Technical Information
Proline Promass A 100
Coriolis flowmeter
Table of contents
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Ambient temperature range . . . . . . . . . . . . . . . . . . . . . 41 Standard documentation . . . . . . . . . . . . . . . . . . . . . . . . 73
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Supplementary device-dependent documentation . . . . . . . 74
Climate class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . 43
2 Endress+Hauser
Proline Promass A 100
Registered trademarks . . . . . . . . . . . . . . . . . . . . . . 74
Endress+Hauser 3
Proline Promass A 100
Document information
Symbols used Electrical symbols
Symbol Meaning
Direct current
A terminal to which DC voltage is applied or through which direct current flows.
Alternating current
A terminal to which alternating voltage is applied or through which alternating current flows.
Ground connection
A grounded terminal which, as far as the operator is concerned, is grounded via a grounding
system.
Equipotential connection
A connection that has to be connected to the plant grounding system: This may be a potential
equalization line or a star grounding system depending on national or company codes of practice.
Symbol Meaning
Permitted
Indicates procedures, processes or actions that are permitted.
Preferred
Indicates procedures, processes or actions that are preferred.
Forbidden
Indicates procedures, processes or actions that are forbidden.
Tip
Indicates additional information.
Reference to documentation
Refers to the corresponding device documentation.
Reference to page
Refers to the corresponding page number.
Reference to graphic
Refers to the corresponding graphic number and page number.
Visual inspection
Symbols in graphics
Symbol Meaning
A, B, C, ... Views
Flow direction
4 Endress+Hauser
Proline Promass A 100
Symbol Meaning
Hazardous area
- Indicates a hazardous area.
Fc = 2 m ( )
Fc = Coriolis force
m = moving mass
= rotational velocity
The amplitude of the Coriolis force depends on the moving mass m, its velocity in the system and
thus on the mass flow. Instead of a constant rotational velocity , the sensor uses oscillation.
In the sensor, an oscillation is produced in the measuring tube. The Coriolis forces produced at the
measuring tube cause a phase shift in the tube oscillations (see illustration):
If there is zero flow (i.e. when the fluid stands still), the oscillation measured at points A and B has
the same phase (no phase difference).
Mass flow causes deceleration of the oscillation at the inlet of the tubes (2) and acceleration at the
outlet (3).
1 2 3
A0016772
The phase difference (A-B) increases with increasing mass flow. Electrodynamic sensors register the
tube oscillations at the inlet and outlet. System balance is created by exciting an eccentrically
arranged swinging mass to antiphase oscillation. The measuring principle operates independently of
temperature, pressure, viscosity, conductivity and flow profile.
Density measurement
The measuring tube is continuously excited at its resonance frequency. A change in the mass and
thus the density of the oscillating system (comprising measuring tube and fluid) results in a
corresponding, automatic adjustment in the oscillation frequency. Resonance frequency is thus a
function of medium density. The microprocessor utilizes this relationship to obtain a density signal.
Volume measurement
Together with the measured mass flow, this is used to calculate the volume flow.
Temperature measurement
The temperature of the measuring tube is determined in order to calculate the compensation factor
due to temperature effects. This signal corresponds to the process temperature and is also available
as an output signal.
Endress+Hauser 5
Proline Promass A 100
Measuring system The device consists of a transmitter and a sensor. If a device with Modbus RS485 intrinsically safe is
ordered, the Safety Barrier Promass 100 is part of the scope of supply and must be implemented to
operate the device.
One device version is available: compact version, transmitter and sensor form a mechanical unit.
Transmitter
Sensor
6 Endress+Hauser
Proline Promass A 100
Device architecture
1 2 3 4
10
5 6 7
A0016779
Safety IT security
We only provide a warranty if the device is installed and used as described in the Operating
Instructions. The device is equipped with security mechanisms to protect it against any inadvertent
changes to the device settings.
IT security measures in line with operators' security standards and designed to provide additional
protection for the device and device data transfer must be implemented by the operators themselves.
Input
Measured variable Direct measured variables
Mass flow
Density
Temperature
Endress+Hauser 7
Proline Promass A 100
1 0 to 20 0 to 0.735
2 0 to 100 0 to 3.675
4 0 to 450 0 to 16.54
DN x
1 32
2 32
4 32
To calculate the measuring range, use the Applicator sizing tool ( 72)
Output
Output signal Current output
Load 0 to 700
8 Endress+Hauser
Proline Promass A 100
Resolution 0.38 A
Pulse/frequency/switch output
Pulse output
Frequency output
Switch output
Endress+Hauser 9
Proline Promass A 100
PROFIBUS DP
Modbus RS485
Terminating resistor For device version used in non-hazardous areas or Zone 2/Div. 2: integrated
and can be activated via DIP switches on the transmitter electronics module
For device version used in intrinsically safe areas: integrated and can be
activated via DIP switches on the Safety Barrier Promass 100
EtherNet/IP
Current output
4-20 mA
Failure mode Selectable (as per NAMUR recommendation NE 43):
Minimum value: 3.6 mA
Maximum value: 22 mA
Defined value: 3.59 to 22.5 mA
Actual value
Last valid value
HART
Device diagnostics Device condition can be read out via HART Command 48
10 Endress+Hauser
Proline Promass A 100
Pulse/frequency/switch output
Pulse output
Frequency output
Switch output
PROFIBUS DP
Modbus RS485
EtherNet/IP
Local display
Operating tool
Via digital communication:
HART protocol
PROFIBUS DP
Modbus RS485
EtherNet/IP
Via service interface
Endress+Hauser 11
Proline Promass A 100
Web browser
Ex connection data These values only apply for the following device version:
Order code for "Output", option M: Modbus RS485, for use in intrinsically safe areas
Safety-related values
Terminal numbers
Unom = DC 24 V Unom = DC 5 V
Umax = AC 260 V Umax = AC 260 V
Uo = 16.24 V
Io = 623 mA
Po = 2.45 W
For IIC*: Lo = 92.8 H, Co = 0.433 F, Lo/Ro = 14.6 H/
For IIB*: Lo= 372 H, Co = 2.57 F, Lo/Ro = 58.3 H/
* The gas group depends on the sensor and nominal diameter.
For an overview and for information on the interdependencies between the gas group - sensor - nominal
diameter, see the "Safety Instructions" (XA) document for the measuring device
Transmitter
For an overview and for information on the interdependencies between the gas group - sensor - nominal
diameter, see the "Safety Instructions" (XA) document for the measuring device
Low flow cut off The switch points for low flow cut off are user-selectable.
12 Endress+Hauser
Proline Promass A 100
Galvanic isolation The following connections are galvanically isolated from each other:
Outputs
Power supply
Manufacturer ID 0x11
Endress+Hauser 13
Proline Promass A 100
PROFIBUS DP
Manufacturer ID 0x11
14 Endress+Hauser
Proline Promass A 100
Modbus RS485
Data access Each device parameter can be accessed via Modbus RS485.
