Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
TabLE of Contents
Waterproof Enclosure S70-003 to S70-065 . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Waterproof Enclosure S70-130/131* and S70-180/181* . . . . . . . . . . . . . . . . . . . . . .3
Waterproof / Explosion Proof Enclosure S70-708 TO S70-720 . . . . . . . . . . . . . . . . . . . .4
CONTROLS Series 70 Electric Actuator
R
Dimensions
wATERPROOF Enclosure
S70-003 to S70-065
D 1.25 A
[32]
P
J E
K
Typically .78 H NPT Conduit Entry 2 Places Detail A1 - Output Bore Typically
[20] or M20 for models 003 & 005 (Series 70-030, 4 Places
or M25 for models 008 065 050, 065 Only) N x Q Deep
Holes For 3.00 .47
#10-24 UNC [76] [12] 1.97 x 2.6 Deep
or M5 G C [50 x 66]
4 Places
R
Notes:
The duty cycle for intermittent on-off operation is 25%. The continuous duty actuator with Servo is rated for 100% modulating operation.
2) Handwheel Spinner shown in drawing is available as an option.
3) K & M Dimensions are also available in M8, M12, and M20.
4) N Dimension is also available with Double Square (Star) drive.
Drawings are for reference only. Please refer to Bray ES drawings on the Bray website,
www.bray.com. Bray reserves the right to change product dimensions without notice. SR Drawing #70-003/065-im - August 2012- Rev. 0
Inquire/P.O. No.:_____________________________________ Customer/Project:_____________________________________
Pg. 2
Bray Order No.: _____________________________________
CONTROLS Series 70 Electric Actuator
R
Dimensions
wATERPROOF Enclosure
S70-130/131* and S70-180/181*
F
Holes For Spinner Not shown
#10-24 UNC B see note 2
[M5]
S T
Allow 2.5 for
Cover Removal
1.25 [32]
D A U
J 5.4 E
Max Stem
Entry K
Typically
4 Places
Typically .78
M
H NPT Conduit Entry 2 Places Detail A2 - Output Bore Typically
[20]
or M25 S70-131/181 S70-130/180 4 Places
3.00 G
[76] .47 .62
[12] [15.8]
C
R 2.38 3.05
[60] [77.9]
1.97 2.50
[50] [62.7]
Notes:
The duty cycle for intermittent on-off operation is 25%. The continuous duty actuator with Servo is rated for 100% modulating operation.
2) Handwheel Spinner shown in drawing is available as an option.
3) K & M Dimensions are also available in M8, M12, and M20.
4) N Dimension is also available with Double Square (Star) drive.
Drawings are for reference only. Please refer to Bray ES drawings on the Bray website,
www.bray.com. Bray reserves the right to change product dimensions without notice. SR Drawing #70-130/131-180/181 im
August 2012- Rev. 0
Inquire/P.O. No.:_____________________________________
Pg. 3 Customer/Project:_____________________________________
Bray Order No.: _____________________________________
CONTROLS Series 70 Electric Actuator
R
Dimensions
F Spinner Not
Allow 3.12 [80] Shown See
For Cover Removal B .58 For Override Note 2
[14] Engagement
M
3.00 See Note 2 Typically
[76] 4 Places
D OPEN
A
R CLOSE
J P
E
Typically .78 K
[20] Typically
4 Places
H NPT Conduit Entry 2 Places
or M25
N x Q Deep
G C
Notes:
The duty cycle for intermittent on-off operation is 25%. The continuous duty actuator with Servo is rated for 100% modulating operation.
2) Handwheel Spinner shown in drawing is available as an option.
3) K & M dimensions are also available in M8, M12, and M20.
4) N dimension is also available with Double Square (Star) drive.
Drawings are for reference only. Please refer to Bray ES drawings on the Bray website,
www.bray.com. Bray reserves the right to change product dimensions without notice. SR Drawing #70-708/720-im - August 2012- Rev. 0
Inquire/P.O. No.:_____________________________________ Customer/Project:_____________________________________
Pg. 4
Bray Order No.: _____________________________________