Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
ABBs solutions are based on strong and stable architectures Sustainably manufactured in Switzerland to the highest of
that make sure your important application is supported by standards, ABBs Power Protection products employ a variety
the very best power protection system, ready to step in and of technologies from traditional designs to our leading range
take over at the first sign of trouble. of modular products that allow a power protection system
to be added to module by module, as and when required.
This product catalogue provides details of ABBs Power This reduces initial capital outlay and simplifies maintenance.
Protection solutions and will guide you in choosing which
ones are suitable for your needs. ABB is always there to provide consultancy so that you
can choose the product that is exactly right for you.
Our uninterruptible power supplies (UPS) and ancillary And afterwards, our global, first-class service organization
products cover a wide range of applications and power is at your disposal in more than100 locations.
from small offices to large data centers. And for each
and every user ABBs mission is to provide power protection Please browse the catalogue to learn more about the ABB
that ensures the highest availability and the lowest cost Power Protection group, our approach to power protection
of ownership. and details of our products. If you require guidance, we
are always ready to assist you in person, or you can visit
www.abb.com/ups.
About us 4
Connectivity solutions 60
The ABB Power Protection product group was formed the attention of the ABB Group, who acquired Newave in
from the combination of the three ABB product lines early 2012. This acquisition propelled ABB to the forefront
UPS, Power Conditioning and Power Solutions. The three of the power protection industry as the companys portfolio
businesses have their roots in the formerly acquired complements the rest of ABBs Power Protection offering to
companies Newave (UPS), Vectek and Cyberex. give a unique line-up of UPS, power conditioning and power
switching products designed to solve power quality issues in
Newave SA was founded in Ticino, Switzerland in1993 to all sorts of commercial and industrial applications.
market innovative UPS technology. From the very start, the
company was a UPS innovator and by1994 had designed, Through an expanding team of local business units and
manufactured and launched its first generation of three- channel partners and an array of innovative products ABB
phase, transformerless standalone UPS. Further innovation is well positioned for further growth in the global UPS and
followed and the UPS product portfolio grew through several power protection market. And there are innovative products
generations to cover three-phase applications and ever-higher to match: For example, the unique Decentralized Parallel
powers. Architecture (DPA) featured in UPSs like the Conceptpower
DPA 500 is just one innovation from a pioneering company
In1998, the first generation of modular UPSs was introduced. that has over 20 years of UPS design under its belt.
The modular approach delivers a low total cost of ownership
and has proven to be a runaway success with customers. www.abb.com/ups
The companys innovation and accomplishments attracted
For a company to know its direction of travel and know in everything we do. Knowing our customers better, being
what it stands for, it has to have visions and values. perceived as having a clear focus on them and providing
high-quality offerings and services will make us the partner
Power and productivity for a better world describes what of choice.
ABB stands for. In power we are a leader in addressing
power infrastructure and control needs for utilities, industry, Innovation and speed
transport and infrastructure. In productivity ABB is a leader Innovation is at the core of our value proposition and will
in operational asset effectiveness we support our customers continue to be critical in strengthening and enhancing our
in achieving high uptime and speed while reducing waste. competitive position in daily business, and as we expand
our offering towards engineering/consulting, software and
a better world refers to our value proposition to decouple value-added services. Speed is essential in everything we do
economic growth from environmental pollution. Based on our being efficient with a high quality and without haste is the
offering and technologies, we are well positioned to enable art that we are committed to mastering.
growth with less relative energy consumption and make the
still-needed energy supply cleaner and more sustainable. Ownership and performance
Strengthening clear lines of responsibility and accountability
Our vision is clear: our daily actions need to be built on across our organization is a key part of our Next Level
the right set of values and not only for the world of today strategy. Institutional and individual performance are key to
but also for the world of tomorrow. continue to not only survive but succeed in a demanding
world. Performance is what is expected from all of us every
Our values can be summarized as five value pairs that day not only continuing what we are doing, but also taking a
are both fundamental and inspirational: step forward.