For Modbus register information ( 73)
EtherNet/IP
Manufacturer ID 0x49E
Polarity Auto-polarity for automatic correction of crossed TxD and RxD pairs
Endress+Hauser 15
Proline Promass A 100
Configuration options for DIP switches on the electronics module for IP addressing
measuring device Manufacturer-specific software (FieldCare)
Add-on Profile Level 3 for Rockwell Automation control systems
Web browser
Electronic Data Sheet (EDS) integrated in the measuring device
Configuration of the EtherNet Speed: 10 MBit, 100 MBit, auto (factory setting)
interface Duplex: half-duplex, full-duplex, auto (factory setting)
Configuration of the device DIP switches on the electronics module for IP addressing (last octet)
address DHCP
Manufacturer-specific software (FieldCare)
Add-on Profile Level 3 for Rockwell Automation control systems
Web browser
EtherNet/IP tools, e.g. RSLinx (Rockwell Automation)
Fix Input
O T configuration: 0x66 64
T O configuration: 0x64 44
O T configuration: 0x66 64
T O configuration: 0x64 44
O T configuration: 0xC7 -
T O configuration: 0x64 44
O T configuration: 0xC7 -
T O configuration: 0x64 44
Configurable Input
O T configuration: 0x66 64
T O configuration: 0x65 88
16 Endress+Hauser
Proline Promass A 100
O T configuration: 0x66 64
T O configuration: 0x65 88
O T configuration: 0xC7 -
T O configuration: 0x65 88
O T configuration: 0xC7 -
T O configuration: 0x65 88
Fix Output
Configuration
Configuration Assembly Only the most common configurations are listed below.
Software write protection
Mass flow unit
Mass unit
Volume flow unit
Volume unit
Corrected volume flow unit
Corrected volume unit
Density unit
Reference density unit
Temperature unit
Pressure unit
Length
Totalizer 1-3:
Assignment
Unit
Measuring mode
Failure mode
Alarm delay
Endress+Hauser 17
Proline Promass A 100
Power supply
Terminal assignment Overview: housing version
1 2
3 4
A0016770
Transmitter
18 Endress+Hauser
Proline Promass A 100
Depending on the housing version, the transmitters can be ordered with terminals or device plugs.
Options Device plug Terminals Option L: plug M12x1 + thread NPT "
A, B Option N: plug M12x1 + coupling M20
Option P: plug M12x1 + thread G "
Option U: plug M12x1 + thread M20
24 +
_ 3
25
26 +
_ 2
27
1 L+
1
2 L_
A0016888
Terminal number
Order code for
Power supply Output 1 Output 2
"Output"
2 (L-) 1 (L+) 27 () 26 (+) 25 () 24 (+)
Endress+Hauser 19
Proline Promass A 100
Options Device plug Terminals Option L: plug M12x1 + thread NPT "
A, B Option N: plug M12x1 + coupling M20
Option P: plug M12x1 + thread G "
Option U: plug M12x1 + thread M20
26 B
27 A
2
1 L+
1
2 L_
A0022716
Terminal number
Option L DC 24 V B A
20 Endress+Hauser
Proline Promass A 100
Options Device plug Terminals Option L: plug M12x1 + thread NPT "
A, B Option N: plug M12x1 + coupling M20
Option P: plug M12x1 + thread G "
Option U: plug M12x1 + thread M20
26 A
27 B
2
1 L+
1
2 L_
A0019528
4 Modbus RS485 terminal assignment, connection version for use in non-hazardous areas and Zone 2/Div.
2
1 Power supply: DC 24 V
2 Modbus RS485
Terminal number
Order code for
Power supply Output
"Output"
2 (L-) 1 (L+) 27 (B) 26 (A)
Endress+Hauser 21
Proline Promass A 100
62 A
72 B
2
10 L +
1
20 L _
A0017053
5 Modbus RS485 terminal assignment, connection version for use in intrinsically safe areas (connection via
Safety Barrier Promass 100)
1 Intrinsically safe power supply
2 Modbus RS485
22 Endress+Hauser
Proline Promass A 100
Options Device plug Terminals Option L: plug M12x1 + thread NPT "
A, B Option N: plug M12x1 + coupling M20
Option P: plug M12x1 + thread G "
Option U: plug M12x1 + thread M20
1 L+
1
2 L_
A0017054
Terminal number
Order code for
Power supply Output
"Output"
2 (L-) 1 (L+) Device plug M12x1
Option N DC 24 V EtherNet/IP
Endress+Hauser 23
Proline Promass A 100
2 1 26 27
L L+ A B
Power Modbus
supply RS485
1 24VDC
Safe area
Power
Lift panel for
bus termination
Communication
A
Safety Barrier
Promass 100
Hazardous area
A Power Modbus
supply RS485
L L+ A B
20 10 62 72
2
A0016922
Pin assignment, device plug Order codes for the M12x1 connectors, see the "Order code for electrical connection" column:
4-20 mA HART, pulse/frequency/switch output ( 18)
PROFIBUS-DP( 20)
Modbus RS485 ( 21)
EtherNet/IP ( 23)
Supply voltage
For all connection versions except MODBUS RS485 intrinsically safe (device side)
Device plug MODBUS RS485 intrinsically safe with supply voltage ( 25)
1 L+ DC 24 V A Plug
2
3 1
3
5 4 L- DC 24 V
4
A0016809
5 Grounding/shielding
24 Endress+Hauser
Proline Promass A 100
4 4 - Pulse/frequency/switch output
A0016810 (passive)
5 Grounding/shielding
PROFIBUS DP
For use in the non-hazardous area and Zone 2/Div. 2.
1 B Socket
2 A PROFIBUS DP
1 3
3
5 4 B PROFIBUS DP
4
A0016811
5 Grounding/shielding
MODBUS RS485
Device plug for signal transmission with supply voltage (device side), MODBUS RS485 (intrinsically
safe)
2 A
3 1 Modbus RS485 intrinsically safe
3 B
5 4 L- Supply voltage, intrinsically safe
4
A0016809
5 Grounding/shielding
Endress+Hauser 25
Proline Promass A 100
Device plug for signal transmission (device side), MODBUS RS485 (not intrinsically safe)
For use in the non-hazardous area and Zone 2/Div. 2.
1 B Socket
2 A Modbus RS485
1 3
3
5 4 B Modbus RS485
4
A0016811
5 Grounding/shielding
EtherNet/IP
1 + Tx D Socket
2 + Rx
1 3
3 - Tx
4 - Rx
4
A0016812
Recommended plug:
Binder, series 763, part no. 99 3729 810 04
Phoenix, part no. 1543223 SACC-M12MSD-4Q
When using the device in a hazardous location: Use a suitably certified plug.
26 Endress+Hauser
Proline Promass A 100
Option M: Modbus RS485, for use in intrinsically safe areas 230 mA 10 A (<0.8 ms)
A B C
1 2 1 2 3 4
A0016924
Endress+Hauser 27
Proline Promass A 100
Connection examples
1 2 3
4...20 mA
+ +
6
_
4 5
A0016800
Pulse/frequency output
1 2
+
_ +
3
+
12345
A0016801
Switch output
1 2
_ +
_
+
_ 3
+
A0016802
28 Endress+Hauser
Proline Promass A 100
PROFIBUS DP
1 2
A A
3
B
B
A
3
B
A0021429
11 Connection example for PROFIBUS DP, non-hazardous area and Zone 2/Div. 2
1 Control system (e.g. PLC)
2 Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
specifications ( 32)
3 Distribution box
4 Transmitter
If baud rates > 1.5 MBaud an EMC cable entry must be used and the cable shield must continue
as far as the terminal wherever possible.
