______________________________HONEYWELL

AT SERIES TRANSFORMERS
FOR ANY 24V CIRCUITS IN HEATING/COOLING CONTROL SYSTEMS
Primary Secondary
Voltage Output
Voltage (Open VA
Order No. (50/60 Hz) Conn. circuit) Conn. Mounting Rating
AT72D1683 120V 9" leadwires 26.5 2 screw terminals Can be foot-mounted; plate mounted on 4"x4" , 40 VA
octogan, or 2"x4" electrical boxes (transformer all
above plate or 3/4" above plate); or clamp-mounted
via a junction box knockout.

AT87A, AT88A NEMA STANDARD TRANSFORMERS


Used primarily for powering 24V air conditioning circuits. Can also be used in other applications that do not exceed the listed ratings.

Primary Secondary
Voltage
(Open Output (100%
Order No. Voltage (50/60 Hz) Conn. circuit) Conn. power factor) Mounting Overload Protection
AT87A1106 120/208/240 Vac 13" leads 28 2 screw terminals 50 VA Foot-mounted Built-in protection
or 4" x 4" plate

L482 REFRIGERATION CONTROLLER


Used to limit or control temperatures in air conditioning systems or refrigerated enclosures.
Capillary Capillary
Order No. Application Reset Type Range Length Switching Action
L482A1004 For temperature or limit Manual 15-55oF. 20' 2 spst, one N.C.,
control of air conditioning one N.O.
systems and refrigeration

L4006, L6006 AQUASTAT CONTROLLERS


IMMERSION TYPE CONTROLLERS FOR LIMITING OR REGULATING TEMPERATURES OF LIQUIDS
4
IN BOILERS OR TANKS
Totally enclosed Micro Switch snap-acting switches operates on temperature rise to setpoint. Visible control point scale and extrenal
adjustment screw permit easy setting. Horizontal or vertical insertion of the sensing element. Direct or well immersion of the sensing
element. Models available for strap-on mounting. Remote bulb model may be used to sense air temperature in ducts and in outside
air sensing applications. TRADELINE models include well adapter and tube of heat-conductive compound. Select models have wells.

Electrical Ratings:
Full Load
Temp. Midscale
Order No. Application Switch Action Range Differential Includes 120 Vac 240 Vac
L4006A1678 High or Low Limit spst,contacts break on 100-240oF. 5-30oF. Adj. 3" insulation, stop 8.0A 5.1A
temp.rise factory set at 240oF.

L4006A1959 High or Low Limit spst,contacts break on 40-180oF. 2oF. Fixed 1 1/2" insulation 2.6A 1.3A
temp.rise
L4006E1067 High Limit spst,contacts break on 110-290oF. Manual Reset 3" insulation, stop 8.0A 5.1A
temp.rise factory set at 240oF.

L6006A1145 Circulator, high or spdt 100-240oF. 5-30oF, Adj. 3" insulation, stop 8.0A 5.1A
low limit factory set at 240oF.

STRAP ON AQUASTAT
L6006C1018 Circulator, high or spdt 65-200oF. 5-30oF. Adj. Bracket for strap-on 8.0A 5.1A
low limit mounting, stop factory
o

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 127


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL______________________________
L4008, L6008 REMOTE BULB AQUASTAT
FOR LIMITING OR REGULATING TEMPERATURES OF LIQUIDS IN BOILERS OR TANKS
Remote temperature sensing element detects and responds rapidly to temperature changes. Totally enclosed Micro
Switch™ snap-acting switch. Visible control point scale and external adjustment screw permit easy setting. Horizontal
or vertical mounting of the remote element into boiler, tank, or other container. Case mounts to a vertical surface.

Max.
Ambient
Midscale Temp. at
Order No. Description Switch Action Temp. Range Differential Element
L4008E1156 High Limit Contacts break 110-290oF. Manual 345oF.
on temp.rise Reset

L6008A1192 Circulator and low limit spdt 100-240oF. 5-30oF. Adj. 265oF.
Electrical Ratings: Full Load: 120 Vac/8.0A, 240 Vac/5.1A
Bulb size: 3/8" X 2 7/8"

L4081 MULTIPLE AQUASTAT CONTROLLERS


HIGH LIMIT, LOW LIMIT AND/OR CIRCULATOR CONTROLLER USED TO REGULATE
BOILER WATER TEMPERATURE IN GAS- OR OIL-FIRED HYDRONIC HEATING
SYSTEMS
Immersion type, liquid-filled sensing element actuates two snap switches. Controller may be mounted in any position
and does not require leveling. Adjustments made inside front cover for accessibility

Adjustable
Order No. Description Switching Action Differential
L4081A1023 130-240oF.High Limit/110-220 o F. Low Limit Spst, high limit Spst, Yes, on low limit
low limit

4 IMMERSION WELLS
Insertion/
Insulation Bulb Max. Bulb
Order No. Connection Depth Diameter Length Includes
COPPER
112622AA 1/2" NPT 1 1/2" 1/2" 4" Spring clip
112630AA 3/4" NPT 1" 1/2" 4 1/4" Spring clip
121371A 1/2" NPT 1 1/2" 3/8" 3" Mounting clamp
121371B 3/4" NPT 1 1/2" 3/8" 3" Mounting clamp
121371L 1/2" NPT 3" 3/8" 3" Mounting clamp
STAINLESS STEEL
121371E 1/2" NPT 1 1/2" 3/8" 3" Mounting clamp

M436, M836 DAMPER MOTORS


SPRING-RETURN MOTORS FOR TWO-POSITION ZONE OR DAMPER
Use with two-wire thermostats or other spst controllers. With thermal breaker for overload protection during the lifting stroke or if
motor stalls.
Nominal Nominal
Voltage Opening Opening Max. Load Breakaway Damper
Order No. (50/60 Hz) Current Time Torque Torque1 Blade Area
M436A1116 120 Vac 0.37A 30 sec. 20 in-lb. 30 in-lb 13 sq.ft.

1
Maximum torque available to overcome large loads such as a seized damper or valve. Not to be used continuously at this rating.

128 www.federalcorp.com
______________________________HONEYWELL
M6184D MODUTROL MOTORS
REVERSING, THREE-WIRE SPDT OF FLOATING CONTROL MOTORS USED
TO OPERATE DAMPERS AND VALVES. REPLACES M644A-E MOTORS
Available with fixed or adjustable stroke, Double-ended Crankshaft 3/8" square. UL listed. CSA
certified.
Power
Voltage1
Order No. (50/60 Hz) W VA Torque2 Timing3 Stroke
M6184D1035 24 15 17 150 lb/in. 30-60 sec. 90-160o
1
Internal actuator motor and circuitry operates from 24 Vac. Line voltage models shipped with
internal transformers.
2
Normal running torque. Breakaway torque rating is 2X normal running torque and is the maximum
torque available to overcome occasional large loads such as a seized damper or valve. MOTOR NOT
TO BE USED CONTINUOUSLY AT BREAKAWAY TORQUE RATING.
3
Shorter timing applies to 90o stroke.

M6284D MODUTROL MOTORS


REVERSING, THREE-WIRE FLOATING-CONTROL MOTORS WITH FEEDBACK
POTENTIOMETER. USED WITH CONTROLLERS THAT PROVIDE A SPDT OUTPUT
TO OPERATE DAMPERS AND VALVES. REPLACES M944B,E,G,S MOTORS
Available with fixed or adjustable stroke, Double-ended Crankshaft 3/8" square untapped. UL listed. CSA
certified.
Power

Voltage1
Order No. (50/60 Hz) W VA Torque2 Timing3 Stroke
M6284D1000S 24 15 17 150 lb/in. 30-60 sec. 90-160o
1
Internal actuator motor and circuitry operates from 24 Vac. Line voltage models shipped with internal
transformers.
2
Normal running torque. Breakaway torque rating is 2X normal running torque and is the maximum torque
available to overcome occasional large loads such as a seized damper or valve. MOTOR NOT TO BE USED

4
CONTINUOUSLY AT BREAKAWAY TORQUE RATING.
3
Shorter timing applies to 90o stroke.

M7284C MODUTROL MOTORS


PROPORTIONAL MOTORS USED TO OPERATE DAMPERS AND VALVES
Replaces M744S,T,Y nd M745S,T,Y motors. Use with a modulating 4-20 m-A current.

Power

Voltage
Order No. (50/60 Hz) W VA1 Torque2 Timing Stroke Includes
2 aux.
M7284C1000 120 23 29 150 lb/in. 30 sec. 90 Switches
1
VA figures listed are for 60 Hz. Values will be higher by 5VA at 50 Hz.
2
Torque given is normal running torque. Breakaway torque rating is 2X normal running torque and is the maximum torque
available to overcome occasional large loads such as a seized damper or valve. MOTOR NOT TO BE USED CONTINUOUSLY AT
BREAKAWAY TORQUE RATING.

M8185D MODUTROL MOTORS


TWO-POSITION, SPRING-RETURN MOTORS USED TO OPERATE DAMPERS AND
VALVES. REPLACES M445A,D; M845A,C,E; AND M865B MOTORS
Integral helical spring returns motor shaft to normal position (Full closed) on power interruption. Double-ended
Crankshaft, 3/8" square. US listed. CSA certified.
Power

Voltage1
Order No. (50/60 Hz) W VA Torque2 Timing3 Stroke
M8185D1006 24 20 21 50 lb/in. 30-60 sec. 90-160o
1
Internal actuator motor and circuitry operates from 24 Vac. Line voltage models shipped with internal
transformers.
2
Normal running torque. Breakaway torque rating is 2X normal running torque and is the maximum torque
available to overcome occasional large loads such as a seized damper or valve. MOTOR NOT TO BE USED
CONTINUOUSLY AT BREAKAWAY TORQUE RATING.
3
Shorter timing applies to 90o stroke.

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 129


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL______________________________
M9164A,C,D; M9174B,C,D MODUTROL MOTORS
REVERSING, PROPORTIONAL MOTORS USED TO OPERATE DAMPERS AND
VALVES. REPLACES M934 MOTORS
Available with fixed or adjustable stroke; refer to order table. All M9164 motors have an electronic drive
circuit. One series 90 controller can drive up to six Modutrol motors using 4074BYK Resistor Bag Assembly
or 221508A Resistor Board Kit. Interface modules available for series 70 (electronic) control. Double-ended
Crankshaft 3/8" square. UL listed. CSA certified.

Power

Voltage1
Order No. (50/60 Hz) W VA Torque2 Timing3 Stroke
M9164D1009 24 14 15 35 lb/in. 30-60 sec 90-160o
M9174D1007 24 21 27 75 lb/in 30-60 sec 90-160o
1
Internal actuator motor and circuitry operates from 24 Vac. Line voltage models shipped with internal
transformers. Separate transformer may be required for 24V models for proper system operation.
2
Normal running torque. Breakaway torque rating is 2X normal running torque and is the maximum torque
available to overcome occasional large loads such as a seized damper or valve. MOTOR NOT TO BE USED
CONTINUOUSLY AT BREAKAWAY TORQUE RATING.
3
Shorter timing applies to 90o stroke.

M9184A,C,D,F; M9194D,E MODUTROL MOTORS


REVERSING, PROPORTIONAL MOTORS USED TO OPERATE DAMPERS AND VALVES.
REPLACES M944A,C,D AND M954 MOTORS.
Available with fixed or adjustable stroke. All M9184 motors have an electronic drive circuit. One series 90 controller can drive up
to six Modutrol motors using 4074BYK Resistor Bag Assembly or 221508A Resistor Board Kit. Interface modules available for
series 70 (electronic) control. Double-ended Crankshaft 3/8" square. Models available with tapped (8/32) shafts for Flame
Safeguard applications. UL listed. CSA certified.

Power

4 Order No.
Voltage1
(50/60 Hz) W VA Torque3 Timing2 Stroke Includes
Tapped
M9184D1021 24 18 19 150 lb/in. 30-60 sec. 90-160 shaft
M9194D1003 24 18 19 300 lb/in. 120-240 sec. 90-160 -
1
Internal actuator motor and circuitry operates from 24 Vac. Line voltage models shipped with internal transformers.
2
Shorter timing applies to 90o stroke.
3
Torque given is normal running torque. Breakaway torque rating is 2X normal running torque and is the maximum torque
available to overcome occasional large loads such as a seized damper or valve. MOTOR NOT TO BE USED CONTINUOUSLY AT
BREAKAWAY TORQUE RATING.

M9185A,C,D,E MODUTROL MOTORS


REVERSING, PROPORTIONAL SPRING-RETURN MOTORS USED TO OPERATE DAMPERS
AND VALVES. M9184, M9186 REPLACES M945A,D,F AND M955 MOTORS. M9175
REPLACES M965 AND M975 MOTORS
Integral helical spring returns motor shaft to normal position (Full closed for M9175 and M9185, full open for M9186) on
power interruption. Available with fixed or adjustable stroke. All M9175, M9185 and M9186 motors have an electronic drive
circuit. One series 90 controller can drive up to six Modutrol motors using 4074BYK Resistor Bag Assembly or 221508A
Resistor Board Kit. Interface modules available for series 70 (electronic) control. Double-ended Crankshaft 3/8" square. UL
listed. CSA certified.

Power
Voltage1
Order No. (50/60 Hz) W VA Torque2 Timing3 Stroke
M9185D1004 24 23 24 60 IB/IN. 30-60 SEC. 90-160o

1
Internal actuator motor and circuitry operates from 24 Vac. Line voltage models shipped with internal transformers.
2
Normal running torque. Breakaway torque rating is 2X normal running torque and is the maximum torque available to
overcome occasional large loads such as a seized damper or valve.MOTOR NOT TO BE USED CONTINUOUSLY AT BREAKAWAY
TORQUE.
3
Shorter timing applies to 90o stroke.

130 www.federalcorp.com
______________________________HONEYWELL
M9484D, E, F MODUTROL MOTORS
REVERSING, PROPORTIONAL MOTORS USED TO DRIVE BURNER FIRING RATE VALVES,
DAMPERS OR AUXILIARY EQUIPMENT. REPLACES M941A, C, D MOTORS
Designed for flame safeguard applications in commercial/industrial oil or gas burner systems. With vibration-resistant electronic
balancing circuit. Regulated by 3-wire proportional controller. Stroke is field selectable to 90 or 160 o. Double-ended Crankshaft,
3/8" square. Dead Weight Load on shaft: Power end-200 lbs.; auxiliary end-100 lbs. Dimensions: 7 3/16"(H) x 5 5/8"(W) x 7
5/16"(D). Electrical rating: 24V @ 50/60 Hz.

Timing

Order No. 90o Stroke 160o Stroke Running Torque 2 Additional Features
STANDARD MODEL
M9484D1010 30 sec. 60 sec. 150 lb/in. Shipped in 90o position
STANDARD MODEL WITH 1 SPDT AUXILIARY SWITCH3
M9484E1033 30 sec. 60 sec. 150 lb/in. Shipped in 90o position, switch set at 4o, with tapped
shaft
STANDARD MODEL WITH 2 SPDT AUXILIARY SWITCHES 3
M9484F1031 30 sec. 60 sec. 150 lb/in.
Shipped in 90o position, 1 switch set at 5o and 1 set
at 54o of 90o stroke. With tapped shaft.
1
Shorter timing applies when 90o stroke is selected.
2
Normal running torque. Breakaway torque is 2X normal running torque and is the maximum torque available to overcome occasional
large loads such as a seized damper or valve. Motor not to be used continuously at breakaway torque rating.
3
Cam-adjusted Micro Switch auxilary switch. Auxilary switch differential factory set at 1o (selectable for 10o). One contact switch
ratings: Full load: 7.2A@120V, 3.6A@240V; Locked rotor: 43.2A@120V,21.6A@24V.

