Sei sulla pagina 1di 2

Specifications per controller unless otherwise FAS8020 FAS8040 FAS8060 FAS8080 EX

stated

8.2.3 7-Mode 8.2.3 7-Mode 8.2.3 7-Mode 8.2.3 7-Mode


Max Raw Capacity (HA) 2880 TB 4320 TB 7200 TB 8640 TB
Recommended Min Raw Capacity Array LUNs 3150[3] 4500[3] 8100[3] 16200[3]
(GB)
Absolute Min Raw Capacity Array LUNs (GB) 1890[4] 2700[4] 4860[4] 9720[4]
Max Storage Devices (HA) 480 (Array LUNs & disks) 720 (Array LUNs & disks) 1200 (Array LUNs & disks) 1440 (Array LUNs & disks)
Max DS2246 Shelves (HA) 20 30 50 60
Max DS4243 Shelves (HA) 20 30 50 60
Max DS4246 Shelves (HA) 20 30 50 60
Max DS4486 Shelves (HA) 10 15 25 30
Max DS14-Class Shelves (HA) 24 48 48 103
Max Nodes Per Cluster - NAS[1] Not Supported Not Supported Not Supported Not Supported
Max Nodes Per Cluster - SAN[1] Not Supported Not Supported Not Supported Not Supported
Aggregate Size 32 bit (TiB) 16 16 16 16
Aggregate Size 64 bit (TiB) 324 324 400 400
Min Size for an Array LUN Aggregate (GB) 40 80 80 160
Flex Volume Size 32 bit (TiB) 16 16 16 16
Flex Volume Size 64 bit (TiB) 70 100 100 100
Max Infinite Volume Data Constituent Size (TiB) Not Supported Not Supported Not Supported Not Supported
Max Volume Count (Single) 500 500 500 500
Max Array LUN Size (GB) 5856[5] 5856[5] 5856[5] 5856[5]
Min Array LUN Size (GB) 1.05 1.05 1.05 1.05
Min Array LUN Size Root Volume (GB) 401 401 401 401
Min Root Volume Size (Single/HA) 250 GB / 250 GB 250 GB / 250 GB 250 GB / 250 GB 250 GB / 250 GB
Spare Core Array LUN Min Size (GB) 32 45 81 162
Max RAID Groups in an Aggregate 150 150 150 150
Block Size (bytes) 512 512 512 512
Neighborhood Visible and Assigned Devices - - - -
Chassis Height 5.12" (13.00 cm) 10.20" (25.90 cm) 10.20" (25.90 cm) 10.20" (25.90 cm)
Chassis Width with Mounting Flanges
Chassis Width without Mounting Flanges 17.60" (44.70 cm) 17.60" (44.70 cm) 17.60" (44.70 cm) 17.67" (44.88 cm)
Chassis Depth with Cable Mgmt 23.92" (60.75 cm) 24.29" (61.70 cm) 28.90" (73.40 cm) 29.00" (73.66 cm)
Chassis Depth without Cable Mgmt 24.29" (61.70 cm)
Rack Units (Single/HA) 3/3 6/6 6 / 6 (without IOXM) 6 / 12 (with IOXM)
6 / 12 (with IOXM)
Chassis Weight One Controller Module 63.05 lb (28.6 kg) 100.97 lb (45.8 kg) 102.07 lb (46.3 kg) -
Chassis Weight Two Controllers Modules 74.08 lb (33.6 kg) 119.49 lb (54.2 kg) 121.47 lb (55.1 kg) -
Chassis Weight Controller + IOXM - - 115.08 lb (52.2 kg) 121.47 lb (55.1 kg)
Front Clearance (Cooling/Maintenance) 10.01" (25.40 cm) 5.99" (15.20 cm) 5.99" (15.20 cm) 5.99" (15.20 cm)
30.02" (76.20 cm) 30.02" (76.20 cm) 30.02" (76.20 cm) 30.02" (76.20 cm)
Rear Clearance (Cooling/Maintenance) 12.02" (30.50 cm) 12.02" (30.50 cm) 12.02" (30.50 cm) 12.02" (30.50 cm)
30.02" (76.20 cm) 36.01" (91.40 cm) 36.01" (91.40 cm) 36.01" (91.40 cm)
Operating Temperature Range 50 to 104 deg F 50 to 104 deg F 50 to 104 deg F 50 to 104 deg F
10 to 40 deg C 10 to 40 deg C 10 to 40 deg C 10 to 40 deg C
Storage Temperature Range -40 to 158 deg F -40 to 158 deg F -40 to 158 deg F -40 to 158 deg F
-40 to 70 deg C -40 to 70 deg C -40 to 70 deg C -40 to 70 deg C
Transit Temperature Range -40 to 158 deg F -40 to 158 deg F -40 to 158 deg F -40 to 158 deg F
-40 to 70 deg C -40 to 70 deg C -40 to 70 deg C -40 to 70 deg C
Operating Relative Humidity 20 to 80 % 20 to 80 % 20 to 80 % 20 to 80 %
Storage Relative Humidity 5 to 95 % 5 to 95 % 5 to 95 % 5 to 95 %
Transit Relative Humidity 5 to 95 % 5 to 95 % 5 to 95 % 5 to 95 %
Operating Altitude 0 to 9997.44 ft 0 to 9997.44 ft 0 to 9997.44 ft 0 to 9997.44 ft
0 to 3048 m 0 to 3048 m 0 to 3048 m 0 to 3048 m
Storage Altitude 0 to 39989.8 ft 0 to 39989.8 ft 0 to 39989.8 ft 0 to 39989.8 ft
0 to 12192 m 0 to 12192 m 0 to 12192 m 0 to 12192 m
Transit Altitude 0 to 39989.8 ft 0 to 39989.8 ft 0 to 39989.8 ft 0 to 39989.8 ft
0 to 12192 m 0 to 12192 m 0 to 12192 m 0 to 12192 m
Acoustic Noise - Sound Power 7.5 bels 7.5 bels 7.6 bels 7.5 bels
Acoustic Noise - Sound Pressure 61.3 dBA 61.3 dBA 62.4 dBA 61.3 dBA
Input Power Voltage 100 to 120, 200 to 240 100 to 120, 200 to 240 100 to 120, 200 to 240 100 to 120, 200 to 240