Factory certification
ISO 9001 and14001
OHSAS18001
Good customer service is the lifeblood of any business or Customers can contact their local ABB representative or
organization. This fact is well understood by ABB and the nominated ABB partner for assistance. A local field service
is the fundamental reason why good customer service is engineer will help the customer to solve the issue, either
driven by ABB management and is of equal importance by phone or by going on-site. If the field service engineer is in
for all staff. need of assistance, they are able to contact the round-the-
clock, 24365 ABB support line in Switzerland. The support
ABBs service footprint for the UPS product line is global and line expert assists the local field service engineer in solving
is provided by ABB itself or by members of ABBs partner the issue by phone and electronic ticketing system as well as
network. All ABB and partner service engineers go through local intervention when required. The support team experts
intense product-specific training before they are allowed are always on duty and will return any call at any time.
to carry out service work at a customer site.
ABBs approach to modular power protection Some modular UPS systems with a centralized parallel
Despite all the precautions taken during the design and architecture (CPA) have centralized control or hardware.
operation of data centers and related control processes, This renders them very vulnerable should a fault occur on
situations can arise in which external power is compromised one of these centralized components; one fault can bring
either in terms of quality or availability. Such events could down the entire UPS system.
result in data loss, nonavailability of essential services, risk to
hardware and very high financial losses. This makes a highly With DPA, on the other hand, the UPS is modularized and
dependable UPS mission-critical. Therefore, the most critical each module has all the hardware and software needed for
loads should be protected by the very best UPS design autonomous operation rectifier, inverter, battery converter,
Decentralized Parallel Architecture (DPA). static bypass switch, back-feed protection, control logic,
display, and mimic diagram for monitoring and control.
ABB, a pioneer and leader in large, modular UPSs, provides With all the critical components duplicated and distributed
a full range of modular DPA power protection products as between individual units, potential single points of failure
well a standalone solutions. In the following four pages, we are eliminated. In the unlikely event of one UPS module
will focus on our approach to modular power protection and failing, the failed module will be automatically isolated and
describe how these modular solutions can help ensure a the overall system will continue to operate normally.
supply of clean, reliable power to the customers application.
Power module Output to the UPS module Control logic Output to the
critical load display critical load
In DPA, each UPS module has all the hardware and software it
needs for autonomous operation.
True online-swap modularity enables the safe removal and The ability to scale the system means the UPS can be sized
insertion of UPS modules without risk to the critical load exactly to fit prevailing needs and modules can simply be
and without the need to either transfer it onto raw mains or added as requirements grow. This means that you only power,
remove power from it. Modules can therefore be replaced or cable and cool what you need.
added without any system downtime. It is simple to upgrade
power capability as critical load power requirements grow. The Conceptpower DPA 500, for example, allows five100kW
Additionally, modules can easily be removed for service or modules to be mounted in one cabinet and six cabinets
replaced if faulty, without compromising the availability of to be configured in parallel to provide a top rating of 3MW.
the system. Only a truly redundant architecture like DPA Power consumption is the topic of greatest concern for
allows online modules to be swapped out while the system is data center operators and the energy savings made by this
running. modular approach over the service life time of the UPS are
substantial. Human error is reduced too: Because things are
This unique aspect of modularity directly addresses so simple, wiring errors are eliminated, and configuration
continuous uptime requirements, significantly reduces mean and reconfiguration are childs play.
time to repair (MTTR), reduces inventory levels of spare
parts and simplifies system upgrades. This approach pays
off too when it comes to serviceability and availability, as
there is no downtime and the service personnel do not need
special skills.
Scalability up to 3MW
Horizontal scalability: cabinets in
parallel configuration up to 3MW
Efficiency
100%
Eco-mode
98%
95.8% 96.1% 96.0% 95.6%
96%
94%
92%
90%
0% 25% 50% 75% 100%
Load
kW
180 Standalone solution
kW
260kW (N+1) UPS until year1
160 180 360kW (N+1) UPS years14
140 160 Oversized capacity = saving potential
Oversized capacity
120 140 Oversized capacity = saving potential
Modularity lends itself well to keeping UPS footprint small, too Vertical modularity minimizes space requirements and
ideal for data centers, where real estate can be restricted maximizes predictability of future space requirements. In the
example shown, 2m2 is saved.
