DRYLOK Clear Masonry Waterproofer

UNITED GILSONITE LABORATORIES


MAILING: P.O. Box 70, Scranton, Pennsylvania, 18501
SHIPPING: 1396 Jeerson Avenue, Dunmore, Pennsylvania, 18509
TOLL FREE: 1-800-UGL-LABS (845-5227)
PHONE: 1-570-344-1202 FAX: 1-570-969-7634

www.ugl.com

High gloss
DRYLOK Clear Masonry Waterproofer is the % WEIGHT SOLIDS:
first non-pigmented masonry waterproofer 31% 2% SHELF LIFE:
specifically formulated for use on bare % VOLUME SOLIDS: Unopened, 3 years
masonry floor and wall surfaces. This Patent
31% 2% FREEZE/THAW:
Pending Technology provides a durable,
waterproof, easy to clean, non-yellowing DENSITY (LBS./US GAL.): Protect from freezing (passes 3 cycles)
high gloss finish. DRYLOK Clear Masonry 8.50 0.5 lbs. CONTAINER SIZES:
Waterproofer incorporates ISP CleanGuard, VISCOSITY: One gallon (US) and five gallon (US)
environmentally safe green biocides, to resist 120-125 containers
the growth of mildew on the dry paint film.
pH:
DRYLOK Clear Masonry Waterproofer has
been tested in accordance to requirements 8.5-9.0 Does not exceed 100 g/L
of ASTM D-7088 Resistance to Hydrostatic COLORS:
Pressure at 4 P.S.I. and ASTM D-6904 Clear
Resistance to Wind Driven Rain of 98 mph. N/A
DRY TIME:
Clear high-gloss waterproof coating To touch: 2 hours
Exterior-wall water repellent To recoat walls: 4 hours Do not thin.
Stops hydrostatic pressure Light foot trac: 4 hours
Resists wind driven rain Heavy foot trac: 24 hours
Best results are obtained when applied over
High abrasion resistance Under floor covering: 24 hours
dry surfaces. Wait for a dry (rain-free)
Provides moisture/vapor barrier to floors Note: Maximum cure and dry time will
period for application. Surface must be clean
prior to appling a adhesive and flooring be prolonged when slightly humid
and free from dirt, dust, grease, oil, form
Use as a top coat or use under latex paint and/or damp, cool conditions prevail.
release compound, clear sealers or paint.
Contractor approved CLEAN UP: Patch all holes and cracks, especially the
Complies with current VOC requirements Soap and water. floor/wall joint with DRYLOK FAST PLUG, a
Reduces radon gas penetration Dispose of contaminated absorbent, fast setting hydraulic cement or use a
container and unused contents in patching compound which matches the
accordance with local, state and federal original surface color and smooth the patch
Its perfect for waterproofing interior and evenly with the surface around it.
regulations.
exterior concrete floors, poured concrete
walls, split-faced block, concrete and cinder COVERAGE (SQ. FT./US GAL.): EFFLORESCENCE, a white, powdery,
block, stone, brick, stucco and pre-cast 90-100 sq. ft./gal. crystal-like deposit visible on the masonry
decorative items. surface must be removed.
Note: Actual coverage will vary
depending upon application method, DRYLOK ETCH or muriatic acid, used
surface texture and porosity. according to manufacturers directions, are
Not recommended for automobile trac. eective eorescence removal agents. All
RECOMMENDED FILM THICKNESS/COAT:
masonry surfaces are subject to occurrences
16 wet mils/coat of eorescence.
COMPOSITION: FLASH POINT:
Latex Re-apply acid until all visible eorescence is
N/A
SHEEN: gone. Rinse thoroughly and allow to dry

DRY TIME: CLEAN-UP: COVERAGE: SPREAD RATE:


