Sei sulla pagina 1di 68

Distributed by:

FIBRE OPTIC
CATALOGUE
Second Edition 2011

FIBRE OPTIC
CATALOGUE
Second Edition 2011

E-mail: info@fe.co.za

Website: www.falconelectronics.co.za

Contents
Introduction

FibreNet Fibre Optic Cables

Superlan
Heavy Duty Duct (HDD)
ADSS Short Span
ArmoTube CST
HDD/Corrugate Steel Tape (HDD/CST)
Double CST
Multimode OM1
Multimode OM2
Multimode OM3
Singlemode G.652.D
Singlemode G.655, G.656
Singlemode G655.A, B, C

4
5
6
7
8
9
10
11
12
13
14
15

FibreNet Fibre Optic


Patch Cord Cables

1 Fibre Simplex
2 Fibre Duplex Zipcord
2 Fibre Flat Twin Ruggedised
Distribution Cable
1.8mm Breakout Cable
2.8mm Breakout Cable

17
18
19
20
21
22

Fibre Connectors, Adaptors


and Patch Leads

ST Connector
ST Adaptor
SC Connector
SC Adaptor
LC Connector
LC Adaptor
Patch Leads

24
25
26
27
28
29
30

Fibre Optic Patch Panels

Fibre Optic Patch Panels

32

FibreNet Convertors

ST Converter Multimode SB-TP-110MST


SC Converter Multimode SB-TP-110MSC
ST Converter Singlemode SB-TP-110S25/ST
SC Converter Singlemode SB-TP-110S25/SC
LC Converter SB-TL-MC220L
LC (SFP) Mini-Gibic Fibre Module (SB-TL-SM311 Series)
SC 1 GB Converter Singlemode SB-TP-110S25/SC
14 Slot rack mount chassis (SB-TL-1400MC)

34
34
35
35
36
37
38
39

FibreNet Fibre Switches

SB-TP-2204

41

Fusion Splicers

Fujikura FSM60S

43

Fibre Test Equipment

Noyes M200 Handheld OTDR


Noyes SMLP5-5 Test Kit
DTX Compact OTDR
FibreNet VFL250 Visual Fault Locator

45
46
47
48

Fibre Optic Accessories

FibreNet 17 Piece Optic Toolkit


FibreNet 38 Piece Optic Toolkit
FibreNet 68 Piece Optic Toolkit
Handheld Fibre Microscope
FibreNet Dome Closures - FNA-4EDM01
FibreNet Dome Closures - FNA-4EDM02
FibreNet Dome Closures - FNA-4EDH01
FibreNet Dome Closures - FNA-4EDH02
FibreNet Dome Closures - FNA-6EH01
FibreNet Dome Closures - FNA-2EDH04

50
50
51
52
53
53
54
54
55
55

Glossary

57

Introduction
FibreNet Solutions are about quality, innovation, integration and advancing network
performance. Our product solutions help break down the barriers between various
technologies to make it easier for people to share information and create value for
their business.

We are listening to our customers and working closely with our business partners
to offer the right solutions at the right time for every customers business goals. We
specialise in delivering advanced bre solutions that help organisations manage voice,
data and video communications over a single multi-service infrastructure.

The FibreNet Labs provide the technical expertise required by the industry to help you
understand the technologies, as well as to design and deploy high level Fibre Solutions
in various environments.

The FibreNet Labs are committed to quality and therefore continue to advance the
communications industry with new products, that conforms to international standards.

SEAMLESS COMMUNICATION FROM A TRUE END-TO-END FIBRE SOLUTION


FibreNet provides the benets of a true end-to-end solution and the highest levels of
performance and reliability, which helps to deliver cutting-edge high bandwidth product
requirements for tomorrows business environment.

FibreNet Fibre Optic Cables

FibreNet Fibre Optic Cables


SuperLAN Cable
2 - 96 Fibre Construction, Central Tube with 12-fibre Bundles

PE Outer Jacket
Flexible Strength Elements
6.0mm Buffer Tube
Ripcord for Jacket Access (2)
Gel
Fibre Binder Threads
250 micron Fibres

Physical Specifications
Minimum Bend
Radius (cm)

Max. Tensile Load


(Newtons)

Maximum
Vertical Rise
(Meters)

Fiber
Count

Bundles

Buffer Tube
Diameter (mm)

Jacket
Diameter (mm)

Weight
(kg/km)

002 - 024

4.0

10.1

94

20.2

10.1

2700

800

871

026 - 048

6.0

12.1

128

24.2

12.1

2700

800

639

050 - 096

8.0

14.1

164

28.2

14.1

2700

800

499

Loaded

Unloaded Short Term Long Term

Environmental and Mechanical


Specication

Test Method

Operating Temperature

-40 to +70 C

FOTP - 3

Installation Temperature

-30 to +60C

N/A

Storage Temperature

-40 to +75 C

N/A

Crush Resistance

44 N/mm

FOTP - 4

Impact Resistance

Exceeds

FOTP - 25

Flexing

25 Cycles

FOTP - 104

Twist Bend

Exceeds

FOTP - 85

Fiber and Cable Identification


Cable Jacket - Black medium density
polyethylene with optional co-extruded color
stripes
Fibre Binder Threads and Fibers are identied
with standard color coding:
1 - Blue

5 - Slate

9 - Yellow

2 - Orange

6 - White

10 - Violet

3 - Green

7 - Red

11 - Rose

4 - Brown

8 - Black

12 - Aqua

** Delivery on high bre count 6-8 weeks and dependant on quantity ordered

FibreNet Fibre Optic Cables


Heavy Duty Duct Cable
2 - 288 Fibre Construction, Stranded Loose Tube with 12-fibre Subunits

PE Outer Jacket
Ripcord (1)
Strength Elements
Binder
Water Swellable Tape
3.0mm Gel Filled Buffer Tubes
Binder
250 micron Fibres
FRP Strength Member

Physical Specifications
Outer
Diameter in.
(mm)

Weight lbs/kft
(kg/km)

Minimum Bend
Radius in. (cm)

Max. Tensile Load lbs.