and expensive. A modular UPS rack has a small footprint and
when extra modules are added, no extra floor space is taken up. Total footprint
1.11 m2
But the advantages of DPA modularity go further as Clearance
Total footprint 3.2 m2
installation and servicing costs are also kept low: 0.16 m2
A straightforward modular concept simplifies and speeds
every step of the deployment process from planning, UPS UPS UPS
through installation and commissioning to full use. DPA 0.7 m2 0.7 m2 0.4 m2
modularity also reduces costs as service engineers need
less training and spend less time on-site, and any risks
of data or production loss are minimized. Inventory levels
of spare parts are reduced.
Clearance 1m Clearance
0.55 m2 1.8 m2
Highly dependable UPSs are mission-critical for many parts
of industry. DPA delivers unmatched UPS availability and
serviceability, scalability, flexibility and low energy usage.
Traditional 2180 kW (2N) Modular up to
180 kW (N+1)
There are no better UPS architectures available to those users
whose critical electrical loads represent a valuable commercial
asset that must be kept powered at all costs.
At the core of our business is a technically advanced product equipment against all power problems: power failure, power
portfolio of high-quality and reliable three-phase and single- sag, power surge, undervoltage, overvoltage, switching
phase transformerless uninterruptible power supplies. All our transient, line noise, frequency variation and harmonic
UPSs provide online double conversion topology and are distortion.
designed for continuous power protection of critical
kVA
500
400
300
250
200
160
120
100
80
60
50
40
30
20
10
Product DPA UPScale ST DPA UPScale RI Conceptpower DPA Conceptpower DPA500 PowerLine DPA
kVA
500
400
300
250
200
160
120
100
80
60
50
40
30
20
10
System display
ABBs DPA UPScale ST is available for high density mid-sized infrastructure, DPA UPScale ST can be paralleled
applications requiring an all-in-one power protection solution horizontally to increase the capacity up to 400kW. This fully
that includes frame, UPS, battery and communications. The scalable and easily maintained UPS gives you unparalleled
solution delivers power protection from10kW to 200kW uptime and energy efficiency.
in10kW or 20kW modular steps. For a continuously growing
The DPA UPScale ST can be deployed in a variety of small- to productive and comfortable environment, thus increasing
medium-sized system architectures. In addition to traditional operational efficiency, decreasing the energy consumption
server load applications, the DPA UPScale ST is ideal to and ensuring the safety of personnel and equipment.
protect critical applications such as building management
systems (BMS). Large facilities are often provided with The DPA UPScale ST offers clean backup power for sensitive
BMS to control and monitor the buildings mechanical and electronic devices (controllers, I/O devices and user
electrical systems such as ventilation, lighting, fire alarms and interfaces) designed to monitor and control the infrastructure
security. The BMS is designed to create and maintain a safe, thus avoiding loss of data or damage to equipment.
Utility mains
Web server
User Interface1 User Interface 2
Programmable Programmable
logic controller1 logic controller 2
RS-232
Battery breakers
The rack-independent DPA UPScale RI is one of the most is required. The DPA UPScale RI, including UPS, battery
compact UPS systems on the market that is suitable for and communication, can be integrated into any19" rack
custom-designed solutions. Being modular and rack- (independent of manufacturer) and provides up to 80kW
mountable, it provides an ideal system from the technical (60kW N+1) making it ideal for integrated IT, telecom or other
and commercial point of view for when a flexible solution critical control processes.
Up to 5 UPS DPA
modules in one cabinet
DPA display
The Conceptpower DPA is a true double conversion modular thus eliminating oversizing and minimizing upfront capital
UPS designed for medium-sized critical applications. The investment. Each DPA module is self-contained and can
Conceptpower DPAs modular architecture provides very be online-swapped at any time, so nothing has to be ever
flexible power configuration based on 30/40/50kVA transferred to bypass making routine maintenance safe
modules that can be added as power requirements grow and easy.