Soap
2 Hours Soap and Water 2 Coats Minimum 90-100 Sq.
Recoat 4 Hours Ft./Gallon

OVER
thoroughly. nylon bristle brush or sprayer. If rolled or to solvents with permanent brain and
Floor Prepartion: Highly troweled or sprayed, backbrush if necessary, to fill any nervous system damage. Intentional misuse
extremely smooth concrete floors must be pinholes in the masonry. If brushed, work the by deliberately concentrating and inhaling
acid etched or mechanically abraded to waterproofer into the pores of the masonry, the contents may be harmful or fatal. Do not
achieve the proper profile. Treat with making sure to fill all pores and pinholes (see breathe vapors or spray mist. Ensure fresh air
DRYLOK Etch (liquid or powdered) or IMPORTANT). If sprayed, refer to spray entry during application and drying. If you
muriatic acid, according to manufacturers specification sheet D99 at www.ugl.com. experience eye watering, headache or
directions. A properly prepared concrete APPLY TWO COATS. The second coat may dizziness or if air monitoring demonstrates
floor should look and feel like medium grit be applied by roller, brush or spray. Do not vapor/mist levels are above applicable limits,
sandpaper. Repeat etching procedure until over apply. wear an appropriate, properly fitted
the proper texture is achieved. Floor Application: The second coat should respirator (NIOSH approved) during and
Test the concretes porosity and check for be applied in a cross direction to the first after application. Follow respirator
residual sealers by sprinkling a few drops of coat to achieve uniformity. Apply 2 coats. manufacturers directions for respirator use.
water on surface. If the water does not Can be subjected to light foot trac within 4 Close container after each use. Do not get in
readily penetrate into the prepared hours and heavy foot trac within 24 hours. eyes, on skin or clothing. Wash thoroughly
concrete, additional acid etching is required. Not recommended for surfaces subject to after handling.
All residual acid etching material must be vehicular trac. If covering with flooring or KEEP OUT OF REACH OF CHILDREN.
removed from the surface, rinse thoroughly carpeting, allow final coat of DRYLOK Clear DO NOT TAKE INTERNALLY.
and allow to dry. Waterproofer to dry 24 hours. Use water KEEP FROM FREEZING.
based adhesives only for flooring
To verify the surface is thoroughly dry and installations. If top-coating use a water base
free of residual trapped moisture, tape a 1 ft. paint or coating. Any screws, nails or anchors EYES: Flush immediately with large amounts
by 1 ft. square piece of plastic onto the that penetrate the coating will nullify the of water for at least 15 minutes. Consult a
surface and let stand for 24 hours. If moisture waterproofing properties. physician if irritation persists.
is present on the concrete side of the plastic SKIN: Wash aected areas with soap and
the surface has not dried suciently. Allow Lift and place items on floor surfaces to
avoid marring. water. Consult a physician if irritation
additional drying and retest. persists.
NOTE: Waterproofed surfaces may become INGESTION: Give 1 or 2 glasses of water. If
slippery when wet. If desired, add 2-4 oz. of individual is drowsy or unconscious do not
If you scrape, sand, or remove old paint, you
DRYLOK Non-Skid Additive to each gallon give anything by mouth. Consult a physician,
may release lead dust. LEAD IS TOXIC.
for slip resistance. medical facility or poison control center for
EXPOSURE TO LEAD DUST CAN CAUSE
SERIOUS ILLNESS, SUCH AS BRAIN advise about whether to induce vomiting.
DAMAGE, ESPECIALLY IN CHILDREN. INHALATION: Remove to fresh air.
If leaking is still present after two coats, it
PREGNANT WOMEN SHOULD ALSO indicates that pores or pin holes are still For additional health and safety information
AVOID EXPOSURE. Wear a NIOSH- open. After applying the second coat of please refer to the Materials Safety Data
approved respirator to control lead DRYLOK Clear Masonry Waterproofer, Sheet.
exposure. Clean up carefully with a HEPA carefully inspect the entire wall surface for
vacuum and a wet mop. Before you start, any pinholes in the waterproof coating. Any
find out how to protect yourself and your aected area should be painted with an N/A
family by contacting the National Lead additional coat to ensure satisfactory For additional health and safety information
Information Hotline at 1-800-424-LEAD or waterproofing results. please refer to the Materials Safety Data
log on to www.epa.gov/lead.
Sheet.
Use only with adequate ventilation.
STIR THOROUGHLY BEFORE Vapor harmful. May aect the brain or DRYLOK Clear Masonry Waterproofer has
APPLICATION. DO NOT THIN. Appears nervous system causing dizziness, headache been tested in accordance to requirements
milky in the can but dries clear. Pre-test to or nausea. Causes eye, nose and throat of ASTM D-7088 Resistance to Hydrostatic
determine final appearance. Air and surface irritation. May be harmful if absorbed Pressure at 4 P.S.I. and ASTM D-6904
temperatures must be 50F, or higher. through skin. Harmful if swallowed. Resistance to Wind Driven Rain of 98 mph.
Apply directly on bare masonry. Apply
first coat with a roller (3/8" nap) or foam NOTICE: Reports have associated repeated
roller, a DRYLOK Brush or a good quality and prolonged occupational overexposure

DISCLAIMER:This information is furnished without warranty,


representation, inducement or license of any kind, except that it
is accurate to the best of UGLs knowledge, or obtained from
sources believed by UGL to be accurate, and UGL does not
assume any legal responsibility for use or reliance upon same.
Before using any product, read the label.
Clear Masonry Waterproofer
1 GAL. 2/Case . . . . . . . . . . . . . . . .20913
5 GAL. 1/Case . . . . . . . . . . . . . . .20915

LR314