PARTS AND ACCESSORIES FOR HONEYWELL MOTORS


Order No. Application/Description Use With
HARDWARE
220736A 1 spdt switch for internal mounting Auxiliary equipment for Mod IV motors
220736B 2 spdt switches for internal mounting Auxiliary equipment for Mod IV motors

4
220738A Mounting adapter for Mod IV motors Auxiliary equipment for Mod IV motors
221455A Motor crank arm Auxiliary equipment for Mod IV motors
221508A Resistor board. Any M91XX Mod IV motor, multiple configuration
4074EDC Resistor kit Converts Series 90 Mod motor to 4-20mA input
TRANSFORMERS
198162AA Internal transformer,120V/208V/240V Mod IV motors
198162EA Internal transformer,120V Mod IV motors
5001746001 Internal transformer, 24V/120V/230V Mod IV motors
5001746003 Internal transformer, 120V Mod IV motors

ML7984 VALVE ACTUATORS


Mount directly, without a linkage, on V5011A,C,F,G, V5013F and V5045 1/2- to 3-inch water and steam,
threaded valve bodies only. Compact size is ideal for unit heaters, fan coil units, narrow ceiling plenums
and computer room motorized valve applications. 160-pound minimum valve closing force, either direction.
Stem travel is 3/4". Non-spring return. Timing is 63 seconds for 3/4" travel.

Order No. Control Signal Comments


ML7984A4009
2-10V or 10-2Vdc,4-20 mA or 20-4 mA, Use with V5011/V5013 valves. Field
135 ohm, or electronic Series 90 selectable for either direct or reverse acting.

DAMPER/VALVE ACTUATOR ACCESSORIES


Order No. Model No. Description
BALLJOINT-5 27518 SWIVEL BALL JOINT FOR 5/16 ROD for dampers.
26026G 26026G 1/2 X 4-15/16 CRANK ARM for dampers.
27174B 27174B 7/16" X 4-15/16" Damper Crank Arm Assembly
PUSHROD-5X360 27520K PUSH ROD LINKAGE 5/16 X 36 for dampers.
7616BR 7616BR Crank Arm for Modutrol Motors

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 131


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL______________________________
NXL AND NXS VARIABLE FREQUENCY DRIVES
From simple HVAC applications to closed-loop process control applications, you can depend on the Honeywell NX series
to control anything from simple fans, pumps and compressors to elevators, cranes or winders. NXS models offer the
greatest application versatility for multiple control applications. Together these versatile performers feature modular,
easily adaptable hardware, precise semiconductor technology, and a flexible, pre-installed application package that
supports a fields systems. Our comprehensive offering of NXL and NXS variable frequency drives uses the latest
frequency converter technology for more efficient motor operation. These compact, lightweight, reliable drives enable
easy commissioning and start-up, convenient installation.
FEATURES
Integrated AC choke for maximum protection and minimum harmonics
Integral RFI filter for industrial applications
Flexibility in communication with multiple fields options: LonWorks,ModBus, deficient and prefabs
Highly flexible I/O configuration
Multi-application software package pre-installed
Continuous self-supervising runtime and alarm system enhances reliability and safety
Control logic can be powered from an external auxiliary supply, maintaining power to the control panel, internal drive
functions and fieldbuses.
NOTE: Special Order only.

PA404 PRESSURETROL® CONTROLLERS


STEAM PRESSURE CONTROLLERS
Differential (adjustable) 1-5 psi
Order No. Application Oper. Range Switch Action
PA404A1025 Safety control for steam heating boilers; breaks an 3-15psi adj. Breaks at set point on pressure rise;
electrical circuit to shut down burner if steam pressure makes at set point minus
rises above a safe level. differential on pressure fall.
PA404A1033 Safety control for steam heating boilers; breaks an 0.5-9.0psi adj. Makes at setpoint on pressure fall;

4
electrical circuit to shut down burner if steam pressure breaks at setpoint plus differential
rises above a safe level. on pressure rise.
Electrical Ratings: Full load: 8.0A @ 120 Vac., 5.1A @ 240 Vac.

Q298B DAMPER LINKAGE


CONNECTS M833 OR M835 MOTOR TO 1 OR 2 ZONE DAMPERS
Order No. Damper Arms Ball Joints Pushrod
Q298B1065 2 2 1 (24")

Q313 REPLACEMENT THERMOPILE GENERATORS


PROVIDES POWER FOR A MILLIVOLTAGE, SELF-POWERED CONTROL
For use with Q314, Q324, Q327, Q377, Q379, Q382 Pilot Burners
Order No. Open Circuit Output Includes
Q313A1139 600 mV to 750 mV 35" leads
Q313A1170 600 mV to 750 mV 35" leads, PG9 adaptor

Q340A UNIVERSAL 30 MILLIVOLT THERMOCOUPLES


REPLACES MOST 30 mV THERMOCOUPLES
Order No. Lead Length
Q340A1074 24"
Q340A1082 30"
Q340A1090 36"
Q340A1108 48"

132 www.federalcorp.com
______________________________HONEYWELL
Q607 AUXILIARY SWITCHES
FOR CONTROL OF AUXILIARY EQUIPMENT AS A FUNCTION OF MOTOR SHAFT
POSITION
Order No. Switches Applicable Motors
Special Order 1 or 2 Modutrol motors
Models available with adaptor for cover and spring-return motor and mounting
bracket.
Electrical Ratings: Full load: 9.8A @ 120V, 4.9A @ 240V, 2.45A @ 480V

Q5001 VALVE LINKAGE


Connects Modutrol III or Modutrol IV motors to V5011, V5013, V5047 and V5051 valves. Replaces nine of
the older Q601 and Q618 linkages. Overtravel permits tight close-off with less stress on the motor. Linkage
mounts directly on the valve bonnet; motor mounts on linkage bracket. An easy-to-see position indicator tells
at a glance if the valve is open or closed.

Order No. Bonnet Size Stem Force Lift Adjustment


Q5001D1000 1-3/8" 80 or 160 lbs./in. 3/4" fixed
Q5001D1018 1-3/8" 160 or 320 lbs./in. 3/4" fixed
Special Order 1-3/8" 160 or 320 lbs./in. 1-1/2" fixed

Q7000 SERIES INTERFACE MODULES


FOR CONVERTING SERIES 90 MODUTROL IV MOTORS TO SERIES 70 (ELECTRONIC) CONTROL
4
Mount in wiring box of any series 90 Modutrol IV motor (M91XX model numbers). Allows for easy, cost-effective system upgrades. Module
mates to quick-connect terminals and provides screw terminals for field-wiring connections. Solid state circuitry with surface-mount
components. Plastic enclosure provides easy handling and protection for circuitry. Reversing switch for replacing models that rotate
counter-clockwise with an increase in control signal (electrically NC models).
Order No. Application/Description Replaces Replaces Use With
Q7230A1005 Provides adjustable zero and M744S1005, M744S1013, M7284A1004,M7284A1012, M9184D1013, M9185D1004
span, voltage or current M744T1004, M744T1012, M7284C1000, M7284C1018,
control (includes 4-20mA M744Y1009, M744Y1017, M7284Q1009, M7284Q1017,
and 2-10VDC). Adapts M745S1002, M745S1010, M7285A1003, M7285A1011,
M91XX Modutrol IV motors M745T1001, M745T1019, M7285C1009, M7285C1017,
to function as M72XX model M745Y1006, M745Y1014 M7285Q1008, M7285Q1016
for M744S,T,Y; M745S,T,Y
replacements.

R4222, R8222 SWITCHING RELAYS


For use in refrigeration and air conditioning equipment, appliances, vending machines and similar
applications. UL listed.

Coil Voltage (50/60


Order No. Switching Hz.) Pole 1-2-3 Pole 4-5-6
GENERAL PURPOSE RELAYS
R4222B1082 spdt 120V Power None
R4222D1013 spdt 120V Power Power
R8222D1014 dpdt 24V Power Power

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 133


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL______________________________
S443A MANUAL POTENTIOMETERS
RELAYS
Compatable with Modutrol IV motors. Suitable for series 90, M745 and M765 motors controlled by 135 ohms slidewire inputs.
Dpst toggle switch allow selection of automatic or manual control. Surface mounted. Conduit outlet on each side of case.
Screw terminals. Scale marked OPEN-CLOSED.

Order No. Application/Description Resistance Use With


S443A1007 Manual or automatic potentiometer 135 ohm Mod III and Mod IV motors controlled by 135
ohm slidewire inputs
Accessories
30112A potentiometer for S443 135 ohm

S87 SERIES IGNITION CONTROL MODULES


DIRECT SPARK
Solid state, low voltage DSI control modules for use on gas-fired furnaces, boilers and heating appliances. Use with Q347A Spark
Igniter and Q354A Flame Sensor

Lockout
Order No. Application Timing Use With Description
S87D1012 Uses separate electrodes for 11 seconds Q347A Spark Igniter For use with any gas control for direct
spark ignition and flame sensing. and Q354A Flame spark ignition application that is rated at
Includes optional alarm output. Sensor 2.0A or less. Includes optional alarm
For direct replacement of circuit.
S825C,D

4 S8610/S8910 SERIES INTERMITTENT PILOT AND HOT SURFACE MODULES


CONTROL MODULES FOR INTERMITTENT PILOT GAS BURNER IGNITION AND HOT SURFACE
SYSTEMS USED ON CENTRAL HEATING SYSTEMS AND HEATING APPLIANCES
Order No. Replaces Maximum Lockout Time Features
INTERMITTENT IGNITION
S8610U30091, 2 See Footnote 90 seconds 100% pilot shutoff on loss of flame. Includes remote
reset, and automatic vent damper plug. For use in
systems with combination igniter-sensor (single rod
or local sense) or separate igniter and sensor (dual-
rod or remote sense).
HOT SURFACE IGNITION
S8910U1000 See Footnote 3 Hot surface igniton module
1. Replaces most of the following intermittent pilot modules; Honeywell S86, S90, S8600 and S8610; Robertshaw SP715, SP715A,
SP735, SP735L; Johnson GSA, G60, G65, G600, G770.
2. Recommended Combination Gas Control: VR8204, VR8304, VR8345M.
3. Replaces wide range of hot surface modules made by Honeywell, Robertshaw, and White Rogers.

T87F THERMOSTATS-THE ROUND ®


PROVIDES ELECTRONIC TEMPERATURE CONTROL FOR 24Vac RESIDENTIAL HEATING,
COOLING OR HEATING/COOLING SYSTEMS. MERCURY FREE. PREMIER WHITE® COLOR.
Order No. Range Features
T87K1007 40-90oF. Heat only gas or oil systems. Has OFF-HEAT system switching. For one stage heat only.
Heating and Cooling Systems. Has COOL-OFF-HEAT system switching and AUTO-ON Fan
T87N1000 40-90º F. switching. For one stage heat and one stage cooling.

Accessory
129044A
Gold adapter kit includes 6 in. cover ring, adapter ring, screws to cover marks 129044 adapter plate, 127293
of old thermostat. 6" decorator cover plate

134 www.federalcorp.com
______________________________HONEYWELL
T451, T651 3000 SERIES LINE VOLTAGE THERMOSTATS
The T451 provides precision line voltage control of motor-rated electric, gas or oil heating equipment. The T651
provides direct, accurate line voltage control of inductively-rated heating, ventilating, or cooling equipment used
in commercial or industrial environments. Both models feature a vapor-filled dual diaphragm.
Switching Control
Order No. Model No. Action Range Description
SPECIAL ORDER T451A3005 Spst 44-86oF. Makes on temperature fall. Heating only.
T651A3018 T651A3018 Spdt 44-86oF. Heating/cooling thermostat.
ELECTRICAL RATINGS:
50/60 Hz 120V 208V 240V 277V
Full Load 9.8A 5.6A 4.9A 4.2A
Locked Rotor 58.8A 33.6A 29.4A 25.2A
Pilot Duty 125VA
Resistive 22A Non Inductive 19ANI
Heating Only 2.5kW 4.5kW 5kW

T6069 FAN COIL THERMOSTATS


The T6069 thermostats control line voltage valves and/or blower motors on fan coil units
in manual or automatic changeover cooling/heating systems. They feature separate fan
and system manual switches.

System Fan
Order No. Model No. Switches Switches Description
Special order T6069A4010 Heat-Off-Cool Hi-Med-Lo Constant or cycled fan for 2-pipe
system.
Special order T6069B4018 Heat-Off-Cool Hi-Med-Lo Constant fan for 4-pipe system.
Special order T6069C4016 Heat-Off-Cool Hi-Med-Lo Cycled fan for 4-pipe system.
Special order T6069D4014 On-Auto-Off Hi-Med-Lo Constant or cycled fan for 2- pipe
system.
Now available by special order - Digital Line Voltage and Low Voltage Fan Coil Thermostats

4
ELECTRICAL RATINGS: Thermostat and manual switch
120V
T6069 Circuit Load 50/60
Fan Mode A B C D (FLA) Hz
X X X Fan+Cool 8
X X X Fan+Heat 8
Auto
Fan+Res.Heat
X
(N.I.) 8+13
X X X Fan+Cool 8+8
X X X Fan+Heat 8+8
On
Fan+Res.Heat
X
(N.I.) 8+13

T675, T678 CONTROLLERS


REMOTE BULB THERMOSTATS REGULATE TEMPERATURE OF AIR OR LIQUIDS IN DUCTS,
PIPES, TANKS AND BOILERS
Control Capillary Length Max.
Order No. Range and Material Temperature Differential Switching
o
T675A1136 0-100 F. 20' copper 125oF. 1oF. fixed See note 1
T675A1425 55-175 oF. 20' copper 200oF. 3.6-12 oF. Adj. See note 1
T675A1508 0-100 oF. 5' copper 125oF. 3-10 oF. Adj. See note 1
o o o 1
T675A1532 160-260 F. 5' copper 280 F. 3-10 F. Adj. See note
T675A1540 55-175 oF. 5' copper 200oF. 3.6-12 oF. Adj. See note 1
T675A1565 0-100 oF. 20' copper 125oF. 3-10 oF. Adj. See note 1
T678A1437 o
0-100 F. 5' copper 125 F.
o
Each switch fixed at See note
2

o
3 F. Adj. differential
between switches 3-
o
10 F.
Electrical Ratings: Full load 8A @ 120 Vac; 5.1A @ 240 Vac; 4.2A @ 277 Vac
1
Switching spdt switch breakes R-B and makes R-W at set point on temperature rise.
2
Switching: Two spdt switches operating in sequence. Right switch breaks R-B and makes R-W at set point on a
temperature rise. Left switch breaks R-B and makes R-W if temperature continues to rise through interstage differential.