DPA display in
each module
Battery breaker
Customer inputs
and potential-free
outputs
Inbuilt maintenance
Bypass fuses bypass switch (optional)
A data center with full uptime. That target is why ABBs has to be ever switched off making routine maintenance
Conceptpower DPA 500 is based on Decentralized Parallel safe and easy. And if you want to increase power, the UPS
Architecture (DPA). Only a truly redundant architecture like can be scaled vertically in100kW modular steps to provide up
DPA allows online modules to be swapped out while the to 500kW power in a single frame. Horizontal scalability
system is running. Each high-reliability, standardized module is also given, with up to six frames in parallel, to increase total
is self-contained and can be swapped at any time, so nothing power up to 3MW.
= 3MW
configuration to build a system of up to 3MW (horizontal
scalabiltiy).
+6
modules
The power demand of one row of server racks can vary from 100kW
up to hundreds of kW. The building block concept of Conceptpower
DPA 500 allows adaption to the changes in power demand in a
growing infrastructure.
Extendable Extendable
SECTION A-A
BOTTOM CABLE ENTRY
81
General data
System power range 100kW3MW
Nominal power/module 100kW
Nominal power/frame 500kW
Output power factor 1.0
Topology Online double conversion, Decentralized Parallel Architecture
Parallel configuration Up to 5 modules in one cabinet (500kW)/up to 6 cabinets in parallel (3MW)
Cable entry Bottom or top as standard
Serviceability Full front
Back-feed protection Built-in as standard
Input
Nominal input voltage 3380/220V+N, 3400/230V+N, 3415/240V+N
Voltage tolerance For loads <100% (10%, +15%), <80% (20%, +15%), <60% (30%, +15%)
(referred to 400/230V)
Input distortion THDi <3.5%
Frequency range 35 70 Hz
Power factor 0.99
Walk in/soft start Yes
Output
Rated output voltage 3380/220V+N, 3400/230V+N, 3415/240V+N
Voltage tolerance <1% with static load/<4% with step load
(referred to 400/230V)
Voltage distortion <2% with linear load/<4% with non linear load
Frequency 50Hz or 60Hz (selectable)
Efficiency
Overall efficiency Up to 96%
In eco-mode 99%
Environment
Protection rating IP20
Storage temperature 25C to +70C
Operating temperature 0C to +40C
Altitude (above sea level) 1000m without derating
Batteries
Types VRLA (vented lead-acid), NiCd
Battery charger Decentralized charger per module
Communications
User interface Graphical touch screen (one per frame as standard)
Decentralized LCD and mimic diagram (one per module as standard)
Communication ports USB, RS-232, potential-free contacts, SNMP (optional)
Customer interface Remote shutdown, gen-set interface, external bypass contact
Compliancy
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Performance IEC/EN 62040-3
Manufacturing ISO 9001:2008, ISO14001:2004, OHSAS18001
Weight, dimensions
Weight 975kg (500kW system)
Dimensions whd 15801975940mm
Air filter
lncoming terminals
PowerLine DPA is an online double conversion UPS and Its robust design is suitable for industrial plant environments
makes the advantages of ABBs unique modular UPS that have a variety of temperatures, dust, moisture and
architecture available for locations that are usually rough on corrosive contaminants. The PowerLine DPA is designed to
electronic equipment. PowerLine DPA is based on ABBs have a design life of 15 years. Its pre-configured options,
Decentralized Parallel Architecture (DPA) that ensures the very tailored for industry, allow agile implementations with short
best UPS design in terms of availability, serviceability, safety lead times.
and ease of use.
Local control and metering are provided via a HMI (human-machine interface) consisting of graphical display showing the UPS mimic diagram, UPS
operating status (normal, battery and bypass), and programmable alarms.
