Torbar
Averaging pitot tubes
2 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
Compression Gland
Weld Fitting
All Models are supplied
All Models are supplied without flanged pipe fitting
D with carbon steel pipe or stud bolts and gaskets
weld fitting and stainless D as standard. These are
steel compression gland available as accessories.
as standard (other
materials available).
All models as flange rating to class 1500 ANSI. For higher pressures /
temperature consult factory.
DS/TORBAREN Rev. H 3
Torbar
Averaging pitot tubes
54 mm (2.12 in.)
4 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
Options
BSPT) NPT)
Direct mount head Direct mount separate manifold Direct mount integral manifold
DP Output Connections/Valves
DS/TORBAREN Rev. H 5
Torbar
Averaging pitot tubes
Withdrawable Types (Hot Tap) Basic Model Fluid D mm (in.) Fits Pipe Sizes mm (in.)
Models L702, H702, H712 and H812 should not be installed via
hot-tap methods into a pressurized pipe because of the L601 All 13 (0.5) 50 to 150 (2 to 6)
requirement to fit an end support. However once installed they L701 Gas / vapour 25 (1) 100 to 1800 (4 to 72)
can be inserted and withdrawn under pressure.
L701* Liquid 25 (1) 100 to 600 (4 to 24)
Threaded Fitting Low Pressure
L702** All 25 (1) 100 to 3000 (4 to 120)
With standard ball valve: 10 bar and 200 C (145 psi and 392 F)
Pressure Chamber
With standard gate valve: 10 bar and 400 C (145 psi and 752 F)
(Temperature is at valve)
Isolation Valve
Close Nipple
Weld Fitting
6 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
Close Nipple With standard ball valve: 40 bar and 200 C (580 psi and 392 F)
With standard gate valve: 40 bar and 400 C (580 psi and 752 F)
DS/TORBAREN Rev. H 7
Torbar
Averaging pitot tubes
Flanged Fitting
With standard ball valve: 100 bar and 200 C (1450 psi and 392 F)
With standard gate valve: 100 bar and 400 C (1450 psi and 752 F)
8 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
Valve Type TORBAR Valve Size Code (* is Material See Maximum Temperature at Valve
Model Below)
3
Threaded Ball L601 /4 in. 5B* 200 C (392 F)
DS/TORBAREN Rev. H 9
Torbar
Averaging pitot tubes
Accessories
54
** DM3V or DM5V options are recommended rather than 3VDM or 5VDM, as the latter do not allow isolation of the transmitter when dismantling
10 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
Stud Bolts, Nuts & Gasket 311, 411, 412, 511, Standard Materials: Stud, Bolts & Nuts: A193-B7/A 194-2H Gasket: SBG
512, H611, H711, Asbestos Free Glass/Aramid Fibre/Nitrile
H712, H811, H812
Gasket Material: 316 SS Spiral Wound SBGS
DS/TORBAREN Rev. H 11
Torbar
Averaging pitot tubes
150 83 (3.3) 95 (3.7) 102 (4) 118 (4.6) 1 in. 127 (5) 165 (6.5) 216 (8.5) 254 (10)
1
300 89 (3.5) 100 (4) 108 (4.3) 127 (5) 1 /2 in. 165 (6.5) 191 (7.5) 241 (9.5) 305 (12)
600 95 (3.7) 109 (4.3) 117 (4.6) 137 (5.4) 2 in. 178 (7) 216 (8.5) 292 (11.2) 368 (14.5)
900 106 (4.2) 122 (4.8) 146 (5.7) 156 (6.1) 3 in. 203 (8) 283 (11.1) 355 (14) 381 (15)
SO LV
DIN Class Size
12 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
Inserted
Retracted Inserted + ID + Wall + 233 (9.2)
Retracted
H702 Inserted ID + Wall + 518 (20.4)
Retracted Inserted + ID + Wall + 380 (15)
For geared retraction units (accessory GR) add 100 mm (4 in.) to above dimensions
Inserted and Retracted Lengths mm (in.) (Allows 5 % For Tolerancing)
Lengths maybe affected if Flanged End Support fitted
DS/TORBAREN Rev. H 13
Torbar
Averaging pitot tubes
0.93 Water
0.88
0.83
K Factor
0.78
0.73
0.68
Error Band: +0.4 % to 0.8 %
0.63
400000 500000 600000 700000 800000 900000 1000000 1100000
(883000) (1103750) (1324500) (1545250) (1766000) (1986755) (2207505) (2428260)
Kg/hr (lb/h)
0.84 Air
0.79
K Factor
0.74
0.69
0.64
0.59 Error Band: +0.3 % to 0.5 %
0.54
400 900 1400 1900 2400 2900 3400 3900 4400 4900 5400 5900
(880) (1985) (3090) (4195) (5300) 6400) (7505) (8610) (2870) (9710) (11920) (13025)
Kg/hr (lb/h)
Full details of the test results above and of those shown in the table below are available on request.