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 135


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL______________________________
T775 ELECTRONIC REMOTE TEMPERATURE CONTROLLERS
FOR HEATING, COOLING OR HEATING/COOLING APPLICATIONS
The T775 electronic stand-alone controllers provide remote sensing of temperature with switched and/or proportional outputs to various
types of loads. They feature an easy-to-use LCD graphical interface, configurable integral and derivative times, and an internal time clock.
A Universal Model can control pressure, humidity, or any medium with an analog input. Reset models feature a simplified setup. Models
with NEMA 4X enclosure are also available.
SPECIFICATIONS
Setpoint Range: -40-248oF
Sensor: Platinum sensor accurate up to 1000 feet from the controller

Analog Outputs
4/20 mA, 0-10 Sensor
Relay Vdc, 2-10 Vdc, Floating Inputs # Sensors
Order No. Description Replaces Outputs & Series 90 Output1 Available Included 2
T775A2009 Standard T775A1001 1 SPDT 1 1
Standard-NEMA
T775B2016 4X 2 SPDT 1 2 1
T775A1009,
T775B2032 Standard T775B1000 2 SPDT 1 2 1
T775A1027,
T775A1035,
T775B2040 Standard T775B1018, 4 SPDT 2 2 1
T775E1015,
T775E1023,
T775M2048 Modulating T775E1056, 2 SPDT 2 2 1
T775J1043,
T775J1050,
T775R2027 Reset Option T775J1068 2SPDT 2 2 2
H775A1006,
H775A1022, 2 (4 or 8
H775A1048, more relays
H775A1063, possible with
H775B1005, T775S2008
Universal- H775C1004, relay
humidity, H775D1003, expansion

4
T775U2006 pressure, etc. H775E1002 2 SPDT 1 or 2 module(s).
Electrical Rating: Voltage input: 24/120/240 Vac, 50/60 Hz
1
One floating output eliminates two relay outputs.
2
50021579-001 included with non-NEMA 4x models and T775SENSWR included with NEMA 4x models.

ACCESSORIES
Order No. Description
50021579-001 Standard platinum indoor sensor, -40 to 350 Fo
T775SENSSTRAP Strap on sensor with wiring enclosure, -40 to 250 Fo
T775SENSWT Water tight sensor with 6' leads, -40 to 270 Fo

T822 THERMOSTATS
For 24 volt heating or cooling applications.
Order No. Application Scale Range Heat Anticipator Positive Off
T822D1032 For low voltage control 55-95 oF. Yes1 Yes
of heating systems
1
Adjustable. 0.18-0.8A @ 30 Vac

T921 PROPORTIONAL THERMOSTATS


LOW VOLTAGE, 3-WIRE CONTROLLER FOR VALVE MOTORS, DAMPER MOTORS, AND BALANCING
RELAYS IN HEATING OR COOLING SYSTEM APPLICATIONS

Accessory
Faceplate Adapter Throttle
for Mounting Range Auxilliary
Order No. Application Range Horizontally (Fixed) Switch Remarks
T921A1191 THERMOSTAT 1 POT o
56-84 F. 135135A 2.5 oF. None Includes slotted sides and an add-
on faceplate to allow thermostat to
be mounted horizontally.

136 www.federalcorp.com
______________________________HONEYWELL
T991 PROPORTIONAL TEMPERATURE CONTROLLERS
FOR MODULATING CONTROL OF WATER OR AIR TEMPERATURE IN DUCTS, TANKS
AND SIMILAR APPLICATIONS

Adjustable
Set Point Throttle Capillary Length Potential
Order No. Range Range & Material Bulb Resistance Includes
o o
T991A1012 0-100 F. 3-30 F. 20' copper 1/2"x4 3/16" 135 ohm _
T991A1061 160-260 oF. 3-30 oF. 5' copper 1/2" x4 3/16" 135 ohm _
T991A1194 55-175 oF. 3.5-36 oF. 20' copper 1/2" x3 9/16" 135 ohm _
T991A1244 o
55-175 F. 3.5-36 F.
o 5' copper 1/2" x3 9/16" 135 ohm 107324A Duct
Bulb Holder

PARTS AND ACCESSORIES FOR REMOTE BULB TEMPERATURE


CONTROLS
Order No. Model No. Application/Description Use With
H107408 107408 4 oz. Heat-conductive compound for coating bulb to improve Temperature controllers with
thermal response of bulb in immersion well. immersion style bulbs

T6031 SERIES REMOTE BULB TEMPERATURE CONTROLS


SPDT SWITCH ACTION
Temp. Capilliary
Order No. Application Thermostat Type Range Differential Length
T6031A1029
T6031C1009
AQUASTAT - 30+90oF
AQUASTAT 40-180 F o
Refrigeration1
Aquastat controller/ambistat 2
-30-90 oF
40-180 Fo
3.5-16 oF adj.
2oF mid-scale
8'
5 1/2'
4
1
SUPER TRADELINE model. Includes bulb holder and mounting plate. Ambient compensated for duct, tank, freezer or cooler.
2
TRADELINE model. Includes 107324A bulb holder. Ambient compensated. High limit. For agricultural and industrial applications.

T6051 SERIES HEAVY DUTY LINE THERMOSTATS


Heavy duty line voltage thermostats are used to control fan coils, fans, motor starters, valves, contactors and circulator motors in
heating and/or cooling systems.

Order No. Application Switching Mounting Differential Range Remarks


T6051A1016 Heating/cooling; with spdt Vertical or horizontal o
1.0 F. 50-80 oF. Standard cover-
resistive rating for electric mounting on standard outlet 135535B
heat applications. box, or on Q651 Subbase.
T6051B1006 Heating/cooling spdt Vertical mounting on o
1.0 F. 46-84 oF. With explosion-
explosion-proof housing. proof housing.

Electrical Ratings--Full load: Heating T6501: 16A @ 120 Vac, 8A @ 240 Vac; Cooling T6051: 8A @ 120 Vac, 4A @ 240 Vac

T6054A SERIES INDUSTRIAL LINE VOLTAGE THERMOSTATS


PROVIDE SPDT HEAVY-DUTY, LINE VOLTAGE TEMPERATURE CONTROL IN
VENTILATION, HEATING OR COOLING SYSTEMS
Order No. Switching Temperature Range Differential System Controlled Dimensions
T6054A1005 Spdt, can be used in 30-100 F. 3.5oF., fixed Heating-cooling 7 1/4" x 2 5/8" x 2"
heating/cooling systems with
external changeover switch.
Electrical Ratings (Amps) 120Vac 240Vac
Full Load 7.4 3.7
Locked Rotor 44.4 22.2
Resistive 10 5

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 137


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL______________________________
V4043 ZONE VALVE
MOTORIZED VALVE, 120/60, CLOSED WHEN DE-ENERGIZED
Order No. Size CV Maximum Close-off Pressure
V4043A1010 1/2" sweat 3.5 20 psi

V5011 SINGLE-SEATED VALVES


For use with Honeywell Actuators and valve linkages. Two-way straight through valve body. Equal percentage flow characteristic for
water and linear flow characteristic for steam. Suitable for two-position and modulating service. Brass body. Stainless steel seat.
Direct acting operation--push down to close

Order No. Old Model No. Body Size (NPT) Cv Pipe Connection Lift Use With
V5011N1040 V5011F1139 1/2" 4.7 Screw 3/4" Water
V5011N1057 V5011F1147 3/4" 7.3 Screw 3/4" Water
V5011N1065 V5011F1154 1" 11.7 Screw 3/4" Water
V5011N1073 V5011F1162 1 1/4" 18.7 Screw 3/4" Water
V5011N1081 V5011F1170 1 1/2" 29.3 Screw 3/4" Water
V5011N1099 V5011F1188 2" 46.8 Screw 3/4" Water
V5011N2055 V5011G1194 3/4" 7.3 Screw 3/4" Steam
V5011N2063 V5011G1202 1" 11.7 Screw 3/4" Steam
V5011N2071 V5011G1210 1 1/4" 18.7 Screw 3/4" Steam
V5011N2089 V5011G1228 1 1/2" 29.3 Screw 3/4" Steam
V5011N2097 V5011G1103 2" 46.8 Screw 3/4" Steam

4
V5013 3-WAY VALVES
For use with Honeywell Actuators and valve linkages. 2 inlets; 1 outlet. Must not be used to divert flow from a common inlet
to 2 outlets.

Order No. Body Size (NPT) Cv Pipe Connection Lift Seat Plug
V5013N1055 3/4" 7.3 Screw 3/4" Brass; integral Brass
V5013N1063 1" 11.7 Screw 3/4" Brass; integral Brass
V5013N1071 1 1/4" 18.7 Screw 3/4" Brass; integral Brass
V5013N1089 1 1/2" 29.3 Screw 3/4" Brass; integral Brass
V5013N1097 2" 46.8 Screw 3/4" Brass; integral Brass

V5011A,C,F &G,V5013 REPACK KITS1


Packing kit contains packing, packing follower, follower spring, and packing lubricant.

Order No. Model No. Use With Valve Size Stem Size
14003294002 14003294-002 V5011C & G; V5011A & V5013 valves with 1 1/4" or less 1/4"
six-sided bonnets; not to exceed 150 psi
14003294004 14003294-004 V5011A & F, V5013A & F 1 1/4" or less 1/4"
14003295002 14003295-002 V5011C & G, 1 1/2" to 3" 3/8"
14003295004 14003295-004 V5011A & F, V5013A & F 1 1/2 to 3" 3/8'
1
Not for use with V5011N and V5013N valves

V5011N & V5013N REPACK KITS


Packing kit contains packing wafers, washer, spring, and o-ring.
Order No. Model No. Use With Valve Size Stem size
Special Order 0901786A V5011N & V5013N 1 1/4" or less 1/4"
Special Order 0901787A V5011N & V5013N 1 1/2" & 2" 3/8"

138 www.federalcorp.com
______________________________HONEYWELL
VR8200A CONTINUOUS PILOT, DUAL AUTOMATIC VALVE, COMBINATION GAS
VALVES
COMBINATION GAS CONTROLS FOR USE IN 24 VAC, GAS-FIRED, STANDING PILOT APPLIANCES
Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment. Meet codes requiring dual safety shutoff.
Compatible with ECO connector.
SPECIFICATIONS
Body pattern: Straight-through with 1/2" inlets and outlets. Pressure rating: 1/2 psi inlet pressure
Pilot gas outlet: Compression fitting for 1/4" OD tubing. Thermostat heat anticipator setting: 0.5A
Pressure tapping: 1/8" NPT with plug.
Inlet/Outlet AGA Certified Pressure Regulator
Order No. Size Capacity 1 Setting Type of Gas Includes
VR8200A2132 1/2" x 1/2" 130cfh 3.5" WC Natural 1/2" x 3/8" reducer bushing; 393690-14 bag
assembly-3/4" straight flange with O-ring, screws and
wrench.
1
Capacity based on 1000 BTU/ cu. Ft., 0.64 sp. gr. natural gas at 1" WC pressure drop

VR8300A CONTINUOUS PILOT, DUAL AUTOMATIC VALVE,


COMBINATION GAS VALVES
FOR USE IN 24 VAC GAS-FIRED HEATING APPLIANCES
Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.
SPECIFICATIONS
Body pattern: Straight-through Thermostat heat anticipator setting: .05A

4
Pilot gas outlet: Compression fitting for 1/4" OD tubing. Pressure rating: 1/2 psi inlet pressure
Pressure tapping: 1/8" NPT with plug.
Order No. Openings Opening Characteristics Capacity 1 Temperature Range
VR8300A3518 1/2" x 3/4" Standard opening 190 cu.ft/hr 0-175oF.
1
Includes one 3/4" x 1/2" reducer bushing; 393690-14 bag assembly--3/4" straight flange with O ring, screws and wrench; 393200
ECO adapter; Q340 (36") thermocouple with adapters; and 393691 Natural LP gas conversion kit.

VR8304A INTERMITTENT PILOT, DUAL AUTOMATIC VALVE, COMBINATION GAS


CONTROLS
Combination gas control for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 30 to 415 cfh. Controls include
safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment. Use with S86F,H; S860D; S8600F,H;
S8610 and S90A,B Control Modules. Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat
ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.

SPECIFICATIONS
Supply voltage: 24 Vac @ 60 Hz Ambient temperature range: 0-175oF.
Wiring connection: 1/4" male quick-connects Pressure rating: 1/2 psi inlet pressure
Pilot gas outlet: Compression fitting for 1/4" OD tubing.
Pressure tapping: 1/8" NPT with plug
Capacity 1
Press. Regulator Press.
Order No. Inlet-Outlet cfh m3/hr Seting Regulator Includes
VR8304M4507 3/4" X 3/4" 300 cfh 8.5 3.5" WC Standard Two 3/4" X 1/2" reducer bushings2, 393691
Natural to LP gas conversion kit.
1
Capacity based on 1000 BTU/ cu. Ft., 0.64 sp. gr. natural gas at 1" WC pressure drop
2
Use of 3/4" x 1/2" reducer bushing reduces capacity to 270 cfh.
Note: Mounting 0-90o in any direction from upright position of gas control knob, including vertically.

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 139


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL_______________________________
VR8345M4302 UNIVERSAL ELECTRONIC IGNITION COMBINATION
GAS CONTROL
Universal electronic iginition combination gas control for use with direct spark ignition, hot surface ignition or intermittent pilot
ignition in 24 Vac, gas-fired appliances, with capacities from 30-415 cfh. VR8345 control replaces the following Honeywell and
competitive combination gas controls for applications requiring a minimum capacity of 30 cfh and a maximum capacity of 415
cfh. Honeywell VR8204A,M; VR8205A,M; VR8304M, VR8305M; White Rodgers 36E01, 36E36 series(standard opening);
Robertshaw 7100DER, 7200DER, 72001DER series.
Capacity, Pressure Type of
Inlet-Outlet A.G.A. Regulator Pressure
Order No. Size(in.) Certified Setting Type of Gas Regulator Includes
VR8345M4302 3/4 x 3/4 300 cfh 3.5" wc Natural or LP Standard Two 3/4" x 1/2" NPT bushings
w/adapter and one 1/2" x 3/8" NPT

VS820 FAMILY COMBINATION GAS CONTROLS


Provide complete control of continuous pilot gas-fired central furnaces and boilers. Easy to install, adjust and service; all
adjustments and connections are accessible from top of control. Complete safety shutoff on pilot flame failure. LITE-RITE (OFF-
PILOT-ON) lightning sequence.

SPECIFICATIONS
Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob.
Body Pattern: Straight-through. Pressure Rating: 1/2 psi inlet pressure
Pressure Tapping: 1/8 in. NPT with plug Pilot gas outlet: Compression fitting for
1/4 in. tubing
Pressure Includes
Inlet-Outlet Regulator Type of Reducer
Order No. Application Description Size Capacity 1 Setting1 Gas Bushings2
VS820A1047 Self-powered Color-coded red to 1/2" X 3/4" 250 cfh 3 1/2" WC Natural One 3/4" X 1/2"
automatic control. identify Powerpile One 1/2" X 3/8"
Use with 750 mV operation. Red pigtail
pilot generator. power unit lead.

4 1.
1,000 BTU/cu.ft., 0.64 specific gravity. Natural gas @ 1" WC pressure differential.

W136A TEST METERS


COMBINATION AC/DC VOLTMETER AND DC MICROAMMETER
USED TO TEST BURNER EQUIPMENT

Sensitivity (ohms/volt)

Order No. 0-300 Vac 0-150 Vdc Used With


W136A10451 20,000 40,000 Flame Safeguard Controls
1
Includes Cable Connector and Two push-on alligator clips.