Modbus RS485
1 2 3
A A
4
B
B
A
4
B
A0016803
12 Connection example for Modbus RS485, non-hazardous area and Zone 2/Div. 2
1 Control system (e.g. PLC)
2 Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
specifications ( 32)
3 Distribution box
4 Transmitter
Endress+Hauser 29
Proline Promass A 100
1 2 3 4
A A
A A B B
L+ 8
B L+
B
L- L+ L- L-
5 6 7
A0016804
EtherNet/IP
1 2 3 4
A0016805
30 Endress+Hauser
Proline Promass A 100
HART input
1 2 3 4
4...20 mA
+
5
-
-
+ 6
A0019828
15 Connection example for HART input (burst mode) via current output (active)
1 Cable shield, observe cable specifications ( 32)
2 Resistor for HART communication ( 250 ): observe maximum load ( 8)
3 Connection for HART operating devices ( 66)
4 Analog display unit
5 Transmitter
6 Sensor for external measured variable
1 2 3 4 5
4...20 mA
+
+ 6
-
-
-
+
-
7
+
4...20 mA
2 3 4 5
A0019830
16 Connection example for HART input (master mode) via current output (active)
1 Automation system with current input (e.g. PLC).
Prerequisite: automation system with HART version 6, HART commands 113 and 114 can be processed.
2 Cable shield, observe cable specifications ( 32)
3 Resistor for HART communication ( 250 ): observe maximum load ( 8)
4 Connection for HART operating devices ( 66)
5 Analog display unit
6 Transmitter
7 Sensor for external measured variable
Terminals Transmitter
Spring terminals for wire cross-sections0.5 to 2.5 mm2 (20 to 14 AWG)
Safety Barrier Promass 100
Plug-in screw terminals for wire cross-sections0.5 to 2.5 mm2 (20 to 14 AWG)
Endress+Hauser 31
Proline Promass A 100
Cable entries Cable gland: M20 1.5 with cable 6 to 12 mm (0.24 to 0.47 in)
Thread for cable entry:
NPT "
G "
M20
Signal cable
Current output
For 4-20 mA HART: Shielded cable recommended. Observe grounding concept of the plant.
Pulse/frequency/switch output
Standard installation cable is sufficient.
PROFIBUS DP
The IEC 61158 standard specifies two types of cable (A and B) for the bus line which can be used for
every transmission rate. Cable type A is recommended.
Cable type A
Signal damping Max. 9 dB over the entire length of the cable cross-section
Shielding Copper braided shielding or braided shielding with foil shield. When grounding
the cable shield, observe the grounding concept of the plant.
Modbus RS485
The EIA/TIA-485 standard specifies two types of cable (A and B) for the bus line which can be used
for every transmission rate. Cable type A is recommended.
Cable type A
Signal damping Max. 9 dB over the entire length of the cable cross-section
Shielding Copper braided shielding or braided shielding with foil shield. When grounding
the cable shield, observe the grounding concept of the plant.
EtherNet/IP
The standard ANSI/TIA/EIA-568-B.2 Annex specifies CAT 5 as the minimum category for a cable
used for EtherNet/IP. CAT 5e and CAT 6 are recommended.
32 Endress+Hauser
Proline Promass A 100
For more information on planning and installing EtherNet/IP networks, please refer to the
"Media Planning and Installation Manual. EtherNet/IP" of the ODVA Organization.
Connecting cable between Safety Barrier Promass 100 and measuring device
Cable type Shielded twisted-pair cable with 2x2 wires. When grounding the cable shield,
observe the grounding concept of the plant.
Comply with the maximum cable resistance specifications to ensure the operational reliability
of the measuring device.
The maximum cable length for individual wire cross-sections is specified in the table below. Observe
the maximum capacitance and inductance per unit length of the cable and connection values for
hazardous areas ( 12).
0.5 20 70 230
Performance characteristics
Reference operating Error limits based on ISO 11631
conditions Water with +15 to +45 C (+59 to +113 F) at2 to 6 bar (29 to 87 psi)
Specifications as per calibration protocol
Accuracy based on accredited calibration rigs that are traced to ISO 17025.
To obtain measured errors, use the Applicator sizing tool ( 72)
Base accuracy
Mass flow and volume flow (liquids)
0.10 %
Mass flow (gases)
0.50 % o.r.
Design fundamentals ( 35)
Density (liquids)
Reference conditions:0.0005 g/cm
Standard density calibration:0.02 g/cm
(valid over the entire temperature range and density range )
Wide-range density specification (order code for "Application package", option EF "Special density
and concentration ") : 0.002 g/cm (valid range for special density calibration: 0.0 to 2 g/cm,
+5 to +80 C (+41 to +176 F))
Temperature
0.5 C 0.005 T C (0.9 F 0.003 (T 32) F)
Endress+Hauser 33
Proline Promass A 100
1 0.0010 0.000036
2 0.0050 0.00018
4 0.0225 0.0008
Flow values
Flow values as turndown parameter depending on nominal diameter.
SI units
2 100 10 5 2 1 0.2
US units
Accuracy of outputs
o.r. = of reading; o.f.s. = of full scale value
The output accuracy must be factored into the measured error if analog outputs are used, but
can be ignored for fieldbus outputs (e.g. Modbus RS485, EtherNet/IP).
Current output
Pulse/frequency output
Base repeatability
Mass flow and volume flow (liquids)
0.05 % o.r.
Mass flow (gases)
0.25 % o.r.
Design fundamentals ( 35)
34 Endress+Hauser
Proline Promass A 100
Density (liquids)
0.00025 g/cm3
Temperature
0.25 C 0.0025 T C (0.45 F0.0015 (T32) F)
Pulse/frequency output
[kg/m3]
10
8
6
1 2
4
2
0
-50 0 50 100 150 200 [C]
-80 -40 0 40 80 120 160 200 240 280 320 360 400 [F]
A0016616
Temperature
0.005 T C (0.005 (T 32) F)
Influence of medium A difference between the calibration pressure and process pressure does not affect accuracy.
pressure
Endress+Hauser 35
Proline Promass A 100
ZeroPoint
BaseAccu 100 BaseAccu
A0021339
A0021332
ZeroPoint ZeroPoint
< BaseAccu 100 MeasValue 100
A0021333 A0021334
ZeroPoint
BaseRepeat 100
A0021340
A0021335
ZeroPoint ZeroPoint
< BaseRepeat 100 MeasValue 100
A0021336 A0021337
E [%]
2.5
2.0
1.5
1.0
0.5
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Q [%]
A0016709
Installation
No special measures such as supports are necessary. External forces are absorbed by the construction
of the device.
Mounting location To prevent measuring errors arising from accumulation of gas bubbles in the measuring tube, avoid
the following mounting locations in the pipe:
Highest point of a pipeline.
Directly upstream of a free pipe outlet in a down pipe.
36 Endress+Hauser
Proline Promass A 100
A0023344
A0015596
1 0.8 0.03
2 1.5 0.06
4 3.0 0.12
Endress+Hauser 37
Proline Promass A 100
Orientation The direction of the arrow on the sensor nameplate helps you to install the sensor according to the
flow direction (direction of medium flow through the piping).
Orientation Recommendation
A Vertical orientation
A0015591
1)
B Horizontal orientation, transmitter
head up Exception:
A0015589
2)
C Horizontal orientation, transmitter
head down Exception:
A0015590
1) Applications with low process temperatures may reduce the ambient temperature. To maintain the
minimum ambient temperature for the transmitter, this orientation is recommended.