Test Fluid Model Size mm (in.) Serial Number Error Band
Water 123 50 (2) Test 197 +0.2 to -0.43 %
Water 301 100 (4) Test 297 +1 to -1 %
Air 401 150 (6) Test 397 +0.1 to -0.5 %
Air 402 450 (18) 20186 +0.6 to -0.5 %
Water 411 600 (24) Test 697 +0.3 to -0.4 %
14 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
TORBAR Coefficient K
Flow to DP
Liquids (Volumetric)
Model Number 2
QAx D
DP = --------------------------------
- mbar
KxAx4.6285
Pipe Size 301 601 401 402 511 512
(Internal 311 411 412 811 812 Gases (Volumetric)
diameter)
611 701 702 S Pf Q A 4.0323 2
DP = ------------------------------------ -------------------------------
mm (in.)
711 712 Tf + 273 Z KxA
1800 (72) and above 0.7476 0.7850 Liquids / Gases / Steam (Mass)
For sizes not shown above, determine K by extrapolation. Flow Q = DPx KxAx Dx4.6285 kghr
If using classical flow equations from ISO5167, multiply K by Symbols & Units
0.9091. QA = Flow (m3/h)
Copies of derivation of equations available on request. QB = Flow (Nm3/h) at 0 C, 1 atm (1.01325 bar)
DS/TORBAREN Rev. H 15
Torbar
Averaging pitot tubes
16 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
Maximum Allowable DP
Depending on the model and size of TORBAR there is a For liquid flow applications where there is a possibility of process
maximum figure of Differential Pressure above which the pulsations or intermittent excessive flow velocity, then the
TORBAR should NOT be used due to the imposition of end-support models should always be selected for pipe sizes
excessive mechanical stresses. Check the table below to ensure over 250 mm (10 in.) diameter (400 and 700 series) and 600
that the application is suitable. If the calculated DP exceeds the mm (24 in.) (500 and 800 series).
maximum shown below, then select an other appropriate model
to suit the application. For Bi-Directional configurations
(accessory code BW), use 50 % of the figures in this table.
2 50 6250 (2509)
3 75 2790 (1120)
* For models 121, 122, 123 (all sizes) Maximum DP value is 2500 mbar. (84 in.wg)
The above figures are theoretically derived and include a x10 safety factor over and above basic standards and specification.
Full theoretical data is available on request.
DS/TORBAREN Rev. H 17
Torbar
Averaging pitot tubes
7D (in plane) 3D 8D 3D
9D (out of plane)
9D (in plane) 3D
14D 8D 3D
(out of plane)
24D 4D
19D (in plane) 3D
24D (out of plane)
Elbow Installation
The TORBAR can be installed 2 diameters downstream of a
90 elbow at the exit of the elbow to give an accuracy of 3 %
to 5 %.
2D 3D
Elbow Installation
18 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
Orientation in Pipe
The TORBAR must be installed at right angles to the pipe run
and across a pipe diameter within the tolerances shown in the 5o 5o (Maximum)
diagrams opposite.
To avoid 'noisy' signal outputs, do not locate the TORBAR in a 4
pulsating flow. A vibrating pipe can also distort the output signal 8
and affect the structural limits of the TORBAR. This limitation
particularly applies to the integrally mounted transmitter option
DM3V and to the TRIBAR configuration.
For vertical pipe applications, the 'head' of the TORBAR is
repositioned to ensure that DP connections are at the same
Flow
vertical level. This is option VS. It is necessary to specify this
option when ordering the TORBAR.
It is essential that in all steam installations the entire TORBAR
head and fitting assembly are well lagged to prevent the General Orientation
formation of condensate in the TORBAR head. The TORBAR
will not function correctly with condensate in the head. Filling
tees or condensate pots should be fitted as appropriate.
Before installation or removal of a TORBAR it is imperative that
careful reference is made to the appropriate installation
instructions that are supplied with each TORBAR shipment. The
installation instructions are also available separately on request.
5 o min 5 o min
Warning. Refer to instruction manual before installing any
TORBAR flowmeter.
Horizontal Pipe Vertical Pipe
(side view) (top view)
Gases
Steam
5 o min 5 o min
Liquids
DS/TORBAREN Rev. H 19
Torbar
Averaging pitot tubes
Temperature Measurement
The TRIBAR can be supplied with an RTD element with or
Orifice Plate &
without a Transmitter. Refer to page 10, code NRTB or NRTT. Transmitter
Vortex
TRIBAR
Pressure Loss
20 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
DS/TORBAREN Rev. H 21
Torbar
Averaging pitot tubes
Overview
22 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
Specifications
Performance Specifications
Square root extraction of flow DP.