Y8610U UNIVERSAL RETROFIT INTERMITTENT PILOT GAS


BURNER IGNITION SYSTEMS
FOR CONVERTING CONVENTIONAL STANDING PILOT SYSTEMS TO INTERMITTENT
For use with 24 Vac gas-fired atmospheric furnaces, boiler and heating appliances. Includes: 393691 LP gas conversion
kit; 392431 igniter-sensor assembly. Includes ceramic-insulated kanthal rod that attaches to the existing pilot burner in
place of the thermocouple; 394800-30 ignition cable; 393690-14 flange assembly. Includes 3/4" straight flange with O
ring, 9/64" hex screws and wrench; wiring harness; and reducer bushings for gas control.
SPECIFICATIONS
Voltage and fequency: 24 Vac (nominal) @ 60 Hz Thermostat anticipator setting: 0.7A
Current rating: 0.7A
Contains
Combination Capacity Reducer Temperature
Order No. Control Module Gas Control (BTU/hr 1) Inlet-Outlet Bushings Range Type of Gas
Y8610U6006 S8610U3009 2,3 VR8304M3558 270,000 1/2" x 3/4" Two 3/4" x 1/2" -40 - 175o F Nat. Or LP
1
0.64 sp. Gr. Nat. Gas at 1" WC pressure drop.
2
With 100% pilot gas shutoff and lockout; 90 sec. Max. Timed trial for ignition
3
Includes automatic vent damper plug.

140 www.federalcorp.com
____________HONEYWELL FLAME SAFEGUARD
C437 GAS/AIR PRESSURE SWITCHES
PRESSURE OR DIFFERENTIAL--PRESSURE LIMIT CONTROLS FOR INDUSTRIAL GAS
SYSTEMS
Use C437 for spst switching. Compensate for momentary surges in gas pressure with a restrictive orifice in inlet pressure channel on the
models with pressure range of 1 to 26 in. wc (0.25 to 6.5 kPa). Resume operation by manually resetting when using lockout application
models. Impede tampering and provide dust-resistant operation with enclosed setting. Increase strength of control diaphragm with Buna-
N fiber-reinforced material. Clear glass cover allows observation of interior mechanism to aid in setting and checkout.

Max. Surge Micro- Switch Action Manual Reset (Lockout


Order No. Pressure Range1 Differential2 Pressure Switch (Breaks) on Switch Break) Replaces

C437D2003 1-26" wc 1 3/4" 5.0 psi spst Rise Yes C437D1005


C437D2029 1-10 psi 1 psi 30.0 psi spst Rise Yes C437D1021
C437E2002 1-26" wc 1 1/4" 5.0 psi spst Fall Yes C437E1004

1
Equivalent SI metric units are listed for each pressure range in Honeywell catalog
2
Differential at midscale. Subtractive for C437D,J,G. Additive for C437E,F,H,K. Equivalent SI metric units are listed for
each pressure range in Honeywell catalog.

REPLACEMENT PARTS
Order No. Model No. Description
H106729 106729 GLASS LENS

C6097A, B PRESSURE SWITCHES


C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure.
For use with natural gas, liquid propane(LP) gas, or air. Diaphragm-actuated safety-limit switch. C6097A models break control circuit
at setpoint on pressure fall. C6097B models break control circuit on pressure rise. Removable transparent cover protects scaleplate
4
and adjusting knob.

Reset Differential
Max. Rated
Operating Pressure
Presssure Max. At Min. Max. At Max. Differential (continuous Manual
Order No. Superscedes Connection Range Stpt. Stpt Type psi) Reset
C6097A1004¹ 1/4" NPT .04-5" wc 0.16" wc 0.24" wc Additive 2.9 No
C6097A10121 C645A1030 1/4" NPT 3-21" wc 2.4" wc 4.2" wc Additive 4.3 Yes
C6097A10201 Flange 3-21" wc 2.4" wc 4.2" wc Additive 4.3 Yes
C6097A1053¹ 1/4" NPT 3-21" wc 0.24" wc 0.48" wc Additive 5 No
C6097A1103¹ Flange 1.5-7psi 1.1 psi 1.4 psi Additive 9.3 Yes
C6097A1111¹ 1/4" NPT 1.5-7 psi 1.1 psi 1.4 psi Additive 9.3 Yes
C6097B10282 C645B1013 1/4" NPT 3-21" wc 2.4" wc 4.2" wc Subtractive 4.3 Yes
C6097B10362 Flange 3-21" wc 2.4" wc 4.2" wc Subtractive 4.3 Yes
C6097B1051² 1/4" NPT 1.5-7 psi 1.1 psi 1.4 psi Subtractive 9.3 Yes
1
C6097A breaks a circuit on a pressure fall.
2
C6097B breaks a circuit on a pressure rise.

C7005 FLAME RECTIFIER PILOTS


Combination rectification flame rod and pilot burner for use with suitable relay on industrial or
commercial gas or gas pilot-ignited oil burners.

Order No. Application Ignition Electrode

C7005B1035 For automatic electrically ignited gas applications Yes

REPLACEMENT PARTS
Order No. Description
101738B Flame rod assembly

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 141


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL FLAME SAFEGUARD___________
C7007 FLAME ROD HOLDERS
Used to apply flame rod in gas-fired system controlled by recitification type flame
safeguard control. Use with pressurized fire boxes. Hold flame rods firmly over
the pilot or burner with a chuck and setscrew arrangement.

Order No. Description Mounting


C7007A1001 FLAME ROD HOLDER 1/2" male NPT

C7008 FLAME ROD AND HOLDER


Miniature "spark plug" type flame rod holder with threaded
base, snap-on cover and Kanthal A-1 Flame Rod. Use only with
gas. Installs with or without cover. Use with Honeywell Flame
Safeguard controls requiring rectification-type flame detection.

Order No. Description


C7008A1174 12" Flame Rod

TM
C7012 PURPLE PEEPER ULTRAVIOLET FLAME DETECTORS
Solid state electronic flame detectors for use with appropriate Honeywell relays and amplifiers. Sense ultraviolet radiation produced by
combustion of gas, oil, coal or other fuels.

Voltage (50/60 Pipe Mounting


Order No. Application/Description Hz) Size Housing
C7012A1145 Use with Honeywell rectification-type flame safeguard controls 120 VAC 3/4" NPT Violet, cast-
EXCEPT Dynamic Self Check models 1. Field-replacable viewing aluminum cover 2
window and ultraviolet sensing tube.

4 C7012E1104 Use with only Dynamic Self Check flame safeguard


controls 1.Field-replaceable viewing window and ultraviolet
sensing tube, self-checking coil and shutter.
120 VAC 3/4" NPT Violet, cast-
aluminum cover 2

C7012E1112 Use with only Dynamic Self Check flame safeguard 120 VAC 1" NPT Violet, cast-
controls 1.Field-replaceable viewing window and ultraviolet aluminum cover 2
sensing tube, self-checking coil and shutter.
1
Dynamic Self Check models are R4138A/B,R4181A, R4126/R4127 with R7256B, R4150 with R7253B, and R4057C/D/E,
R4138C/D, or R4140 with R7247C amplifier.
2
Mounting flange (with heat block) and faceplate are separate to provide heat insulation and seal-off. Meets NEMA 4 standards.

ACCESSORIES
Order No. Description
H113228 Ultraviolet sensing tube for solid state models.

C7027A MINIPEEPER ULTRAVIOLET FLAME DETECTORS


COMPACT FLAME DETECTOR FOR USE WITH FLAME SAFEGUARD CONTROLS WITH
ULTRAVIOLET AMPLIFIERS.
Use on Honeywell Flame Safeguard primary safety controls and burners requiring ultraviolet flame detection.

Order No. Ambient Temp. Range Lead Length


C7027A1023 0-215oF. 8'
C7027A1031 -40-215oF. 8'
C7027A10491 0-215oF. 8'
1
C7027A1072 40-215oF. 8'
C7027A10802 0-215oF. 8'
1
1/2" NPT threaded spud connector
2
Includes 136733 Heat Block and 390427B Bushing , 1/2" x 3/8" to replace Fireye UV2 sensor when replacing a
complete Fireye to Honeywell system.

ACCESSORIES
Order No. Model No. Description
H136733 136733 Heat Block 1/2" male by female thread

142 www.federalcorp.com
___________HONEYWELL FLAME SAFEGUARD
C7035A MINIPEEPER ULTRAVIOLET FLAME DETECTORS
Compact flame detector for use with flame safeguard controls with ultraviolet amplifiers. Mounts on a 1 in. sighting pipe by
using an integral collar. Protects the sensing tube with a shield.Meets outdoor raintight requirements of Underwriters
Laboratories Inc., NEMA 3 and NEMA 4. Wires in parallel for difficult sighting applications.Seals against pressures as high as
5 psi (34.5 kPa) when correctly installed. Field-replaceable ultraviolet sensing tube.
Order No. Ambient Temp. Range Lead Length
o
C7035A1023 0-250 F. 6'
C7035A1031 40-250oF. 6'

REPLACEMENT PARTS

Order No. Temp. Range Description


129464M 0-250oF Ultraviolet sensing tube.
129464N -40-250°F Ultraviolet sensing tube.

C7061 DYNAMIC SELF-CHECK ULTRAVIOLET FLAME DETECTOR


Dynamic self-checking flame detector used with R7861 Dynamic Self-check Amplifiers for sensing the ultraviolet radiation
generated by the combustion of gas, oil, or other fuels.
Order No. Description
C7061A1012 Housing meets NEMA 4 enclosure standards. Oscillating shutter interrupts
ultraviolet radiation reaching UV sensor 12 times per minute to provide the UV
sensor tube checking function.

4
C7915A INFRARED(LEAD SULFIDE
PHOTOCELL) FLAME DETECTOR
Used for combination or dual-fuel applications. Mounts easily on a standard 3/4"
sight pipe. Works where flame rod or rectifying photocell mounts are difficult to
apply. Includes lead sulfide cell 32007255-001, bushing with magnifying lens,
orifice plate 1051342 heat block 1050613 and reducer bushing 390427A 4.

Order No. Use With Lead Length1


C7915A1028 R7852 48"
1
Models with 30" and 96" Lead Lengths available by Special Order.
2
With 0.125" diameter hexagonal orifice to reduce the detector field of view.
3
To insulate the detector from sight pipe temperatures higher than -40ºF - 125ºF and
up to 250ºF.
4
To mount the detector on a 1/2" sight pipe, specifically to replace Fireye™ lead
sulfide infrared flame detectors.

C7927A SOLID STATE ULTRAVIOLET FLAME DETECTORS


The Solid State Ultraviolet Flame Detector detect the ultraviolet radiation emmited by combustion flames.The flame
detectors are used with 7800 SERIES flame safeguard controls with R7851B amplifiers. Mounts on a 1/2 in. sighting
pipe by using an integral collar. Seals against pressures as high as 5 psi (34.5 kPa) when correctly installed.

Order No. Ambient Temp. Range Lead Length


C7927A1016¹ 40-200oF. 96"
¹ Use with R7851B Amplifier

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 143


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL FLAME SAFEGUARD___________
CR7890B INTEGRATED BURNER CONTROL
The Honeywell CR7890B integrated burner control is a micro-processor-based control for automatically
fired gas, oil, or combination fuel single burner applications. The CR7890B control consists of a self
contained relay module, amplifier and a shutter type solid state ultraviolet detector for sensing the
ultraviolet radiation generated by the combustion of gas, oil, or other fuels. Options include the S7800
keyboard display module (KDM), for use during burner setup or troubleshooting.
Functions the CR7890B provides include automatic burner sequencing, flame supervision, system status
indication, system or self-diagnostics and troubleshooting.
Features
Oscillating shutter interrupts ultraviolet radiation reaching the UV sensor to provide the UV sensor
checking function. Amplifier circuitry components are checked from the microprocessor in the CR7890B
Device can be mounted horizontally, vertically or at any other angle. The device has faceplate alignment
and integral locating reference points to assure proper shutter mechanism operation.
Quartz viewing window is field replaceable.
CR7890B1019 uses Brad Harrison® 3R9006A20A120 connector.
A swivel mount is available to facilitate flame sighting.
-40ºF (-40ºC) rated ultraviolet sensing tube.
High pressure 50 psi (345 kPa) quartz viewing window, magnifying lens and anti-vibration mount are
available as accessories.
Housing meets NEMA 4 enclosure standards (NEMA 1 when access cover s used).
Protective heat block built into mounting flange.
Power LED blinks a fault code when device is in ALARM.
Optional keyboard display module (KDM) provides additional troubleshooting and diagnostic information.
Item No. Description
CR7890B1019 Integrated Burner Control
Special Order

L91 PROPORTIONAL PRESSURETROL CONTROLLERS


MODULATING PRESSURE-OPERATED HIGH LIMIT CONTROL FOR STEAM SYSTEMS

4
Modulating pressure operating control for regulation of liquid or air and other non-corrosive gases. Use with steam, air,
noncombustible gases, or other fluids non-corrosive to the brass or phos-bronze (300 psi models) bellows. Do NOT use with
combustible mediums or any medium chemically harmful to phos-bronze bellows (10-300 psi models)

Control Range Max. Surge Pressure Differential at Midscale Number


Potentio- Main Setting
Order No. psi kPa psi kPa psi kPa adj. meters Means
L91B10351 0-15 0-103 20 138 1-12 7-83 Yes 1 Screw adj. top
L91B10502 5-150 34-1034 225 1151 5-23 34-159 Yes 1 of case
1
Pipe connection: 1/4 NPT, male fitting (requires standard pipe coupling to mount on siphon loop).
2
Pipe connection: 1/4 NPT female fitting (can be mounted directly on siphon loop).

®
L404A-D,F; L604 PRESSURETROL CONTROLLERS
Provide operating control, automatic or manual reset limit protection for pressure systems up to 300 psi. Use with steam, air,
noncombustible gases, or other fluids noncorrosive to pressure sensing element. Adjustments are made by screws on top of the
case. Mount using 1/4" NPT female threads or surface mount through base of case. Models are mercury free, automatic reset and
have stainless steel diaphragms.