(Newtons)

Maximum
Vertical Rise
Feet (Meters)

Fibre
Count

Subunits

002 - 060

0.46 (11.6)

61 (91)

9.1 (23.2)

4.6 (11.6)

607 (2700)

180 (800)

2950 (899)

062 - 072

0.49 (12.6)

74 (110)

9.9 (25.2)

4.9 (12.6)

607 (2700)

180 (800)

2440 (744)

074 - 096

0.57 (14.6)

99 (148)

11.5 (29.2)

5.7 (14.6)

607 (2700)

180 (800)

1814 (553)

098 - 120

10

0.66 (16.7)

127 (189)

13.1 (33.4)

6.6 (16.7)

607 (2700)

180 (800)

1420 (433)

122 - 144

12

0.74 (18.8)

160 (238)

14.8 (37.6)

7.4 (18.8)

607 (2700)

180 (800)

1128 (344)

146 - 216

18

0.74 (18.8)

145 (216)

14.8 (37.6)

7.4 (18.8)

607 (2700)

180 (800)

1243 (379)

218 - 288

24

0.86 (21.8)

196 (292)

17.1 (43.6)

8.6 (21.8)

607 (2700)

180 (800)

919 (280)

Loaded

Unloaded

Environmental and Mechanical


Specication

Test Method

Operating Temperature

-40 to 158 F (-40 to +70 C)

FOTP - 3

Installation Temperature

-22 to 140 F (-30 to +60C)

N/A

Storage Temperature

-40 to 167 F (-40 to +75 C)

N/A

Crush Resistance

250 lbf/in (44 N/mm)

FOTP - 41

Impact Resistance

Exceeds

FOTP - 25

Flexing

25 Cycles

FOTP - 104

Twist Bend

Exceeds

FOTP - 85

Cable Identification
Cable Jacket - Black medium density
polyethylene with optional co-extruded color
stripes
Buffer Tubes and Fibres are identied with
standard color coding:
1 - Blue

5 - Slate

9 - Yellow

2 - Orange

6 - White

10 - Violet

3 - Green

7 - Red

11 - Rose

4 - Brown

8 - Black

12 - Aqua

Buffer tubes 13 thru 24 repeat the color


sequence with tracer stripe: e.g. Buffer Tube 13
is blue with tracer stripe.
** Delivery on High Fibre Count 4-6 weeks i.e. 96F-288F

Short Term

Long Term

FibreNet Fibre Optic Cables


All-Dielectric Self Supporting ADSS Cable
2 - 60 Fibre Construction, Stranded Loose Tube with 12-fibre Subunits
SHORT SPANS of up to 249 meters

PE Outer Jacket
Aramid Strength Elements
Ripcord (1)
Binder
Water Swellable Tape
3.0 mm Gel Filled Buffer Tubes
Binder
250 micron Fibres
FRP Strength Member

Physical Specifications
Fibre Count

Maximum # of Fibres
Per Tube

Subunits

Outer Diameter
in. (mm)

Weight lbs/kft
(kg/km)

002 - 060

12

0.46 (11.8)

66 (99)

Minimum Bend Radius in. (cm)


Loaded

Unloaded

9.3 (23.6)

4.6 (11.8)

Sag and Tension Examples


Heavy
Fibre Count
002 - 060

Medium

Max Span ft (m)

Total Sag at NESC


Loading (%)

Max Span ft (m)

374 (114)

5.04

594 (181)

Light

Total Sag at NESC


Max Span ft (m)
Loading (%)
4.62

Total Sag at NESC


Loading (%)

817 (249)

4.18

Values were calculated at 21 C with a 1.5% installation sag

Environmental and Mechanical


Specication

Test Method

Operating Temperature

-40 to 158 F (-40 to +70 C) FOTP - 3

Installation Temperature

-22 to 140 F (-30 to +60C)

N/A

Storage Temperature

-40 to 167 F (-40 to +75 C)

N/A

Crush Resistance

250 lbf/in (44 N/mm)

FOTP - 41

Impact Resistance

Exceeds

FOTP - 25

Flexing

25 Cycles

FOTP - 104

Twist Bend

Exceeds

FOTP - 85

High Frequency (Aeolian) Vibration

100 Million Cycles

IEEE 1222

Low Frequency (Galloping) Vibration

100,000 Cycles

IEEE 1222

Electrical Space Potential - Standard Jacket

up to 12 kV

IEEE 1222

Electrical Space Potential - Special AT Jacket up to 25 kV

IEEE 1222

Cable Identification
Cable Jacket - Black polyethylene with optional
coextruded color stripes
Buffer Tubes and Fibres are identied with
standard color coding:
1 - Blue

5 - Slate

9 - Yellow

2 - Orange

6 - White

10 - Violet

3 - Green

7 - Red

11 - Rose

4 - Brown

8 - Black

12 - Aqua

FibreNet Fibre Optic Cables


ArmoTube Cable
2 - 96 Fibre Construction, Central Tube with 12-fibre Bundles

PE Outer Jacket
Steel Armor
Ripcord for Jacket Access (2)
6.0mm Buffer Tube
Ripcord for Armor Access (2)
Gel
Fiber Binder Threads
250 micron Fibres

Physical Specifications
Fibre
Count

Buffer Tube
Bundles Diameter in.
(mm)

Jacket
Diameter
in. (mm)

Weight lbs/
kft (kg/km)

Minimum Bend Radius


in. (cm)
Loaded

Max. Tensile Load lbs.


