Creating FCOA Configurations

C.1.3 Antenna sharing (co-siting)

The Dual Duplexer Module (ERxA) can be configured to share the Rx


diversity signal between Flexi EDGE BTS and an external BTS (or other
receiver).

For details, see Dual Duplexer Module (ERxA) Description.

C.1.4 Internal switching to 4-way uplink diversity (4UD)

Flexi EDGE BTS uses an internal switch to designate configurations as 2-


way uplink diversity (2UD) or 4-way uplink diversity (4UD). The switch is
based on the Site Configuration File (SCF):

.
If RxDivA/B connectors are not defined as in use in the SCF, the
switch is set to 2UD.
. If RxDivA/B connectors are defined as in use in the SCF, the switch
is set to 4UD.

The Site Configuration Files are used for commissioning the Flexi EDGE
BTS. For details, see Nokia Flexi EDGE BTS Commissioning.

The RxDivA/B connectors on the Dual TRX (EXxA) Module are also used
for configurations which require splitting a Dual TRX Module into separate
cell areas (such as cost-optimised configurations, 1+3).

For details about the Dual TRX Module connectors, see Dual TRX Module
(EXxA) Description.

C.2 Mixed Remote Tune Combiner (ECxA) and Dual Duplexer Module
(ERxA) configurations

Configurations with a mix of Remote Tune Combiner (ECxA) and Dual


Duplexer Module (ERxA) sectors are allowed. In these configurations,
BUS and PWR cabling should follow table Bus and internal power cabling
in mixed Remote Tune Combiner and Dual Duplexer Module
configurations. The table shows to which ESMA and ESEA BUS and PWR
connectors the cables from each EXxA and ECxA must be connected.

A maximum of two Remote Tune Combiner Modules and nine Dual


Duplexer Modules are allowed per site in mixed Remote Tune Combiner
and Dual Duplexer Module configurations. For RF cabling instructions,
follow the appropriate instructions for each sector.

76 (158) # Nokia Siemens Networks DN70128475


Issue 3-0 en
17/06/2008
Configuration features

Table 10. Bus and internal power cabling in mixed Remote Tune Combiner
and Dual Duplexer Module configurations

Module ESMA BUS ESMA PWR ESEA BUS ESEA PWR


ECxA 1 1 1/7
ECxA 2 2 2/8
EXxA 1 1 1/7
EXxA 2 2 2/8
EXxA 3 3
EXxA 4 4
EXxA 5 5
EXxA 6 6
EXxA 7 4/10 7
EXxA 8 5/11 8
EXxA 9 6/12 9

DN70128475 # Nokia Siemens Networks 77 (158)


Issue 3-0 en
17/06/2008
Creating FCOA Configurations

Appendix D Common configurations

D.1 Common cabinet configurations

The following table gives details about common, symmetrical hardware


configurations for FCIA and FCOA installations. For details about
asymmetric configurations, see Common sector configurations.

For details about RF cable autodetection and SCF template files, see
Nokia Flexi EDGE BTS Commissioning.

Table 11. Common FCOA and FCIA configurations

Config. TX RX # of # of # of # of # of # of # of # of # of
combin div. EXxA ERxA EWxx ECxA ESMA ESEA FPDA FPAA/ anten
1)
ing (FPMA) nas
1)

1+1 Bypass No/ 1 1 0 0 1 0 1 1 2


1UD
1 to 2 Bypass 2UD 1 1 0 0 1 0 1 1 2
Omni
2 2-way 1UD 1 1 1 0 1 0 1 1 1
3-4 4-way 1UD 2 1 3 0 1 0 1 1 1
3 Omni 2-way 2UD 2 1 2 0 1 0 1 1 2
4 Omni 2-way 2UD 2 1 2 0 1 0 1 1 2
5 Omni 4-way 2UD 3 1 5 0 1 0 1 1 2
6 Omni 4-way 2UD 3 1 5 0 1 0 1 2 2
7 Omni 4-way 2UD 4 1 6 0 1 0 1 2 2
8 Omni 4-way 2UD 4 1 6 0 1 0 1 2 2
3 to 4 RTC 2UD 2 0 0 1 1 1 1 1 2
Omni
5 to 6 RTC 2UD 3 0 0 1 1 1 1 1 to 2 2
Omni
7 to 8 RTC 2UD 4 0 0 2 1 1 1 2 2
Omni
9 to 10 RTC 2UD 5 0 0 2 1 1 2 2 2
Omni
11 to 12 RTC 2UD 6 0 0 2 1 1 2 3 2
Omni
1+1 Bypass 2UD 2 2 0 0 1 0 1 1 4

78 (158) # Nokia Siemens Networks DN70128475


Issue 3-0 en
17/06/2008
Common configurations

Table 11. Common FCOA and FCIA configurations (cont.)