The purge sequence is programmed by a programmable
logic controller (PLC) and can be adjusted to purge once
every one minute to once every 24 hours. The length of
the purge time can be adjusted from one minute to 100
minutes.
Accuracy (including TORBAR): 3 % of reading.
Repeatability: 0.5 %.
Long term drift: <0.5 % per year.
Ambient temperature range: 0 to 40 C (32 to 104 F)
(thermostatically controlled heater is available as an
option).
LCD display: Two line showing flow/DP units and alarm.
Averaging: 0 to 60 seconds adjustable.
Optional alarm outputs: Two volt-free contacts selectable
NC/No. Rating: 1 A @ 110 V DC.
Optional totalizer: One alarm relay selectable as totaliser.
Max. pulse rate 100 pulses/min.
Physical Specifications
Enclosure; Epoxy painted steel. IP66 (NEMA 4X) rated.
Not suitable for use in hazardous area.
Weight: Approx. 25 kg (11.34 lb).
Process connections: 1/4 in. BSP Stainless steel.
Supply air connection: 1/4 in. BSP Stainless steel.
Electrical connection: by 20 mm (0.79 in.) knockouts.
Gland by customer.
Optional thermostatic internal heater available. Consult
factory.
System Requirements
Supply voltage: 100 to 240 V AC (50/60 Hz).
Current consumption: <1 Amp.
Purge gas supply: Clean and dry air or inert gas at
5 to 10 Bar g (72.5 to145 psig) pressure.
Gas consumption during purge is approximately
260 litres/min (57 gal/min).
Applicable Standards
Emissions monitoring: BS EN 14181, ISO 10780:1999,
BS ISO 14164:1994.
CE Marking: EN61000-6-2:2001, EN61000-6-4:2001,
EN61010-1:2001 Certified: 2006.
DS/TORBAREN Rev. H 23
Torbar
Averaging pitot tubes
24 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
DS/TORBAREN Rev. H 25
Torbar
Averaging pitot tubes
Threaded Connection
BSPT Process Connection 1 BSPT
NPT Process Connection 1 NPT
DP Head Configuration
Integral 3-valve manifold 2 DM3V
Integral 5-valve manifold 2 DM5V
Degreasing
Degreasing (sensor only) for Oxygen service DG
Dye Penetrant Examination
Dye Penetrant NDE of welds DP
Hydrostatic Pressure Testing
Hydrostatic Pressure Test 1 HP
Material Certificates
EN 10204 3.1 certificates for material 31B
EN 10204 3.2 certificates for material 31C
PED PED
1
Not with Type = 121
2
Only with DP Connection material = 0 (see page 24) and DP Connection Type & size = 00 (see page 25)
26 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
DS/TORBAREN Rev. H 27
Torbar
Averaging pitot tubes
28 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
DS/TORBAREN Rev. H 29
Torbar
Averaging pitot tubes
DP Head Configuration
Integral 3-valve manifold 1 DM3V
Integral 5-valve manifold 1 DM5V
Studbolting & Gaskets
Studbolting (A193/B7-A19 ) & standard gaskets SBG
Studbolting (A193/B7-A19 ) & spiral-wound SS gaskets SBGS
Degreasing
Degreasing (sensor only) for Oxygen service DG
Dye Penetrant Examination
Dye Penetrant NDE of welds DP
Hydrostatic Pressure Testing
Hydrostatic Pressure Test HP
Material Certificates
EN 10204 3.1 certificates for material 31B
EN 10204 3.2 certificates for material 31C
PED PED
1
Only with DP Connection material = 0 and DP Connection Type & size = 00
30 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
DS/TORBAREN Rev. H 31
Torbar
Averaging pitot tubes
32 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
DS/TORBAREN Rev. H 33
Torbar
Averaging pitot tubes
Optional Code
Permanent Models 300, 400 & 500 Series XXXX- XXXX- XXXX- XX- XX- XX- XXXX- XX- XX- XX- XX- XX- XXX
Threaded Connection
BSP Process Connection 5 BSPT
NPT Process Connection 5 NPT
DP Head Configuration
Direct mounting head 1 0VDM
Direct mounting head with fitted 3-valve manifold 1 3VDM
Direct mounting head with fitted 5-valve manifold 1 5VDM
3-valve assembly on " BSPTM Nipples (316/Plastic) 1 3PV4
Integral 3-valve manifold 1 DM3V
Integral 5-valve manifold 1 DM5V
PT100 sensor
Integral PT100 Sensor Neck Mounted Aluminium IP65 Head 6 NRTB