2) Applications with high process temperatures may increase the ambient temperature. To maintain the
maximum ambient temperature for the transmitter, this orientation is recommended.
Inlet and outlet runs No special precautions need to be taken for fittings which create turbulence, such as valves, elbows
or T-pieces, as long as no cavitation occurs ( 47).
E
G
45
F
i
A
1 3
B
RUPTURE DISK
2
A0019676
38 Endress+Hauser
Proline Promass A 100
Dimensions in SI units
DN A B C D E F G
Dimensions in US units
DN A B C D E F G
Wall mounting
!WARNING
Incorrect sensor mounting
Risk of injury if measuring tube breaks
The sensor should never be installed in a pipe in a way that it is freely suspended
Using the base plate, mount the sensor directly on the floor, wall or ceiling.
Support the sensor on a securely mounted support base (e.g. angle bracket).
The following mounting versions are recommended for the installation.
Vertical
Mounted directly on a wall using the base plate, or
Device supported on an angle bracket mounted on the wall
A0019631
Horizontal
Device standing on a solid support base
A0019632
Post retainer
The post retainer mounting kit is used to secure the device to a pipe or post (order code for
"Accessories", option PR).
Endress+Hauser 39
Proline Promass A 100
1 2 3 4 5 6 7 8
13 mm 10 mm
A0019746
A0016894
19 Minimum distance between additional Safety Barrier Promass 100 or other modules.Engineering unit mm
(in)
40 Endress+Hauser
Proline Promass A 100
Environment
Ambient temperature range Measuring device Non-Ex 40 to +60 C (40 to +140 F)
If operating outdoors:
Avoid direct sunlight, particularly in warm climatic regions.
Weather protection covers can be ordered from Endress+Hauser: see "Accessories" section
Temperature tables
In the following tables, the following interdependencies between the maximum medium
temperature for T1-T6 and the maximum ambient temperature Ta apply when operating the device
in hazardous areas.
Ex ia, CCSAUS IS
SI units
Order code for "Housing" Ta T6 T5 T4 T3 T2 T1
[C] [85 C] [100 C] [135 C] [200 C] [300 C] [450 C]
1) The following applies for specified sensors with a maximum medium temperature Tm = 200 C: Tm = 170 C
2) The following applies for specified sensors with a maximum medium temperature Tm = 200 C: Tm = 200 C
US units
Order code for "Housing" Ta T6 T5 T4 T3 T2 T1
[F] [185 F] [212 F] [275 F] [392 F] [572 F] [842 F]
1) The following applies for specified sensors with a maximum medium temperature Tm = 392 F: Tm = 338 F
2) The following applies for specified sensors with a maximum medium temperature Tm = 392 F: Tm = 392 F
Endress+Hauser 41
Proline Promass A 100
SI units
Order code for "Housing" Ta T6 T5 T4 T3 T2 T1
[C] [85 C] [100 C] [135 C] [200 C] [300 C] [450 C]
1) The following applies for specified sensors with a maximum medium temperature Tm = 200 C: Tm = 170 C
2) The following applies for specified sensors with a maximum medium temperature Tm = 200 C: Tm = 200 C
US units
Order code for "Housing" Ta T6 T5 T4 T3 T2 T1
[F] [185 F] [212 F] [275 F] [392 F] [572 F] [842 F]
Option C "Ultra compact hygienic, 122 185 248 302 302 302
stainless, M12 device plug" 140 248 302 302 302
1) The following applies for specified sensors with a maximum medium temperature Tm = 392 F: Tm = 338 F
2) The following applies for specified sensors with a maximum medium temperature Tm = 392 F: Tm = 392 F
Example
Measured maximum ambient temperature: Tma = 47 C
Measured maximum medium temperature: Tmm = 108 C
Ta T6 T5 T4 T3 T2 T1
[C] [85C] [100C] [135C] [200C] [300C] [450C]
35 50 85 120 140 140 140
50 85 120 140 140 140
60 120 140 140 140
35 50 85 120 140 140 140
45 85 120 140 140 140
50 120 140 140 140
A0019758
1. Select device.
2. In the column for the maximum ambient temperature Ta select the temperature that is
immediately greater than or equal to the measured maximum ambient temperature Tma that is
present.
Ta = 50 C.
The row showing the maximum medium temperature is determined.
42 Endress+Hauser
Proline Promass A 100
3. Select the maximum medium temperature Tm of this row, which is larger or equal to the
measured maximum medium temperature Tmm.
The column with the temperature class for gas is determined: 108 C 120C T4.
4. The maximum temperature of the temperature class determined corresponds to the maximum
surface temperature for dust: T4 = 135 C
Storage temperature 50 to +60 C (58 to +140 F) (Order code for "Test, certificate", option JM)
Process
Medium temperature range Sensor
50 to +150 C (58 to +302 F)
50 to +200 C (58 to +392 F) with extended temperature (order code for "Measuring tube mat.",
option SD, SE, SF, TH)
Seals
No internal seals
For mounting sets with screwed-on connections:
Viton:15 to +200 C (5 to +392 F)
EPDM:40 to +160 C (40 to +320 F)
Silicon:60 to +200 C (76 to +392 F)
Kalrez:20 to +275 C (4 to +527 F)
Pressure-temperature The following pressure-temperature ratings refer to the entire device and not just the process
ratings connection.
Endress+Hauser 43
Proline Promass A 100
[psi] [bar]
800
50
600 40
PN 40
400 30
20
200
10
0 0
-50 0 50 100 150 200 [C]
-50 0 50 100 150 200 250 300 350 400 [F]
A0020836-EN
21 With flange material: 1.4539 (904L), Alloy C22; lap joint flanges (not wetted): 1.4404 (F316/F316L)
[psi] [bar]
50
600 40
Class 300
400 30
20
200 Class 150
10
0 0
-50 0 50 100 150 200 [C]
-50 0 50 100 150 200 250 300 350 400 [F]
A0020920-EN
22 With flange material: 1.4539 (904L), Alloy C22; lap joint flanges (not wetted): 1.4404 (F316/F316L)
[psi] [bar]
400 30
20 K
20
200
10
10 K
0 0
-50 0 50 100 150 200 [C]
-50 0 50 100 150 200 250 300 350 400 [F]
A0020922-EN
23 With flange material: 1.4539 (904L), Alloy C22; lap joint flanges (not wetted): 1.4404 (SUS F316L)
44 Endress+Hauser
Proline Promass A 100
[psi] [bar]
440
6200
5800 400
5400
360
5000
4600 320
4200 280 DN 1
3800
3400 240
3000 200
2600
2200 160
DN 2...4
1800 120
-50 0 50 100 150 200 [C]
-80 -40 0 40 80 120 160 200 240 280 320 360 400 [F]
A0020967-EN
24 With flange connection 4-VCO-4 coupling: 1.4539 (904L); NPTF threaded adapter: 1.4539 (904L); "
or " SWAGELOK coupling: 1.4539 (904L)
[psi] [bar]
440
6200
5800 400
DN 1
5400
360
5000
4600 320
4200 280
3800
3400 240
3000 200
2600
2200 160 DN 2...4
1800 120
-50 0 50 100 150 200 [C]
-80 -40 0 40 80 120 160 200 240 280 320 360 400 [F]
A0021023-EN
25 With flange connection 4-VCO-4 coupling: Alloy C22; NPTF threaded adapter: Alloy C22; " or "
SWAGELOK coupling: 1.4539 (904L)
Endress+Hauser 45
Proline Promass A 100
[psi] [bar]
440
6200
5800 400
5400 360
5000
4600 320
4200 280
3800
3400 240
-50 0 50 100 150 200 [C]
-80 -40 0 40 80 120 160 200 240 280 320 360 400 [F]
A0020921-EN
26 With flange connection 4-VCO-4 coupling: 1.4539 (904L); NPT threaded adapter: 1.4539 (904L); "
or " SWAGELOK coupling: 1.4539 (904L)
Secondary containment The sensor housing is filled with dry nitrogen and protects the electronics and mechanics inside.