(Newtons)

Unloaded

Short Term

Long Term

Maximum
Vertical Rise
Feet (Meters)

002 - 024

0.16 (4.0)

0.43 (11.0)

93 (138)

8.6 (22.0)

4.3 (11.0)

607 (2700)

180 (800)

1945 (593)

026 - 048

0.24 (6.0)

0.51 (13.0)

121 (181)

10.2 (26.0)

5.1 (13.0)

607 (2700)

180 (800)

1483 (452)

050 - 096

0.31 (8.0)

0.59 (15.0)

152 (226)

11.8 (30.0)

5.9 (15.0)

607 (2700)

180 (800)

1188 (362)

Environmental and Mechanical


Specication

Test Method

Operating Temperature

-40 to 158 F (-40 to +70 C)

FOTP - 3

Installation Temperature

-22 to 140 F (-30 to +60C)

N/A

Storage Temperature

-40 to 167 F (-40 to +75 C)

N/A

Crush Resistance

250 lbf/in (44 N/mm)

FOTP - 41

Impact Resistance

Exceeds

FOTP - 25

Flexing

25 Cycles

FOTP - 104

Twist Bend

Exceeds

FOTP - 85

Cable Identification
Cable Jacket - Black medium density
polyethylene with optional co-extruded color
stripes
Fibre Binder Threads and Fibres are identied
with standard color coding:
1 - Blue

5 - Slate

9 - Yellow

2 - Orange

6 - White

10 - Violet

3 - Green

7 - Red

11 - Rose

4 - Brown

8 - Black

12 - Aqua

** Delivery on High Fibre Count 6-8 weeks i.e. 26F-96F also dependant on quantity ordered

FibreNet Fibre Optic Cables


Corrugate Steel Tape (CST) Cable
2 - 288 Fibre Construction, Stranded Loose Tube with 12-fibre Subunits

PE Outer Jacket
Steel Tape Armoring
Water Blocking Tape
PE Inner Jacket
Ripcord (2)
Strength Elements
Binder
Water Blocking Tape
Ripcord (1)
Binder
3.0mm Gel Filled Buffer Tubes
250 micron Fibres
Dielectric Strength Member

Physical Specifications
Outer
Diameter in.
(mm)

Weight lbs/kft
(kg/km)

0.64 (16.2)

0.67 (17.1)

074 - 096

098 - 120

10

122 - 144

Fibre
Count

Subunits

002 - 060
062 - 072

Minimum Bend Radius in.


(cm)

Max. Tensile Load lbs.


(Newtons)

Maximum
Vertical Rise
Feet (Meters)

Loaded

Unloaded

Short Term

Long Term

152 (227)

12.7 (32.4)

6.4 (16.2)

607 (2700)

180 (800)

1183 (361)

172 (256)

13.4 (34.2)

6.7 (17.1)

607 (2700)

180 (800)

1049 (320)

0.75 (19.2)

209 (312)

15.1 (38.4)

7.5 (19.2)

607 (2700)

180 (800)

860 (262)

0.84 (21.3)

252 (376)

16.7 (42.6)

8.4 (21.3)

607 (2700)

180 (800)

714 (218)

12

0.92 (23.4)

296 (442)

18.4 (46.8)

9.2 (23.4)

607 (2700)

180 (800)

607 (185)

146 - 216

18

0.92 (23.4)

282 (420)

18.4 (46.8)

9.2 (23.4)

607 (2700)

180 (800)

639 (195)

218 - 288

24

1.04 (26.4)

350 (522)

20.7 (52.8)

10.4 (26.4)

607 (2700)

180 (800)

514 (157)

Environmental and Mechanical


Specication

Test Method

Operating Temperature

-40 to 158 F (-40 to +70 C) FOTP - 3

Installation Temperature

-22 to 140 F (-30 to +60C)

N/A

Storage Temperature

-40 to 167 F (-40 to +75 C)

N/A

Crush Resistance

250 lbf/in (44 N/mm)

FOTP - 41

Impact Resistance

Exceeds

FOTP - 25

Flexing

25 Cycles

FOTP - 104

Twist Bend

Exceeds

FOTP - 85

Cable Identification
Cable Jacket - Black medium density
polyethylene with optional co-extruded color
stripes
Buffer Tubes and Fibres are identied with
standard color coding:
1 - Blue

5 - Slate

9 - Yellow

2 - Orange

6 - White

10 - Violet

3 - Green

7 - Red

11 - Rose

4 - Brown

8 - Black

12 - Aqua

Buffer tubes 13 thru 24 repeat the color


sequence with tracer stripe: e.g. Buffer Tube 13
is blue with tracer stripe.
** Delivery on High Fibre Count 6-8 weeks i.e. 96F-288F also dependant on quantity ordered

FibreNet Fibre Optic Cables


Double Corrugate Steel Tape(CST) Cable
2 - 288 Fibre Construction, Stranded Loose Tube with 12-fibre Subunits

PE Outer Jacket
Steel Tape Armoring
Water Blocking Tape
PE Inner Jacket
Steel Tape Armoring
Ripcord (2)
Water Blocking Tape
PE Inner Jacket
Strength Elements
Binder
Ripcord (2)
Binder
Water Blocking Tape
Ripcord (1)
3.0mm Gel Filled Buffer Tubes
FRP Strength Member
250 micron Fibres

Physical Specifications
Outer
Diameter in.
(mm)

Weight lbs/
kft (kg/km)

0.81 (20.7)

0.85 (21.7)

074 - 096

098 - 120

Minimum Bend Radius in.


