Sei sulla pagina 1di 48

NIT SCHEDULE FOR CONSTRUCTION WORK OF BAGBAHARA TO CHANDI MAN

3.19 KM) IN DISTT MAHASAMUND, I/C. ELECTRIFICATION WORK, UNDER NAB


PAC - 703.82 Lacs
TENDER NO. - 11942
SERIAL No. Item Code

1 2.3

2 3.12

3 3.15

4 3.2
5 3.13

6 3.14

7 3.16

8 4.1

9 4.1 A(b)(ii)

10 4.1 B
11 4.10

12 5.1

13 5.2

14 5.4
15 5.5

16 9.4

17 6.6

18 6.7
19 4.13

20 8.14

21 8.14(iii)

22 8.4
8.4
23 C (b)(ii)
8.4
24 C (b)(iii)
25 8.5

26 8.6

27 4.17

28 9.1
29 9.9

30 1.4
31 1.4 (i)B

32 1.4 (iii)A
33 1.4 (iii)B

34 1.4 (ix)

35 2.1

36 2.3

37 2.6
38 3.6

39 3.6 A(a)(i)

40 3.7

41 4.1
42 4.1 A (I) a (ii)

43 4.1 B (I) a (i)

44 4.2

45 4.4
46 4.6

47 4.14

48 3.17

49 3.8

50 3.9

51 5.5

52 5.4
53 3.10

54 2.24

55 9.12

56 8.7
57 8.7 B

58 9.11

59 5.17
60 8.20

61 3.20

62 8.13

63 11.5
64 5.11

65 8.26

66 8.30

67 8.34

68 9.19

69 9.8
70 9.10

71 9.11

72 11.5

73 11.11

74 11.19

75 14.3

76 14.18

77 17.1
78 17.1.13
79 17.1.22

80 17.5

81 21.7

82 21.9

83 21.12

84 21.13
85 21.18

86 21.21

87 22.6

88 22.3

89 26.5
90 21.17
91 21.17.2

92 32.2
FOR CONSTRUCTION WORK OF BAGBAHARA TO CHANDI MANDIR ROAD( L.
STT MAHASAMUND, I/C. ELECTRIFICATION WORK, UNDER NABARD SCHEME.
PAC - 703.82 Lacs
TENDER NO. - 11942
Description UOM Quantity
Clearing and grubbing road land including uprooting rank
vegetation, grass, bushes, shrubs, saplings and trees
girth up to 300 mm, removal of stumps of trees cut
earlier and disposal of unserviceable materials and
stacking of serviceable material to be used or auctioned
up to a lead of 1000 meters including removal and
disposal of top organic soil not exceeding 150 mm in
thickness if required and as per relevant clauses of
section-200.
A. In area of light jungle

hectare 1.49
Construction of embankment with Material Obtained from
Borrow Pits/Borrow Area (Construction of embankment
with approved material/selected soil having C.B.R.>5
(unless specified otherwise in the contract) obtained from
borrow pits with all lifts and leads, transporting to site,
spreading, grading to required slope and compacting to
meet requirement of table 300-2)

cum 652.5
Compacting Original Ground
( ii ) Compacting Original Ground supporting
embankment Loosening, leveling and compacting original
ground to facilitate placement of first layer of
embankment, scarified to a depth of 150 mm, mixed with
water at O.M.C. and then compacted by rolling so as to
achieve minimum dry density as given in table 300-2 for
embankment construction.

cum 1494.45
Excavation in Soil (by Mechanical Means.)
Excavation for roadway in soil using mechanical means
including loading in tipper for carrying of cut earth to
embankment site and unloading with all lifts and lead
upto 1000 meters as per relevant clauses of section 300.