Processor (Single)[2] 1 x 64-bit 6-core 2.00 Ghz 1 x 64-bit 8-core 2.10 Ghz 2 x 64-bit 8-core 2.10 Ghz 2 x 64-bit 10-core 2.80 Ghz
Memory (Single)[2] 24 GB 32 GB 64 GB 128 GB
NVRAM (Single)[2] 4 GB (Onboard) 8 GB (Onboard) 8 GB (Onboard) 16 GB (Onboard)
Ethernet Ports (Single)[2] 2 x RJ45 (1Gbps) 4 x RJ45 (1Gbps) 4 x RJ45 (1Gbps) 4 x RJ45 (1Gbps)
2 x SFP+ (10Gbps) 4 x SFP+ (10Gbps) 4 x SFP+ (10Gbps) 4 x SFP+ (10Gbps)
Fibre Channel Ports (Single)[2]
UTA2 Ports (Single)[2] 2 x SFP+ (16Gbps)[6] 4 x SFP+ (16Gbps)[6] 4 x SFP+ (16Gbps)[6] 4 x SFP+ (16Gbps)[6]
Expansion Slots (Single)[2] 2 x PCIe3 4 x PCIe3 4 x PCIe3 (without IOXM) 12 x PCIe3 (with IOXM)
12 x PCIe3 (with IOXM)
SAS Ports (Single)[2] 2 x QSFP (6Gbps) 4 x QSFP (6Gbps) 4 x QSFP (6Gbps) 4 x QSFP (6Gbps)
Max Back-End FC Loops (HA) 4 16 14 16
Min version of Data ONTAP 7
Min version of Data ONTAP 8 (both modes) 8.2.1 8.2.1 8.2.1 8.2.2
EOA
EOS

Notes ID Notes Description


1 Maximum number of nodes within a cluster is determined by platform which supports the fewest number of nodes
2 Values will have to be doubled for HA configurations.
3 Defines the system capacity required for storing the core file on array LUNs whenever the spray core option is set on the Data ONTAP systems. Assumes no
compression and guaranteed core dump.
4 Defines the system capacity required for storing the core file on array LUNs whenever the spray core option is set on the Data ONTAP systems. Assumes 60 percent
compression but core dump is not guaranteed.
5 The maximum LUN size provided is a number determined by the V-Series/FlexArray product team. Supported maximum LUN size will be the lesser of published
maximum LUN size by NetApp and maximum LUN size supported by the backend array
6 The onboard UTA2 ports can be configured as FC Target/Initiator or CNA (FCoE target/Ethernet). The UTA2 ports are based on a dual port ASIC and both ports on
each ASIC must be set to the same mode (enforced by Data ONTAP). Install X6599A-R6 10GbE SFP+ modules or approved copper twinax cables when using in CNA
(FCoE target/Ethernet) mode. Install X6596-R6 16Gb FC SFP+ module when using in FC Target/Initiator mode.

Potrebbero piacerti anche