Config. TX RX # of # of # of # of # of # of # of # of # of
combin div. EXxA ERxA EWxx ECxA ESMA ESEA FPDA FPAA/ anten
1)
ing (FPMA) nas
1)

2+2 Bypass 2UD 2 2 0 0 1 0 1 1 4


3+3 Bypass 2UD 4 4 0 0 1 0 1 2 6
(upgrade
opt.)
3+3 (cost Bypass 2UD 3 4 0 0 1 0 1 2 6
opt.)
4+4 Bypass 2UD 4 4 0 0 1 0 1 2 8
4+4 RTC 2UD 4 0 0 2 1 1 1 2
6+12 RTC 2UD 9 0 0 3 1 1 3 4 6
1+1+1/ Bypass 2UD 3 3 0 0 1 0 1 1/2 6
2+2+2
3 DP 2UD 3 2 3 0 1 0 1 2 3 or 4
or
4UD
4 DP 2UD 4 2 4 0 1 0 1 2 4
or
4UD
1+1+1 DP 2UD 3 3 3 0 1 0 1 2 6
2+2+2 DP 2UD 6 3 6 0 1 0 2 3 6
1+1+1 IDD/DP 4UD 6 6 0 or 3 0 1 0 1 2 12
2+2+2 IDD/DP 4UD 6 6 0 or 6 0 1 0 2 3 12
3+3+3 2-way 2UD 6 3 6 0 1 0 2 2 6
(upgrade
opt.)
4+4+4 2-way 2UD 6 3 6 0 1 0 2 3 6
4+4+4 RTC 2UD 6 0 0 3 1 1 2 3
5+5+5 4-way 2UD 9 3 15 0 1 1 2 3 6
6+6+6 4-way 2UD 9 3 15 0 1 1 3 4 6
7+7+7 4-way 2UD 12 3 18 0 1 1 3 5 6
6+6+6 RTC 2UD 9 0 0 3 1 1 3 4 6
8+8+8 4-way 2UD 12 3 18 0 1 1 3 5 6
2+2+2 & 2 Bypass 2UD 6 6 0 0 1 0 2 3 12
+2+2

DN70128475 # Nokia Siemens Networks 79 (158)


Issue 3-0 en
17/06/2008
Creating FCOA Configurations

1)
Optional depending on the external power source.

Table 12. Cost-optimised and antenna-optimised configurations

Config. TX RX div. # of # of # of # of # of # of # of FPAA/ # of


combining EXxA ERxA EWxx ESMA ESEA FPDA (FPMA) 1) antennas
1) 2) 3)

3+3 cost- 2-way 2UD 3 2 4 1 0 1 2 4


opt.
5+5 cost- 4-way 2UD 5 2 10 1 0 2 2 4
opt.
3+3+3 2-way 2UD 5 3 6 1 0 2 3 6
cost-opt.
6 ant-opt. 2-way 2UD 3 2 3 1 0 1 2 3
6+6 ant- 2-way 2UD 6 3 6 1 0 2 3 6
opt.
6+6+6 ant- 2-way 2UD 9 5 9 1 1 3 4 9
opt.
12 ant-opt. 4-way 2UD 6 2 9 1 0 2 3 3
12+12 ant- 4-way 2UD 12 3 18 1 1 3 5 6
opt.
3 ant-opt. Bypass 2UD 2 2 0 1 0 1 2 3
3+3 ant- Bypass 2UD 3 3 0 1 0 1 2 6
opt.

1)
Optional depending on the external power source.

2)
Three FPDAs are needed for a full 24-carrier configuration.

3)
One FPAA supports five normal carriers and one FPMA provides a
maximum of four FPAAs slots.