Available models
Cabinet type PowerLine DPA 2040 PowerLine DPA 6080 PowerLine DPA100120
Number of modules 1 2 3
Dimension whd 800 2 200 8 00 mm 1200 2200 800 mm 1600 2200 800 mm
Weight in kg Up to 550kg Up to 650kg Up to 850kg
(without transformers)
General data PowerLine DPA 2040 PowerLine DPA 6080 PowerLine DPA100120
System power range 20120 kVA
Nominal power/frame 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA
Number of UPS modules 1 2 3
Output power factor 1.0
Topology Online double conversion
UPS configuration Single, parallel-redundant, dual
UPS type Modular (Decentralized Parallel Architecture)
Input
Nominal input voltage 3380/220V+N, 3400/230V+N, 3415/240V + N (others on request)
Voltage tolerance For loads <100% (15%, +10%), <80% (20%, +10%), <60% (30%, +10%)
(referred to 3400/230V)
Input distortion THDi 4%
Frequency 50 or 60 (selectable)
Power factor 0.99
Output
Rated output voltage 3380/220V, 3400/230V, 3415/240V (others on request)
Voltage distortion (referred to 3400/230V) <2.5%
Frequency 50Hz or 60Hz
Overload capability 150%1min,125%10min
Output short capability 2.7 Inom
Unbalanced load 100% (all three phases regulated independently)
Crest factor 3:1 (load supported)
Efficiency
Overall efficiency/transformerless Up to 96%
In eco-mode configuration 98%
Environment
Storage temperature 25C to +70C
Operating temperature 5C to +45C
Humidity 5% to 95% without condensation
Altitude 1000m without derating
Electrical/Mechanical
Degree of protection IP31, IP42 (optional)
Color RAL7035
Cable entry Bottom, Top (optional)
Wiring Halogen free cable
Operating and maintenance access Front access
Ventilation Forced ventilation with monitored fans
Battery
Battery type VLRA /NiCd
Autonomy According to customers requirement
Communications
HMI Graphical display for control and metering, 8 programmable alarm indications
Relay contactors 8 in/9 out programmable relays
LCD On system level HMI with graphical display and alarm indications; on module level service control interface
LEDs LED for notification and alarm
Communication ports USB, RS-232, SNMP slot, potential-free contacts
Standards
Safety IEC/EN 62040-1
Electromagnetic compatibility (EMC) IEC/EN 62040-2
Performance IEC/EN 62040-3
Product certification CE
Manufacturing ISO 9001:2008, ISO14001:2004, OHSAS18001
Weight, dimensions
Weight (with modules/without transformers) Up to 550kg Up to 650kg Up to 850kg
Dimensions whd (mm) 800 2 200 8 00 mm 1200 2200 800 mm 1600 2200 800 mm
ABBs PowerValue11RT is a double-conversion online UPS The PowerValue11RT can be used as a standalone UPS
that guarantees up to10kVA of clean, reliable power for your device or installed into a standard 19"rack configuration, with
critical single-phase applications. As well as maintaining connectivity options available for each.
power to your servers, point-of-sale terminals, workstation
clusters, routers, switches, hubs and sensitive electronic Two units of the 6 or10kVA models can be configured in
equipment, the PowerValue11RT also conditions incoming parallel to provide redundancy or to increase the systems total
power to eliminate spikes, swells, sags, noise and harmonics. capacity up to 20kVA. All units can be fitted with up to four
battery modules to extend runtime.