cum 2068.62
Construction of sub-grade with Material Obtained from
Borrow Pits/Borrow Area (Construction of sub-grade with
approved material/selected soil having C.B.R.>8 (unless
specified otherwise in the contract) obtained from borrow
pits with all lifts and leads, transporting to site,
spreading, grading to required slope and compacting to
meet requirement of table 300-2)

cum 30738.75
Construction of Embankment with Material Deposited
from Roadway Cutting (Construction of embankment with
approved materials having C.B.R.>5 (unless specified
otherwise in the contract) deposited at site from roadway
cutting and excavation from drain and foundation of
other structures graded and compacted to meet
requirement of table 300-2)

cum 1551.46
Surface Drains in Soil (Construction of unlined surface
drains of average cross sectional area 0.40 sqm in soil to
specified lines, grades, levels and dimensions to the
requirement of clause 301 and 309. Excavated material
to be used in embankment within a lead of 50 meters
(average lead 25 meters)

metre 100
Granular Sub-base as per Table:- 400-1
Construction of granular sub-base by providing graded
Material, , carriage of mixed Material to work site,
spreading in uniform layers with motor grader on
prepared surface watering, rolling and compacting with
vibratory power roller at OMC to achieve the desired
density, complete as per clause 401
A. Plant mix method (with Mechanically crushed stone
only)
(a) For Lower Sub-base with
(ii) Grading-IV Material

cum 4580.67
(b) For Sub-base cum drainage layer or upper sub-base
with (ii) Grading-VI Material
cum 4686.51
By Mix in place method
Disintegrated rock i.e moorum having CBR value not less
than 20 and P.I. and L.L. not more than 6 and 20
respectively.
(For Village roads only)

cum 275.59
Wet Mix Macadam (Providing, laying, spreading and
compacting graded stone aggregate to wet mix macadam
specification including premixing the Material with water
at OMC in mechanical mix plant carriage of mixed
Material by tipper to site, laying in uniform layers with
paver in sub- base / base course on well prepared surface
and compacting with vibratory roller to achieve the
desired density as per clause 406.)

cum 4656.42
Prime coat (Providing and applying primer coat with oil
based bitumen emulsion (SS-1, grade confirming to
IS:8887) on prepared surface of granular Base including
clearing of road surface and spraying primer using
mechanical means as per clause 502.
(i) on WBM/WMM surface @0.85 Kg/sqm.

sqm 17493
Tack coat Providing and applying tack coat with bitumen
emulsion (RS-1, grade confirming to IS:8887) using
emulsion pressure distributor on the prepared
bituminous/granular surface cleaned with mechanical
broom and as per clause 503.
(ii) Granular surfaces treated with primes @ 0.30 kg
/Sqm

sqm 17493
Dense Bituminous Macadam (Providing and laying dense
bituminous macadam with minimum 40-60 TPH capacity
HMP using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.0 to 4.5% by
weight of total mix of mix and filler, transporting the hot
mix to work site, laying with a hydrostatic paver finisher
to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve
the desired compaction as per MORTH specification
clause No.505 complete in all respects.)
B. With mechanical paver finisher
(ii) for Grading-II(26.5 mm nominal size bitumen content
4.50%)

cum 874.65
Bituminous Concrete (Providing and laying bituminous
concrete with minimum 40-60 TPH capacity hot mix plant
using crushed aggregates of specified grading, premixed
with bituminous binder @ 5.0 to 6.0% by weight of total
mix of mix and filler, transporting the hot mix to work
site, laying with a hydrostatic paver finisher with sensor
control to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to
achieve the desired compaction as per MORTH
specification clause No. 507 complete in all respects)
B. With mechanical paver finisher
(iii) for Grading II (13.2 mm nominal size) with bitumen
6.0 %

cum 524.79
Providing and laying Reinforced Cement Concrete pipe NP
3 / prestressed concrete pipe on first class bedding.
(Laying Reinforced cement concrete pipe NP3
/prestressed concrete pipe for culverts on first class
bedding of granular material including fixing collar with
cement mortar 1:2 but excluding excavation, protection
works, backfilling, concrete and masonry works in head
walls and parapets).
B. 600 mm dia

metre 75
Providing and laying cement concrete for plain concrete/
reinforced concrete i/c form work, shuttering complete in
as per drawings and specifications.( For Village roads)
(i) P.C.C. M-10
cum 462.9
Providing and laying un-reinforced Cement Concrete
without Dowel bars including formworks and expansion
contraction & longitudinal joints as per design and as per
IRC-62-2014, over a prepared base a per approved mix
design and finishing to lines and grade as per Drawing for
Pavement thickness less than 200mm in Low Volume
Roads.
PCC Grade M30 with minimum Cement Content
@375kg/cum