Maximum
Operating Range Subtractive diaphragm Includes Switch
Order No. in psi Differential in psi 1 pressure in psi Siphon Loop Type Switch Action 3

L404F1060 2-15 2 to 6 25 Yes spdt R-W makes R-B breaks

L404F1078 5-50 6 to 14 85 Yes spdt R-W makes R-B breaks

L404F1102 10-150 10 to 22 225 - spdt R-W makes R-B breaks

R-W makes R-B breaks


L604A1169 2-15 2 to 6 Yes spdt
1
Differential at midscale
3
On pressure rise

144 www.federalcorp.com
___________HONEYWELL FLAME SAFEGUARD
L4079 PRESSURETROL® LIMIT CONTROL - MANUAL RESET
HIGH PRESSURE LIMIT SWITCHES
High pressure limit switches which break electrical circuits when pressure rises
to a preset value.Used with steam, air, noncombustible gases, and fluids
noncorrosive to the sensing element.
Sensor Element: Stainless Steel diaphragm
Siphon Loop Included
Switch Contact Ratings:
120 Vac: 9.8 AFL, 58.8 ALR
240 Vac: 4.9 AFL, 29.4 ALR

Maximum
Operating Pressure Sustained
Order Number Range Operating Pressure Switching Action
14-103 SPDT break on
L4079B1033 2 - 15 psi kPa 25 psi 172 kPa pressure rise
70-1035 SPDT break on
L4079B1041 10 -150 psi kPa 225 psi 1550 kPa pressure rise

Q179A FLAME RECTIFIER GAS PILOTS


Combination rectifying flame rod and pilot burner for use with suitable electronic relay on industrial or
commercial gas burners or gas pilot-ignited oil burners.
Order No. Application Electrode Tip Style
Q179A1050 For intermittent or interrupted ignition. Has both flame Flame and ignition T
electrode and ignition electrode.
For intermittent or interrupted ignition. Has both flame
Q179A1126 electrode and ignition electrode. Flame and ignition I

PARTS AND ACCESSORIES FOR Q179A

4
Order No. Application/Description Tip Style
133451A Flame rod and insulator assembly T

Q179C MINIATURE RECTIFICATION PILOTS


Gas pilot burner assemblies prove pilot flame on industrial or commerical gas burners or gas pilot-ignited oil burners.
Order No. Application Mounting Target Mount
Q179C1009 Combination pilot burner and rectifying flame rod flame detector. With End Dual wing-rear
ignition electrode; suitable for use on interrupted or intermittent
electrically ignited gas pilot applications. Use with Q624 or other suitable
ignition transformer.

Q314 PILOT BURNERS


NONPRIMARY-AERATED, INSERT ORIFICE-TYPE PILOT BURNERS
Mounting
Order No. Type of Gas Bracket1 Includes
Q314A4586 Natural, LP B Natural gas orifice; LP gas orifice; 1/4" cc inlet fitting; special
mounting bracket with screws for converting 'B' bracket to 'A'.

1
See diagrams in Honeywell catalog.

Q345A IGNITER-SENSORS
NONPRIMARY-AERATED COMBINATION PILOT BURNER AND IGNITER
Used with the S86 in intermittent pilot systems
Mounting
Order No. Tip Style Type of Gas Bracket Includes
Q345A1305 Sprays Straight Natural B 1/4" cc inlet fitting

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 145


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL FLAME SAFEGUARD___________

Q624 SOLID STATE IGNITION TRANSFORMERS


IGNITE PILOTS ON COMMERCIAL OR INDUSTRIAL GAS BURNERS
Maximum Primary rating (@
Order No. Application Voltage (60 Hz) Output Voltage 120 Vac)
Q624A10141 Can be used to replace single electrode ignition 120 Vac 15,000V Peak 66 VA
transformers in interrupted gas or pilot
applications. Prevents detection of ignition spark
when properly applied in flame detection system
with C7027 or C7035 Ultraviolet Flame Detector.
Mounting plate designed to replace standard
ignition transformers.

1
With threaded terminal nut high voltage electrode.

R4795 PRIMARY CONTROLS


PROVIDE SOLID STATE, ELECTRONIC, FLAME SAFEGUARD PROTECTION FOR COMMERCIAL
AND INDUSTRIAL SINGLE OR DUAL FUEL BURNERS WITH PRE-IGNITION PURGE OF
COMBUSTION CHAMBER.

Requried Components (Ordered Separately)


Alarm
Voltage Contacts
Order No. (50/60 Hz) (spdt) Mounting Base Plug-in Amplifier1 Plug-in Purge Timer
R4795A1016 120Vac Yes Q270A1024 permits 1 or 2 ST71A1000, 7 seconds

4
recessed or surface ST71A1042, 10 seconds
mounting. ST71A1018, 30 seconds
ST71A1026, 60 seconds
ST71A1034, 90 seconds
1
A number is listed for each amplifier in table below. These numbers correspond to those listed under "Plug-in Amplifier" in ordering.

ACCESSORIES FOR R4795


Number (see Flame Failure
Order No. ordering table) Type Response Time Use With
R7289A1004 1 Rectification(green) 3.0 seconds Rectifying photocell, flame rod or
C7012A,C Purple Peeper Ultraviolet Flame
Dectector.
R7290A1001 2 Ultraviolet(purple) 3.0 seconds Use with C7027A, C7035A or C7044A
Minipeeper Ultraviolet Flame Detector

RA890 SERIES PROTECTORELAY PRIMARY CONTROLS


Nonprogramming primary control provides solid state, electronic, flame safe-guard protection for industrial and
commercial single or dual fuel burners. With isolated spdt alarm terminals. NOTE: Honeywell recommends upgrade
to RM7890 Series.

Order No. Voltage Safety Switch Timing Flame Failure Response Time1
2
RA890F SERIES , ALARM
RA890F1288 120V @ 50/60 Hz 15 seconds 3.0 seconds
RA890F1346 120V @ 50/60 Hz 30 seconds 3.0 seconds
RA890G SERIES 3
RA890G1260 120V @ 50/60 Hz 15 seconds 3.0 seconds
1
3 second response is recommended for nonrecycling ignition cutoff service
2
For use with flame rods, rectifying photocells and C7012A,C Purple Peeper Ultraviolet Flame Detectors
3
Used for interrupted ignition with intermittent pilot on gas burners; interrupted or intermittent ignition on oil burners.
Uses C7027, C7035 or C7044 Minipeeper Ultraviolet Flame Detector for flame sensing.
Note: For new installations, also specify Q270A1024 base

146 www.federalcorp.com
____________HONEYWELL FLAME SAFEGUARD
V48, V88 DIAPHRAGM GAS VALVES
SOLENOID-OPERATED DIAPHRAGM VALVES FOR CONTROLLING FUEL GASES
Valve Capacities 1
Order No. Size cfh m3/hr Voltage Pressure
V48A2151 3/4" 668 18.9 120V @ 50/60 Hz 1/2 psi
V48A2169 1" 1,021 28.9 120V @ 50/60 Hz 1/2 psi
V48A2177 1 1/4" 2,100 59.5 120V @ 50/60 Hz 1/2 psi
V48A2185 1 1/2" 2,400 67.9 120V @ 50/60 Hz 1/2 psi
V48A2243 2" 4,178 118.3 120V @ 50/60 Hz 1 psi
V88A1618 1" 1,021 28.9 24V @ 60 Hz 1/2 psi
V88A1626 1 1/4" 2,100 59.5 24V @ 60 Hz 1/2 psi
V88A1634 1 1/2" 2,400 67.9 24V @ 60 Hz 1/2 psi
V88A1709 2" 4,178 118.3 24V @ 60 Hz 1 psi
1
cfh Natural gas 1,000 BTU/cu.ft., 0.64 specific gravity, p.d. 1" WC (m3/hr Natural gas 37.3 MJ/m3, 0.64 specific
gravity, p.d. 0.25 kPa).

REPLACEMENT PARTS
Order No. Model No. Description Voltage
H116930 116930 Replacement coil for V88A 24V @ 60 Hz
H116931 116931 Replacement coil for V48A 120V @ 60 Hz
ACCESSORIES
H126590 126590 Adjustable bleed valve assembly -
for opening speed control

V4055 FLUID POWER GAS VALVE ACTUATORS 4


Control gas supply for commercial and industrial burners. Valve opens when power is applied. Use with V5055 valve. Valve
and actuator can be mounted in any direction.
Voltage (60
Order No. Description Hz)1 Opening Time1 Includes
2
ON-OFF FLUID POWER GAS VALVE ACTUATORS
V4055A1064 ON-OFF actuator.Normally used with V5055A,B 120Vac 26 seconds Damper shaft.
valve bodies. Low Pressure.
V4055A1098 ON-OFF actuator.Normally used with V5055A,B 120Vac 13 seconds Damper shaft.
valve bodies. Low Pressure.
V4055A1304 ON-OFF actuator.Normally used with V5055A,B 120Vac 26 seconds Damper shaft and return
valve bodies. Low Pressure. spring intstalled.
V4055D1019 ON-OFF actuator.Normally used with V5055C 120Vac 13 seconds Damper shaft.
valve bodies. Low Pressure.3

MANUAL RESET SAFETY SHUT-OFF GAS VALVE ACTUATORS (MANUAL OPENING, ELECTRIC HOLDING): 4
V4055G1004 Manually reset safety shutoff valve 120Vac 13 seconds Damper shaft.
1
Can also be used at 50 Hz; however, opening time will increase by 20%.
2
Rated for final safety shutoff service when used with V5055 valve. Indicators on valve and actuator provide constant visual
indication of valve position.
3
Includes Factory Mutual "Proof of Closure" and UL "Valve Seal Overtravel Interlock" switch. Meets Factory Mutual and UL
requirements when used with V5055C valve bodies.
4
Provides manual reset, safety shut-off function as required on FM, IHEA-IRI and NFPA 86A,B,C industrial furnaces, ovens,
and kilns. Mounts on V5055 valve. Indicator on valve and actuator provides visual indication of valve position.

ACCESSORIES
Order No. Application/Description
H133569 Proof of closure switch
7616BR Crank arm assembly for motor w/o tap

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 147


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL FLAME SAFEGUARD___________
V4062A, OFF-LO-HI FLUID POWER GAS VALVE ACTUATORS
Control gas supply for commercial and industrial burners. Valve opens to low fire position when power is applied; valve
opens all the way on demand.
Order No. Application/Description Opening Time Includes
V4062A1008 HI-LO-OFF actuator.1 Low pressure. 26 seconds Damper shaft
1
Actuator can be used with all V5055 bodies; best control and low fire repeatability will result with V5055B with
characterized guide.

ACCESSORIES
Order No. Description
H133569 Valve closed switch indication bag assembly (must be used with V5055C or E).
7616BR Damper Crank Arm (damper arm and clip.)

V5055 INDUSTRIAL GAS VALVES


SAFETY SHUTOFF VALVES USED WITH V4055, V4062 AND V9055 FLUID POWER
ACTUATORS TO CONTROL GAS FLOW TO COMMERCIAL AND INDUSTRIAL BURNERS
Valve Capacities
Order No. Application Size cfh m3/hr
Special Order Low pressure characterized guide (provides slowly increasing gas 1" 960 27.2
flow on opening).
V5055B1010 Low pressure characterized guide (provides slowly increasing gas 1 1/4" 1406 39.8
flow on opening).
V5055B1028 Low pressure characterized guide (provides slowly increasing gas 1 1/2" 1717 48.6
flow on opening).
V5055B1069 Low pressure characterized guide (provides slowly increasing gas 2" 3620 102.5

4 flow on opening).
V5055B1077 Low pressure characterized guide (provides slowly increasing gas
flow on opening).
2 1/2" 4250 120.3

V5055B1085 Low pressure characterized guide (provides slowly increasing gas 3" 5230 148
flow on opening).
V5055C1000 Low pressure. Double seat (use with actuators having valve seal 2" 3620 102.3
overtravel interlock).
V5055C1018 Low pressure. Double seat (use with actuators having valve seal 2 1/2" 4250 120.3
overtravel interlock).
V5055C1026 Low pressure. Double seat (use with actuators having valve seal 3" 5230 148.3
overtravel interlock).

VALVE-ACTUATOR PRESSURE RATINGS


Actuator
V4055A,D1 V4055B,E 1 V4062, V90551
Valve Sizes Diff.2 Close-Off3 Diff.2 Close-Off3 Diff.2 Close-Off3
V5055A,C 3/4" - 3" 5 psi 15 psi 15 psi 15 psi 5 psi 15 psi
V5055A,C 4" 3 psi 15 psi 5 psi 15 psi 3 psi 15 psi
V5055B 3/4" - 3" 5 psi 15 psi 15 psi 15 psi 5 psi 15 psi
V5055B 4" 3 psi 15 psi 5 psi 15 psi 3 psi 15 psi
V5055D,E 3/4",1", 1 1/4", 1 1/2" 5 psi 75 psi 25 psi 75 psi 5 psi 75 psi
V5055D,E 2", 2 1/2", 3" 5 psi 45 psi 15 psi 45 psi 5 psi 45 psi
1
Use a V4055D, V4055E, V4026D, or V9055D (with valve-closed indication switch) with a V5055C or E ( with
double seal) for a Valve Seal Overtravel Interlock.
2
Maximum operating pressure differential.
3
Maximum close-off pressure without leakage. This is the maximum allowable pressure drop to which a valve may
be subjected while fully closed and is independent of the valve body ratings.

148 www.federalcorp.com
___________HONEYWELL FLAME SAFEGUARD
V8944 DIAPHRAGM GAS VALVES
DUAL STAGE PRESSURE REGULATION
Solenoid-operated diaphragm valves that combine the functions of safety shutoff and pressure regulation in a single unit.
Suitable for use on atmospheric boilers, commercial water heaters, and rooftop heaters. Valve body of die-cast aluminum
with a straight-through pattern.
Regulator Set Point1
Current (Max.
Amps at rated
Order No. Valve Type Gas Size Voltage Vac/Hz) Low Fire High Fire Replaces
V8944B1027 Two-stage, slow opening Natural 1 1/4" 24V, 50/60 Hz 0.5 0.8" WC 3.5" WC V8844B1028
1
Regulator setpoints adjustable for natural gas-Low Fire, 0.8-2" WC; High Fire, 3-4.5" WC.

V9055A MODULATING FLUID POWER GAS VALVE ACUTATORS


Control gas supply for commercial and industrial burners. Valve opens to low fire position when power is applied, then
modulates to meet firing rate controller demand.
Order No. Description Voltage (60 Hz)1 Includes
2
V9055A1055 Modulating-OFF actuator for use with V5055B valve 120Vac Damper shaft
bodies. Low pressure.
1
Can also be used at 50 Hz; however, opening time (26 seconds) will increase by 20.
2
Actuator can be used with all V5055 valve bodies; however, best control and low fire capability will result with V5055B with
characterized guide.

INTEGRATED GAS TRAIN


Build your Gas train with only an adjustable wrench!
Your custom gas train consists of one or more of the following components:
V5097, V4297A, V4297S and C6097A, B

V5097 INDUSTRIAL GAS VALVES


Safety shutoff valves used with V4055, V4062 and V9055 fluid power actuators to control gas flow to commercial and
industrial burners. Use with natural or LP gases. Mount directly in gas supply line. Seven pipe adapter sizes from 3/4" to 3" have
NPT or BSP threaded connections. Provides three 1/4" upstream and two 1/4" downstream tap and plug. Yellow SHUT indicator
attached to the valve stem provides an indication of the valve closed position. Order pipe adapters separately..

Valve Capacities 1
Order No. Application Pipe Adapter cfh m2/hr
V5097B1002 Low pressure characterized guide (provides slowly 32000109-001 - 3/4" NPT 665 18.8
increasing gas flow on opening). 32000109-002 - 1" NPT 960 27.2
32000109-003 - 1 1/4" NPT 1406 39.8
32000109-004 - 1 1/2" NPT 1717 48.6 56.9
32000109-005 - 2" NPT 1990
V5097B1010 Low pressure characterized guide (provides slowly 32001605-001 - 2" NPT 3620 102.5
increasing gas flow on opening). 32001605-002 - 2 1/2" NPT 4250 120.3
32001605-003 - 3" NPT 5230 148.0
V5097C1018 Low pressure, double seat (use with actuators having 32001605-001 - 2" NPT 3620 102.5
valve seal overtravel interlock). 32001605-002 - 2 1/2" NPT 4250 120.3
32001605-003 - 3" NPT 5230 148.0
1
Based on 0.64 specific gravity natural gas at 1" WC pressure drop.

