Function Introduction---------------------------------------------------2 1. 100 wireless and 8 wire defense zones.
Installation and commissioning-------------------------------------------3 2. At most 8 wireless remote control codes.
Host installation--------------------------------------------------------3
Magnetic door sensor Installation------------------------------------6 3. Blue backlighting graphic display for clear information.
Infrared installation----------------------------------------------------7 4. 6 groups of voice alarm phones (mobile phone), and 2 groups of phones in alarm
System installation-----------------------------------------------------8
Function Settings---------------------------------------------------------10 receipt center.
Recovery password----------------------------------------------------11 5. Built-in perpetual calendar and clock; automatic logging of alarm cases by time
Factory defaults-------------------------------------------------------11
Enter setting-------------------------------------------------------------12 sequence.
Exit setting--------------------------------------------------------------12 6. Message recording playback: human recording, synchronous playback for
Remote control code set---------------------------------------------12
Delete remote control settings-------------------------------------13 recording effect in audition.
Code Defense Zone --------------------------------------------------13 7. More defense modes: remote defense, keypad defense, and non-local remote
Delete Defense Zone-------------------------------------------------13
Change password------------------------------------------------------14 defense by telephone; stay-in defense, timing defense, and individual defense in
User code set----------------------------------------------------------14 zones.
Year, month, day, hour, minute setting---------------------------15
Host keypad lock settings------------------------------------------15 8. Programming of defense zone type: all zones could be programmed via keypad
Wireless devices encoding settings-------------------------------15 for immediate, delayed, 24-hour and bypass alarm modes.
Timing arm setting----------------------------------------------------16
Timing disarm setting------------------------------------------------16 9. Alarm Position Programming: Intelligent automatic speech recognition: SOS
Timing switch setting-------------------------------------------------16
Alarm call settings---------------------------------------------------17 alarm, fire alarm, gas leak, magnetic contact alarm, hall alarm, window alarm,
Delete call settings--------------------------------------------------17 balcony alarm, and perimeter alarm
Telephone extension setting----------------------------------------17
Center phone setting--------------------------------------------------18 10. Timing defense and disarm: host features automatic timing defense and disarm.
Delete center phone setting------------------------------------------18 11. Intelligent Music Alarm: full voice prompt. During defense at home, host music
Defense zone type setting-------------------------------------------18
Left-in defense zone setting-----------------------------------------19 and voice alarm, external siren mute; during defense in the absence, host voice
Artificial recording---------------------------------------------------19 alarm, loud external siren alarm.
Recording playback-------------------------------------------------19
Remote control settings--------------------------------------------20 12. Password Recovery: Whether the host is in defense or disarm, the lost password
Frequency of rings setting of remote incoming call----------20 can be recovered.
Open network settings------------------------------------------------20
Arm/disarm operation report center setting------------------------20 13. Intelligent learning code: intelligent learning code, newly added with detector
Warning signal tone setting----------------------------------------21
Disconnection detection settings---------------------------------21 which is prompt and efficient, and convenient and simple.
Out arm delay time setting. -----------------------------------------21 14. Host status memory: automatic host memory for defense and disarm, which
Information Inquiry--------------------------------------------------22
could enable the host to automatically recover defense or disarm before power
Operation Instruction------------------------------------------------23
Maintaining--------------------------------------------------------------25 cut after the reset upon power cut or shut down.
Technical Parameter-------------------------------------------------27 15. Event Log Query: host automatically records 45 pieces of all information
concerning defense, disarm and alarm events.
16. Line priority alarm: the host will cut the busy call and switch to priority alarm in
case of the alarm during ongoing call, no matter incoming or outgoing call.
17. Phone disconnection detection: automatic detection and alarm warning in line
disconnection, for anti-sabotage of telephone lines.
18. Remote control: through remote phone (cell phone) dial-up, many operations
could be realized, like defense, disarm and on-site monitoring by the host in the
remote control form.
19. The time delay of out arm could be set at will.
20. Host is equipped with battery box, with optional AAA NI-HM rechargeable
battery. Host meets 3C safety standards and national standard GB12663-2001
21. Compatible with internationally accepted protocol of alarm receipt center:
ADEMCO Contact ID alarm communication protocol.

debugging]]
[Installation and debugging Display:

1. Host Installation
The host shall be installed in the centre of the prevent site which could realize
best receiving effect from all wireless detectors. Please note that keep the host
away from large-sized metallic objects and home appliances producing
high-frequency interference, and avoid steel-reinforced concrete and fire-proof
doors.

