Sei sulla pagina 1di 3

Ceiling Microphone

Connector
Wiring Instructions
CM1-6W and CM1-6WS
June 2013

Biamp Systems, 9300 SW Gemini Drive, Beaverton, Oregon 97008 U.S.A. (503) 641-7287 www.biamp.com

CEILING MICROPHONE CONNECTOR WIRING INSTRUCTIONS

PHOENIX CONNECTOR WIRING INSTRUCTIONS FOR CM1-6W and CM1-6WS CEILING MICROPHONES
Step 1: Mount CM1-6W or CM1-6WS on ceiling tile using a 5/8
hole.

Step 2: Open back lid of junction box. Separate the supplied


phoenix connector (male/female).

MALE &
FEMALE
PHOENIX CONNECTORS

SLOTTED
MOUNTING
NUT
BRASS
STRAIN
RELIEF
FOR OUTER
CABLE

JBM40 PLENUM
RATED BOX
CEILING TILE
WITH 5/8
HOLE

CM1-6W

Step 3: Insert external wire through strain relief nut, then connect
the wire to the Phoenix terminal.
Recommended wire:
Belden 9451P - .124 O.D. or Belden 82761 - .116 O.D.

Step 4:
Wiring:
1 = Ground
2 = Blue (+)
3 = Yellow (-)

Step 5: Reconnect Phoenix terminals.

Step 6: Tighten down the strain relief nut to hold wire firmly in
place and close junction box lid.

585.0401.90A
2

CEILING MICROPHONE CONNECTOR WIRING INSTRUCTIONS

CABLE STAY ASSEMBLY


BEAM,
EYEBOLT OR
WALL

CABLE STAY
BARREL

CABLE

PLENUM RATED
CABLE

PLENUM RATED
BOX

Wrap the cable around a beam, eyebolt or hanger. Next, slip the cable
through the top of cable stay barrel pulling excess cable until taut.

g
CABLE

CABLE STAY
BARREL

g
PUSH PIN IN
TO RELEASE

CABLE RELEASE
PIN

To release cable, depress the cable release pin on top, to release the
loop, or on bottom, to extend cable length.