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 149


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL FLAME SAFEGUARD____________

V4297A SOLENOID SAFETY SHUT-OFF VALVE


Controls gas flow to commercial and industrial burners. The valve is part of the Honeywell Integrated Valve Train system that
allows gas train components to be directly bolted together.
Used with natural or LP gases. V4297A normally closed valves are rated for final shutoff service. One valve body applicable
to five pipe sizes: 3/4", 1", 1 1/4", 1 1/2", and 2" pipes. Accepts C6097 Pressure Switch mounted directly to flange
(upstream pressure tap only). V4297A models will mate only with smaller V5097 or V4297S valve bodies.
Order No. Description Pipe Diameter(in.) Capacity 1(cfh)
V4297A1005 Solenoid Safety Shutoff Valve, small flow, 3/4" 650
110/120Vac, 50/60 Hz, 5 psi 1" 700
1 1/4" 780
V4297A1013 Solenoid Safety Shutoff Valve, large flow, 3/4" 1190
110/120Vac, 50/60 Hz, 5 psi 1" 1460
1 1/4" 2260
1 1/2" 2735
2" 3060
1
Ratings are 1" pressure drop for gas with 0.64 sp.gr.

V4297S NORMALLY OPEN VENT VALVES


Provides the vent function in a double block and bleed configuration. The valve is part of the Honeywell
Integrated Valve Train System, which allows gas train components to be directly bolted together.
*Used with natural or LP gas.
*V4297S valves are normally open valves to be used as vent valves in double block and bleed configurations.
The gas flows through the vent connection when the valve is not energized.
*V4297S valves are used with 110/120 Vac, 50/60 Hz controllers
*V4297S is not gas flow direction dependent. It can be connected either way in the valve train.

4
Order No. Description Capacity 1(cfh)
V4297S1003 Solenoid Normally Open Vent Valve Small Body, 1" Vent 714
Connection. 110/120 Vac, 50/60 Hz, 5 psi.
V4297S1011 Solenoid Normally Open Vent Valve Large Body, 1 1/4" Vent 1115
Connection. 110/120 Vac, 50/60 Hz, 5 psi
1
Based on 1" pressure drop for gas with 0.64 sp. gr.

7800 SERIES CROSS REFERENCE


The 7800 Series family replaces every Honeywell Flame Safeguard control made before 1992--both the electro-
mechancial and basic micro-processor. All 7800 Series products use the same wiring subbase (Q7800) and
share the same flame amplifiers and prepurge timers. Optional accessories include S7830 first-out expanded
annunciator, S7810 data controlbus module, S7820 remote reset module, QS7800A communications interface
with P.C.,ZM7850A software and Q7700A communications base unit.

7800 Prepurge
Old Electro-
Old Model Description Replacement1 Timer Amplifier2
Mechanical
Technology PRIMARIES
R7023 Flame relay RM7823 N/A
RA890 Protecto relay, primary control RM7890 N/A
R4795 Primary plus pre-purge RM7895 ST7800
R7795 Solid state primary, plus prepurge RM7895 ST7800
R485 Semi-automatic primary RM7885 N/A Use R7800 Series
R4075 Semi-automatic primary RM7885 N/A rectification, infra-red, or
R4138 Semi-automatic primary RM7838 ST7800 ultra-violet amplifiers.

PROGRAMMERS
R4140 Full programmer with mechanical cam RM7840 ST7800
BC7000 Basic microprocessor programmer RM7800 ST7800
1
S7800 keyboard display standard on RM7800, optional (recommended) for all other models.
New Micro 2
Flame sensor must match amplifier.
Processor
Technology

See TechTip 55 for Enhanced 7800 Cross-Reference

150 www.federalcorp.com
____________HONEYWELL FLAME SAFEGUARD
RM7800G PROGRAMMER
Microprocessor-based integrated burner control for automatically fired gas, oil, coal or combination fuel single burner applications. Provides
safety, functional capability and features beyond conventional controls. Functions include automatic burner sequencing, flame supervision,
system status indication, system or self-diagnostics and trouble shooting. Five LEDs provide sequence information. Five function Run/Test
Switch. Local or remote annunciation of operation and fault information (optional). Non-volatile memory retains history files and lockout status
after loss of power. With Valve Proving Feature. RM7800L comes standard with enhanced S7800A1142 Keyboard Display.

Pilot Flame Establishing Main Flame Establishing


Order No. Application/Description Period (PFEP) Period (MFEP)1 Postpurge2 Replaces
Automatic programming RM7800L1012
RM7800L1087 control with display, 120/60 4 or 10 seconds 10 or 15 seconds 15 seconds BC7000L+PM720L
1
The MFEP will be determined by terminals used, configuration jumper or jumper wire addition. See instruction sheet.
2
Pre-purge will be determined by which ST7800A Purge Time Card is selected.
Note: Required Components: Q7800 Universal Wiring Subbase, R7847, R7848, R7849, R7886 Flame Safeguard Amplifiers, S7800
Keyboard Module, and ST 7800 Plug-in Purge Timer Cards.

RM7823A PRIMARY FLAME SWITCH


Microprocessor-based integrated flame switch for detecting a flame using rectification, ultraviolet (UV) or infrared (IR) source.
Provides level of safety, functional capability and features beyond conventional controls. Can be fitted with any 7800 Series
Amplifier to provide relay action from two single pole, double throw (spdt) relays when flame is present or not present. RM7823A
is a flame detector relay only. Suitable primary control must be used to provide safe-start check, safety lockout, load switching and
other functions required in flame safeguard systems. Three LEDs to indicate power, flame and alarm. Non-volatile memory.
Shutter drive output.
Order No. Voltage Switching Replaces1
RM7823A1016
1
120Vac @ 60Hz Two spdt R7023B,C
To replace R7023B, select R7847 Flame Signal Amplifier. To replace R7023C, select R7849 Flame Signal Amplifier. Suggested
option--S7800 Keyboard Display.
4

RM7838B SEMI-AUTOMATIC PROGRAMMER


Microprocessor-based integrated burner control for industrial semi-automatically fired gas, oil, coal or combination fuel single
burner applications. Provides level of safety, functional capability and features beyond conventional controls. Functions include
purge, burner pilot startup, flame supervision, system status indication, system or self diagnosis and troubleshooting. Delays
admission of fuel to combustion chamber until pilot flame has been proven and then monitors the flame through the run period
while providing system status indication. Includes Keyboard Display Module. Five LEDs provide sequence information. Non-
volatile memory retains history files and lockout status after loss of power. Selectable pilot flame establishing period. Provides
application flexibility and optional communication interface capability. Includes Valve Proving Feature and Programmable Post
Purge.

Pilot Flame
Establishing Period
Order No. Description (PFEP) Replaces
RM7838B1021 Semi-automatic industrial primary relay module with S7800 4 or 10 seconds R4138A , C
display, 120/60 RM7838A
Note: Required components: Q7800 Universal Wiring Subbase, R7800 Series Flame Signal Amplifiers, and ST7800 Plug-in
Purge Timer Card.

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 151


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL FLAME SAFEGUARD___________
RM7840G, L, M PROGRAMMER
Microprocessor-based integrated burner control for automatically fired gas, oil, coal or combination fuel single burner applications.
Provides safety, functional capability and features beyond conventional controls. Functions include automatic burner sequencing,
flame supervision, system status indication, system or self-diagnostics and troubleshooting. Five LEDs provide sequence
information. Five function Run/Test Switch. Local or remote annunciation of RM7840 operation and fault information. Non-
volatile memory retains history files and lockout status after loss of power.

Pilot Flame Main Flame


Establishing Establishing Period
Order No. Application/Description Period (PFEP) (MFEP) 1 Postpurge2 Replaces
RM7840G1022³ Relay module without display, 120/60 4 or 10 seconds 10, 15, 30 seconds Selectable R4140G
or Intermittment.

RM7840L1075³ Relay module without display, 120/60. 4 or 10 seconds 10 or 15 seconds Selectable R4140L
Interrupted Pilot.
RM7840L1026 Relay module without display, 120/60. 4 or 10 seconds 10 or 15 seconds 15 seconds R4140L
Interrupted Pilot.

RM7840M1017 Relay module without display, 120/60 4 or 10 seconds 10 seconds 15 seconds R4140M

1
The MFEP will be determined by terminal used, configuration jumper or jumper wire addition. See instruction sheet.
2
Pre-purge is determined by ST7800 Plug-in Timer Card selected. Selectable Postpurge using S7800A1142.
³ With Valve Proving Feature.

Note: Required Components: Q7800 Universal Wiring Subbase, R7847, R7848, R7849, R7886 Flame Signal Amplifiers, and ST
7800 Plug-in Purge Timer Cards. If Keyboard display ST7800 is recommended (order separately) or order equivalent RM7800
(included).

RM7885 SEMI-AUTOMATIC PRIMARY CONTROL

4 Microprocessor-based integrated burner control for industrial semi-automatically fired gas, oil, coal, or combination fuel single
burner applications. Provides level of safety, functional capability and features beyond conventional controls.
FEATURES
Functions include flame supervision, system indication, system or self-diagnostics and troubleshooting.
Adaptable to continuous firing, high-low or modulating firing rate for semi-automatic burner sequencing.
Operates with the following:
*Torch-ignited main burner or torch-ignited pilot using S445A Start-Stop Station, or conventional knee or foot operated
station.
*Direct-ignition oil burner or electrically ignited pilot, using S445A Start-Stop Station
Five LEDs provide sequence information.
Non-volatile memory.
Flame signal check during standby.
Compatible with existing Honeywell flame detectors.
Order No. Description Replaces1
RM7885A1015 Semi-automatic primary control 120/60 R485
1
To replace R485, select R7847 Flame Signal Amplifier

RM7890A, B, C, PRIMARY CONTROL


Microprocessor-based integrated primary burner control for automatically fired gas, oil, coal or combination fuel single burner applications.
Provides level of safety, functional capability and features beyond conventional controls. Functions include automatic burner sequencing,
flame supervision, system status indication, system or self-diagnostics and troubleshooting. Five LEDs provide sequence information.
Selectable recycle or lockout on loss of flame. Nonvolatile memory retains history files and sequence status after loss of power.

Pilot Flame
Establishing Period
Order No. Description (PFEP) Replaces1
RM7890A1056² Automatic primary relay module, 120/60, Intermittent Pilot 4 or 10 seconds RA890F,G,H, RM7890A1015
RM7890B1048² Automatic primary relay module, 120/60, shutter drive. 4 or 10 seconds RA890F,G,H, RM7890B1014
RM7890C1005 Automatic primary relay module, 120/60, Standing Pilot 4 or 10 seconds RA890F,G,H
1
To replace RA890F, select R7847A Flame Signal Amplifier. To replace RA890G, select R7849A Flame Signal Amplifier. To replace RA890H,
select R7847B Flame Signal Amplifier. Check timings for application requirements.
² Enhanced Version with Pre Ignition Interlock and Valve Proving capability.

Note: Required Components: R7847, R7848, R7849, R7886A Flame Signal Amplifiers and Q7800 Universal Wiring Subbase. S7800
Keyboard Display as an option.

152 www.federalcorp.com
___________HONEYWELL FLAME SAFEGUARD
RM7895A/RM7896 FULL FUNCTION PRIMARY CONTROL
Microprocessor-based integrated primary burner control for automatically fired gas, oil, coal or combination fuel single burner
applications. Provides level of safety, functional capability and features beyond conventional controls. Functions include
automatic burner sequencing, flame supervision, system status indication, system or self-diagnostics and trouble shooting. Five
LEDs provide sequence information. Selectable recycle or lockout on loss of flame or airflow. Nonvolatile memory retains history
files and lockout status after loss of power.

Airflow Switch
Order No. Description Check (AFSC) Replaces 1
RM7895D1011 Interrupted primary relay module with with delayed main valve and Yes R7795G,H
pre-purge.
RM7896D1027 Interrupted primary relay module with delayed main valve plus pre- Yes R7795G,H
purge and post-purge.
1
To replace R7795A,C,E,F, select R7849A Flame Signal Amplifier. To replace R7795B,D,F,H, select R7847A Flame Signal
Amplifier.

RM7898A ENHANCED FULL FUNCTION PRIMARY CONTROL


Microprocessor-based integrated primary burner control for automatically fired gas, oil, coal or combination fuel single burner applications. Provides
level of safety, functional capability and features beyond conventional controls. Functions include automatic burner sequencing, flame supervision,
system status indication, system or self-diagnostics and trouble shooting. Five LEDs provide sequence information. Selectable recycle or lockout on
loss of flame or airflow. Nonvolatile memory retains history files and lockout status after loss of power. Includes Valve Proving Sequence,
Programmable Post Purge, and Pre Ignition Interlock input.

Airflow Switch
Order No. Description Check (AFSC) Replaces 1
RM7898A1000 Intermittent primary relay module without AFSC, 120/60 No R7795A,B, RM7895A,C, RM7896A,C
RM7898A1018 Intermittent primary relay module without AFSC, 120/60 No R7795E,F, RM7895A,C
1
Check Cross Reference and application.
Note: Required Components: Q7800 Universal Wiring Subbase, R7847, R7848, R7849, R7886 Flame Signal Amplifiers, and ST7800 Plug-in Purge

4
Timers.

Q7800A, B 22-TERMINAL UNIVERSAL WIRING SUBBASES


Burner, panel or wall mount subbases for 7800 SERIES relay modules and S7830A Expanded Annunciator. Makes
electrical connections for 7800 SERIES relay modules or S7830A Expanded Annunciator through bifurcated
contacts. Provides terminals for field wiring. Twenty-two terminals.
Order No. Description
Q7800A1005 Universal wiring subbase, panel mounting
Q7800B1003 Universal wiring subbase, burner or wall mounting, knockouts
provided in back, top, and bottom for conduit connections.

R7140 PROGRAMMERS
The R7140 Burner Control Modules are microprocessor-based integrated burner control for
automatically fired gas, oil, or combination fuel single burner applications. Functions include
automatic burner sequencing, flame supervision, system status indication, system or self-
diagnostics and troubleshooting. Please Note: It will be more cost effective to replace with
RM7800 Series and rewire.
Pilot Flame Main Flame
Establishing Establishing
Order No.1 Period Period Interlocks Application
R7140G2008 10 sec, 15 4 sec or 10 Running Upgrade replacement
sec, 30 sec or sec Programming Control for
Intermittent BC7000L with PM720G or
R4140G with start interlocks

R7140L2007 10 sec or 15 4 sec or 10 Interrupted Upgrade replacement


sec sec Programming Control for
BC7000L with PM 720L
1
Also requires ST7800 Purge Timer and appropriate R78XX Amplifier to complete the
replacement.