Rear installation:
Control panel:
10). Then the alarm host will be firmly installed in the fixed position, and the screws
are tightened.
11). Finally walk test is performed.
Cable defense zone:

Installation:
1). The host is positioned for installation so that it locates in the range of detector Wiring:
protection of alarm system. 1). Four-core signal lines will be laid in advance between the host and installation
2). Fixed hold size by host rear screw, and tighten screws in installation position. location of cable detector.
3). Open host battery cover, put dedicated rechargeable battery pack into the box, align 2). Open the shell of cable detector, and connect four-core signal lines by colors
power cable pin and finally cover battery box. respectively into detector terminals. Power input (red line for power positive while
4). Line connection: LINE is connected with the incoming telephone; TEL is connected black line for negative), and signal output (white for NO / NC while blue for GND).
with telephone set. Please note that Do not connect the line improperly, otherwise no Fix and install cable detector.
outgoing alarm calls are available. 3). Loosen the screw terminals of host cable defense zones with a screwdriver, and
5). Loud alarm connection: the host alarm output (SP +) is connected with loud alarm then connect four-core detector signal lines respectively to the defense port (white for
positive (white line); the negative (black line) is connected with the host grounding (GND). Z1 while blue for GND), and power port (red for DC12V output while black for
Please note that Do not connect positive and negative improperly, otherwise the alarm GND); it is tightened.
does not sound and will be damaged. 4). Other detectors will be subject to the same connection, and note that the power
6). Installation method for cable detector: please follow cable zone connection instructions supply is aligned to the power supply while the signal is aligned to the signal.
in the next. 5). The alarm system has 8 cable defense zones, respectively for 8 different types of
7). Power Access: power output head (elbow) with power adapter will be directly inserted cable detectors.
into the power input hole (DC12V IN) on the host. 6). If you access more than 8 cable detectors, detector signal lines in the adjacent
8). Detailed examination will be performed to check whether all the connections are correct, position with the same type can be installed subject to series connection into one zone.
and cable access is fixed and reliable. Regardless of which detector is triggered, the host will alarm, but the alarm is just the
9). All connecting lines will be included into the host's rear lead hole slot. same zone.
Wireless remote control 5). Fix the sender in the door (window) frame, and tighten it with screws if
Structure chart: required.
6). Fix magnet bar on the door (window) leaf, and tighten it with screws if
required.
7). Installation of the sender and magnet bar shall be leveled with the spacing
less than 3 ~ 5mm.
8). When installed in metal doors and windows, if the wireless is ineffective,
it is recommended to elevate and fix the sender and magnet bar, or wireless
2. Magnetic Contact Detector Installation
iron magnetic contact detector is selected.
Wireless magnetic contact detector with multi-functions: emergency button, vibration
3. Infrared installation
detection and magnetic contact switch. It is suitable for outdoor or door and window
To avoid false alarms, wireless infrared detector must be installed indoors, and
installation, with reliable performance and no false alarm, which is most common.
outdoor use is strictly prohibited.
Once the door or window is opened, the sender is separated from magnet bar, and then
Wireless infrared detector is the most common indoor detector in alarm system. The
wireless alarm signal will be activated and sent (magnetic contact alarm lights) .
detection range covers the space with horizontal 110 , Vertical 70 , and detection
Structure chart:
range of 12 meters. Infrared radiation light of mobile body will be focused and
Antenna transmitted through the Fresnel lens to the sensor, and then wireless infrared detector
Vibration
will launch a wireless alarm signal outsides (alarm light on lens flashes).
Alarm light switch
Structure chart
Sender Reed switch