+ Rotatable
display + Rotatable
display + Rotatable
display
UPS
10kVA
UPS
6kVA
13 kVA B/S
External Battery
External Battery Module (EBM)
Module (EBM) 610kVA
13kVA B/S
1 AC input10A
2 2 9
1 9 2 2 Ground contact
3 USB port
4 RS-232
5 SNMP/AS400 slot
3 4 3 4
5 6 EPO/dry contact input port
5 5
4 3 7 Dry contact output port
6 7 6 7 6 7 8 AC output10A
9 AC input16A
10 AC input 20 A
8
11 AC output16A
8 8
12 EPO
13 Parallel port
11
14 Bypass
15 Output circuit breaker
PowerValue11RT 12kVA B PowerValue11RT 2kVA S PowerValue11RT 3kVA B
16 AC input 55A
and 1kVA S
17 AC output 57A
18 AC output13A
19 Battery connector
5
10 2 18 20 Output 57A
21 AC input 57A
11
15
2
5
5 12
20 13 12
13
4 3
4 3 3
6 7 4
19
14
14
8 16 15
21
18
17 2
11
11
General data 1 kVA B 1 kVA S 2kVA B 2kVA S 3kVA B 3kVA S 6kVA 10kVA
Output rated power 900W 900W 1800W 1800W 2700W 2700W 5400W 9000W
Output power factor 0.9
Topology Online double conversion
Parallel configuration No Up to 2 units
Inbuilt batteries Yes No Yes No Yes No No No
Input
Nominal input voltage 208/220/230/240VAC
Input voltage tolerance 120276VAC (depending on load level)
Input current THDi <5% with full resistive load
Frequency range 4555Hz/5 466Hz
Power factor 0.99
Output
Rated output voltage 208/2 20/2 30/2 40VAC
Voltage tolerance 1% (referred to 230V)
Voltage distortion 2% linear load, 5% non linear load
Overload capability 12s.: 102130% load 2mins.: 102 130% load
on inverter 1.5s.: 130 150% load 30s.: 130 150% load
100ms.: >150% load 100ms.: >150% load
Nominal frequency 50Hz or 60Hz
Crest Factor 3:1 (load supported)
Efficiency
Overall efficiency Up to 93% Up to 94.6%
In eco-mode 95% 97%
Environment
Protection rating IP20
Storage temperature UPS: 15C to +60C; Batteries: 0C to +35C
Operating temperature 0C to +40C
Relative humidity 0% to 95% (Non-condensing)
Altitude (above sea level) 1000m without derating
Battery
Type VRLA (vented lead-acid)
Battery configuration 1 3 7 .2 Ah 1 4 9 Ah 1 6 9 Ah
Charging current 1.5A 6A 1.5A 6A 1.5A 6A 8A 8A
Recharge time 3h to 90% (only 13 kVA B) External battery dependent
Communications
User interface LCD
Communication cards SNMP (option), AS400 Relay card (option)
Standards
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Performance IEC/EN 62040-3
Manufacturing ISO 9001:2008, ISO14001:2004, OHSAS18001
Weight, dimensions
Weight 16.2kg 8.4kg 19.7kg 9.3kg 28.6kg 13.0kg 20.1kg 28.1kg
Dimensions whd 43886.5 43886.5 43886.5 438 129 438215.5
436mm 436mm 608mm 594mm 594mm
Battery modules
Weight 22.2kg 27.5kg 40.5kg 48.4kg 62.5kg
Dimensions whd 43886.5 43886.5 43886.5 438 129 438 129
436mm 436mm 608mm 594mm 594mm
The PowerValue11/31T UPS delivers reliable power, low Three-phase or single-phase inputs can also be accommodated,
running costs, long battery life, easy maintenance and high as well as single- or dual-supply inputs allowing the customer
levels of flexibility. Featuring double-conversion, voltage and to manage two independent power sources. Simple to install
frequency independent (VFI) topology, the PowerValue11/31T and with a small footprint, the PowerValue11/31T provides
is available in both 10 and 20kVA versions, with the option to stable, regulated, transientfree, pure sine wave AC power with
configure up to four units in parallel to boost power capability extremely tight output voltage regulation.
or provide redundancy.
Up Up
+
to to
4
UPSs in
parallel
2
battery
cabinets in
parallel
Frequency conversion
Operating as a frequency converter, PowerValue11/31T The operation and installation is simple and consisys merely
not only converts the power supply frequency (50Hz to/from of correctly wiring the UPS and selecting the frequency
60Hz), but it also protects the load from power disturbances conversion mode in the LCD.
and guarantees additional battery power in case of mains Input frequency range: 4070Hz
failure. Output frequency: 50Hz or 60Hz
Output derating:
Single-phase input: 60%
Three-phase input: no derating
10 11 10 11
12 12
9 9 9 9
2
1
3
8 8
4 14
7 7
15
6 6
5 5
13 13
Parallel isolator
Batteries
Maintenance
bypass switch
Battery fuses
PowerScale is an online, double-conversion, VFI (voltage with uncompromised system reliability and power availability.
frequency independent) UPS that provides enhanced power PowerScale is available in three cabinet sizes, enabling you
protection in a compact format. Its outstanding price/ to choose the ideal capacity and required autonomy for your
performance delivers the best value for money in its category critical load.
