Model TE 172 Pumping System MIDPRESS peristaltic finger system ( A newly system to provide accurate infusion without pressing the tubing completely ) Delivery Rate 0.1 1200 mL/h ( 0.1 99.9 mL/h: 0.1 mL/h step, 100 1200 mL/h: 1 mL/h step ). The delivery rate can be set in 1 mL/h step throughout the range by the internal mode select switch Accuracy Within 5 % infusion set: Specified TERUFUSION infusion sets for pump ( TSPA ) Solution: water/saline Test time: second hour Delivery rate: 1.0 mL/h or more Temperature: 250 C Volume Delivered range 0.0 to 9,999 mL Delivery Limit range 1 9,999 mL ( 1 mL step ) or - - - - ( Delivery Limit Free ) Purge flow function Higher than 500 mL/hours Alarms Air, Occlusion, Flow Error, Door, Low Battery
Operation indicator flashes red and the alarm message
come on. Pump stops except during the LOW BAT alarm Occlusion Detection Pressure 13.3 133.3 kPa ( 100 1.000 mmHg / 0.1 1,4 kgf/cm2 ) The detection pressure can be adjusted in 3 level ( L, M, H ) within the above range Infusion Complete Function When the total volume delivered reaches the preset ( Completion ) delivery limit, light and buzzer sound notifies the operator Nurse Call Alarm Output an alarm relay contact ( Can be connected to nurse call ) Contact rating: DC 12 Volt, 1.0 Ampere Computer Interface RS-232C/RS-485 Special Functions KEEP VEIN OPEN ( KVO ) function KVO function continues infusion at flow rate of 1 mL/h after delivery limit ( preset volume ) has been reached. Tubing clamp function When the door is opened, tubing is automatically clamped Volume delivered clear function Holding down the [ mL CLEAR ] switch for about 0.5 second clears the volume delivered reading Time remaining display Battery capacity indicator ( in 3 levels ) Adjustable display brightness ( can be switched to 2 level ) Adjustable buzzer volume ( in 3 level ) Operation history function ( Storage / display of operation history ) Standby function Repeat alarm function Start reminder alarm Operating conditions + 10 to +400 C, Humidity : 30 to 85 % Storage Conditions Temperature : - 20 to +450 Celcius Humidity : 10 95 % RH ( no condensation ) Power Supply AC : 100 240 Volt, 50/60 Hz DC : 12 15 VDC Internal Nickel Cadmium Battery can run the pump continously for about 3 hours. Condition : New battery, Delivery rate : 25 mL/h, Temperature: 250C, Battery charging 15 hours for the first use Power Consumption 28VA ( Watt )/AC 100 240 Volt 11 VA ( Watt )/ DC power Classification Class I and Internal Power Supply Type CF, IPX1 Continuous Operation Dimensions 100 mm (W) x 215 mm ( H) x 208 mm ( D ) Weight Approx 3.7 kg Body Weight Mode Dose Rate : 0.01 99.9 g/kg/min ( Dose Rate Calculation ) ( 0.01g/kg/min step ) Body Weight : 0.1 300.0 kg ( 0.1 kg step ) Drug mass : 0.1 999.9 mg ( 0.1 mg step ) Solution Volume : 0.1 999.9 mL ( 0.1 mL step )
Memory Function The latest five patterns of the above four parameter are automatically saved and can be displayed
Analysis of Commercial Proanthocyanidins. Part 1 The Chemical Composition of Quebracho (Schinopsis Lorentzii and Schinopsis Balansae) Heartwood Extract 2012 Phytochemistry 1