Magnet bar Emergency

button

Coding

Battery

Installation:
1). First, install batteries of wireless magnetic contact detector, and then code
the host.
2). Choose a sturdy door or window with a clean surface.
3). Trigger repeatedly wireless magnetic contact detector in the installation
position to check whether the host is able to receive the signal normally; to
identify the host can be sensitive to receive the alarm prior to continuous Detection range:
installation. Otherwise, the position for magnetic contact detector or host
shall be adjusted.
4).The double-sided adhesive will respectively be stuck to the rear of sender
and magnet bar.
6). Repeated walk tests: to constantly adjust the detection direction and angle,
Overhead detection range: Side detection range:
and test all locations to be protected; in all three steps sensitive detection and
Horizontal
Vertical alarm must be realized.
Detection
7). Special attention shall be paid to prevent dirt or scratch from Fresnel lens.
distance
4. System installation
The detector for alarm apparatus, in order to guarantee the detection results, shall
provide relatively high sensitivity; Because of this, the detector, if installed properly,
Detection range of infrared detector covers the tetragonal pyramid will easily lead to false alarm. Therefore, the installation must be subject to the
space with horizontal 110 , Vertical 70 , and effective distance of 8-12 following details:
meters. 1). Outdoor (balcony) defense must be subject to special detector for
Installation: magnetic contact, vibration, correlation, fence or outdoor use; it is
1). Open the battery cover of wireless infrared detector, insert the prohibited to install wireless infrared detectors outdoors.
battery in the correct direction and code the host. Companied carbon 2). Doors and windows defense shall be subject to magnetic contact and
batteries, perhaps because of too long leaving from the factory, can vibration detectors, other than infrared detectors. Because of constraints,
only be used to test machine; during installation, it is recommended if infrared detector must be used to replace magnetic contact, curtain
to install AAA alkaline batteries , in order to guarantee long term detector with direction can be selected and must be installed in the inside
stability of wireless infrared detector. of doors and windows.
2). Select installation location, and then fix the bracket of wireless 3). Indoor defense shall be generally subject to infrared detector or curtain
infrared detector to installation point with screws; the installation detector. It is recommended to, during installation, strictly follow
height must be 2.20 ~ 2.50 meters. installation method for infrared detectors.
3). In this position repeatedly trigger wireless infrared detector to check 4). Wireless infrared detector must be installed in the interior hidden
whether the host is able to receive the signal; to identify the host backlight place; it is necessary to avoid facing the doors and windows, air
could be sensitive and sound alarm, and then install it. Otherwise, conditioning, heating apparatus, and ventilation etc., which due to
the distance or location of wireless infrared detector or the host obvious change of temperature and air flow will caused false alarms of
shall be adjusted. infrared detector.
4). Note that the direction tangency between detection and body movement must 5). Direct light on Fresnel lens of infrared detector will be likely to cause
be achieved (90 degrees from the vertical direction), with the most sensitive false alarms. Vibration source near infrared detector can also cause false
and best detection effect. Otherwise, the detection is ineffective. alarms.
5). Overhead view of infrared detector shall be adjusted higher, with 6). Indoor wireless infrared detectors shall keep away from appliances with
30cm above the ground avoided in case of pet; meanwhile, attention strong electromagnetic interference (such as computers, televisions, air
shall be paid to avoid the mice crawling in front of infrared detector; conditioners, microwave ovens etc); otherwise, there may be false
this can prevent false alarms caused by pets. alarms.
7). Indoor infrared detectors shall keep away from mice crawling to prevent repeatedly triggered to ensure that in each trigger, the host can properly
false alarms caused by the mice. receive the signal and sound alarm.
8). Overhead view of infrared detector shall be adjusted higher, with 30cm 4). Detection range of wireless infrared detector: in the effective range of
above the ground avoided in case of pet; this can prevent false alarms wireless infrared detector, select a different location in different directions,
caused by pets. with walk test method for testing. In three steps, it must be guaranteed that
9). The battery of wireless infrared detector shall be regularly examined, to wireless infrared detectors can be sensitive and sound alarm.
prevent the battery under-voltage from false alarms. AAA alkaline battery 5). Walk test would be used to constantly adjust the left and right directions and
must be selected for battery replacement. overhead view of wireless infrared detector to achieve maximum detection
Installation diagram: range, and the most sensitive detection results.
Magnetic contact detector Host
Horizontal detection Infrared detector 6). Check front space of wireless infrared detectors and make sure there is no
angle
Door frame object (curtain) or glass wall. Otherwise, it will reduce the detection effect of
Door leaf
the detector.
Magnet bar
7). Alarm host and all accessories must be in the range of effective warning in
alarm system, and can not easily be able to destroy and shut down them.
Magnetic contact sender
2.2-2.5m
detector
Installation height of infrared
Functions]]
[Set Functions
Window frame

Window leaf Preparation


Magnet bar
The batteries for remote control, wireless magnetic contact detector and wireless
Anti pet height
Walk direction
infrared detector shall be respectively installed and then corresponding parameters
Magnetic contact sender
Magnetic contact detector shall be adjusted for use (the machine features 315MHz frequency, 2262 coding and
4.7M oscillation resistance).
Walk test Connect the host with telephone lines, telephone, cable detector and external siren
After alarm system is installed, each installed accessory must be tested to fully according to the host installation diagram. Electrify DC 12 V power adapter. And
understand the alarm performance. If the result is not satisfactory, please adjust the LCD display and all LED lights on the host are on and the speaker sounds a long beep;
device in the following ways: after 2 seconds all LED lights go off except power indicator; LCD display the disarm
1). Signal emission of wireless remote control: check whether all remotes could and standby status
normally operate the host; and each button of remote control can work. LCD display:
2). Signal emission of wireless magnetic contact detector: wireless magnetic
contact detector is repeatedly triggered to ensure that in each trigger, the host
can properly receive the signal and sound alarm.
3). Signal emission of wireless infrared detector: wireless infrared detector is
Prompt tone Engineering password is [66666666
6666]
During operation, the host will sound different tones, representing different 0321456988
Operating:0321456988
0321456988# #
operating information: 2. Factory defaults
Prompt tone Information 0321456987
In Settings state, enter [0321456987
0321456987]on the key directly, and then press [#] to confirm;
One short beep Valid button (0.5 second) then all LED lights on the host are on for 2 seconds and the speaker sounds a long
One long beep Recover factory settings, correct and valid beep. All settings on the host are cleared and return to original factory state.
settings (1.5 seconds) 0321456987
Operating:0321456987
0321456987# #
beep, beep Disarm prompt tone (1 second) 3. Enter Setting
Three short beep Invalid and wrong operation and settings (0.5 Only in setting state, function settings and operations could be performed on the
second) host.
One short beep for Absence defense or delay defense (0.5 In disarm state, enter four-digit [Password] with key pad and then press [ # ] key to
one second second) confirm; Host voice prompt: please enter instruction, and [Set Set
Set] indicator light will
always light , entering the system setting status. hosts original factory engineering
Starting up and disarm 6666
password is [6666
6666].
If the host is electrified and in arm state (LCD display locked icon, ARM
ARM Home
ARMorHome
Home Password #
Password
Operating:Password
light,we must disarm the host: Press remote control [ ] key to disarm ; or through the 4. Exit Setting
host keyboard , if the host keyboard lock function is off , when you want to disarm , When the function is set up, or it is in the setting state ([SET] indicators light forever),
Press the disarm button directly [ ] can be realized disarm ; host keyboard lock press [*],[#] keys to exit setting mode, [SET] light is off, host returns to disarm state.
function is on, you need to press [ ], then input user password according to the voice You can set all functions continuously after enter the settings. Just press [#], If you
prompts , input [#] key to confirm. . Host voice prompts: the system is disarmed. input error or command skipping. However, if in the process of setting operation,
Remote disarm :press [ ] key once stop key timeout 20 seconds, the host will automatically exit the setup to return to
Host Disarm : [ disarm ] ( keyboard lock off ) or [ disarm ] + [ user's the disarmed state
password ] (keyboard lock on) Operating:* * + # #

