Sei sulla pagina 1di 2

2.

5 AC-DC Power supply: PR-240-CE

2.5 AC-DC Power supply: PR-240-CE

CB-1 (DC OUT) CB-2 (AC IN)


12 A DC Breaker 5 A AC Breaker
K1: AC-OFF detection
K2: Backup
ON/OFF

Fuse
(250 V HT6.3A)

Wiring change for AC


input voltage selection
(115 V /230V)

VR1,
for 24 VDC output
voltage adjustment

Jumper Wire for AC input voltage


selection (115 V/230 V) (note)

Note: For AC input voltage selection, see page 3-29 for details.

2-14
3.9 PR-240 input voltage modification

3.9 PR-240 input voltage modification


PR-240 is shipped for 220 VAC power input. Changing between 230 VAC and 115 VAC
is made as shown below. No soldering is required.

Change tap connection.


Change jumper connection

Step 1. Changing tap connection

White
Black

1
2
3
4
White Black

1
100VAC spec.

2
3
220VAC spec.

4
(default

The white wire is connected to #1 and


the black #2 in 220 VAC sets. Both
white and black wire are connected to
#1 in 115 VAC sets.
Step 2. Changing jumper connection

Red

SEL
115V

SEL
230V

Change the connection of red wire


depending on ships mains.

3-29