Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
N
4NOS. M20 GR 8.8 HIT - RE 500 + HIT - V.
EMBEDMENT DEPTH = 275 mm SB1 @ 1250 c/c GARAGE BAY
ROOF LEVEL 8mm STIFFENER PLATE
__________
A
B1
BL
QI
75
S202
75
500x350x20 Notes
8mm GUSSET PLATE
STIFFENER BASE PLATE
SB3
6
150
8mm STIFFENER
350
500
700
700
20 mm BRACKET SB3
SB1
(AT MID SPAN)
20mm
200
BRACKET
75
EA 75x75x6 EA 75x75x6
50 250 50 4000
4 NOS. M20 GR 8.8HIT-RE 500 + HIT - V
350 EMBEDMENT DEPTH = 275mm
20mm NON SHRINKAGE GROUT
500x350x20
BASE PLATE
P-RB2
A SECTION B1 SECTION
S122 SCALE 1 : 10
B SECTION S202 SCALE 1 : 5
S122 SCALE 1 : 20
__________
D1 Conditions of Use. This document may only be used by GHD's client (and any other
100
20mm NON SHRINKAGE person who GHD has agreed can use this document) for the purpose for which it was
S202 GROUT prepared and must not be used by any other person or for any other purpose.
2000 6mm STIFFENER PLATE
50
@ CENTER
4
Master Developper / Owner
150
250
700
700
Planning & Development
50
6mm GUSSET PLATE 15mm BRACKET PO Box 94449, Abu Dhabi, U.A.E
SB4 SB4
STIFFENER T: +971 (0) 2 505 5000
300
50 200 50 F: +971 (0) 2 575 8300
4 NOS. M16 GR8.8 HIT - RE 500+ HIT - V
250
Lead Consultant
P-RB2
D SECTION D1 SECTION
S122 SCALE 1 : 20 SCALE 1 : 5
S202
Specialist Consultant
Specialist Consultant
Third Party
Operational Advisor
Client
ADAC
Project
MIDFIELD TERMINAL FIRE
STATION
Title
Approved Approver
(Project Director)
Date
This Drawing must not be used for Construction unless signed as Approved
Original Size
Drawing No:
A1
76-10526- S202 Rev: A
Plot Date: 5/03/2015 10:40:11 PM Cad File No: C:\Users\rbuduan\Documents\76-10526_Midfield Fire Station-Central_rbuduan.rvt