Sei sulla pagina 1di 16

Type A Headwall: Reinforcing Schedule Calculations * If Override Option is Not Used, Leave Cell Blank

Reference shall be made to the "Concrete Headwalls for Precast Box Culverts" Standard Drawing for headwall dimensions and reinforcing data.

Precast Box Culvert: Footing & Cutoff Wall:


Span = 8.00 ft W f = 8.00 ft
Rise = 7.00 ft hf = 2.00 ft
Default Override * hcw = 2.00 ft
tbox,wall = 8.00 in
tbox,top = 8.00 in Bar Size:
tbox,bot = 8.00 in V= #5
W= #5
Wingwalls: X= #5
H = 10.50 ft Y= #5
h1 = 6.00 ft Z= #5
h2 = 6.00 ft (h2=h1)
L1 = 18.00 ft Bar Spacing:
L2 = 18.00 ft (L2=L1) v = 18.00 in
a = 3.67 ft w = 18.00 in
b = 1.25 ft x = 18.00 in
c = 3.92 ft y = 9.00 in
z = 18.00 in (z=w)
TYPE A HEADWALL REINFORCING SCHEDULE

TYPE
BAR WEIGHT BAR TYPE DIMENSIONS
NUMBER LENGTH INC.
MARK (LBS.)
A B C D
WINGWALLS
2 5'- 10''
X501 SERIES TO 220 STR. 0'-
of 13 10'- 4''
X502 4 10'- 4'' 44 STR.
Y501 54 6'- 0'' 341 1 0'- 6'' 5'- 8''

2 5'- 10''
WW501 SERIES TO 220 STR. 0'-
of 13 10'- 4''
WW502 16 17'- 8'' 295 STR.
4 5'- 11''
WW503 SERIES TO 148 STR. 5'-
of 3 17'- 8''
WW504 14 3'- 11'' 58 2 0'- 10'' 0'- 1 3/4'' 2'- 1/1'' 2'- 4 5/4''
WW505 4 20'- 7'' 86 3 2'- 5'' 4'- 4'' 17'- 8''
WW506 2 1'- 6'' 4 4 0'- 10'' 0'- 1 3/4''

FOOTING & CUTOFF WALL


V501 30 7'- 8'' 240 STR.
W501 30 7'- 8'' 240 STR.
Z501 34 8'- 2'' 290 5 3'- 7'' 1'- 2''

F501 12 6'- 11'' 87 STR.


F502 16 5'- 5'' 91 STR.
2 11'- 6'' 6'- 2 9/4''
F503 SERIES TO 215 6 1'- 9'' 1'- 9'' TO 1'-
of 7 17'- 11'' 12'- 2 3/2''
4 16'- 4''
F504 SERIES TO 524 STR. 0'-
of 7 19'- 6''
1 11'- 6'' 6'- 2 9/4''
F505 SERIES TO 26 6 1'- 9'' 1'- 9'' TO 0'-
2 12'- 6'' 7'- 7/1''
2 16'- 4''
F506 SERIES TO 70 STR. 0'-
2 16'- 10''
F507 7 5'- 11'' 44 1 3'- 8'' 2'- 4''
F508 2 9'- 0'' 19 STR.

FORESLOPE WALL
FS501 6 9'- 0'' 57 STR.
FS502 10 4'- 5'' 47 5 1'- 10'' 0'- 11''
FS503 10 4'- 11'' 52 7 1'- 10'' 0'- 11'' 2'- 5''

TOTAL 3,418
INC.

9/2''

9/2''

8 5/8''

3/4''

5 1/8''
4 7/4''

6/1''
Type B Headwall: Reinforcing Schedule Calculations * If Override Option is Not Used, Leave Cell Blank
Reference shall be made to the "Concrete Headwalls for Precast Box Culverts" Standard Drawing for headwall dimensions and reinforcing data.

Precast Box Culvert: Footing & Cutoff Wall:


Span = 10.00 ft W f = 4.75 ft
Rise = 4.00 ft hf = 1.50 ft
Default Override * hcw = 2.50 ft
tbox,wall = 10.00 in
tbox,top = 10.00 in Bar Size:
tbox,bot = 10.00 in V= #5
W= #5
Wingwalls: X= #5
H = 6.50 ft Y= #5
h1 = 4.00 ft Z= #5
h2 = 3.50 ft
L1 = 10.00 ft Bar Spacing:
L2 = 4.00 ft v = 18.00 in
a = 1.67 ft w = 18.00 in
b = 1.00 ft x = 18.00 in
c = 2.42 ft y = 18.00 in
q = 30 deg z = 18.00 in (z=w)
TYPE B HEADWALL REINFORCING SCHEDULE

TYPE
BAR WEIGHT BAR TYPE DIMENSIONS
NUMBER LENGTH INC.
MARK (LBS.)
A B C D
WINGWALLS
1 3'- 10''
X501 SERIES TO 43 STR. 0'-
of 8 6'- 4''
X502 2 6'- 4'' 14 STR.
1 3'- 4''
X503 SERIES TO 21 STR. 1'-
of 4 6'- 4''
Y501 14 4'- 0'' 60 1 0'- 6'' 3'- 8''