pressure rating
DN Secondary containment Secondary containment burst pressure
nominal pressure
(designed with a safety factor
4)
If there is a risk of measuring tube failure due to process characteristics, e.g. with corrosive
process fluids, we recommend the use of sensors whose secondary containment is equipped
with special pressure monitoring connections (order code for "Purge connection", option CH).
With the help of these connections, the fluid collected in the secondary containment can be
bled off in the event of tube failure. This is especially important in high-pressure gas
applications. These connections can also be used for gas purging (gas detection).
Do not open the purge connections unless the containment can be filled immediately with a
dry, inert gas. Use only low gauge pressure to purge. Maximum pressure: 5 bar (72.5 psi).
If a device fitted with purge connections is connected to the purge system, the maximum
nominal pressure is determined by the purge system itself or by the device, depending on which
component has the lower nominal pressure.
If, on the other hand, the device is fitted with a rupture disk, the rupture disk is decisive for the
maximum nominal pressure ( 46).
Dimensions: ( 62)
Rupture disk To increase the level of safety, a device version with a rupture disk with a triggering pressure of
10 to 15 bar (145 to 217.5 psi) can be used. Special mounting instructions: ( 38)
Rupture disks cannot be combined with the separately available heating jacket ( 71)
( 72).
Flow limit Select the nominal diameter by optimizing between the required flow range and permissible pressure
loss.
For an overview of the measuring range full scale values, see the "Measuring range" section
( 8)
46 Endress+Hauser
Proline Promass A 100
The minimum recommended full scale value is approx. 1/20 of the maximum full scale value
In most applications, 20 to 50 % of the maximum full scale value can be considered ideal
Select a lower full scale value for abrasive substances (such as liquids with entrained solids): flow
velocity <1 m/s (<3 ft/s).
For gas measurement the following rules apply:
The flow velocity in the measuring tubes should not exceed half the sonic velocity (0.5 Mach).
The maximum mass flow depends on the density of the gas: formula ( 8)
Pressure loss To calculate the pressure loss, use the Applicator sizing tool ( 72)
System pressure It is important that cavitation does not occur, or that gases entrained in the liquids do not outgas.
This is prevented by means of a sufficiently high system pressure.
For this reason, the following mounting locations are recommended:
At the lowest point in a vertical pipe
Downstream from pumps (no danger of vacuum)
A0015594
Thermal insulation In the case of some fluids, it is important that the heat radiated from the sensor to the transmitter is
kept to a minimum. A wide range of materials can be used for the required insulation.
A0019919
The minimum distance between the transmitter housing and the insulation is 10 mm (0.39 in) so
that the transmitter head remains completely exposed.
t
[in] [mm]
1.5 40
30
1.0
20
0.5 T40 (104)
10
T60 (140)
0 0
80 90 100 110 120 130 140 [C]
Tm
200 250 290 [F]
A0023173
Endress+Hauser 47
Proline Promass A 100
t Insulation thickness
Tm Medium temperature
NOTICE
The insulation can also be thicker than the recommended insulation thickness.
Prerequisite:
The temperature at the lower end of the transmitter housing does not exceed 80 C (176 F)
Ensure that convection takes place on a sufficiently large scale at the transmitter neck.
Ensure that a sufficiently large area of the housing support remains exposed. The uncovered part
serves as a radiator and protects the electronics from overheating and excessive cooling.
Heating Some fluids require suitable measures to avoid loss of heat at the sensor.
Heating options
Electrical heating, e.g. with electric band heaters
Via pipes carrying hot water or steam
Via heating jackets
Heating jackets for the sensor can be ordered as accessories from Endress+Hauser ( 71).
Vibrations The high oscillation frequency of the measuring tubes ensures that the correct operation of the
measuring system is not influenced by plant vibrations.
48 Endress+Hauser
Proline Promass A 100
Mechanical construction
Design, dimensions Compact version
B
C D A
E
F
G
4xM
H
I N
K O
L P
A0019424
Dimensions SI units
DN A B C D E 1) F 1) G
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
1) If using a display, order code for "Display; Operation", option B: values +28 mm
2) High-pressure version: order code for "Measuring tube material", option SG, SH, SI
DN H I K L M N O P
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
1)
1 32 160 228 4 6.5 120 145 165
1)
2 32 160 310 4 6.5 120 145 165
1)
4 32 220 435 4 6.5 150 175 195
Dimensions US units
DN A B C D E 1) F 1) G
[in] [in] [in] [in] [in] [in] [in] [in]
1) If using a display, order code for "Display; Operation", option B: values +1.1 in
2) High-pressure version: order code for "Measuring tube material", option SG, SH, SI
Endress+Hauser 49
Proline Promass A 100
DN H I K L M N O P
[in] [in] [in] [in] [in] [in] [in] [in] [in]
1)
1.26 6.3 8.98 4 0.26 4.72 5.71 6.5
1)
1.26 6.3 12.2 4 0.26 4.72 5.71 6.5
1)
1.26 8.66 17.13 4 0.26 5.91 6.89 7.68
B
C D A
E
F
G
4xM
H
I N
K O
L P
A0019425
Dimensions SI units
DN A B C D E 1) F 1) G
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
1) If using a display, order code for "Display; Operation", option B: values +14 mm
2) High-pressure version: order code for "Measuring tube material", option SG, SH, SI
DN H I K L M N O P
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
1)
1 32 160 228 4 6.5 120 145 165
1)
2 32 160 310 4 6.5 120 145 165
1)
4 32 220 435 4 6.5 150 175 195
50 Endress+Hauser
Proline Promass A 100
Dimensions US units
DN A B C D E 1) F 1) G
[in] [in] [in] [in] [in] [in] [in] [in]
1) If using a display, order code for "Display; Operation", option B: values +0.55 in
2) High-pressure version: order code for "Measuring tube material", option SG, SH, SI
DN H I K L M N O P
[in] [in] [in] [in] [in] [in] [in] [in] [in]
1)
1.26 6.3 8.98 4 0.26 4.72 5.71 6.5
1)
1.26 6.3 12.2 4 0.26 4.72 5.71 6.5
1)
1.26 8.66 17.13 4 0.26 5.91 6.89 7.68
B
C D A
E
F
4xM
H
I N
K O
L P
A0019426
Dimensions SI units
DN A B C D E 1) F 1) G
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
1) If using a display, order code for "Display; Operation", option B: values +14 mm
2) High-pressure version: order code for "Measuring tube material", option SG, SH, SI
Endress+Hauser 51
Proline Promass A 100