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 153


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL FLAME SAFEGUARD___________
ST7800A PLUG-IN PURGE TIMER CARD
Provides prepurge timing for RM7800, RM7840, RM7895, RM7838 Relay Modules.
Order No. Description Prepurge Timing
ST7800A1013 PURGE TIMER 7 seconds
ST7800A1021 PURGE TIMER 10 seconds
ST7800A1039 PURGE TIMER 30 seconds
ST7800A1054 PURGE TIMER 60 seconds
ST7800A1062 PURGE TIMER 90 seconds
ST7800A1088 PURGE TIMER 4.0 minutes
ST7800A1096 PURGE TIMER 6.0 minutes
ST7800A1104 PURGE TIMER 9.0 minutes
ST7800A1120 PURGE TIMER 15.0 minutes
ST7800A1138 PURGE TIMER 22.0 minutes

R7847, R7848, R7849,R7851, R7852, R7861 FLAME SIGNAL AMPLIFIERS


Solid state plug-in amplifiers that respond to flame detector inputs to indicate the presence of flame when used with 7800 SERIES relay modules.
Flame failure response time of 0.8 or 1 second; or 2.0 or 3.0 seconds, depending on amplifier and relay module selected. Flame signal strength
ranges from 0.0 to 5.0 Vdc. Plug into 7800 relay module through printed circuit board edge connector keyed for proper orientation. Flame signal test
jacks to measure amplifier flame signal voltage. R7847B; R7848B; R7849B, R7851, R7852 Dynamic AMPLI-CHECK ® circuitry tests all flame
amplifier components 12 times per minute. The 7800 SERIES Relay Module locks out on safety shutdown with amplifier failure. R7824C, R7847C
Dynamic Self-Check Rectification Amplifiers, R7861 Self-Check Ultraviolet Flame Amplifier and R7886A Dynamic Self-Check Ultraviolet Amplifier test
the detectors and all electronic components in the flame detection system 12 times per minute; 7800 SERIES relay module locks out on safety
shutdown with flame detection system failure.

Plug-in Flame Signal Amplifiers Applicable Flame Detectors


Flame Failure
Response
Order No. Type Color Self-Checking Time Fuel Type Models
R7847A1025 Rectification Green No 0.8 seconds Gas Rectifying Flame C7004, C7007, C70111, Complete
Rod Holder Assemblies: C7008, C7009, Q179

4 R7847A1033 Rectification Green No 3.0 seconds Gas Rectifying Flame


Rod Holder
C7004, C7007, C70111, Complete
Assemblies: C7008, C7009, Q179

Oil Photocell 2 C7010, C7013, C7014


R7847B1031 Rectification Green Dynamic 3.0 seconds Gas Rectifying Flame C7004, C7007, C70111, Complete
Ampli-Check TM Rod Holder Assemblies: C7008, C7009, Q179

Oil Photocell 2 C7010, C7013, C7014


R7847C1005 Rectification Green Dynamic 3.0 seconds Gas, oil, Ultraviolet (Purple C7012E,F
Self-Check coal Peeper)
R7848A1008 Infrared Red No 3.0 seconds Gas, oil, Infrared (Lead C7015
coal Sulfide)
R7848B1006 Infrared Red Yes 2.0 or 3.0 Gas, oil, Infrared (Lead C7015
seconds coal Sulfide)
R7849A1015 Ultraviolet Purple No 0.8 seconds Gas, oil Ultraviolet C7027, C7035, C70443
(Minipeeper)
R7849A1023 Ultraviolet Purple No 3.0 seconds Gas, oil Ultraviolet C7027, C7035, C70443
(Minipeeper)
R7849B1021 Ultraviolet Purple Dynamic 3.0 seconds Gas, oil Ultraviolet C7027, C7035, C70443
Ampli-Check TM (Minipeeper)

R7851B1000 Ultraviolet, White Dynamic 2.0 or 3.0 Gas, oil, Ultraviolet Optical C7927, C7962
Visiable Light Ampli-Check TM seconds coal Visible Light

R7851B1018 Ultraviolet, White Dynamic 0.8 sec or 1.0 Gas, oil, Ultraviolet Optical C7927, C7962
Visiable Light Ampli-Check TM sec coal Visible Light

R7852B1009 Infrared Red/White Dynamic 2.0 or 3.0 Gas, oil, Infrared C7915
Ampli-Check TM seconds coal

R7861A1026 Ultraviolet Purple Dynamic 2.0 or 3.0 Gas, oil Ultraviolet C7027, C7035, C70443
Self-Check seconds (Minipeeper)
1
See instructions for holder.
2
Use only Honeywell Photocell, part no. 38316
3
R7849 and C7027, C7035, and C7044 Flame Detectors should be used only on burners that cycle on-off at least once every twenty-four hours.
Appliances with burners that remain on for twenty-four hours continuously or longer should use C7012,E/F Flame Detector with R7847C Amplifier or
C7076A Flame Detector with R7886A Amplifier as ultraviolet flame detection system.

154 www.federalcorp.com
___________HONEYWELL FLAME SAFEGUARD
S7800A KEYBOARD DISPLAY MODULE
Provides current status of burner sequence, timing information, hold information and lockout information, as well as selectable or
preemptive messages. First-out annunciation and system diagnostics provided by 2 row by 20 column Vacuum Fluorescent Display
(VFD). Provides burner controller data. Remote reset. Enhanced version with Valve Proving, Postpurge, "Call Service", and Expanded
Annunciator programming ability.
Order No. Description Used With
S7800A1142 Keyboard Display Module RM7800, RM7840, RM7838, RM7895, RM7890, RM7885, RM7823 Relay Modules
Replaces S7800A1001

S7820A REMOTE RESET MODULE


Serves as link between remote reset pushbutton and relay module. Allows 7800 SERIES relay module to be reset from a remote
location. Reset button can be installed up to 1000 feet away. Installs directly on the front of 7800 SERIES relay module.

Order No. Application/Description Used With


S7820A1007 Remote reset module to reset 7800 Series relay modules. 7800 Series Relay Modules.

S7830A FIRST-OUT EXPANDED ANNUNCIATOR


Microprocessor-based expanded annunciator to support the 7800 SERIES relay modules for first-out annunciation, sequencing,
system or self-diagnostics and troubleshooting. Twenty-six status LEDs. Front panel LED array-arranged to indicate flow of line-
voltage through string of limits, controls and interlocks. Selectable current and first-out LED array display status. Twenty-one
monitored contact points. Access for external electrical voltage checks.

Order No. Dimensions Weight Electrical Output


S7830A1005 5"(W) x 5"(H) x 3 1/32"(D) 1 lb., 13 oz. 120 Vac @ 50/60 Hz

7800 ACCESSORIES

4
Order No. Description
203541 5-Prong Connector for S7800A
206311 Carrying case for S7800A
204718A NEMA 4 cover assembly for S7800A.
221818A 6' remote display cable for 7800 series controls.
H203675 Bracket remote mounting for S7800 display

__________________HONEYWELL PNEUMATIC
LP914 PNEUMATIC TEMPERATURE SENSOR
One-pipe, direct-acting temperature sensor used with RP908/RP920 Controllers to provide proportional control of
pneumatic valve or damper actuators. Rod and tube insertion element for duct, well, or through-the-wall
mounting.Connection is push-on barb for 5/32" and 1/4" tubing. Output is 3 to 15psi over temperature sensing
range.Diameter of element is 11/32".

Temperature Sensing Element


Order No. Application/Description Range Length Mounting
LP914A1003 TEMP SENSOR DUCT MTD 40/160oF 40 to 160oF. 15" Duct
LP914A1052 TEMP SENSOR WELL MTD 40/240oF 40 to 240oF. 7" Well
LP914A1060 TEMP SENSOR WELL MTD - 40/160oF 40 to 160oF. 7" Well

MP953C & D PNEUMATIC VALVE ACTUATORS


Pneumatic actuators for V5011 and V5013 valves. Rolling diaphragm for long life. Direct or reverse acting
models available. Easily attached to the valve. Slide lock feature permits simple engagement to valve stem.
Order No. Description Spring Range Travel Includes
MP953C1000 Valve Actuator, 5" Diaphragm, Direct Acting 2-7 psi 3/4" Neoprene Diaphragm
MP953C1018 Valve Actuator, 5" Diaphragm, Direct Acting 8-12 psi 3/4" Neoprene Diaphragm
MP953C1026 Valve Actuator, 5" Diaphragm, Direct Acting 4-11 psi 3/4" Neoprene Diaphragm
MP953C1075 Valve Actuator, 8" Diaphragm, Direct Acting 8-12 PSI 3/4" Neoprene Diaphragm
MP953C1489 1 Valve Actuator, 13" Diaphragm, Direct Acting 4-11 psi 1 1/2" Neoprene Diaphragm
MP953D1107 Valve Actuator, 7 1/8" Diaphragm, Reverse Acting 8-13 psi 3/4" EPDM Diaphragm
1
Stem extension assembly furnished with device.

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 155


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL PNEUMATIC__________________
P658 PNEUMATIC/ELECTRIC SWITCH p g
switching action (spdt) to provide start and stop control of equipment such as fans and
pumps.
Switch Differential
Order No. Mounting Action Setpoint (Fixed) Psi
P658A1013 Surface 1 Factory set at 10psi; 2 psi
field adjustable 2-24psi

1
Makes R to B and breaks R to W on a pressure fall to the setpoint; makes R to W and breaks R to B on a
pressure rise to the setpoint plus the differential.

RP920 PNEUMATIC CONTROLLER


Proportional, high capacity, single or dual input pneumatic controller used in conjunction with remote
sensors to provide proportional (P) or proportional plus integral (P+I) control of temperature, humidity,
pressure or dewpoint for heating and air conditioning systems. Replacement devices are available for
Johnson, Powers, Robertshaw, Barber-Colman, and older Honeywell controllers.
Order No. Application/Description Includes
RP920A1025 Single input, direct acting 1 Remote control point adjustment capability
RP920A1033 Single input, direct acting 1 No remote control point adjustment capability
RP920B1023 Dual input, direct acting 1 Remote control point adjustment capability
1
May be field reversed

RP972 PNEUMATIC REVERSING RELAY


A modulating relay suitable for all types of heating and air conditioning control
systems to reverse and increase the capacity of the branchline pressure to the final
control element. The output varies inversely with the input with an adjustable offset.
Order No. Description Includes
RP972A1006 Reversing Relay Mounting clip

4 TP970 PNEUMATIC THERMOSTATS


Two-pipe, single setpoint, high-capacity pneumatic thermostat used to provide proportional control of pneumatic
valves and damper actuators in heating and air conditioning systems. Replacement kits are available for
Johnson, Powers, Robertshaw, Barber-Colman, and older Honeywell two-pipe pneumatic thermostats.

Scale Throttling
Order No. Description Range Range Remarks
TP970A2004 Two-pipe, Direct acting 60-90 oF 2-10 oF Order cover separately.
TP970A2038 Two-pipe, Direct acting modernization kit 60-90 oF 2-10 oF Modernization kit includes:
thermostat,universal adapter and
universal satin chrome cover
TP970A2145 Two-pipe, Direct acting, Convertastat 60-90 F 2-10 F Convertastat includes: thermostat,
o o

universal adapter, wall plate, and


universal satin chrome cover.
TP970B2002 Two-pipe, Reserve acting 60-90 oF 2-10 oF Order cover separately.

TP972 PNEUMATIC HEATING/COOLING THERMOSTATS


Two-pipe, one or two temperature, dual pressure pneumatic thermostat used to provide proportional
control of pneumatic valves and damper actuators.
Order No. Description Scale Range Throttling Range Remarks
TP972A2002 Two-pipe, single temperature, direct o
60-90 F. 2-10 oF. Order cover
acting at 18psi, reverse acting at separately
TP972A2192 Two-pipe, single temperature, direct o
60-90 F. 2-10oF. Convertastat
acting at 18psi, reverse acting at includes:thermostat,
13psi, Convertastat universal adapter,
wall plate, and

TP973 PNEUMATIC THERMOSTAT


One-pipe or two-pipe single temperature, direct acting, low capacity, bleed-
type pneumatic thermostat used to provide proportional control of
pneumatic valves and damper actuators.
Order No. Scale Range Throttling Range Remarks
TP973A2076 60-90º F. 2-10º F. Order cover separately

156 www.federalcorp.com
___________UNIVERSAL PNEUMATIC TOOL KIT
HONEYWELL PNEUMATIC PARTS
Order No. Description Order No. Description
H311750 Diaphragm for 8" MP953C 14002040002 Diaphragm for MP953D
H312505 Diaphragm for 13" MP953C CCT729A Gauge adapter for TP97X thermostats
H312760 Diaphragm for 5" MP953C 316059A Yoke assy. For MP953D & F ACT
14001213001 Diaphragm for MP904

UNIVERSAL PNEUMATIC TOOL KIT


Includes all special tools required to calibrate all major manufacturers brands of pneumatic controls.
Order No. Description
MGK1010 Includes JC5216 squeeze bulb; 242001 gauge(0-30#); Federal screwdriver; CCT729A gauge adapter
for Honeywell thermostats; JC5312 gauge adapter for Johnson thermostats; JC5361 needle and
adapter for Johnson thermostats,receiver-controllers & transmitters; JT4000119 calibration wrench &
screwdriver for Johnson thermostat covers; 192759EA gauge adapter for Siemens; 856055 Siemens
thermstat tool; 192632EA Siemens thermostat tool; 192632EA Siemens universal tool; 22138
Invensys gauge adapter; TOOL85 Invensys calibration tool; and 20881 Invensys calibration tool. Also
included are 2 each R37102007 straight restrictors and 2 each R37103007 tee restrictors, a various
assortment of brass fittings and several lengths of tubing. The tool kit includes a plastic tool box .

NOTE : All items in the kit are available for individual sale.

___________ __HONEYWELL FIELD SOLUTIONS


LEADERLINE CONTROLLER FAMILY
UDC 2500 UNIVERSAL DIGITAL CONTROLLER
A low-cost 1/4 DIN digital controller providing multi-language prompts and code for unmatched operator simplicity.
Universal inputs.