Integral PT100 Sensor Neck Mounted Aluminium IP65 Head + Tx 6 NRTT
Integral PT100 sensor neck mounted (to match the existing options),
Aluminium IP65 head (for process temp above 280 C [536 F]) NMTB
Integral PT100 sensor neck mounted (to match the existing options),
Aluminium IP65 head + Tx (for process temp above 280 C [536 F]) NMTT
Temperature Transmitter
Ex ia temperature Transmitter (with NRTT, NMTT only) 6 HZ
Flanged Standoff
Flanged Standoff (matches Flange Size & Rating and FS
Pipe Fitting selections made above) 2
2 Flanged Standoff (matches Flange Size & Rating and FE
Pipe Fitting selections made above)+ 1 Flanged End Support (316) 3
1 Flanged End Support in probe material 3 ES
Flanged Standoff supplied by customer 4 CS
Frequency Collar
Frequency Collar (with Flanged Standoff= FS, FE,CS only) 4 FC
Studbolting & Gaskets
Studbolting (A193/B7-A19 ) & standard gaskets 4 SBG
Studbolting (A193/B7-A19 ) & spiral-wound SS gaskets 4 SBGS
Duct Mounting
Duct Mounting Plate (in same material as selected for Pipe Fitting above) 5 DF
Bidirectional
Bidirectional Sensor 6 BW
Degreasing
Degreasing (sensor only) for Oxygen service DG
Dye Penetrant Examination
Dye Penetrant NDE of welds DP
Hydrostatic Pressure Testing
Hydrostatic Pressure Test HP
Material Certificates
EN 10204 3.1 certificates for material 31B
EN 10204 3.2 certificates for material 31C
PED PED
1
Only with DP Connection material = 0 and DP Connection Type & size = 00
2
311, 411, 412, 511, 512 only
3
412, 512 only
4 411, 412, 511, 512 only
5
301, 401, 402 only
6
401, 402, 411, 412, 511, 512 only
34 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
DS/TORBAREN Rev. H 35
Torbar
Averaging pitot tubes
36 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
DS/TORBAREN Rev. H 37
Torbar
Averaging pitot tubes
Optional Code
Withdrawable Models L600, L700, H600, H700 & H800 Series XXXX- XXXX- XX- XX- XX- XXXX- XX- XX- XX- XX- XX- XXX
DP Head Configuration
Direct mounting head 1 0VDM
Direct mounting head with fitted 3-valve manifold 1 3VDM
Direct mounting head with fitted 5-valve manifold 1 5VDM
3-valve assembly on in. BSPTM Nipples (316/Plastic) 1 3PV4
Integral 3-valve manifold 1 DM3V
Integral 5-valve manifold 1 DM5V
PT100 sensor
Integral PT100 Sensor Neck Mounted Aluminium IP65 Head 4 NRTB
Integral PT100 Sensor Neck Mounted Aluminium IP65 Head + Tx 4 NRTT
Integral PT100 sensor neck mounted, Aluminium IP65 head (for
process temp above 280 C [536 F]) NMTB
Integral PT100 sensor neck mounted, Aluminium IP65 head + Tx (for
process temp above 280 C [536 F]) NMTT
Temperature Transmitter
Ex ia temperature Transmitter (with NRTT, NMTT only) 6 HZ
Flanged Standoff
Flanged Standoff (matches Flange Size & Rating and Pipe Fitting selections FS
made above) 3
2 Flanged Standoff (matches Flange Size & Rating and Pipe Fitting selections FE
made above) + 1 Flanged End Support (316) 2
1 Flanged End Support in probe material 2 ES
Flanged Standoff supplied by customer 3 CS
Frequency Collar
Frequency Collar (with Flanged Standoff= FS, FE,CS only) FC
Studbolting & Gaskets
Studbolting (A193/B7-A19 ) & std gaskets 3 SBG
Studbolting (A193/B7-A19 ) & spiral wound SS gaskets 3 SBGS
Duct Mounting
Duct Mounting Plate (in same material as selected for Pipe Fitting above) DF
Bidirectional
Bidirectional Sensor 4 BW
Degreasing
Degreasing (sensor only) for Oxygen service DG
Dye Penetrant Examination
Dye Penetrant NDE of welds DP
Hydrostatic Pressure Testing
Hydrostatic Pressure Test HP
Material Certificates
EN 10204 3.1 certificates for material 31B
EN 10204 3.2 certificates for material 31C
PED PED
1
Only with DP Connection material = 0 and DP Connection Type & size = 00
2
H712, H812 only
3 H611, H711,H712, H811, H812 only
4
L701, L702, H711, H712, H811, H812 only
38 DS/TORBAREN Rev. H
Torbar
Averaging pitot tubes
Notes
DS/TORBAREN Rev. H 39
Contact us
ABB Limited
www.abb.com
Sales
Service
Software