(cm)

Max. Tensile Load lbs.


(Newtons)

Loaded

Unloaded

Short Term

Long Term

Maximum
Vertical Rise
Feet (Meters)

272 (406)

16.2 (41.4)

8.1 (20.7)

607 (2700)

180 (800)

661 (202)

298 (444)

17.0 (43.4)

8.5 (21.7)

607 (2700)

180 (800)

605 (184)

0.93 (23.8)

348 (519)

18.7 (47.6)

9.3 (23.8)

607 (2700)

180 (800)

517 (158)

10

1.02 (25.9)

405 (604)

20.3 (51.8)

10.2 (25.9)

607 (2700)

180 (800)

444 (135)

122 - 144

12

1.09 (27.9)

462 (689)

21.9 (55.8)

10.9 (27.9)

607 (2700)

180 (800)

390 (119)

146 - 216

18

1.09 (27.9)

447 (667)

21.9 (55.8)

10.9 (27.9)

607 (2700)

180 (800)

402 (123)

218 - 288

24

1.21 (30.9)

534 (796)

24.3 (61.8)

12.1 (30.9)

607 (2700)

180 (800)

337 (103)

Fibre
Count

Subunits

002 - 060
062 - 072

Environmental and Mechanical


Specication

Test Method

Operating Temperature

-40 to 158 F (-40 to +70 C) FOTP - 3

Installation Temperature

-22 to 140 F (-30 to +60C)

Storage Temperature

-40 to 167 F (-40 to +75 C)

N/A

Crush Resistance

250 lbf/in (44 N/mm)

FOTP - 41

Impact Resistance

Exceeds

FOTP - 25

Flexing

25 Cycles

FOTP - 104

Twist Bend

Exceeds

FOTP - 85

N/A

Cable Identification
Cable Jacket - Black medium density
polyethylene with optional co-extruded color
stripes
Buffer Tubes and Fibres are identied with
standard color coding:
1 - Blue

5 - Slate

9 - Yellow

2 - Orange

6 - White

10 - Violet

3 - Green

7 - Red

11 - Rose

4 - Brown

8 - Black

12 - Aqua

Buffer tubes 13 thru 24 repeat the color


sequence with tracer stripe: e.g. Buffer Tube 13
is blue with tracer stripe.
** Delivery on High Fibre Count 6-8 weeks i.e. 26F-96F also dependant on quantity ordered

10

FibreNet Fibre Optic Cables


Multimode Fibre OM1
62.5/125 Micron

Coating

Cladding

Core

Physical Characteristics
Core Diameter

62.5 2.5 m

Cladding Diameter

125.0 1.0 m

Core/Clad Offset

1.0 m

Coating Diameter (Uncolored)

245 10 m

Coating Diameter (Colored)

254 7 m

Coating/Cladding Concentricity Error, max

8 m

Clad Non-Circularity

1%

Mechanical Characteristics
Proof Test

100 kpsi (.69 Gpa)

Coating Strip Force

0.3 - 2.0 lbf (1.3 - 8.9 N)

Dynamic Fatigue Parameter (nd)

18

Macrobending (100 turns @ 75mm mandrel)

0.5 dB max. @ 850 nm and 1300 nm

Standards Compliance: TIA 492AAAA (OM1)

Optical Characteristics, Wavelength Specific


Max. Attenuation, Loose Tube Cable

850-nm

1300-nm

3.0 dB/km

1.0 dB/km

Max Attenuation, Tight Buffer Cable

3.4 dB/km

1.0 dB/km

Bandwidth, OFL, min.

220 MHz-km

500 MHz-km

Group Refractive Index

1.496

1.491

1 Gb Ethernet Distance

300 m

550 m

Optical Characteristics, General


Numerical Aperature

0.275 0.015

Point Defects,max

0.15 dB

Zero Dispersion Wavelength

1320 - 1365 nm

Zero Dispersion Slope, max.

0.097 ps/[km-nm-nm]

Environmental Characteristics
Temperature Dependence -60 C to +85 C

0.2 dB

Temperature Humidity Cycling -10 C to +85 C


up to 95% RH

0.2 dB

Water Immersion, 23+2 C

0.2 dB

Heat Aging, 85 + 2 C

0.2 dB

11

FibreNet Fibre Optic Cables


Multimode Fibre OM2
50/125 Micron

Coating

Cladding

Core

Physical Characteristics
Core Diameter

50.0 2.5 m

Cladding Diameter

125.0 1.0 m

Core/Clad Offset

1.5 m

Coating Diameter (Uncolored)

245 10 m

Coating Diameter (Colored)

254 7 m

Coating/Cladding Concentricity Error, max

6 m

Clad Non-Circularity

1%

Mechanical Characteristics
Proof Test

100 kpsi (.69 Gpa)

Coating Strip Force

0.3 - 2.0 lbf (1.3 - 8.9 N)

Dynamic Fatigue Parameter (nd)

18

Macrobending (100 turns @ 75mm mandrel)

0.5 dB max. @ 850 nm and 1300 nm

Standards Compliance: TIA 492AAAB (OM2)

Optical Characteristics, Wavelength Specific


850-nm

1300-nm

Max. Attenuation, Loose


Tube Cable

3.0 dB/km

1.0 dB/km

Max Attenuation, Tight Buffer


Cable

3.0 dB/km

1.0 dB/km

Bandwidth, OFL, min.