cum 1134
Construction of Shoulders (Construction of shoulders as
per clause 408 with selected soil from borrow pits /
borrow areas having CBR not less than 12 and shall have
L.L. and P.I. not more than 25% and 6% respectively,
inclusive of all leads and lifts, including clearing and
scrapping of existing surface, providing required cross
fall, compacting. watering rolling and royalty charges etc.
complete.
B. With smooth wheeled roller

cum 1567.65
Kilo Meter Stone (Reinforced cement concrete M15grade
kilometer stone of standard design as per IRC:8-1980,
fixing in position including painting and printing etc)
(ii) Ordinary Kilometer stone (Precast)
each 6
(iii) Hectometer stone (Precast)

each 14
Retro- reflectrorized Traffic signs (Providing and fixing of
retro- reflectrorized cautionary, mandatory and
informatory sign as per IRC:67-2012 made of retro-
reflective type sheeting vide clause 801.3, fixed over
aluminum sheeting of required thickness supported on a
mild steel back frame of ISA 40 x 40 x 5 mm and mild
steel angle iron post 75 mm x75 mm x 6mm firmly fixed
to the ground by means of properly designed foundation
with M15 grade cement concrete 45 cm x 45cm x 60cm,
60 cm below ground level as per approved drawing and
painting all components of the signs and supports as per
clause 7.2of IRC:67-2012)
C. Made of Class-A High Intensity Super Engineering
Grade Sheeting of Type II ( for-ODR & Village Roads)
b.) With Aluminum Sheeting of 1.5 mm thikness
(i) 600 mm equilateral triangle

each 4
(ii) 600 mm circular
each 4
(iii) 600 mm x 500 rectangular
each 4
Direction and Place Identification signs upto 0.9 sqm size
board. (Providing and erecting direction and place
identification retro-reflectorized sign as per IRC:67-2012
made of retro-reflective type sheeting and vide clause
801.3, fixed over aluminum sheeting, 2 mm thick with
area not exceeding 0.9 sqm and fixed on a mild steel,
back frame of ISA 40x40x5 mm, supported on a mild
steel angle iron post of size 75 x 75 x 6 mm, firmly fixed
to the ground with M15 grade cement concrete 45 x 45 x
60cm, 60cm below ground level as per approved
drawing)
C. Made of Class-A High Intensity Micro Prismate Grade
Sheeting of Type-I( For ODR & Village Roads)

sqm 4
Direction and Place Identification signs with size more
than 0.9 sqm size board. (Providing and erecting direction
and place identification retro- reflectorized sign as per
IRC:67-2012 made of retro-reflective type sheeting vide
clause 801.3, fixed over aluminum sheeting, 2 mm thick
with area exceeding 0.9 sqm and fixed on a mild steel
frame of size 40x40x 5 mm, suppoted on 2 Nos. mild
steel angle iron posts of size 75mm x 75mm x 6mm,
firmly fixed to the ground with M15 grade cement
concrete 45cm x 45cm x 60cm, 60cm below ground level
as per approved drawing)
C. Made of Class-A High Intensity Micro Prismate Grade
Sheeting of Type-I( For ODR & Village Roads)

sqm 4.32
Providing and fixing guard stones 200 x 200 x 900 mm
made of precast RCC M-20 grade fixed at 300 mm into
the ground in P.C.C. 1:3:6 blocks of size 400 x 400 x 400
mm and given two coats of paint with white and black
bands including excavation.
each 150
Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical
specification, including setting out, construction of
shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and
backfilling with approved material.)
Ordinary soil
Up to 3 m depth

cum 282.74
Plain cement concrete complete as per drawing and
Technical Specifications
PCC Grade M 15
cum 236.12
Dismantling of existing structures like culverts, bridges,
retaining walls and other structure comprising of
masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary,
sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all
lifts and lead upto 1000 meters and as per relevant
clauses of section-200 in
(i) Lime / Cement Concrete
A. Lime Concrete, cement concrete grade M-10 and below

cum 27.76
B Cement Concrete Grade M-15 & M-20 cum 329.07
Stone Masonry
Rubble stone masonry in lime mortar cum 32
Rubble stone masonry in cement mortar. cum 18.6
Removing all type of hume pipes and stacking within a
lead upto 1000 meters including earthwork and
dismantling of masonry works around pipes.
Up to 1000 mm dia
metre 110
Excavation for Structures Earth work in excavation of
foundation of structures as per drawing and technical
specification, including setting out, construction of
shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and
backfilling with approved material including dewatering
etc. complete.
I. Ordinary soil
(i) Upto 3 m depth