5. Remote coding
1. Password recovery All remote controls must be coded with the host for normal remote control and
If the password is lost or forgotten, please use the [Recover password] command operation.
to recover password to original state. In Settings state, first enter the address code [20] by host keypad, then select remote
0321456988
In arm or disarm, press [0321456988
0321456988] number keys on the host keyboard, and finally number [1]~[8] and finally press [#] to confirm; [Signal] always lights, LCD displays
#] key to confirm; Host [Signal
press [# Signal
Signal] indicator flashes once, and the speaker sound a coding icon and press any key to send a wireless signal on remote control to be coded;
1234
long "beep". User password is cleared, and it is recovered to the original [1234
1234]. after the host receives the signal, [Signal] light goes off, and voice prompts: coding
successfully, please enter instruction. 23
Operation:23 01
2301 #
01#
A##
Settings:20A LCD display:
A means: [1]~[8] remote serial numbers; it could be coded at most 8
remote controls .
Example: A remote control code in the position of the 1st operating
Operation:2011## 8. Delete defense zone
LCD display: Once wireless detector of the defense zone is deleted, it never triggers the host for
the alarm.
In Settings state, first enter address code [23] by host keypad, then select defense zone
number [01] ~ [99] to be deleted and finally press [#] to confirm; voice prompts:
delete successfully, please enter instruction.
6. Delete remote control 24
Settings:24 XX
24XX #
XX#
Once remote control is deleted, no operation could be performed on alarm XX: [01]~[99] respectively corresponds defense 01 to 99.
In Settings state, first enter [21] by keypad, then select remote serial number to be Example: delete 1 defense zone of wireless magnetic contact in defense from the host
deleted and finally press [#] to confirm; [Signal] flashes once, and voice prompts: 24
Operation:24 01
2401 #
01#
deleted successfully, please enter instruction. 9. Change password
21
Settings method:21 A##
21A 1). Change user password
A: [1] ~ [8] remote serial numbers; it could be coded at most 8 remote controls User password is the key to enter the system to operate host disarm or remote
Example: delete No. 3 remote control from alarm host control.
2133##
21
Operation:21 In Settings state, first enter address code [30] by host keypad, then enter new
7. Defense coding four-digit password and finally press [#] to confirm; voice prompts: set successfully,
All wireless detectors must be coded with corresponding zones on the host to please enter instruction.
trigger host alarm. 30
Settings:30 XXXX
30XXXX #
XXXX#
In Settings states, first enter address code [23] by host keypad, then select appropriate XXXX: new four-digit password.
defense zone number [01] ~ [99] and finally press [#] to confirm; the indicator light of Example: change password : 1012
defense zone will always light, LCD displays the corresponding defense zone number, 30
Operation:30 1012
301012 #
1012#
trigger and send a wireless signal on wireless detector to be coded; after the host 2). Change Engineer password
receives the signal, the indicator light of defense zone goes off, and voice prompts: The engineering password is the necessary key to enter system for host function
coding successfully, please enter instruction. setting..
setting
23
Settings:23 XX##
XX
23XX In setting state, first enter address code [31] key , then enter the new four-digit
XX: [01]~[99] respectively corresponds defense 01 to 99. password , and finally add the [ # ] key to confirm ; host " tick " a long sound ,
Example: Wireless magnetic door code operating in 1defense zone. voice prompts " set successfully " , the password successfully modified .
Operating: [31] [XXXX] [#]
XXXX: the four-digit new password.
For example: change the password :2846 ;
Operation : [31] [ 2846 ] [ # ]
Note : The engineering password and user password can not be set to the same
four-digit number 12. Keypad lock setting
10. User code setting Keypad lock could help the host password can not be changed maliciously.
User code will identify each user's ID number when network the computer In setup state, press [35] [0//1]
[35], then input [0 1], finally press [#] to confirm. Host makes a
center. long beep. A voice prompt: setting completed, please enter instruction.
In Settings state, first enter address code [32] by host keypad, then enter four-digit Operating35
35 X#
35X #
user code and finally press [#] to confirm; voice prompts: set successfully, please enter X=
X=0 indicates Keypad lock is off. Arming/disarming, password dont need to be entered
instruction. X= 1 indicates: Keypad lock is on. Arming/disarming, password should be entered.
Settings:3232
32 XXXX
XXXX
XXXX ## Example Open the keypad lock
XXXX: four-digit user code: ID number. Operating35
35 1#
351 #
Example: specific operation: user code of Mr. Smith is 0005
Operation:32 32
32 0005
0005
0005 ## 13. Wireless Equipment Coding Setting