DN H I K L M N O P
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
1)
1 32 160 228 4 6.5 120 145 165
1)
2 32 160 310 4 6.5 120 145 165
1)
4 32 220 435 4 6.5 150 175 195
Dimensions US units
DN A B C D E 1) F 1) G
[in] [in] [in] [in] [in] [in] [in]
1) If using a display, order code for "Display; Operation", option B: values +0.55 in
2) High-pressure version: order code for "Measuring tube material", option SG, SH, SI
DN H I K L M N O P
[in] [in] [in] [in] [in] [in] [in] [in] [in]
1)
1.26 6.3 8.98 4 0.26 4.72 5.71 6.5
1)
1.26 6.3 12.2 4 0.26 4.72 5.71 6.5
1)
1.26 8.66 17.13 4 0.26 5.91 6.89 7.68
+1,5 (+0.06)
L -2,0 (-0.08)
A0015624
52 Endress+Hauser
Proline Promass A 100
4-VCO-4 coupling: 1.4539 (904L) 1)(order code for "Process connection", option HAW), Alloy C22 (order
code for "Measuring tube material", option HA)
DN A B L
[mm] [in] [mm] [mm]
1 1.1 290
2)
2 1.8 1.4 372
2)
4 3.5 3.0 497
1) 3A version available (Ra 0.8 m/150 grit, Ra 0.4 m/240 grit). Only for 1.4539 (904L) (order code for
"Measuring tube material", option SE, SF, SH, SI in combination with order code for "Additional approval"
LP)
2) High-pressure version: order code for "Measuring tube material", option SG, SH, SI
Tri-Clamp (welded)
A
+1,5 (+0.06)
L -2,0 (-0.08)
A0015625
" -Tri-Clamp: 1.4539 (904L), (order code for "Process connection", option FBW), 3A version available
(Ra 0.8 m/150 grit. optional: Ra 0.4 m/240 grit) (order code for "Measuring tube material", option
SE, SF, SH, SI in combination with order code for "Additional approval" LP)
DN A B L
[mm] [mm] [mm] [mm]
1 25 9.5 296
2 25 9.5 378
4 25 9.5 503
Endress+Hauser 53
Proline Promass A 100
X X
C
A
B
E
D
+1.5 (+0.06)
L -2.0 (-0.08)
A0019728
Mounting kit for DN 15 grooved flange according to EN 1092-1 (DIN 2501), PN 40: 1.4539 (904L)
(Order code for "Accessories", option PN), Alloy C22 (order code for "Accessories", option PO)
DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]
1 95 65 4 14 28 17.3 393
2 95 65 4 14 28 17.3 475
4 95 65 4 14 28 17.3 600
Lap joint flanges (not wetted) made of stainless steel 1.4404 (316/316L). Sealing sets: order code for
"Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
D
A
B
E
+1.5 (+0.06)
L -2.0 (-0.08)
A0019725
54 Endress+Hauser
Proline Promass A 100
Mounting kit for DN 15 flange according to EN 1092-1 (DIN 2501), PN 40: 1.4539 (904L) (order code for
"Accessories", option PE), Alloy C22 (order code for "Accessories", option PM)
DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]
1 95 65 4 14 28 17.3 393
2 95 65 4 14 28 17.3 475
4 95 65 4 14 28 17.3 600
Lap joint flanges (not wetted) made of stainless steel 1.4404 (316/316L). Sealing sets: order code for
"Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
Mounting kit for flange according to ASME B16.5, CI.150: 316/316L, 1.4539 (904L) (order code for
"Accessories", option PF), Alloy C22 (order code for "Accessories", option PP)
DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]
Lap joint flanges (not wetted) made of stainless steel 1.4404 (316/316L). Sealing sets: order code for
"Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
Mounting kit for flange according to ASME B16.5, CI.300: 316/316L, 1.4539 (904L) (order code for
"Accessories, option PG), Alloy C22 (order code for "Accessories", option PQ)
DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]
Lap joint flanges (not wetted) made of stainless steel 1.4404 (316/316L). Sealing sets: order code for
"Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
Mounting kit for flange JIS B2220, 10K: 1.4539 (904L): (order code for "Accessories", option PH);
SUS316L, Alloy C22 (order code for "Accessories", option PS)
DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]
1 95 70 4 15 28 15.0 393
2 95 70 4 15 28 15.0 475
4 95 70 4 15 28 15.0 600
Lap joint flanges (not wetted) made of stainless steel 1.4404 (316/316L). Sealing sets: order code for
"Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
Mounting kit for flange JIS B2220, 20K: 1.4539 (904L): (order code for "Accessories", option PT);
SUS316L, Alloy C22 (order code for "Accessories", option PU)
DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]
1 95 70 4 15 14 15.0 393
2 95 70 4 15 14 15.0 475
Endress+Hauser 55
Proline Promass A 100
Mounting kit for flange JIS B2220, 20K: 1.4539 (904L): (order code for "Accessories", option PT);
SUS316L, Alloy C22 (order code for "Accessories", option PU)
DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]
4 95 70 4 15 14 15.0 600
Lap joint flanges (not wetted) made of stainless steel 1.4404 (316/316L). Sealing sets: order code for
"Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
+1.5 (+0.06)
L -2,0 (-0.08)
A0019724
Mounting kit for NPTF: stainless steel 1.4539 (904L) (order code for "Accessories", option PI); Alloy
C22 1) (order code for "Accessories", option PJ)
DN A B L
[mm] [in] [in] [mm]
1 NPTF 361
2 NPTF 443
4 NPTF 568
Sealing sets: order code for "Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
+1.5 (+0.06)
L -2,0 (-0.08)
A0019726
56 Endress+Hauser
Proline Promass A 100
Mounting kit for SWAGELOK: stainless steel 1.4539 (904L) (order code for "Accessories", " option PK;
1/4" option PL)
DN A B L
[mm] [in] [in] [mm]
1 NPT 361
1 NPT 364.6
2 1) NPT 441.6
2 1) NPT 446.6
4 1) NPT 571.6
Sealing sets: order code for "Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
+1,5 (+0.06)
L -2,0 (-0.08)
A0015624
4-VCO-4 coupling: 1.4539 (904L) 1)(order code for "Process connection", option HAW), Alloy C22 (order
code for "Measuring tube material", option HA)
DN A B L
[in] [in] [in] [in]
0.043 11.4
2)
0.071 0.055 14.6
1) 3A version available (Ra 0.8 m/150 grit, Ra 0.4 m/240 grit). Only for 1.4539 (904L) (order code for
"Measuring tube material", option SE, SF, SH, SI in combination with order code for "Additional approval"
LP)
2) High-pressure version: order code for "Measuring tube material", option SG, SH, SI
Endress+Hauser 57
Proline Promass A 100
Tri-Clamp (welded)
B
+1,5 (+0.06)
L -2,0 (-0.08)
A0015625
" -Tri-Clamp: 1.4539 (904L), (order code for "Process connection", option FBW), 3A version available
(Ra 0.8 m/150 grit. optional: Ra 0.4 m/240 grit) (order code for "Measuring tube material", option
SE, SF, SH, SI in combination with order code for "Additional approval" LP)
DN A B L
[in] [in] [in] [in]
X X
C
A
B
E
D
+1.5 (+0.06)
L -2.0 (-0.08)
A0019728
Mounting kit for DN 15 grooved flange according to EN 1092-1 (DIN 2501), PN 40: 1.4539 (904L)
(Order code for "Accessories", option PN), Alloy C22 (order code for "Accessories", option PO)
DN A B C D E L