Cooling fan
Maintenance
bypass isolator
PowerWave 33, an online double conversion UPS, delivers The PowerWave 33 is available over a model range of 60kW
continuous power availability to network-critical infrastructures to 500kW and can be configured to operate as a single,
of both data centers and process control environments. standalone UPS or as a multi-cabinet UPS system with up to
Offering maximum power protection, the PowerWave 33 ten UPS cabinets connected in parallel, achieving a total
has a small footprint and uses less energy than comparable power capacity of up to 5MW.
products thus delivering significant savings.
Critical load
As your power requirements grow, the UPS system grows with them
thanks to its scalability even in the most confined spaces.
Optionally a top cable entry enclosure may be used for the Battery runtime can be optimized to match the exact needs.
400500kW UPS. This enclosure permits the connection of all The UPS supports usage of 4248 batteries (60120kW units)
incoming power cables from the top and extends the overall or 4450 batteries (160500kW units) in a single string, which
width of the UPS by 500mm. minimizes the total cost of installation as an optimal configuration
can be used and so there is no need to oversize the battery.
ABB offers a line of battery cabinets for its modular and 1. Choose the UPS power and type (pages1453)
standalone UPS series. These battery cabinets with 2. Define the backup time required
integral overcurrent protection are compatible with a wide 3. Choose common or separate batteries
range of battery configurations and are optimized to meet (in case of modular UPS)
application runtime needs. 4. Check autonomy tables for appropriate battery
configuration and compatible battery cabinets (pages 5759)
Appropriate battery sizing will ensure that the autonomy is of 5. Check technical specification of selected battery cabinets for
an adequate duration for the load supplied. The user should further information (pages 5456)
first decide what battery autonomy is required, then select the
battery configuration and cabinets accordingly. This document
assists in this process, which may be broken down into the
following steps:
Availabel models
Type CBAT-DPA-120 C CBAT-DPA-120 S CBAT-DPA-200 C CBAT-DPA-200 S
Compatible UPS models Conceptpower DPA150kVA Conceptpower DPA150kVA
Conceptpower DPA 250kVA Conceptpower DPA 250kVA
Battery quantity/type/ Up to 120 VRLA 24/28Ah Up to 200 VRLA 24/28Ah
capacity
Autonomy Depends on UPS rated power, see detailed autonomy tables (pages 5759)
Battery arrangement Common (C) Separate (S) Common (C) Separate (S)
common/separate
Dimensions whd 7301975796mm 12001975796mm
Color Front (doors) RAL9007; side walls graphite grey (similar to RAL7024)
Available models
Type CBAT-DPA UPSCALE-120C CBAT-DPA UPSCALE-120S CBAT-DPA UPSCALE-200C CBAT-DPA UPSCALE-200S
Compatible UPS models DPA UPScale ST40* | DPA UPScale ST80 DPA UPScale ST40* | DPA UPScale ST80
DPA UPScale ST60* | DPA UPScale ST120 DPA UPScale ST60* | DPA UPScale ST120 |
DPA UPScale ST200
PowerWave 33 S2160kW | PowerWave 33 S2 200kW
Battery quantity/type/ Up to120VRLA 24/28Ah Up to 200VRLA 24/28Ah
capacity
Autonomy Depends on UPS rated power, see detailed autonomy tables (pages 5759)
Battery arrangement Common (C) Separate (S) Common (C) Separate (S)
common/separate
Dimensions whd 7301975796mm 12001975796mm
Color Graphite grey (similar to RAL7024)
Available models
Type CBAT-DPA UPSCALE-600S CBAT-FLEX** CBAT-POWERSCALE-88
Compatible UPS models DPA UPScale ST120 DPA UPScale ST40* PowerScale 25kVA CabC*
DPA UPScale ST80 PowerScale 30kVA CabC*
DPA UPScale ST60* PowerScale 40kVA CabC*
DPA UPScale ST120 PowerScale 50kVA CabC*
PowerWave 33 S2160kW
PowerWave 33 S2 200kW
PowerWave 33 S2 250kW
PowerWave 33 S2 300kW
Battery type & capacity Up to 600VRLA 7/9Ah VRLA up to150Ah VRLA up to 88 24/28Ah
Autonomy Depends on UPS rated Not applicable Depends on UPS rated
power, see detailed power, see detailed
autonomy tables below autonomy tables below
Battery arrangement Separate (S) Not applicable Common (C)
common/separate
Dimensions whd 12001975796mm 4751400940mm
Color Graphite grey (similar to RAL7024)
Battery configurations are for example purposes only and calculations are based
on an ambient temperature of 20C to 25C. ABB recommends that the user checks
or recalculates configurations according to the battery manufacturers datasheet.