cum 1514.88
Sand Filling in Foundation Trenches as per Drawing &
Technical Specifications. cum 149.68
Plain/Reinforced cement concrete in open foundation
complete as per drawing and technical specifications.
A. Using concrete mixer
(i) PCC Grade M15
cum 614.48
Providing and laying Plain/Reinforced cement concrete in
sub-structure complete as per drawing and technical
specifications section 1500, 1700 and 2200 (Newly laid
concrete shall be covered by gunny bags).
D. Height upto 5m
(a) Using concrete Mixer
(i) R.C.C. Grade M-20

cum 58.168
Height upto 5m
Using concrete Mixer
P.C.C. Grade M-15
cum 563.23
Supplying, fitting and placing HSD (High Strength
Deformed Steel) bars reinforcement in sub-structure
complete as per drawing and technical specifications
section 1600 and 2200.
MT 5.499
Furnishing and Placing Reinforced/Prestressed cement
concrete in super-structure as per drawing and Technical
Specification sections 1500, 1600 and 1700 (Newly laid
concrete shall be covered by gunny bags).
A. RCC Grade M25
I. For Solid Slab Super Structure
(a) Using Concrete Mixer
(i) Height upto 5m

cum 40.6
Height 5m to 10m cum 22.7
RCC Grade M 30
For Solid Slab Super Structure
Using Concrete Mixer
Height upto 5m
cum 41.37
Supplying, fitting and placing HSD (High Strength
Deformed Steel) bar reinforcement in super-structure
complete as per drawing and technical specifications
MT 13.251
Providing and laying Cement concrete wearing coat M-30
grade including reinforcement complete as per drawing
and Technical Specifications as per relevant clause of
section 2700.
cum 9.62
Construction of RCC railing of M30 Grade in-situ with 20
mm nominal size aggregate, true to line and grade,
tolerance of vertical RCC post not to exceed 1 in 500,
centre to centre spacing between vertical post not to
exceed 2000 mm, leaving adequate space between
vertical post for expansion, complete as per approved
drawings and technical specifications. (vide drawing No.
SD/201, SD/304)

metre 13.6
Filler joint
B .Providing & fixing 20 mm thick compressible fiber
board (12 m long x 25 cm deep ) in expansion joint
complete as per drawing & Technical Specification.
sqm 51.86
Providing and fixing in position tar paper bearing for slab
as per approved drawings and specification.
sqm 65.4
Providing weep holes in Brick masonry/ Plain/ Reinforced
concrete abutment, wing wall/return wall with 100 mm
dia. AC pipe, extending through the full width of the
structure with slope of 1 V: 20 H towards drawing face.
Complete as per drawing and Technical specifications
section 2706 and 2200.

metre 539.1
Back filling behind abutment, wing wall and return wall
complete as per drawing and Technical specification
710.1.4 of I.R.C. 78 and 2200.
(i) Granular material

cum 249.34
Providing and laying Filter material underneath pitching
in slopes complete as per drawing and Technical
specification including trimming of slopes to proper
profile and preparation of bed as per section 2504.
cum 18.58
Providing and laying Pitching on slopes laid over prepared
filter media including boulder apron laid dry in front of
toe of embankment complete as per drawing and
Technical specifications as per section 2504.
A. Stone/Boulder

cum 31.17
Providing and laying of Filter media with granular
materials/stone crushed aggregates satisfying the
requirements laid down in clause 2504.2.2. of MORT&H
specifications to a thickness of not less than 600 mm with
smaller size towards the soil and bigger size towards the
wall and provided over the entire surface behind
abutment, wing wall and return wall to the full height
compacted to a firm condition complete as per drawing
and technical specifications 710.1.4 of I.R.C. 78 and
2200.