[in] [in] [in] [in] [in] [in] [in]
58 Endress+Hauser
Proline Promass A 100
Mounting kit for DN 15 grooved flange according to EN 1092-1 (DIN 2501), PN 40: 1.4539 (904L)
(Order code for "Accessories", option PN), Alloy C22 (order code for "Accessories", option PO)
DN A B C D E L
[in] [in] [in] [in] [in] [in] [in]
Lap joint flanges (not wetted) made of stainless steel 1.4404 (316/316L). Sealing sets: order code for
"Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
D
A
B
E
+1.5 (+0.06)
L -2.0 (-0.08)
A0019725
Mounting kit for DN 15 flange according to EN 1092-1 (DIN 2501), PN 40: 1.4539 (904L) (order code for
"Accessories", option PE), Alloy C22 (order code for "Accessories", option PM)
DN A B C D E L
[in] [in] [in] [in] [in] [in] [in]
Lap joint flanges (not wetted) made of stainless steel 1.4404 (316/316L). Sealing sets: order code for
"Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
Mounting kit for flange according to ASME B16.5, CI.150: 316/316L, 1.4539 (904L) (order code for
"Accessories", option PF), Alloy C22 (order code for "Accessories", option PP)
DN A B C D E L
[in] [in] [in] [in] [in] [in] [in]
Lap joint flanges (not wetted) made of stainless steel 1.4404 (316/316L). Sealing sets: order code for
"Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
Endress+Hauser 59
Proline Promass A 100
Mounting kit for flange according to ASME B16.5, CI.300: 316/316L, 1.4539 (904L) (order code for
"Accessories, option PG), Alloy C22 (order code for "Accessories", option PQ)
DN A B C D E L
[in] [in] [in] [in] [in] [in] [in]
Lap joint flanges (not wetted) made of stainless steel 1.4404 (316/316L). Sealing sets: order code for
"Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
Mounting kit for flange JIS B2220, 10K: 1.4539 (904L): (order code for "Accessories", option PH);
SUS316L, Alloy C22 (order code for "Accessories", option PS)
DN A B C D E L
[in] [in] [in] [in] [in] [in] [in]
Lap joint flanges (not wetted) made of stainless steel 1.4404 (316/316L). Sealing sets: order code for
"Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
Mounting kit for flange JIS B2220, 20K: 1.4539 (904L): (order code for "Accessories", option PT);
SUS316L, Alloy C22 (order code for "Accessories", option PU)
DN A B C D E L
[in] [in] [in] [in] [in] [in] [in]
Lap joint flanges (not wetted) made of stainless steel 1.4404 (316/316L). Sealing sets: order code for
"Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
+1.5 (+0.06)
L -2,0 (-0.08)
A0019724
60 Endress+Hauser
Proline Promass A 100
Mounting kit for NPTF: stainless steel 1.4539 (904L) (order code for "Accessories", option PI); Alloy
C22 1) (order code for "Accessories", option PJ)
DN A B L
[in] [in] [in] [in]
NPT 14.2
NPT 17.4
NPT 22.4
Sealing sets: order code for "Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
+1.5 (+0.06)
L -2,0 (-0.08)
A0019726
Mounting kit for SWAGELOK: stainless steel 1.4539 (904L) (order code for "Accessories", " option PK;
" option PL)
DN A B L
[in] [in] [in] [in]
NPT 14.2
NPT 14.4
1)
NPT 17.4
1)
NPT 17.6
1)
NPT 22.5
Sealing sets: order code for "Accessories enclosed", option P1 (Viton), P2 (EPDM), P3 (silicone), P4 (Kalrez).
Endress+Hauser 61
Proline Promass A 100
C
A
B D
A0016777
A B C D
Accessories
C
A 45
F
F
E
B
A0019675
Dimensions in SI units
DN A B C D E F
[mm] [mm] [mm] [mm] [mm] [mm] [in]
Dimensions in US units
DN A B C D E F
[in] [in] [in] [in] [in] [in] [in]
62 Endress+Hauser
Proline Promass A 100
Weight in SI units
All values (weight) refer to devices with EN/DIN PN 40 flanges. Weight information in [kg].
DN Weight [kg]
[mm]
1 8
2 9
4 13
Weight in US units
All values (weight) refer to devices with EN/DIN PN 40 flanges. Weight information in [lbs].
DN Weight [lbs]
[in]
1/24 18
1/12 20
1/8 29
3
A0020640
Endress+Hauser 63
Proline Promass A 100
Device plug
Sensor housing
Acid and alkali-resistant outer surface
Stainless steel 1.4301 (304)
Measuring tubes
Stainless steel, 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Surface quality:
Not polished
Ramax = 0.8 m (32 in)
Ramax = 0.4 m (16 in)
Process connections
VCO coupling
Stainless steel, 1.4539 (904L)
Alloy C22, 2.4602 (UNS N06022)
Tri-Clamp
Stainless steel, 1.4539 (904L)
Mounting kit, flanges as per EN 1092-1 (DIN 2501), ASME B16.5, JIS B2220
Stainless steel, 1.4539 (904L)
Alloy C22, 2.4602 (UNS N06022)
Mounting kit, lap joint flanges as per EN 1092-1 (DIN 2501), ASME B16.5, JIS B2220
Stainless steel, 1.4404 (316/316L)
Mounting kit, SWAGELOK
Stainless steel, 1.4539 (904L)
Mounting kit, NPTF
Stainless steel, 1.4539 (904L)
Alloy C22
List of all available process connections ( 65)
64 Endress+Hauser
Proline Promass A 100
Seals
Welded process connections without internal seals
Seals for mounting kit
Viton
EPDM
Silicone
Kalrez
Operability
Operating concept Operator-oriented menu structure for user-specific tasks
Commissioning
Operation
Diagnostics
Expert level
Quick and safe commissioning
Individual menus for applications
Menu guidance with brief explanations of the individual parameter functions
Reliable operation
Operation in the following languages:
Via "FieldCare" operating tool:
English, German, French, Spanish, Italian, Chinese, Japanese
Via Web browser:
English, German, French, Spanish, Italian, Dutch, Portuguese, Polish, Russian, Turkish, Chinese,
Japanese, Bahasa (Indonesian), Vietnamese, Czech
Uniform operating philosophy applied to operating tools and Web browser
If replacing the electronic module, transfer the device configuration via the plug-in memory
(HistoROM DAT) which contains the process and measuring device data and the event logbook. No
need to reconfigure.
For devices with Modbus RS485, the data recovery function is implemented without the plug-in
memory (HistoROM DAT).
Efficient diagnostics increase measurement availability
Troubleshooting measures can be called up via the operating tools and Web browser
Diverse simulation options
Status indicated by several light emitting diodes (LEDs) on the electronic module in the housing
compartment
Local display The local display is only available with the following device version:
Order code for "Display; Operation", option B: 4-line; via communication
Display element
4-line liquid crystal display with 16 characters per line.
White background lighting; switches to red in event of device errors.
Format for displaying measured variables and status variables can be individually configured.
Permitted ambient temperature for the display: 20 to +60 C (4 to +140 F). The readability of
the display may be impaired at temperatures outside the temperature range.