Cabinet B
Load power in kW/Autonomy in minutes
5min. 6min. 8min. 10min. 12min. 15min. 20min. 25min. 30min. 40min. 60min.
9kW internal internal internal internal internal internal internal internal internal internal 140
bat. bat. bat. bat. bat. bat. bat. bat. bat. bat. 28Ah
13.5kW internal internal internal internal internal internal internal 136 138 146 236
bat. bat. bat. bat. bat. bat. bat. 28Ah 28Ah 28Ah 28Ah
18kW internal internal internal internal internal internal 144 144 148 244 244
bat. bat. bat. bat. bat. bat. 28Ah* 28Ah* 28Ah 28Ah* 28Ah*
22.5kW internal internal internal internal 148 148 148 n.a. n.a. n.a. n.a.
bat. bat. bat. bat. 28Ah* 28Ah* 28Ah*
Cabinet C
Load power in kW/Autonomy in minutes
5min. 6min. 8min. 10min. 12min. 15min. 20min. 25min. 30min. 40min. 60min.
22.5kW internal internal internal internal internal internal internal n.a. n.a. n.a. n.a.
bat. bat. bat. bat. bat. bat. bat.
27kW internal internal internal internal internal internal 228 232 238 n.a. n.a.
bat. bat. bat. bat. bat. bat. 28Ah 28Ah 28Ah
36kW internal internal internal internal 236 236 236 242 n.a. n.a. n.a.
bat. bat. bat. bat. 28Ah* 28Ah* 28Ah 28Ah
45kW internal internal n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a.
bat. bat.
Slot format
Box format
CS141 ModBus USHA+
For interfacing UPS with the network and the ModBus RS-485 For interfacing UPS with the network with an option to
with option to connect alarms buzzers or additional relay board. connect additional environmental sensors. Available in slot
Available in slot and box formats. format only.
Slot cards are UPS powered, while cards in box format require external power.
4 relay outputs
04-0594 Profibus converter External DIN rail mount device
00-6944 Temperature sensor 25C to +100C, 0.5% 1.8m cable
04-3880 Combisensor for temperature and humidity 25C to +100C, 0.5% 1.8m cable
CS141
0% to100% RH, 5%
00-5915 Sensor manager Environmental interface
Sensor manager
0% to100% RH, 5%
00-6945 Alarm buzzer 85dB 5m cable
00-6947 Relay box 1 input contact 5m cable
1 output contact
04-3869 RCCMD license For Windows, Linux, MAC X, OS/2, UNIX,
NOVELL
RCCMD
04-0210 USHA+ network interface card Web/SNMP interface ModBus TCP Sensor connections
interface**
Network
2m cable
10% to 90% RH, 3%
Environmental
* All CS141 cards/boxes come with one free RCCMD client and a CD containing the monitoring software.
** All USHA+ cards come with RCCMD client and a CD containing the monitoring software.
SNMP SNMP
ModBus TCP ModBus TCP
Others Others
No peripherals
1 4
Peripheral options
Relay
Advanced board
04-0593
Buzzer
04-0592
LAN
SNMP
ModBus TCP
Others
CS141 Advanced
1 4
Peripheral options
ProfiBus 0101
Sensor manager ModBus
converter 1100
RS232
Relay Buzzer Temperature Temperature 00-5915 04-0594
board 04-0592 00-6944 and humidity
04-0593 04-3880
8
SMIO 2
00-6947
1
Temperature
00-5916
1 2
4NWP101485R0001_EN
Specifications subject to change without notice.