80 (158) # Nokia Siemens Networks DN70128475


Issue 3-0 en
17/06/2008
Common configurations

D.2 Common sector configurations

Table 13. Common sector configurations

# of TX RX div. # of # of # of # of # of # of # of
carriers combining EXxA ERxA EWxx ECxA ESMA ESEA antennas
1 Bypass 1UD 1 1 0 0 1 0 1
1 Bypass 2UD 1 1 0 0 1 0 2
2 Bypass 2UD 1 1 0 0 1 0 2
3 Bypass 2UD 2 2 0 0 1 0 3
4 Bypass 2UD 2 2 0 0 1 0 4
1 DP 2UD 1 1 1 0 1 0 2
2 DP 2UD 2 1 2 0 1 0 2
3 DP 2UD or 3 2 3 0 1 0 2UD=3,
4UD 4UD=4
4 DP 2UD or 4 2 4 0 1 0 4
4UD
1 IDD or DP 4UD 2 2 IDD=0, 0 1 0 4
DP=1
1 IDD 2UD 1 1 0 0 1 0 2
2 IDD or DP 4UD 2 2 IDD=0, 0 1 0 4
DP=2
2 IDD 2UD 2 2 0 0 1 0 4
2 2-way 1UD 1 1 1 0 1 0 1
3 2-way 2UD 2 1 2 0 1 0 2
4 2-way 2UD 2 1 2 0 1 0 2
3-4 4-way 1UD 2 1 3 0 1 0 1
5 to 8 4-way 2UD 3 to 4 1 5 to 6 0 1 0 2
Up to 6 RTC 2UD Up to 0 0 1 1 1 2
3
(6-way)
7 to 12 RTC 2UD 4 to 6 0 0 2 1 1 2
(6-way)

DN70128475 # Nokia Siemens Networks 81 (158)


Issue 3-0 en
17/06/2008
Creating FCOA Configurations

Appendix E Creating common configurations

E.1 4+4+4 2-way 2UD configuration in FCOA

For creating this configuration, you need:

. 6 Dual TRX Modules (EXxA)


.
3 Dual Duplexer Modules (ERxA)
. 1 System Module (ESMA)
.
6 Wideband Combiner Submodules (EWxx)
. 1 Flexi Cabinet for Outdoor (FCOA)
.
If 24V DC or AC power is used, see module installation order in
Optional power modules (FPDA and FPMA) in Flexi EDGE BTS
configurations in document Installing Nokia Flexi EDGE BTS
Optional Items.

The following figures show the module installation order and cabling for
this configuration. For detailed instructions on how to install the cabinet
and install and cable the modules, see document Installing Flexi Cabinet
for Outdoor (FCOA) and sections Installing the modules for a 2+2+2
configuration and Connecting cabling for a 2+2+2 configuration in this
document.

Note that the air guide plate is required if the System Module or System
Extension Module are installed in the vertical left rack. Otherwise, use
dummy panels in the empty slots.

The System Module can be installed horizontally or vertically as shown in


the figures below. Vertical installation is recommended if you are going to
expand to an 8+8+8 configuration later.

82 (158) # Nokia Siemens Networks DN70128475


Issue 3-0 en
17/06/2008
Creating common configurations

EXxA
DN
EWxx
ERxA

EXxA
EWxx

ESMA

EXxA
DN
EWxx

ERxA

EXxA
EWxx
EXxA
DN
EWxx
ERxA

EXxA
EWxx

Modules

Figure 37. Modules in a 3+3+3/4+4+4 FCOA configuration, ESMA horizontal

If you are using the optional power modules or other optional items, see
instructions in Installing Nokia Flexi EDGE BTS Optional Items.

DN70128475 # Nokia Siemens Networks 83 (158)


Issue 3-0 en
17/06/2008
Creating FCOA Configurations

EXxA
DN
EWxx

ERxA
Air guide EXxA
plate EWxx
EXxA
ESMA DN
EWxx

ERxA

EXxA
EWxx
EXxA
DN
EWxx

ERxA

EXxA
EWxx

Space for
optional
MIBBU

Modules
DN70239442

Figure 38. Modules in a 3+3+3/4+4+4 FCOA configuration, ESMA vertical

84 (158) # Nokia Siemens Networks DN70128475


Issue 3-0 en
17/06/2008