11. Date and time settings The code need to be same as the code of wireless alarm, if it could be work with
Year, month, day, hour and minute must be set up in the correct way; otherwise, alarm system when alarm
alarm.
leap year and month will run an error! In setup status, press [36] + 8 wireless equipment coding, then enter [#] to confirm.
In Settings state, first enter address code [34] by host keypad, then enter later two Host make a long beep. A setting completed, please enter the instruction voice
AA];two digits of current month[BB
digits of this current year[A BB
BB],then enter current day prompt appears.
CC
[CC
CC],enter current hour (24-hour)[DD DD
DD]and current minutes[EEEE
EE], finally press [#] to Wireless equipment coding include sc2262 coding four data bits, and 8 address
confirm; voice prompts: set successfully, please enter instruction. Operating method36 36 XXXXXXXX
36XXXXXXXX
XXXXXXXX# #
Settings method:34AA AA
AABB BB
BBCC CC
CCDD DD
DDEE EE
EE# # XXXXXXXX indicates8 8 wireless equipment coding
AA: later two digits in current year. Example: detailed operating of wireless equipment coding is01020102
01020102
01020102
BB: current month Operation:36 3601020102#
36 #
CC: current day 14. Timed Arm
DD: current hour Timed arm or disarm is convenient to arm or disarm at the necessary time.
EE: current minutes In setup status, press [37] XX
[37], and then input Hour of arming time [XX
XX] in every time ,and
2012.011.01
Example: operating of 2012.0 01..12
12::00 then input minute of arming time[YY YY
YY], finally press [#] to confirmed. Host make a
Operation:34 34
34 12 12
12001 0101 12
01 12
12 00 00
00# # long beep. A setting completed, please enter instruction voice prompt appears.
LC D display: Operating: 37 37
37 XX XX
XX YY YY
YY # #
XX indicates: arming timehour ]~[
]~[56]], finally press [#] to confirm. The main host makes a
In setup status, enter [51]~[
YY indicates: arming timeminute long beep, the [signal] flash at the same time. You will hear a voice prompt: deleted
Example: set arm at 18:55 in every day automatically successful, please enter instruction.
Operation: 37
37 18
3718 55##
55
1855 Operating: XX
XX #
XX #
15. Timed Disarm XX indicates: 1-6 alarming user number [51]~[56]
Timed arm or disarm is convenient to arm or disarm at the necessary time. Example: The third group alarm phone number is deleted
In setup status, press [38] XX
[38], and then input Hour of arming time [XX
XX] in every time ,and Operation: 53
53 #
53 #
YY
then input minute of arming time[YY
YY], finally press [#] to confirmed. Host make a 19. Extension Telephone Setting
long beep. A setting completed, please enter instruction voice prompt appears. If the host is connected to the telephone line extension through the telephone exchange;
Operating: 38
38 XX
38 XX YY
XX YY ##
YY in phone number settings, external outgoing line number would be required (external
XX indicates: arming timehour outgoing line number: refers to additional figure, generally 0 or 9 in exchange,
YY indicates: arming timeminute selected for external outgoing dialing through telephone extension).
Example: set disarm at 08:30 in every day automatically In Settings, first enter address code [51]~[56]
[51]~[56], enter external outgoing line number 0
Operation: 38
38 08
3808 30##
30
0830 or 9, then enter phone (mobile) number and finally press [#] to confirm; voice prompts:
16. Timed Arm and Disarm Function Open or Closed set successfully, please enter instruction.
Timed arm and disarm function open: timed arm and disarm is effective, in XX
Settings:XX A
XX A
YY
YY
YYYY #
YY #
contrary, it is will not. A: external outgoing line number of phone exchange extension.
[399], then input [0/1]
In setup status, press [3 [0/1], finally press [#] to confirmed. Host make a YY
YYYY: phone number, without digit limit, even applicable to long
long beep. A setting completed, please enter instruction voice prompt appears. distance.
Operation: 39X# 9 in external outgoing calls with alarm
Example: on extension, dial up another 9
X=0 indicates: Timed arm and disarm function open phone number of 888888888
X=1 indicates: Timed arm and disarm function closed 9888888888
Operation:519 888888888 #
888888888#
17. Alarm Number Setting 20. Call Number of Alarm Receiving Center Setting
In setup status, enter [51]~[56]
[51]~[56], then input phone number, finally press [#] to confirm. For host alarm at online status, it is necessary to set the telephone number of
The main host makes a long beep, the [signal] flash at the same time. You will hear a computer alarm receipt center to upload data communications.
voice prompt: setting completed, please enter instruction. In Settings, first enter address code [57]~[58]
[57]~[58], enter telephone number of computer
Operating: XX
XX YY
XX YY
YYYY ##
YY alarm receipt center and finally press [#] to confirm; voice prompts: set successfully,
XX indicates: 1-6 alarming user number [51]~[56] please enter instruction.
YY