700 MHz-km

500 MHz-km

Bandwidth, Laser, min.

950 MHz-km

500 MHz-km

Differential Mode Delay, max.

0.70 ps/m

0.88 ps/m

Group Refractive Index

1.483

1.479

1 Gb Ethernet Distance

800 m

600 m

10 Gb Ethernet Distance

150 m

Optical Characteristics, General


Numerical Aperature

0.275 0.015

Point Defects,max

0.15 dB

Zero Dispersion Wavelength

1320 - 1365 nm

Zero Dispersion Slope, max.

0.097 ps/[km-nm-nm]

Environmental Characteristics
Temperature Dependence -60 C to +85 C

0.2 dB

Temperature Humidity Cycling -10 C to +85 C


up to 95% RH

0.2 dB

Water Immersion, 23+2 C

0.2 dB

Heat Aging, 85 + 2 C

0.2 dB

12

FibreNet Fibre Optic Cables


Multimode Fibre OM3
50/125 Micron

Coating

Cladding

Core

Physical Characteristics
Core Diameter

50.05 2.5 m

Cladding Diameter

125.0 1.0 m

Core/Clad Offset

1.5 m

Coating Diameter (Uncolored)

245 10 m

Coating Diameter (Colored)

254 7 m

Coating/Cladding Concentricity Error, max

3 m

Clad Non-Circularity

1%

Mechanical Characteristics
Proof Test

100 kpsi (.69 Gpa)

Coating Strip Force

0.3 - 2.0 lbf (1.3 - 8.9 N)

Dynamic Fatigue Parameter (nd)

18

Macrobending (100 turns @ 75mm mandrel)

0.5 dB max. @ 850 nm and 1300 nm

Standards Compliance: TIA 492AAAC (OM3)

Optical Characteristics, Wavelength Specific


850-nm

1300-nm

Max. Attenuation, Loose


Tube Cable

3.0 dB/km

1.0 dB/km

Max Attenuation, Tight Buffer


Cable

3.0 dB/km

1.0 dB/km

Bandwidth, OFL, min.

1500 MHz-km

500 MHz-km

Bandwidth, Laser, min.

2000 MHz-km

500 MHz-km

Differential Mode Delay, max.

Superior to TIA-492AAAC
and IEC 60793-2-10

0.88 ps/m

Group Refractive Index

1.483

1.479

1 Gb Ethernet Distance

1020 m

600 m

10 Gb Ethernet Distance

300 m

Optical Characteristics, General


Numerical Aperature

0.200 0.015

Point Defects,max

0.15 dB

Zero Dispersion Wavelength

1297 - 1316 nm

Zero Dispersion Slope, max.

0.105 ps/[km-nm-nm]

Environmental Characteristics
Temperature Dependence -60 C to +85 C

0.10 dB

Temperature Humidity Cycling -10 C to +85 C


up to 95% RH

0.10 dB

Water Immersion, 23+2 C

0.20 dB

Heat Aging, 85 + 2 C

0.20 dB

13

FibreNet Fibre Optic Cables


Singlemode Fibre G.652.D
ITU-T G.652.D (9/125)

Coating

Cladding

Core

Physical Characteristics
Cladding Diameter

125.0 0.7 m

Core/Clad Offset

0.5 m

Coating Diameter (Uncolored)

245 10 m

Coating Diameter (Colored)

254 7 m

Coating/Cladding Concentricity Error, max

12 m

Clad Non-Circularity

1%

Mechanical Characteristics
Proof Test

100 kpsi (.69 Gpa)

Coating Strip Force

0.3 - 2.0 lbf (1.3 - 8.9 N)

Fibre Curl

4m

Dynamic Fatigue Parameter (nd)

20

Macrobending (100 turns @ 75mm mandrel)

0.05 dB (1310/1550nm @ 50mm)


0.05 dB (1625nm @ 60 mm)

Macrobending, max. (1 turn @ 32 mm


mandrel)

0.05 dB @ 1550 nm

Optical Characteristics, Wavelength Specific


1310-nm

1385-nm

1550-nm

Max. Attenuation, Loose Tube


Cable

0.35 dB/km

0.32 dB/km

0.25 dB/km

Max Attenuation, Tight Buffer


Cable

0.50 dB/km

0.50 dB/km

0.50 dB/km

Mode Field Diameter

9.2 0.3 m

9.6 0.6 m

10.4 0.5 m

Group Refractive Index

1.468

1.468

1.467

Dispersion, max.

3.2 ps/(nm-km) from


1285 to 1330 nm

Optical Characteristics, General


Point Defects, max.

0.10 dB

Cutoff Wavelength

1260

Zero Dispersion Wavelength

1302 - 1322 nm

Zero Dispersion Slope, max.