cum 158.56
Supplying, fitting and placing HSD (High Strength
Deformed Steel) bar reinforcement in foundation
complete as per drawing and technical specifications as
per section 1600.
MT 1.01
Providing and laying Filter material underneath pitching
in slopes complete as per drawing and Technical
specification including trimming of slopes to proper
profile and preparation of bed and as per clause 2504.
cum 73.13
Overhead Signs (Providing and erecting overhead signs
with a corrosion resistant aluminum alloy sheet
reflectorized with high intensity retro-reflective sheeting
of Class-C Micro prismatic grade Sheeting of type IX with
vertical and lateral clearance given in clause 802.2 and
802.3 and installed as per clause 802.6 over a designed
support system of aluminum alloy or galvanized steel
trestles and trusses of sections and type as per structural
design requirements and approved plans)
A. Truss and Vertical Support

Tonne 2.535
B. Aluminum alloy plate for over head sign sqm 68.4
Providing and laying Pitching Stone/Boulder on slopes laid
over prepared filter media including boulder apron laid
dry in front of toe of embankment complete as per
drawing and Technical specifications as per clause 2504.
cum 109.69
Grouting with C.M. 1:4 in Pitching as per drawing and
technical specification. cum 109.69
Providing & Fixing Hazard Marker Type-2 Partial Retro
Reflective Size 0.30 x 0.90M made of 16 gauge (1.6 mm)
thick mild steel sheet Confirming to IS:2062 Painted with
one cast of Zinc Chromate Stoving Primer and two coats
of Black Stove Enamel (Oven Baked) paint with 10 cm
bands of yellow Retro- Reflective Sheeting of Engineering
Grade pasted a per IRC:79 including one MS angle Iron
post of size 50x50x5 mm of 1.65 meter long duly painted
with synthetic enameled paint block including bolts and
fixing the same in M-15 concrete black of size
30x30x30cm, including transportation etc. Complete.

each 8
Construction of RCC open drain
(ii) Construction of RCC open drain 0.60m x 0.60m inside
dimension lined with 120 mm thick RCC M-20 walls, 120
mm thick CC M-20 foundation, over 100 mm thick (Av)
leveling course in PCC M-15 including excavation ,
dressing of sides and bottom, provision of HYSD
reinforcement consisting 8 mm dia horizontal bars @ 150
mm c/c and L-shaped 8 mm dia vertical bars @ 150 mm
c/c (L= 800 mm) including cutting , bending and binding
wire, placing in position , providing shuttering and
concreting by using concrete mixer, compaction by
vibration etc complete as per drawings and technical
specifications.

metre 2280
Road Marking with Hot Applied Thermoplastic Compound
with Reflectorizing Glass Beads on Bituminous Surface
(Providing and laying of hot applied thermoplastic
compound 2.5 mm thick including reflectorizing glass
beads @ 250 gms per sqm area, thickness of 2.5 mm is
exclusive of surface applied glass beads as per IRC:35-
1997. The finished surface to be level, uniform and free
from streaks and holes.)

sqm 935.55
Half Brick Circular Tree Guard, in 2nd class Brick,
internal diameter 1.25 meters, and height 1.2 meters,
above ground and 0.20 meter below ground (Half brick
circular tree guard, in 2nd class brick, internal diameter
1.25 meters, and height 1.2 meters, above ground and
0.20 meter below ground, bottom two courses laid dry,
and top three courses in cement mortar 1:6 (1 cement : 6
sand) and the intermediate courses being in dry honey
comb masonry, as per design complete)

each 200
Supplying and drawing following sizes of FR PVC
insulated copper conductor, single core cable in the
existing surface/ concealed, steel/ PVC conduit/ PVC
casing caping as required.
5.11.12) 3 x 2.5 sq. mm
metre 900
Supplying, installation, testing and commissioning of
following 230/250 volts metal halide wide beam flood
light luminaries with weather proof gear box, igniter,
capacitor with IP 66 protection on wall surface/ building
parapet/ pole bracket complete but without lamp as
required.
8.26.3)1x250 watt

each 24
Supplying, installation, testing and commissioning of
following 230/250 volts LED street light fitting with all
accessories like driver, heat sink made of die cast
aluminium with IP 66 protection and 5 KV surge
protection on pole bracket complete as required and
furnishing 2 Yrs Guarantee certificate from manufacturer.
8.3.2)40-45 watt