4
Order No. Model No. Control Type Alarms (Qty) Accutune III™
DC2500C00000200 DC2500-C0-0000-200-00000-E0-0 Current 0 Yes
DC2500CE0000200 DC2500-CE-0000-200-00000-E0-0 Current 1 Yes
DC2500EE0L00200 DC2500-EE-0L00-200-10000-E0-0 Limit 1 Yes
DC2500E00L00200 DC2500-E0-0L00-200-10000-E0-0 Limit 0 Yes
DC2500EE0000200 DC2500-EE-0000-200-00000-EO-0 Electro Mechanical 1 Yes

UDC 3200 VERSA-PRO DIGITAL CONTROLLER


A 1/4 DIN general-purpose digital controller offering a high degree of functionality and operating simplicity. It now offers
multi-language prompts, Basic Math, 2 loop operation and HealthWatch diagnostic software. Universal inputs.
Order No. Model No.1 Control Type Alarms (Qty) Acctune III™
DC3200CB000R200 DC3200-CB-000R-200-00000-E0-0 Current 1 Yes
DC3200CE000R200 DC3200-CE-000R-200-10000-E0-0 Current 1 Yes
DC3200EE000R200 DC3200-EE-000R-200-00000-E0-0 Electro Mechanical 1 Yes
DC3200EE000R240 DC3200-EE-000R-240-00000-E0-0 Electro Mechanical 1 Yes
1
These models have infrared interface

ACCESSORIES FOR UDC3200 CONTROLLERS


Order No. Model No. Description
30756687501 30756687-501 Auxillary Output Board
30756696501 30756696-501 Digital Input Board
30756725501 30756725-501 Solid State Relay 1 AMP
30757215001 30757215-001 NEMA 4 Kit

ACCESSORIES FOR UDC2500/3200 CONTROLLERS


Order No. Model No. Description
30755306501 30755306-501 Electro mechanical 5 amp relay
30756725501 30756725-501 Solid State relay 1 amp
51452807501 51452807-501 Dual electro mechanical relay PWA
51452810501 51452810-501 Auxillary output, digital input,
RS422/485
50152816501 51452816-501 Auxillary output, digital input, ethernet
board
51452825501 51452825-501 Analog input (2nd input)

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 157


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL FIELD SOLUTIONS_____________
LEADERLINE RECORDER FAMILY
®
DR4500 TRULINE DIGITAL RECORDER
12-inch digital circular-chart recorder that delivers top performance to meet your batch process recording needs. The
Truline model offer a variety of printing formats, incremental levels of functionality, and accuracy of ± 0.1%. The Truline
also prints its own chart, recording up to four process variables on the same timeline.
Order No. No. of Channels Input Type
DR45AT11000 DR45AT-1000-00-000-0-000000-0 1 Universal

DPR 250 MULTI-POINT DIGITAL STRIP CHART RECORDER


An exceptionally priced, high-performance 250-mm (10-inch) strip chart recorder that can monitor up to 64 analog inputs,
up to 48 digital outputs, and 48 alarm relay outputs. The DPR 250 features a rugged galvanized steel case, IP55 front
face protection, and CE approval. The recorder's six-color printing capability, alarm / digital input messaging, and its
ability to periodically print up to 10 different chart informations (such as chart range or snapshots of trace values, math
results, or digital input values), allows you to customize printed information to meet process requirements.
Order No. Model No. No. of Channels Input Type
SPECIAL ORDER D25-U0000000-00000000-000-0-0000-00-U 4 Universal

ACCESSORIES
Order No. Description
24001660001 10", 0-100, Linear, 24 Hour
24001660006 Chart 0/1200F F/Type K 24Hr 10"
24001661001 10", 0-100, Linear, 7 Day
30735489002 Ink Cart./Red6-Pack for DR4300
30735489007 Ink Cart./Purple 6-Pack for DR4300
30755317001 Chart for DR45AT (Box of 100)
30756113501 Chart motor for DR4500
46190305501 Universal Input Board w/Term Block for DPR250
46181080504 250 Ohm Resistor (Per Pk of 6)
46182707001 Fanfold Type Chart, for DPR250/DPR3000
46182708001 Roll Type Chart, for DPR250/DPR3000
46182712001 Color Ribbon Cartridge

4 RECORDERS

FEATURES DPR100A/B DPR180 DPR250 DR4300 DR4500


Display Analog Digital Digital n/a Digital
Chart Size 100mm/3.94" 180mm/7.09" 250mm/9.84" 254mm/10" 305mm/12"
Reference
0.25% 0.05% 0.05% 0.10 - 0.35% 0.10%
Accuracy
Multipoint
6 (DPR100B) 24 64 2 4 (Truline)
Channels
Input Type T/C, RTD, 4-20 mA, mV
Loops of N/A - Basic,
1 or 2 1 1 2
Control 2 - Enhanced
Digital I/O 0/0 0/0 2/0 1/0 1/0
Continuous
1-3 (DPR100A) N/A N/A
Pens
Roll or Fan- Roll or Fan- Roll or Fan-
Chart Type Preprinted Self-printing
Fold Fold Fold
Configuration PC or Keyboard
Data Storage N/A PCMCIA PCMCIA N/A N/A
N/A - Basic,
ASCII, Modbus, ASCII,
Comms N/A Modbus, RTU - Modbus RTU
RTU Modbus,RTU
Enhanced

Math Functions Yes Yes Yes N/A Totalization

Optional LPCS;Trend LPCS; Trend N/A - Basic,


N/A SpecView
Software Manager Pro Manager Pro SpecView -Enh.

Circular Chart recorders, in general, are preferred for batch processes. The circular chart record displays
the entire batch operation over a specific unit of time, from one hour to 31 days. An additional advantage of
the circular chart record is easy filing and copying for reference. Compared to strip chart record, the
circular chart has a shorter calibrated chart width.

158 www.federalcorp.com
_____________HONEYWELL FIELD SOLUTIONS
TRENDVIEW
SPECIAL ORDER ITEMS

EZ-TREND QXE MINITREND QX MULTITRENDPLUS SX


FEATURES

Display 5.0" color LCD 5.5" color LCD 12.1" color LCD
Inputs Up to 12 Up to 16 Up to 48

Input Signal
T/C, RTD,mA, mV, V, and ohms T/C, RTD,mA, mV, V and ohms T/C, RTD, mA, mV, V and ohms
Type

Scan Time 200 msec 20 msec(fast sampling, 50 Hz) 20 msec(Fast sampling, 50 Hz)

Digital I/O Up to 8 Up to 16DI/16DO Up to 16DI/16DO

Comms RS485, Modbus RTU RS485, Modbus, Ethernet RS485, Modbus, Ethernet

Full math(option) supports up to Full math (option) supports up to Full math (option) supports up to
Math 100 character free form math for 100 character free form math for 100 character free form math for
each pen. Six functions standard. each pen. Six functions standard. each pen. Six functions standard.

Accuracy 0.1% Typical Depends on input type Depends on input type

Std.
TrendViewer - Viewing, Graphing and Printing of stored data from disk. Export data files in CSV format.
Software

TrendManager Pro - advanced data analysis/archiving software. All of the capabilities of TrendViewer
plus Full configuration of Mini/Multi/Tele/CirciTrend recorders, Archive data on integral secure
database, E-mail configurations and data and Event system analysis.
Optional
TrendServer Pro - fully network aware software for communications with recorders. All of the
Software
capabilities of TrendManager Pro plus FTP(File Transfer Protocol)/ Ethernet connection (TCP/IP), Web
Browser access, Audit trail manager/ advance password protection, Distribution of data available over
LAN (Local Area Network) and Export using OPC links. 4
MODULAR CONTROL SOLUTIONS
UMC 800 UNIVERSAL MULTILOOP CONTROLLER
The UMC 800 controller delivers loop and logic control plus data acquisition in an integrated package to cost-effectively satisfy the
automation requirements of standalone unit processes. The controller’s advanced features combined with a hardened operator interface and
easy-to-use configuration software deliver uncompromising performance in a tightly integrated control package. Contact Federal's Industrial
Controls Department for more information or application details.

HC 900 UNIVERSAL MULTILOOP CONTROLLER


The HC900 is Honeywell’s next generation of hybrid control for cost-effectively automating process equipment, either standalone or with open
Ethernet Modbus/TCP connectivity. Offering a blend of process, logic, and sequence control algorithms combined with data acquisition, a
modular design and a graphical configuration tool, the HC900 is easily applied in applications across various industries. This includes control
of furnaces, dryers, boilers, sterilizers, autoclaves, reactors, water treatment, utility balance of plant equipment and related data acquisition.
The easy-to-use Windows-based Hybrid Control Designer software tool graphically configures the controller and optional local plant floor
Operator Interface, saving configuration time and cost. The run-mode configuration edit capability plus monitoring functions minimize process
interruption, saving start-up time and allowing continual process improvement while running. Contact Federal's Industrial Controls
Department for more information or application details.

Whether you have a batch, continuous process, or combined data acquisition application, the HC900 controller supports an extended range
of use using a variety of diverse control strategies with 2 model types. The expanded model supports 32 control loops, 512 I/O, a function
block library of over 100 block types, large function block capacity of 2000 blocks, and Ethernet peer-to-peer communications. High
accuracy, universal analog inputs and PID control algorithms with auto-tuning assure accurate control.

This allows you to start up your process in minimum time and keep it under control to reduce defects and improve throughput. Setpoint
programmer functions allow batch thermal processes to be easily configured with profiles and recipes. Support logic and 64-step sequencer
functions also insure complete loop and logic integration. The compact 4, 8, or 12 I/O slot rack sizes along with a mix of higher density I/O
cards preserve cabinet space while remote racks allow I/O distribution to save wiring costs. I/O insertion/removal under power with auto-
configuration minimizes downtime for process expansion. Configurable serial Modbus RS232 and RS485 ports allow connection of
touchscreen panels, Honeywell controllers/recorders and third party I/O. Contact Federal's Industrial Controls Department for more
information or application details.

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 159


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL FIELD SOLUTIONS_____________
SOFTWARE TOOLS
SPECVIEW
SpecView 32 is a low cost, easy-to-use, centralized PC software that provides supervisory control, data acquisition, recipe management
and batch reporting. SpecView 32 operates in all current Windows operating systems environment - 98, ME, NT, XP, and 2000. The
optional OPC client capability allows easy linkage to other OPC server products. SpecView's instrument view capability minimizes
database creation for easy configuration.
TRENDMANAGER PROSOFTWARE SUITE
Trendmanager Suite provides the ability to configure, network, and customize the displays configuration for the
Mini/Multi/Tele/CirciTrend family of paperless recorders.
LPCS
LeaderLine Personal Computer Software (LPCS) is a low-cost and easy-to-use Windows based application designed for device
configuration, operation, monitoring and archiving. Devices currently connectable to LPCS are UDC2300, UDC3300, UDC6300,
DPR100 C/D, DPR180 and DPR250. Communication is RS485-ASCII for up to 16 devices at 19.2 K maximum baud rate.
PROCESS INSTRUMENT EXPLORER
This software runs on a pocket PC, desktop or laptop and allows the user to quickly set up and configure UDC2500/3200/3500
controllers. Users can create/edit configurations live or offline via RS-485, Ethernet or infrared communications.

SMARTLINE CONFIGURATION TOOLKIT


The Smartline Configuration Toolkit is a PC-based engineering and maintenance tool designed specifically for use with Honeywell's
Smartline ® family of field instrumentation products. The toolkit runs on PCs with Windows 98, 2000 or XP operating systems. It
allows easy access to all Smartline configuration database parameters.

VISTA 400 SUPERVISORY PC SOFTWARE


This software features client/server architecture over Ethernet with up to five client Stations, runs on Windows XP or 2000 Professional
OS, point sizes up to 2000 points (1 control loop= 1 point).Standard group, detail, trend, alarm and event displays. Comprehensive
alarm support with priorities, display filtering and common annunciation for all displays.
MC TOOLKIT CONFIGURATOR
The MC Toolkit Configurator is a Pocket PC-based engineering and maintenance tool for configuring, monitoring, diagnosing and
managing smart field instruments/devices.

THERMOCOUPLES AND WIRE

4 Megopak thermocouples consist of the T/C wires with magnesium oxide insulation in sheath of 316 SS. These materials are
compacted into one solid mass providing small diameter sensors for many applications.This structure enables the sensor to be
constructed in a diameter of 1/4". They can be easily bent and configured to match the physical requirements of the application.
Order No. Model No. T/CPL Type Length Head Type Sheath Material
002J4M15R0504 002J-4-M-15-R05-04-0-000-00000-0 J 5" 316SS
002J4M15R1204 002J-4-M-15-R12-04-0-000-00000-0 J 12" General Purpose 316SS
002K4M15R0604 002K-4-M-15-R06-04-0-000-00000-0 K 6" 1/2" MNPT 316SS
002K4M15R1204 002K-4-M-15-R12-04-0-000-00000-0 K 12" 316SS
3W2P4 303W2P4 J Sold per foot Poly/Poly
5W2P14 305W2P14 K Sold per foot Poly/Poly

160 www.federalcorp.com
______________HONEYWELL FIELD SOLUTIONS
HERCULINE ELECTRIC ACTUATORS
®

Honeywell's Herculine Electric Actuators are engineered for exceptional


®

reliability, accurate positioning, and low maintenance. Designed for very precise
positioning of dampers and quarter-turn valves, they perform especially well in
extremely demanding environments requiring continuous duty, high reliability,
and low maintenance. With non-contact sensing, the maintenance problems
and unexpected shutdowns associated with slidewires and potentiometer wear
are eliminated.

FEATURES 2000 2001/2002 10260


Description Low torque Low torque Medium torque
Torque 50 - 400 in-lb 50 - 400 in-lb 10 - 300 lb-ft
90º-160º / 15 to 240 90º-160º / 7.5 to 120 90º / 20/40/60
Stroke/Speed
seconds seconds seconds
1-5 Vdc, 4-20mA, 1-5 Vdc, 4-20mA,
Input Signals 2-10 Vdc, 4-20mA Floating, Pos. Prop., Floating, Pos. Prop.,
Open/Close Open/Close
Position 2001: slidewire
Slidewire Contactless
Feedback 2002: contactless
Environmental -40 to 185ºF -40 to 170ºF -20 to 170ºF
Duty Cycle Continuous Continuous Continuous
Repeatability N/A 0.2% of 90º span <0.2% span
Dead-Band

Local Auto/Man
Adj. 0.2% to 5% Span Adj. 2% to 5% Span Adj. 0.2% to 5% Span
4
Optional Optional Optional
Switch

Local Keyboard
N/A Optional 10260S: Optional
Display

RE485 Modbus
N/A Yes 10260S: Yes
Comms

State-of-the-art control systems require accurate, responsive, and repeatable actuation of


final control devices to operate with maximum efficiency and improve process control.
Actuators are often overlooked when considering the performance of a control system.
Combined with maintenance and ancillary support costs, they will directly impact your
company's bottom line.

OKLAHOMA CITY • (405) 239-7301 TULSA • (918) 249-1918 161


(800) 289-3331 • FAX: (405) 232-5438 (800) 955-1918 • FAX: (918) 249-9014
HONEYWELL FIELD SOLUTIONS_____________
SMV 3000 SMART MULTIVARIABLE FLOW TRANSMITTERS
DIFFERENTIAL PRESSURE, STATIC PRESSURE, PROCESS TEMPERATURE & FLOWRATE
Flexible Electronics design allows RTD or Thermocouple input with standard wiring. "Smart" features include
remote communication, calibration, configuration and diagnostics.
Differential Pressure Pressure
Order No.1 Range Range Meter Body Description

0-1"/25" w.c. 0- 0-100 psia Zinc-plated Carbon Steel Process Head; 316 SS vent/drain
SMA110A1H 2.5 to 0-62.5 mbar (7.0 bara) valves & plugs; 316L SS Barrier diaphragms
0-1"/400" w.c. 0- 0-750 psia 316 SS Process Head and vent/drain valves & Plugs; 316 SS
SMA125E1H 2.5 to 0-1000 mbar (52.5 bara) Barrier Diaphragms
1
Many other models available by Special Order.

ST 3000 SMART PRESSURE TRANSMITTERS


"Smart" features include remote communication, calibration, configuration and diagnostics.
Reference accuracy is ±0.1% of span in analog mode and ±0.075% in digital mode.
Order No. 1 Span Materials of Construction

0-10" to 0-400" w.c./ Process wetted heads, vent/drain valves and plugs
STD924E1H 0-25 to 0- 1,000 mbar are 316 SS; Barrier diaphragms are 316L SS
0-20 to 0-500 psig/ 0- Process wetted heads are 316 SS and
STG94LE1G 1.4 to 0-35 bar Barrier diaphragms are 316L SS
1
Other models available by Special Order

162 www.federalcorp.com