Endress+Hauser 65
Proline Promass A 100
4 6 7
1 2 3 5
A0016948
1 2 3 4
A0016961
1 Ethernet network
2 Automation system, e.g. "RSLogix" (Rockwell Automation)
3 Workstation for measuring device operation: with Add-on Profile Level 3 for "RSLogix 5000" (Rockwell
Automation) or with Electronic Data Sheet (EDS)
4 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
5 Ethernet switch
66 Endress+Hauser
Proline Promass A 100
1 2
4 4 4
A0020903
1 Automation system
2 Computer with PROFIBUS network card
3 PROFIBUS DP network
4 Measuring device
HART
1
A0016926
42 Connection for the order code for "Output", option B: 4-20 mA HART, pulse/frequency/switch output
1 Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server
2 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
3 Standard Ethernet connecting cable with RJ45 plug
Endress+Hauser 67
Proline Promass A 100
PROFIBUS DP
1
A0021270
EtherNet/IP
1
A0016940
68 Endress+Hauser
Proline Promass A 100
2 1
A0016925
C-Tick symbol The measuring system meets the EMC requirements of the "Australian Communications and Media
Authority (ACMA)".
Ex approval The measuring device is certified for use in hazardous areas and the relevant safety instructions are
provided in the separate "Safety Instructions" (XA) document. Reference is made to this document on
the nameplate.
The separate Ex documentation (XA) containing all the relevant explosion protection data is
available from your Endress+Hauser sales center.
ATEX/IECEx
Currently, the following versions for use in hazardous areas are available:
Ex ia
Category (ATEX) Type of protection
Ex nA
Category (ATEX) Type of protection
CCSAUS
Currently, the following versions for use in hazardous areas are available:
IS (Ex i)
Class I Division 1 Groups ABCD
Class II Division 1 Groups EFG and Class III
Endress+Hauser 69
Proline Promass A 100
NI (Ex nA)
Class I Division 2 Groups ABCD
Modbus RS485 certification The measuring device meets all the requirements of the MODBUS/TCP conformity test and has the
"MODBUS/TCP Conformance Test Policy, Version 2.0". The measuring device has successfully passed
all the test procedures carried out and is certified by the MODBUS/TCP Conformance Test
Laboratory of the University of Michigan.
EtherNet/IP certification The measuring device is certified and registered by the ODVA (Open Device Vendor Association).
The measuring system meets all the requirements of the following specifications:
Certified in accordance with the ODVA Conformance Test
EtherNet/IP Performance Test
EtherNet/IP PlugFest compliance
The device can also be operated with certified devices of other manufacturers (interoperability)
Ordering information
Detailed ordering information is available from the following sources:
In the Product Configurator on the Endress+Hauser website: www.endress.com Select country
Instruments Select device Product page function: Configure this product
From your Endress+Hauser Sales Center: www.endress.com/worldwide
70 Endress+Hauser
Proline Promass A 100
Application packages
Many different application packages are available to enhance the functionality of the device. Such
packages might be needed to address safety aspects or specific application requirements.
The application packages can be ordered from Endress+Hauser either directly with the device or
subsequently. Detailed information on the order code in question is available from your local Endress
+Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com.
Accessories
Various accessories, which can be ordered with the device or subsequently from Endress+Hauser, are
available for the device. Detailed information on the order code in question is available from your
local Endress+Hauser sales center or on the product page of the Endress+Hauser website:
www.endress.com.
Endress+Hauser 71
Proline Promass A 100
Accessories Description
Heating jacket Is used to stabilize the temperature of the fluids in the sensor.
Water, water vapor and other non-corrosive liquids are permitted for use as fluids.
If using oil as a heating medium, please consult with Endress+Hauser.
Heating jackets cannot be used with sensors fitted with a rupture disk.
For details, see Operating Instructions BA00099D
HART Loop Converter Is used to evaluate and convert dynamic HART process variables to analog current
HMX50 signals or limit values.
For details, see "Technical Information" TI00429F and Operating Instructions
BA00371F
Wireless HART adapter Is used for the wireless connection of field devices.
SWA70 The WirelessHART adapter can be easily integrated into field devices and existing
infrastructures, offers data protection and transmission safety and can be operated
in parallel with other wireless networks with minimum cabling complexity.
For details, see Operating Instructions BA00061S
Fieldgate FXA320 Gateway for the remote monitoring of connected 4-20 mA measuring devices via a
Web browser.
For details, see "Technical Information" TI00025S and Operating Instructions
BA00053S
Fieldgate FXA520 Gateway for the remote diagnostics and remote configuration of connected HART
measuring devices via a Web browser.
For details, see "Technical Information" TI00025S and Operating Instructions
BA00051S
Field Xpert SFX350 Field Xpert SFX350 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
Fieldbus devices in the non-Ex area.
For details, see Operating Instructions BA01202S
Field Xpert SFX370 Field Xpert SFX370 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
Fieldbus devices in the non-Ex area and the Ex area.
For details, see Operating Instructions BA01202S
72 Endress+Hauser
Proline Promass A 100
Commubox FXA291 Connects Endress+Hauser field devices with a CDI interface (= Endress+Hauser
Common Data Interface) and the USB port of a computer or laptop.
For details, see "Technical Information" TI00405C
Memograph M graphic The Memograph M graphic display recorder provides information on all relevant
display recorder measured variables. Measured values are recorded correctly, limit values are
monitored and measuring points analyzed. The data are stored in the 256 MB
internal memory and also on a SD card or USB stick.
For details, see "Technical Information" TI00133R and Operating Instructions
BA00247R
iTEMP The temperature transmitters can be used in all applications and are suitable for
the measurement of gases, steam and liquids. They can be used to read in the fluid
temperature.
For details, see "Fields of Activity", FA00006T
Documentation
For an overview of the scope of the associated Technical Documentation, refer to the following:
The CD-ROM provided for the device (depending on the device version, the CD-ROM might
not be part of the delivery!)
The W@M Device Viewer : Enter the serial number from the nameplate
(www.endress.com/deviceviewer)
The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the
2-D matrix code (QR code) on the nameplate.
Operating Instructions
Documentation code
Endress+Hauser 73
Proline Promass A 100
ATEX/IECEx Ex i XA00159D
ATEX/IECEx Ex nA XA01029D
cCSAus IS XA00160D
INMETRO Ex i XA01219D
INMETRO Ex nA XA01220D
NEPSI Ex i XA01249D
NEPSI Ex nA XA01262D
Special Documentation
Installation Instructions
Installation Instructions for spare part sets Specified for each individual accessory
( 71)
Registered trademarks
HART
Registered trademark of the HART Communication Foundation, Austin, USA
PROFIBUS
Registered trademark of the PROFIBUS User Organization, Karlsruhe, Germany
Modbus
Registered trademark of SCHNEIDER AUTOMATION, INC.
EtherNet/IPTM
Trademark of ODVA, Inc.
Microsoft
Registered trademark of the Microsoft Corporation, Redmond, Washington, USA
TRI-CLAMP
Registered trademark of Ladish & Co., Inc., Kenosha, USA
SWAGELOK
Registered trademark of Swagelok & Co., Solon, USA
Applicator, FieldCare, Field XpertTM, HistoROM, Heartbeat TechnologyTM
Registered or registration-pending trademarks of the Endress+Hauser Group
74 Endress+Hauser
www.addresses.endress.com