0.090 ps/[km-nm-nm]

Polarization Mode Dispersion Link Design Value

0.06 ps/sqrt(km)

Environmental Characteristics
Temperature Dependence -60 C to +85 C

0.05 dB

Temperature Humidity Cycling -10 C to +85 C


up to 95% RH

0.05 dB

Water Immersion, 23+2 C

0.05 dB

Heat Aging, 85 + 2 C

0.05 dB

18 ps/(nm-km)

14

FibreNet Fibre Optic Cables


Singlemode Fibre G.655, 656
ITU-T G.655, 656 (9/125)

Coating

Core

Cladding

Physical Characteristics
Cladding Diameter

125.0 0.7 m

Core/Clad Offset

0.5 m

Coating Diameter (Uncolored)

245 5 m

Coating Diameter (Colored)

257 m to 264 m

Coating/Cladding Concentricity Error, max

12 m

Clad Non-Circularity

0.7%

Mechanical Characteristics
Proof Test

100 kpsi (.69 Gpa)

Coating Strip Force

0.3 - 2.0 lbf (1.3 - 8.9 N)

Fibre Curl

4m

Dynamic Fatigue Parameter (nd)

20

Macrobending (100 turns @ 75mm mandrel)

0.05 dB max. @ 1550 & 1625 nm

Macrobending, max. (1 turn @ 32 mm


mandrel)

0.50 dB max. @ 1550 & 1625 nm

Optical Characteristics, Wavelength Specific


1310-nm

1550-nm

1625-nm

Max. Attenuation, Loose Tube


Cable

0.45 dB/km

0.25 dB/km

0.34 dB/km

Max Attenuation, Tight Buffer


Cable

N/A

N/A

N/A

8.6 0.4 m

9.1 0.6 m

1.470

1.470

5.5 to 8.9 ps/


(nm-km) from
1530 - 1565 nm

6.9 to 11.4 ps/


(nm-km) from
1565 - 1625 nm

Mode Field Diameter


Group Refractive Index

1.471

Dispersion

Optical Characteristics, General


Attenuation at 1385-nm

0.45 dB/km

Point Defects

0.10 dB

Cutoff Wavelength

1310

Dispersion Slope

< 0.045 ps/[km-nm-nm] at 1550-nm

Polarization Mode Dispersion Link Design Value

0.1 ps/sqrt(km)

Environmental Characteristics
Temperature Dependence -60 C to +85 C

0.05 dB

Temperature Humidity Cycling -10 C to +85 C


up to 95% RH

0.05 dB

Water Immersion, 23+2 C

0.05 dB

Heat Aging, 85 + 2 C

0.05 dB

15

FibreNet Fibre Optic Cables


Singlemode Fibre G.655
ITU-T G.655.A,B,C (9/125)

Coating

Core

Cladding

Physical Characteristics
Cladding Diameter

125.0 0.7 m

Core/Clad Offset

0.5 m

Coating Diameter (Uncolored)

245 5 m

Coating Diameter (Colored)

256 8 m

Coating/Cladding Concentricity Error, max

12 m

Clad Non-Circularity

1%

Mechanical Characteristics
Proof Test

100 kpsi (.69 Gpa)

Coating Strip Force

0.3 - 2.0 lbf (1.3 - 8.9 N)

Fibre Curl

4m

Dynamic Fatigue Parameter (nd)

20

Macrobending (100 turns @ 75mm mandrel)

0.05 dB max. @ 1550 & 1625 nm

Macrobending, max. (1 turn @ 32 mm


mandrel)

0.50 dB max. @ 1550 & 1625 nm

Optical Characteristics, Wavelength Specific


1310-nm

1550-nm

1625-nm

Max. Attenuation, Loose Tube


Cable

0.45 dB/km

0.25 dB/km

0.34 dB/km

Max Attenuation, Tight Buffer


Cable

N/A

N/A

N/A

8.4 0.6 m

8.9 0.6 m

1.471

1.470

1.470

-8 ps/(nm-km)
(typical)

2.6 to 6 ps/(nmkm) from 1530


- 1565 nm

4.0 to 8.9 ps/(nmkm) from 1565


- 1625 nm

Mode Field Diameter


Group Refractive Index
Dispersion

Optical Characteristics, General


Attenuation at 1385-nm

1.0 dB/km

Point Defects

0.10 dB

Cutoff Wavelength

1260

Dispersion Slope

< 0.05 ps/[km-nm-nm] at 1550-nm

Polarization Mode Dispersion Link Design Value

0.1 ps/sqrt(km)

Environmental Characteristics
Temperature Dependence -60 C to +85 C

0.05 dB

Temperature Humidity Cycling -10 C to +85 C


up to 95% RH

0.05 dB

Water Immersion, 23+2 C

0.05 dB

Heat Aging, 85 + 2 C

0.05 dB

16

FibreNet Fibre Optic Patch Cord Cables

17

FibreNet Fibre Optic Patch Cord Cables


1 Fibre Simplex Cable

Outer Jacket

Aramid Yarn

900 m Tight Buffer

250 m Optical Fibre

Physical Specifications
Fiber
Count

Outer Diameter
in. (mm)

Weight Ibs/
kft (kg/km)

Minimum Bend Radius in.


(cm)
Loaded

Max. Tensile Load Ibs.


(Newtons)

Unloaded

Short Term

0.067

(1.70)

2.0

(3.0)

2.0

(5.0)

1.2

(3.0)

35

(156)

11

(47)

1,640

(500)

0.114

(2.90)

6.8

(10.1)

2.3

(5.8)

1.2

(3.0)

60

(267)

18

(80)

1,640

(500)

Environmental and Mechanical


Specication

Test Method

Operating Temperature

-4F to +158F (-20C to +70C)

FOTP-3

Installation Temperature

32F to +158F (OC to +700C)

N/A

Storage Temperature

-40F to +158F (-40C to +70C)

Crush Resistance

Exceeds 571bf/in (10 N/mm)

FOTP - 41

Impact Resistance

Exceeds 0.54Ibf-ft (0.74 N-m)

FOTP - 25

Flexing

Exceeds 300 cycles

FOTP -104

Twist Bend

Exceeds

FOTP - 85

Fiber and Cable Identification


Standard Jacket Color (according to ber type)
50 m OM3 - AQ for Aqua
50 m OM2 - OR for Orange
62.5 m - OR for Orange
Singlemode - YL for Yellow
other colors available upon request
Fibers are identied with Standard color coding:
1 - Blue

N/A

Long Term

Maximum Vertical Rise


Feet (Meters)

18

FibreNet Fibre Optic Patch Cord Cables


2 Fiber Zipcord Cable

Outer Jacket

Aramid Yarn

900 m Tight Buffer

250 m Optical Fibre

Physical Specifications
Fibre
Count

Outer Diameter x
Width in. (mm)

Weight Ibs/kft
(kg/km)

Minimum Bend Radius


in. (cm)
Loaded

Max. Tensile Load Ibs.


