTIVE, VIP-Local Grid Refinement, VIP-THERM, WavX, Web Editor, Well Seismic Fusion, Wellbase,
Wellbore Planner, Wellbore Planner Connect, WELLCAT, WELLPLAN, WellXchange, WOW, Xsection, You're in Control.
Experience the difference, ZAP!, and Z-MAP Plus are trademarks, registered trademarks or service marks of Landmark Graphics
Corporation.

All other trademarks are the property of their respective owners.

2005 Landmark Graphics Corporation. All rights reserved.

EDT 2003.14 P & E Global Release Notes Page 94 of 94 June 2005

Potrebbero piacerti anche