each 44
Supplying, fixing, testing and commissioning of following
230/250 volts metal halide lamp in existing lighting
luminaries fixed on pole/ wall/ roof etc as required.
8.34.7) 250 Watt (E)
each 24
Fabrication, supply, installation, testing and
commissioning of cubicle type compartmentalized wall/
floor mounted power cum control panel board of specified
size and following depth made out of not less than 2 mm
thick CRCA MS sheet with suitable size compartments for
bus bars, switchgears and necessary cutouts for
voltmeters, ammeters etc as per specifications including
powder coating painting but without busbars, switchgears
and other accessories etc complete as required.
(Only face area is to be measured)
9.19.1)Upto 300 mm deep

sqm 1.5
Supplying and fixing metal clad busbar chamber made of
1.6 mm thick CRCA sheet with 4 strip copper busbars of
following capacity and length, complete with all
accessories, including earthing the body etc. as required.
9.8.5) 200 amps x 450mm long

each 1
Providing and fixing metal clad, TP&N switch fuse unit (re-
wirable), 415/500 volts, with porcelain re-wireble fuses
including drilling holes on the board, connections,
earthing the body etc. as required. (Thimbeling shall be
paid separately).
9.10.4)200 amps
each 1
Providing and fixing porcelain re-wireble fuse carrier and
base unit on wooden board including drilling holes on the
board, screws, connections etc. as required. (Thimbeling
shall be paid separately).
9.11.5) 200 amps

each 3
Supplying and fixing on surface/ recess vertical type
following way, 415 volts, TPN MCB distribution board of
sheet steel phosphatized and powder painted, with 200
amps tinned copper busbar, common neutral link, earth
bar, din bar, detachable gland/ knock out plate, including
interconnections, earthing etc. as required. (But without
MCB/RCCB/Isolator) (Note : Vertical type MCB TPDB is
normally used where 3 phase outlets are required.)
11.5.4) 4 way (4 + 12), Double door

each 1
Supplying and fixing SP MCB, 240 volts, 'C' curve,
suitable for inductive load in the existing MCB DB
complete with connections, testing and commissioning
etc. as required.
11.11.2)6 amps to 32 amps
each 68
Supplying and fixing following rating, 415 volts, FOUR
POLES, ISOLATOR in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
11.19.2) 63 amps
each 1
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm
thick including accessories, and providing masonry
enclosure with cover plate having locking arrangement
and watering pipe, with charcoal and salt as required.
Set 6
Providing and fixing 6 SWG dia G.I. wire on surface or in
recess for loop earthing as required. metre 75
Supplying and laying following sizes one number PVC
insulated/ XLPE, PVC sheathed, steel armoured,
aluminium conductor power cable of 1.1 KV grade direct
in ground including excavation, sand cushioning,
protective covering and refilling the trench etc as
required.
17.1.12) 3.5 x 35 sq. mm.
metre 250
3.5 x 50 sq. mm. metre 85
4 x 10 sq. mm. metre 1100
Supplying and laying following sizes one number PVC
insulated/ XLPE, PVC sheathed, steel armoured,
aluminium conductor power cable of 1.1 KV grade on
surface/ existing cable tray with 1 mm thick GI saddle as
required.
17.5.14)4 x 16 sq. mm.
metre 500
Supply of hot dipped galvanized (in single dip to average
65 micron) octoganal pole made of 3mm thick steel sheet
having window and flush cover with locking arrangement
at suitable height from base for cable termination block,
pole suitably reinforced with welded steel section at
window cut section to make the strength of pole
unaffected, with following minimum specifications
including 3mm thick anchor plate, 4 nos 20mm dia
foundation bolts of EN8 grade. (designed for wind speed
upto 150km/hr)
21.7.2) 7 metre high, dia 130mm at bottom and 70mm at
top, base plate size 220x220x12mm, foundation bolts
700mm long

each 44
Supply and fixing following street light pole bracket on
existing pole made out of 50 mm dia MS "B" class pipe
welded to 300 mm long MS pole canopy of suitable dia at
a angle of 102.50 including having MS triangular stiffner
of size 150 X 50 X 5 mm thick, making arrangement for
tightening the bracket with pole by providing suitable
size heavy duty nuts and bolts in canopy, painting with
one coat of approved steel primer etc. as required.
21.9.2) Single Over Hang 1.00 metre Long

each 44
Designing and providing suitable RCC foundation in
Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4
graded stone aggregate 20 mm nominal size) for 3 mere
to 12 metre high GI octagonal pole including steel
reinforcement (minimum 90kg per cum), form work,
embeding 2 nos 50mm dia PVC pipe for cable entry in
each foundation, excavation disposal of surplus soil and
curing etc. as required.