(Newtons)

Maximum Vertical
Rise Feet (Meters)

Unloaded

Short Term

Long Term

0.067 x 0.1 38

1.70 x 3.50

4.0

(6.0)

2.0

(5.0)

1.2

(3.0)

70

(311)

21

(93)

1,640

(500)

0.114 x 0.232

2.90 x 5.90

13.6

(20.2)

2.3

(5.8)

1.2

(3 .0)

90

(400)

27

(120)

1,640

(500)

Environmental and Mechanical


Specication

Test Method

Operating Temperature

-4F to +158F (-20C to +70C)

FOTP- 3

Installation Temperature

32F to +158F (OC to + 70C)

N/A

Siorage Temperature

-40F to +158F (-40C to +70C)

N/A

Crush Resistance

Exceeds 57 Ibin (10 N/mm)

FOTP - 41

Impact Resistance

Exceeds 0.54 Ibf-It (0.74 N-m)

FOTP - 25

Flexing

Exceeds 300 cycles

FOTP - 104

Twist Bend

Exceeds

FOTP - 85

Fiber and Cable Identification


Standard Jacket Color (according to ber type)
50 m OM3 - AQ for Aqua
50 m OM2 - OR for Orange
62.5 m - OR for Orange
Singlemode - YL for Yellow
other colors available upon request
Fibers are identied with Standard color coding:
1 - Blue
2 - Orange

19

FibreNet Fibre Optic Patch Cord Cables


Flat Twin Ruggedised
2 Fibre Duplex

Outer Jacket

Ripcord
Aramid Yarn
900 m Tight Buffer

250 m Optical Fibre

Physical Specifications
Fibre
Count

Nominal Subunit
Diameter in.
(mm)

Outer Diameter x
Width in. (mm)

Weight lbs/
kft (kg/km)

Minimum Bend Radius


in. (cm)
Loaded

1.70

0.067

0.101 x
0.168

2.90

0.114

0.148 x
0.262

Unloaded

8.7

(12.9)

2.0

(5.1)

1.2

(3.0)

60

(267)

18

(80)

1,640

(500)

3.76 x
6.66

21.1

(31.4)

3.0

(7.5)

1.5

(3.8)

90

(400)

27

(120)

1,281

(391)

Specication

Test Method

Operating Temperature

-4F to +158F (-20C to +70C)

FOTP - 3

Installation Temperature

32F to +158F (0C to +70C)

N/A

Storage Temperature

-40F to +158F (-40C to +70C)

N/A

Crush Resistance

Exceeds 57 lbf/in (10 N/mm)

FOTP - 41

Impact Resistance

Exceeds 0.54 lbf-ft (0.74 N-m)

FOTP - 25

Flexing

Exceeds 300 cycles

FOTP - 104

Twist Bend

Exceeds

FOTP - 85

Fibre and Cable Identification


Standard Jacket Color (according to bre type)
50 m (OM3 M ) AQ for Aqua
50 m Black
Singlemode YL for Yellow
other colors available upon request
Fibers are identied with Standard color coding:
2 - Orange

Short Term Long Term

Maximum
Vertical Rise
Feet (Meters)

2.57 x
4.27

Environmental and Mechanical

1 - Blue

Max. Tensile Load lbs.


(Newtons)

20

FibreNet Fibre Optic Patch Cord Cables


Distribution Cable
2 - 24 Fibre

Outer Jacket
Ripcord

Aramid Yarn

900 m Tight Buffer

250 m Optical Fibre

Physical Specifications
Fibre Outer Diameter
Count
in. (mm)

Weight lbs/
kft (kg/km)

Minimum Bend Radius in. (cm)


Loaded

Unloaded

Max. Tensile Load lbs. (Newtons)


Short Term

Long Term

Maximum Vertical
Rise Feet (Meters)

0.15

(3.9)

8.8

(13.1)

3.1

(7.8)

1.5

(3.9)

225

(1,001)

68

(300)

1,640

(500)

0.17

(4.4)

12.2

(18.2)

3.4

(8.7)

1.7

(4.4)

300

(1,335)

90

(400)

1,640

(500)

0.19

(4.8)

15.1

(22.5)

3.8

(9.7)

1.9

(4.8)

300

(1,335)

90

(400)

1,640

(500)

0.20

(5.1)

16.8

(24.9)

4.0

(10.2)

2.0

(5.1)

300

(1,335)

90

(400)

1,640

(500)

12

0.23

(5.8)

20.8

(30.9)

4.6

(11.7)

2.3

(5.8)

300

(1,335)

90

(400)

1,640

(500)

18

0.31

(7.9)

40.9

(60.9)

6.2

(15.8)

3.1

(7.9)

300

(1,335)

90

(400)

1,640

(500)

24

0.33

(8.5)

47.3

(70.4)

6.7

(16.9)

3.3

(8.5)

300

(1,335)

90

(400)

1,640

(500)

Composite Cable with multiple ber types: See information above for requested total ber count

Environmental and Mechanical


Operating Temperature

Specication

Test Method

-4F to +158F (-20C to +70C)

