Pump Head Calculation Sheet

Service Diffenertial Head Calculation


Fluid
Pumping Temperature 107 F Flow Condition Normal
Specific Gravity 0.89 Heat Exchanger (A) 10
Viscosity 0.2 cp Heat Exchanger (B) 10
Capacity (Normal) 250 gpm Heater/Furnace 50
Overcapacity 10 % Filter 10
Rated (Rated) 275 gpm Orifice 2
Pipe Size 4
Suction Calculation Pipe Length 350
Original Equivilant Piping Factor per 100 ft 3.5
Absolute Pressure 15 psia Line Loss 12.25
Pressure at Source 70 psig Sub Total 94.25
Height (Source Bottom to Ref. Sur 23 ft
Height (Pump Inlet Flange to Ref. 3 ft Control Valve 10
Liquid Head 20 ft Contingency 10
Liquid Head 7.7056277056 psig Terminal Pressure 125
Sub Total 77.7056277056 psig Height (Terminal Discharge to Ref. 66
Height (Pump Inlet Flange to Ref. 3
Static Head 63
Pipe Size 6 in Static Head 24.2727272727
Pipe Length 80 ft Discharge Pressrue 263.522727273
Equivilant Piping Factor per 100 ft 0.48 Suction Pressure 77.3056277056
Line Loss 0.4 psi/100ft Diffenertial Pressure 186.217099567
Suction Pressure 77.3056277056 psig Diffenertial Head 483.32752809
Suction Pressure 92.3056277056 psia
Vapor Pressure 85 psia
NPSH 7.3056277056 psi
NPSH 18.9617977528 psi
psi
psi
psi
psi
psi
in
ft

psi/100ft
psi

psi
psi
psi
ft
ft
ft
psi
psi
psi
psi
ft
Overcapacity
10
20
30
10
1.1