YYYY indicates: voice alarm-receiving phone number YY
Settings:XXYY
YYYY #
YY#
Example: set 13811111111 to be first group alarm phone number 57
XX: address code [57 58
57] or [58
58] for first or second telephone number of
Operation: 5113811111111
13811111111##
13811111111 computer alarm receipt center.
18. Delete Alarm Number Setting YY
YYYY
YY: telephone number of computer alarm receipt center.
Example: set 88000000 as the first telephone number of alarm receipt center Home (stay-in) defense: some defense zones of the alarm are valid while others
88000000##
88000000
Operation:5788000000 are invalid.
21. Delete Call Number of Alarm Receiving Center Setting In Settings, first enter address code [61], select corresponding defense zone number
In Settings, first enter address code [57] -[58] and directly press [#] to confirm; [01] - [99], and whether to choose alarm [0/1] in [Home arm] and finally press [#] to
telephone number of alarm receipt center is deleted from the console. Voice prompts: confirm; voice prompts: set successfully, please enter instruction. Factory settings: [0]:
delete successfully, please enter instruction. no alarm for home (stay-in) defense zone.
XX
Settings:XX ##
XX 61
Settings:61 XX
61XX A#
XXA #
Example: delete the first and second telephone numbers of computer alarm receipt XX: [01]~[99] corresponds to defense 01 to 99.
XX
centers; 0] for no alarm during stay-in defense while [1
A: [0] 1] for alarm during stay-in
57
Operation:57 ##
57 defense..
58
58 ##
58 Example: set 10 defense zones as home (stay-in) defense alarm.
22. Defense zone type 61
Operation:61 10
6110 1#
101 #
In Settings, first enter address code [60]
[60], select corresponding defense zone number Example: modify 55 defense zones as no alarm of home (stay-in) defense.
[01] - [99]
[99], enter defense zone type [1~4] and alarm type of defense zone [1~8]
[1~8], select 61
Operation:61 10
6110 0#
100 #
whether to enable/disable alarm [0/1] in defense alarm and finally press [#] to confirm;
voice prompts: set successfully, please enter instruction, Factory settings: immediate
defense zone [1], SOS alarm [1] and alarm enabling [1].
60
Settings:60 XX
60XX AB
XXA BC
C#
# 24. Artificial Recording
XX for defense zone number: [01]~[99] corresponds to defense 01 to 99. In Settings, first enter address code [70] , select artificial recording [1] and finally
A for defense zone type: [1]immediate defense zone,
[1]immediate 2defense
zone,2 defense delay 40 seconds, press [#] to confirm; [Recording] flashes, and the recording starts; 30
30cm to the host,
[3] 24h defense zone, 4
4bypass
bypass defense zone. with moderate tone, recording user information by standard mandarin; after 10
alarm,22Fire
B for alarm type: [1] SOS alarm, Fire alarm, 3Gas
alarm,3 Gas leak, 4
leak,4 seconds, beep sounds.
alarm,55 Hall
Magnetic contact alarm, Hall alarm, 6 window
alarm,6 window alarm
alarm, 70
Settings:70 1#
701 #
77balcony alarm,88perimeter
balcony alarm, perimeter alarm. 25. Recording Playback
C for alarm switch: [0] for OFF while [1] for ON. In Settings, first enter address code [70]
[70], select recording playback [2] and finally
Example: set 10 defense zones as 24h, fire alarm, and sound alarm press [#] to confirm; host speaker will immediately play last recording information;
60
Operation:60 1033221
10
6010 1#
# after 10 seconds, beep sounds.
Note: Wired defense zone type setting 70
Settings:70 2#
702 #
Wired defense zone Z1=81, Z2=82, and Z8=88 in turn. 26. Remote control
Example: set defense zone Z2 as gas leak and sound alarm in 24 hours In Settings, first enter address code [71]
[71], select whether to enable/disable [0/1] for
60
Operation:60 82
60 82 33
82 33
1
1
#
# remote control and press [#] to confirm; voice prompts: set successfully, please enter
23. Home Defense Zone instruction. Factory settings: [1]: enable remote control.
71
Settings:71 0/1##
0/1
710/1 Settings::74
74 X
74 X
#
#
1: enable remote control. 1 indicates: inform the alarm receiving center.
0: disable remote control. 0 indicates: dont inform the alarm receiving center
27. Call Ringing Times 30. Siren Prompt Setting
Call ringing signal is that when switchboard sends regular pulse signal, telephone In arm or disarm, external siren prompt arm or disarm
will check it to distinguish. [75] on the keypad, then enter[0/1],
In setup status, press[75] [0/1], finally press [#]
[#] Host make
In setup status, press [72]
[72], then input ring times [1~9]
[1~9], finally press [#] to confirmed. a long beep. A setting completed voice prompt appears. Factory settings: [0]:
Host make a long beep. A setting completed, please enter instruction voice prompt disable alarm prompt.
appears. Factory settings: [2]: Pickup after 2 times ringing Operating method75 75
75X X# #
Operating method72 72
72A A## 1: enable alarm prompt
X indicatesring times 0: disable alarm prompt
Example: host is controlled by remote after receiving 8 ringing signal Example: Detailed operating of sound on
7288##
72
Operation:72 75
Operation:75
751 1# #