1 3'- 10''
WW501 SERIES TO 43 STR. 0'-
of 8 6'- 4''
WW502 6 9'- 8'' 61 STR.
2 4'- 10''
WW503 SERIES TO 31 STR. 4'-
of 2 9'- 8''
WW504 5 3'- 10'' 20 2 0'- 7'' 0'- 4/1'' 2'- 2 9/4'' 3'- 0/1''
WW505 2 12'- 4'' 26 3 2'- 5'' 2'- 4'' 9'- 8''
WW506 1 1'- 5'' 2 8 0'- 7'' 0'- 4/1''
1 3'- 4''
WW507 SERIES TO 21 STR. 1'-
of 4 6'- 4''
WW508 6 3'- 8'' 23 STR.
2 1'- 10''
WW509 SERIES TO 12 STR. 1'-
of 2 3'- 8''
WW510 2 7'- 1'' 15 3 2'- 5'' 2'- 10'' 3'- 8''

FOOTING & CUTOFF WALL


V501 18 4'- 5'' 83 STR.
W501 18 4'- 5'' 83 STR.
Z501 20 8'- 2'' 171 5 3'- 7'' 1'- 2''

F501 6 4'- 0'' 26 STR.


F502 8 3'- 2'' 27 STR.
2 17'- 1'' 14'- 3 1/4''
F503 SERIES TO 153 3 TO 1'- 5/2'' 2'- 5/4'' 0'-
of 4 19'- 7'' 17'- 9/4''
2 8'- 11''
F504 SERIES TO 86 STR. 0'-
of 4 11'- 6''
1 17'- 1'' 14'- 3 1/4''
F505 SERIES TO 37 3 TO 1'- 5/2'' 2'- 5/4'' 0'-
2 17'- 9'' 15'- 1 5/4''
1 8'- 11''
F506 SERIES TO 20 STR. 0'-
2 9'- 7''
F507 9 3'- 7'' 34 1 1'- 8'' 2'- 0''
F508 2 11'- 4'' 24 STR.

FORESLOPE WALL
FS501 4 11'- 4'' 48 STR.
FS502 13 1'- 5'' 20 5 0'- 6'' 0'- 8''
FS503 13 2'- 2'' 30 7 0'- 6'' 0'- 8'' 1'- 3''

TOTAL 1,234
INC.

3 5/8''

0/1''

3 5/8''

1 0/1''

0/1''

1 0/1''
1 0/1''

8 3/8''

8/1''

6 5/8''
Type C Headwall: Reinforcing Schedule Calculations * If Override Option is Not Used, Leave Cell Blank
Reference shall be made to the "Concrete Headwalls for Precast Box Culverts" Standard Drawing for headwall dimensions and reinforcing data.

Precast Box Culvert: Footing & Cutoff Wall:


Span = 10.00 ft W f = 8.00 ft
Rise = 7.00 ft hf = 2.00 ft
Default Override * hcw = 2.00 ft
tbox,wall = 10.00 in
tbox,top = 10.00 in Bar Size:
tbox,bot = 10.00 in V= #5
W= #5
Wingwalls: X= #5
H = 10.50 ft Y= #5
h1 = 10.50 ft Z= #5
h2 = 10.50 ft (h2=h1=H)
L1 = 18.00 ft Bar Spacing:
L2 = 18.00 ft (L2=L1) v = 18.00 in
a = 3.67 ft w = 18.00 in
b = 1.25 ft x = 18.00 in
c = 3.92 ft y = 9.00 in
z = 18.00 in (z=w)
TYPE C HEADWALL REINFORCING SCHEDULE

TYPE
BAR WEIGHT BAR TYPE DIMENSIONS
NUMBER LENGTH
MARK (LBS.)
A B C
WINGWALLS
X501 26 10'- 4'' 281 STR.
Y501 50 6'- 0'' 316 1 0'- 6'' 5'- 8''

WW501 26 10'- 4'' 281 STR.


WW502 32 17'- 8'' 590 STR.

FOOTING & CUTOFF WALL


V501 33 7'- 8'' 264 STR.
W501 33 7'- 8'' 264 STR.
Z501 33 8'- 2'' 282 5 3'- 7'' 1'- 2''

F501 28 24'- 11'' 728 STR.


F502 4 24'- 11'' 104 STR.
F503 9 6'- 1'' 58 1 3'- 8'' 2'- 6''
F504 2 11'- 4'' 24 STR.

FORESLOPE WALL
FS501 4 11'- 4'' 48 STR.
FS502 13 3'- 8'' 50 5 1'- 6'' 0'- 11''
FS503 13 4'- 5'' 60 7 1'- 6'' 0'- 11'' 2'- 3''

TOTAL 3,350