cum 66
Providing and making suitable CC pole collar (muffing) in
Cement Concrete 1:3:6 (1 cement: 3 coarse sand: 6
graded stone aggregate 20 mm nominal size) of size 0.4
m dia and 0.4 m height from existing CC foundation.
each 44
Supplying erection testing and commissioning of hot dipped galvanised (single
dip 86 micron) 16 metre High mast pole on existing RCC foundation with all
accessories and equipments, detailed as below to withstand wind pressure upto
180km/hr and minimum following specifications:
a) HM shaft made of not more than 2 sections of suitable lengths with
telescopic stressfit joints between sections without any circumpherencial
welding, sheet thickness 4mm top and bottom sections, nominal dia 460mm on
bottom and 150 mm on top, base flange 25mm thick 670mm dia, PCD of
foundation bolts 650mm.
b) Double drum winch for lowering & raising of lantern carriage on high mast
with operatable with power tool/ manual handle attachment with a torque
limiting device for safe locking of carriage.
c) Raising/lowering type lantern carriage designed to carry specified nos of
luminaries, control gear box, junction box.
d) Top pulley assemble with weather proof cover.
e) 3 Nos suitable length and size stainless steel wire ropes (minimum 6mm dia
and 7/19 construction) for lowering & raising of lantern carriage.
f) Suitable size and length multicore flexible copper power trailing cable
(minimum 3 core 4 sqmm)
g) Hinged service door in base section
h) Base plate earthing terminal.
i) Suitable arrangement for supply distribution with termination of suitable size
underground cable in high mast.
j) Lightning conductor finial made of 25mm dia 300 mm long G.I. tube having
single prong.
k) Anchor plate of size 840x840x6mm, tem-plates 3mm thick, GI foundation
bolts 8 Nos of 30 mm dia 850 mm long (EN 8 Grade) along with nuts washers
etc.
(RCC fooundation and luminaries will be paid separately)

each 2
Designing and providing suitable and approved size RCC
foundation for 15-30 mere high mast including seel
reinforcement (minimum 90kg per cum), form work,
embeding 2 nos 50mm dia PVC pipe for cable entry in
each foundation, excavation disposal of surplus soil and
curing etc. as required including laying and fixing HM
foundation bolts with tam plates but excluding the cost of
foundation bolts with tam plates etc complete as
required.

cum 21.51
Supplying of angle/channel iron cross arms/ bracket/
other fitting of approved size and shape including drilling
of holes for insulator pins, bolts and nuts etc as required.

kg 40
Supplying and erection of G.I wire of size 8 SWG to 4 SWG
including binding etc. as required. kg 40
Supplying and fixing of following sizes 'B' class G I pipe
with all necessary Tee's, bends, sockets in the suction/
delivery line including cutting and threading etc. as
required.
26.5.6) 32 mm dia.
metre 66
Supplying and fixing PVC water tight terminal box of
approved make and brand with detachable gland plate in
bottom, hinged front openable cover, rubber gasket,
having 1 Nos 4way connector and 1 No SPMCB inside the
box for cable connection, fixed to pole with 2 Nos clamp
made from 25x3mm GI flat with 2 No GI nuts bolts
complete as required.
21.17.1) 250x200x125 mm for single phase

each 38
300x200x125 mm for 3 phase each 6
Earth work in soft rock with all lead and 1.5 metre lift,
dressing, stacking excavated strata including refilling
with excavated soil in trench / pit to ground level
complete as required
cum 25.2
40680 60613.2

223 145507.5

28 41844.6

95 196518.9
250 7684688

80 124116.8

44 4400

1458 6678617

1363 6387713

0
1434 6677306

64 1119552

17 297381

7916 6923729
9812 5149239

2617 196275

2789 1291028

4549 5158566
277 434239.1

1460 8760

410 5740

0
0

0
0

0
0

0
0

0
0

0
0

0
0

0
0

0
0

0
0

0
0

0
0

0
0
0

0
0

0
0
0

Potrebbero piacerti anche