31. Disconnection detection


28. Online Enabling In Settings, first enter address code [78]
[78], select [0/1] to check whether to enable or
This enables/disables online communication to identify whether to connect online disable disconnection alarm and press [#] to confirm; voice prompts: set successfully,
communication with alarm receipt center. please enter instruction.
In Settings, first enter address code [73] by console keypad, select Enable/Disable [0/1] If user alarm host is not connected with phone line, please set this function as [0] with
between the host and online computer alarm receipt and press [#] to confirm; voice no alarm detection due to line disconnection. Factory settings: [0]: no detection due to
prompts: set successfully, please enter command. Factory settings: [0]: disable online phone disconnection.
computer communication. 78
Operation:78 X#
78X #
73
Settings:73 X##
73X 1: enable disconnection detection and sound alarm.
1: enable online computer communication. 0: disable disconnection detection and sound no alarm.
0: disable online computer communication. 32. Out Arm Delayed Time Setting
29. Arm/Disarm Operating Notifications In setting status, press [79], then select the out arm delayed time [XX] seconds, finally
For security, alarm receiving center need to be informed or not when arm/ disarm press [#] to confirm. Voice prompt: setting completed, please enter instruction. factory
In Settings, first enter address code [74] by console keypad, select [0/1] to check default: [30] seconds: Out arm will be enter the arm status after delayed time 30
whether to report to computer alarm receipt with respect of defense/withdrawal and seconds.
press [#] to confirm; voice prompts: set successfully, please enter command. Factory 79
Operating:79 XX
79XX #
XX#
settings: [0]: do not inform the alarm receiving center. XX indicates: Out arm will be enter the arm status after delayed.
Example: set the delayed time is 10 seconds [Users Password
[User Password]]+ [#] (Keypad lock is on)
79
Operation:79 10##
10
7910
33. Information inquiry
In disarm status, directly enter [*], [0] and [#] in the information inquiry. And press [*]
Instructions]]
[Operating Instructions
and [#] to page up/down to review all alarm logs (at most 45 pieces of information), 1. Out arm
Password]] + [#] to exit information inquiry.
and finally press [Password Out arm means that full round detection monitoring shall be set on site when no
Keypad operation:**00## one is at home; all detectors are in working conditions; in case alarm source
LCD display: triggers the detector (thief of invading, fire, gas leak etc.), the alarm system sounds.
ARM
After the defense, [ARM
ARM] lights up.
Keypad operation: press
press ,, with console defense delayed for 30 seconds.
Remote operation: press remote control
control for
for defense.

Screen I: Screen II:

01: serial number of alarm log Alarm time: October 1, 2009 2. Home arm
12: Alarm defense zone, SOS alarm 8:35 pm Home arm refers to: it is necessary to enable the operations of door, window,
Arm display: balcony and perimeter detectors outside of alarm system for the sake of safety in
Arm status. case one is at home, without false alarm triggered by indoor detector; stay-in
defense is selected: some detectors work while others do not work. After the
defense, [Home] lights up.
Keypad operation: press
press with
with immediate defense during home arm.
Disarm display: Remote operation: press remote control
control ..
Disarm status. 3. Individual arm
Hosts random combination of 100 defense zones could be used for defense
through individual defense function. First press [#] to clear the keypad. Press
defense zone of [01~99] and press [ ]. The buzzer sounds beep, and
Alarm display: meanwhile defense zone light is on for one second indicating successful
individual defense. Repeat the said operations for the defense in other zones.
Keypad operation: 01
01 99 +
99
0199

