BY PHARMA EDITOR ON NOVEMBER 20, 2016 ENGINEERING, SOP


Subscribe

OBJECTIVE
To lay down a procedure for Maintenance of Dust Collection system
SCOPE
This SOP is applicable to all Dust Collection system.
RESPONSIBILITY
Technical Supervisor / Engineer
ACCOUNTABILITY
Sr.Executive / Manager
PROCEDURE
Weekly Maintenance
Check and ensure the belts are not loose or excessive tight.
Ensure no air leakage from the rexine cloth connection from duct to system
FACEBOOK
Check the condition of the solenoid valves function according to timer settings. (10-25 sec)
Ensure no leakages from compressed air valves.
Ensure belt guard in proper position.
Clean the system with Cora cloth (Free from dust, grease, oil and foreign particles)
Check and ensure the glowing of indication lamps, replace lamps if fused
Like Page Contact Us
Ensure the doors are closing properly.
Check and ensure no noise from the blower. Be the first of your friends to like this

Put a Tick mark ( ) in Weekly Check Sheet after completion of each activity. If it is not O.K put a
cross (X) in Weekly Check Sheet indicating the reason in remarks column.
Immediately inform to the concern superior if it is not O.K (X) and take necessary corrective action
as per the advice. MEGA WALK-IN for FRESHER Life Science
Graduates From 19th to 30th November, 2016 @
Any such deviations should be maintained in the Machine History Cord along with necessary
Elico Healthcare Services, HYDERABAD
corrective action and its complaints there of.
ALKEM LABORATORIES LTD Walk-In Interviews
Monthly Maintenance on 25th & 26th November, 2016 @ Daman

Re grease the motor bearings. Walk-in Interviews for Analytical Formulation R&D
on 26th November, 2016 @ Jubilant Generics
Check the cushion foot mountings or rubber pads, replace the pads if found damage
Limited
Clean the bag filters
Micro lab Goa 21-22 November for production
Collect the dust from the collecting chamber and dispose. packing and technicians

Ensure the marking position of the dampers in supply, return and fresh air ducts as per position SUN PHARMA Walk-In Interview on 20th
November, 2016 @ INDORE
Check and tighten all the terminations in the panel.
Amneal Pharmaceuticals Walk-In Interview for
Put a Tick mark () in Monthly Check Sheet . Freshers & Experience Candidates on 21st & 23rd
Half Yearly Maintenance November, 2016 @ Ahmedabad

Check the dynamic balance of the blower by empty rotation of the blower with dial gauge, make it Walk-In Interview for Pharmacy Faculty on 21st &
22nd November, 2016 @ GLOBAL COLLEGE OF
balance if found any unbalance
PHARMACY, Hyderabad
Ensure the motor/blower pulley grooves smoothness, key tightness on the motor shaft.
Check the condition of relay
Ensure panel earthing is good LATEST NEWS

Clean the panel with air blower.


Clean the dust collector in total with vacuum cleaner.
Put a Tick mark () in Half Yearly Check Sheet.
Yearly Maintenance
Replace the filters with new filters if found any damages
Check the condition of the bearings with bearing analiser, replace the bearings if found clearance
more than 0.1mm.
Check the condition of the rexine cloth, replace the cloth if found any damage
Check the cable IR value with earth megger
New blood test could detect heart
Overhaul the motor & blower.
disease in asymptomatic patients
Put a Tick mark () in Yearly Check Sheet. October 15, 2016

Forms and Records (Annexures) Researchers have developed a blood test that may
help detect heart disease in asymptomatic
Annexure I
individuals by measuring the immune systems
Distribution response to inflammation, a symptom tied to
various age-related diseases like dementia and
Master copy Quality Assurance arthritis. In a nine-year-long study of 90 people
Controlled copies- Quality Assurance, Production, Quality Control without heart disease, the test, which spits out a
number indicating risk, was better
History Read More

Date Revision Number Reason for Revision read more

00 New SOP

Annexure I

S.No Dust Collector Number Equipments Connected

1 Fluid Energy Mill (FEM), Sifter, Drug coating


Pans

2 Rapid Mixture Grinder (RMG), Fluid Bed Drier


(FBD), Sifter, Sifter cum Multimill,

3 Compression Machine

4 Fluid Bed Drier (FBD), Rapid Mixture Grinder


(FBD), Sifter

5 Inspection Belt

6 Strip Packing Machine

7 Blister Packing Macking

8 Blister Packing Machine

ABOUT AUTHOR

PHARMA EDITOR

RELATED POSTS

NOVEMBER 20, 2016 0 NOVEMBER 20, 2016 0 NOVEMBER 20, 2016 0


MAINTENANCE OF CONDENSOR MAINTENANCE OF BOREWELL DISPOSAL OF DUST COLLECTED
WATER PUMPS/ CHILLED WATER PUMP MAKE: KSB, MODEL: UMA- FROM DUST COLLECTION
PUMPS, MAKE: BEACON C150 SYSTEM

LEAVE A REPLY

Your Comment

Your Name

Your Email

Your Website

POST COMMENT

GO BACK

RECENT POST SHARING

10 Easy Skin Secrets Dermatologists Dont Want You to


Know

Securing an orphan drug designation (Published in


PharmaTimes magazine November 2016)

Potrebbero piacerti anche