Alarm status.
4. Disarm
Exit information inquiry: [Disarm ] (Keypad lock is off) or [Disarm ] Disarm refers to that the alarm is stopped; or the main host is enabled in
non-warning status. In detector triggering after disarming, the host will not alarm Press [1]:: Alarm system enters arm status and voice prompts System arm.
arm
(except for 24h defense and emergency alarm button). After disarm, [A
[ARRM] and Press [2]:: Alarm system enters disarm status and voice prompts System
[Home] go off. disarm
disarm.
Remote operation: press remote control
control .. Press [3]]: Alarm system enters monitoring status for 30 seconds and press [3]
Keypad operation: [Disarm ](Keypad lock is off) or [Disarm ]+ User
Users
]+User for 30 seconds delay repeatedly in case of continuous monitoring.
Password + ##(( Keypad lock is on)
Password 7. SOS
Some special cases occur in the family: sudden illness for the elderly or children
5. Telephone alarm receipt results in first aid; in case of sudden fire, help is needed; in case of housebreaking,
Host in defense status, once the alarm signal is received, will immediately enable the alarm is required; in emergency alarm, the time is not enough time or the
and sound the alarm; meanwhile all pre-set phone (mobile) numbers will be words are not ambiguous because of tension. Alarm button of host, static alarm
automatically dialed for alarm. The host will automatically dial up next phone key of remote control or emergency button alarm will be only pressed. Alarm
group in case of no answering of dialed phone number, and then all preset phone system will immediately sound loudly and automatically call the police.
numbers will be dialed in repeated form for three times respectively. If alarm control ..
Remote operation: press remote control
phone is answered, alarm information is heard from telephone receiver, such as Keypad operation: press console keypad button.
keypad button.
Alarm for the balcony in the 5th defense zone, and this is . And the keypad of
phone (mobile) is pressed to perform remote control of the console.
Care]]
[Maintenance and Care
Press [1]]: Stop alarm and arm, no longer dials up next phone number. 1. System detection
Press [2]]: Stop alarm and disarm, no longer dials up next phone number. The alarm system is used every day, needs regular care and maintenance and
Press [3]]: Sirens are closed and monitors 30 seconds on site, with delayed detection to ensure that the alarm system will be stable, reliable and safe.
then33is
monitoring and then is pressed continuously. Normally the alarm system needs a thorough inspection every 3 months and the
After alarm phone is answered, press only [3] to monitor and hang detectors need to be checked once a month, at least once every 3 months in case
up, other than [1] and [2]. of no conditions.
The host will no longer dial up such phone number, but will continuously dial up Console detection:
other preset alarm phone numbers. 1.1 Whether the alarm system can arm or disarm normally
6. Remote control 1.2 Whether the alarm system normally dials up the telephone numbers.
Dial-up the telephone (mobile) connected to main host, and after ringing times, 1.3 Whether the detector signal is received or backup battery works.
the telephone receiver prompts computer-generated voice: Please enter Sensor detection:
password. The password is entered via telephone (mobile). The console will in 1.1 Manually trigger the detector to check whether it sounds normal alarm.
case of wrong password give prompt: wrong password, please enter password 1.2 Check batteries of all detectors to make sure whether it is under-voltage.
again. In case of correct password, the telephone receiver prompts press 1 for 1.3 Check whether wireless detector is communicated with the host During
arm, press 2 for disarm and press 3 for monitoring. And after it is accessed, emission testing.
phone button could be used for remote control. 2. Notices
Alarm equipment, for explosion-proof design, shall not directly be used in
hazardous location with Grade I, II and III (flammable and explosive places),
otherwise it is very dangerous.
Do not dismantle, repair and modify products privately, or accidents and Technical Parameter
failures may be caused.
Adaptor power DC12V 500mA
Do not drop the product on the ground or hard objects to avoid strong
Static consumption 50mA
impact for failure and damage.
Alarm current MAX 450mA
Output current DC12V 150mA
Wireless frequency 315MHz/433MHz
3. Technical Parameter a Encoded mode 2262 IC / 4.7M
Table one: b
Siren volume 110dB
l
e Backup battery AAA 7.2V
Clock battery silver-zinc battery 3.0V
t Temperature -20 +55
w Humidity 40% 80%
o
: Engineering password system setup command table
Numb Setting item Add Date(XY) Remark Factory
er Default
1. Password Recover In arm/disarm status 0321456988
2. Factory Default In setting status 0321456987
Recover
3. Start Setting XXXX In setting status, XXXX=program 6666
password
4. Exit Setting *+ #
5 Coding of Remote 20 X X=1~8
Controller
6 Delete Remote 21 X X=1~8
Controller
7 Coding of Defense 23 X X=01~99
Zone
8 Delete Defense Zone 24 X XX= 01~99
9 Change User Password 30 XXXX XXXX= 4 digit user password 1234
10 Change Program 31 XXXX XXXX= 4 digit program 6666
Password password
11 User Code Setting 32 XXXX XXXX= 4 digit user code 8888
12 Year , Month, Day, 34 AABBCCD AA= the third and fourth digital
Hour, Minute DEE of year
BB=month, CC=day, DD= hour,
EE= minute ,( 24 hours)
13. Keypad Lock Setting 35 X X=1 on, need password 0
X=0 off, dont need password
14 Wireless Equipment 27 XXXXXXX XXXXXXXX=8 digit wireless
Coding Setting X equipment coding
15 Timed arm setting 37 XXYY XX=Hour, YY= minute
16 Timed disarm setting 38 XXYY XX=Hour, YY= minute
17 Timed Function Setting 39 X X=1 ON, X=O OFF 0
18. Alarm number setting 51~5 X X= Alarm number
6
19 Delete alarm number 51~56 X X=#
setting
20 Extension telephone 51~56 XY X=0 or 9, Y= alarm number
setting
21 Alarm receiving 57~58 X X= Alarm receiving number
number
22 Delete receiving 57~58 X X=#
number
23 Defense zone type 60 XXABC XX=[01~99] defense zone, A=
defense zone type. B=alarm type,
C= siren sound
24 Home arm setting 61 XXA XX=[01~99] defense zone, A=
siren sound
25 Artificial Recording 70 X X=1, recording
26 Recording playback 70 X X=0, playback
27 Remote control 71 X X=1 ON, X=0 OFF ON
28 Ring times 72 X X=Ring 1~9 times 2
29 Online enable 73 X X=1 ON, X=0 OFF OFF
30 Inform alarm center 74 X X=1 inform receiving centerX=0
dont inform receiving center
31 Siren prompt setting 75 X X=1 ON X=0 OFF
32 Disconnected line 78 X OFF
setting
33 Out home delayed 79 XX XX= delayed time about our 30
time setting home