FOTP - 3

Installation Temperature

32F to +158F (0C to +70C)

N/A

Storage Temperature

-40F to +158F (-40C to +70C)

N/A

Crush Resistance

Exceeds 57 lbf/in (10 N/mm)

FOTP - 41

Impact Resistance

Exceeds 4.34 lbf-ft (5.88 N-m)

FOTP - 25

Flexing

Exceeds 100 cycles

FOTP - 104

Twist Bend

Exceeds

FOTP - 85

Fiber and Cable Identification


Standard Jacket Color (according to ber type)
50 m (OM3) AQ for Aqua
50 m (OM2) & 62.5 m (OM1) OR for Orange
Singlemode (OS1) - YL for Yellow
other colors available upon request
Fibers are identied with Standard color coding:
1 - Blue

5 - Slate

9 - Yellow

2 - Orange

6 - White

10 - Violet

3 - Green

7 - Red

11 - Rose

4 - Brown

8 - Black

12 - Aqua

Fibres 13 thru 24 repeat the sequence with tracer


stripe: e.g. bre 13 is blue with tracer stripe.

21

FibreNet Fibre Optic Patch Cord Cables


Breakout Cable (1.8mm)
2 - 24 Fibre

Outer Jacket
Ripcord

Simplex Subunit
Simplex Cable Diameter = 1.80 mm
Outer Jacket
Aramid Yarn
900 m Tight
Buffer

Central Strength
Member

250 m
Optical
Fibre

Physical Specifications
Fibre
Count

Outer Diameter
in. (mm)

Minimum Bend Radius

Weight lbs/kft
(kg/km)

Loaded

Unloaded

Max. Tensile Load


Short Term

Long Term

Maximum
Vertical Rise

0.21

(5.4)

18

(26)

4.3

(10.9)

2.1

(5.4)

120

(534)

36

(160)

1,640

(500)

0.26

(6.7)

34

(51)

5.3

(13.4)

2.6

(6.7)

150

(667)

45

(200)

1,316

(401)

0.31

(7.9)

48

(72)

6.2

(15.9)

3.1

(7.9)

300

(1,335)

90

(400)

1,640

(500)

12

0.39

(9.9)

78

(116)

7.8

(19.9)

3.9

(9.9)

300

(1,335)

90

(400)

1,151

(351)

18

0.39

(9.9)

70

(104)

7.8

(19.8)

3.9

(9.9)

600

(2,670)

180

(801)

1,640

(500)

24

0.46

(11.6)

96

(143)

9.1

(23.1)

4.6

(11.6)

600

(2,670)

180

(801)

1,640

(500)

Environmental and Mechanical


Specication

Test Method

Operating Temperature

-4F to +158F (-20C to +70C)

FOTP - 3

Installation Temperature

32F to +158F (0C to +70C)

N/A

Storage Temperature

-40F to +158F (-40C to +70C)

N/A

Crush Resistance

Exceeds 57 lbf/in (10 N/mm)

FOTP - 41

Impact Resistance

Exceeds 4.34 lbf-ft (5.88 N-m)

FOTP - 25

Flexing

Exceeds 100 cycles

FOTP - 104

Twist Bend

Exceeds

FOTP - 85

Fibre and Cable Identification


Standard Jacket Color (according to bre type)
50 m (OM3) AQ for Aqua
50 m (OM2) OR for Orange
Singlemode YL for Yellow
other colors available upon request
Fibres are identied with Standard color coding:
1 - Blue

22

FibreNet Fibre Optic Patch Cord Cables


Breakout Cable (2.8mm)
4 - 24 Fibre

Outer Jacket

Ripcord

Simplex Subunit
Simplex Cable Diameter = 2.80 mm
Outer Jacket
Central Strength
Member

Aramid Yarn
900 m Tight
Buffer
250 m
Optical
Fibre

Physical Specifications
Fibre
Count

Outer Diameter
in. (mm)

0.32

6
8

Minimum Bend Radius

Weight lbs/kft
(kg/km)

(8.1)

47

0.38

(9.7)

0.45

(11.5)

12

0.50

18
24

Loaded

Max. Tensile Load

Unloaded

Maximum
Vertical Rise

Short Term

Long Term

(8.1)

300

(1,335)

90

(400)

1,640

(500)

(69)

6.4

(16.2)

3.2

61

(91)

7.6

(19.3)

3.8

(9.7)

500

(2,225)

150

(667)

1,640

(500)

78

(116)

9.0

(23.0)

4.5

(11.5)

600

(2,670)

180

(801)

1,640

(500)

(12.8)

102

(152)

10.0

(25.5)

5.0

(12.8)

600

(2,670)

180

(801)

1,640

(500)

0.57

(14.4)

137

(203)

11.3

(28.8)

5.7

(14.4)

600

(2,670)

180

(801)

1,241

(378)

0.64

(16.2)

173

(257)

12.8

(32.5)

6.4

(16.2)

600

(2,670)

180

(801)

986

(301)

Environmental and Mechanical


Operating Temperature

Specication

Test Method

-4F to +158F (-20C to +70C)

FOTP - 3

Installation Temperature

32F to +158F (0C to +70C)

N/A

Storage Temperature

-40F to +158F (-40C to +70C)

N/A

Crush Resistance

Exceeds 57 lbf/in (10 N/mm)

FOTP - 41

Impact Resistance

Exceeds 4.34 lbf-ft (5.88 N-m)

FOTP - 25

Flexing

Exceeds 100 cycles

FOTP - 104

Twist Bend

Exceeds

FOTP - 85

Fibre and Cable Identification


Standard Jacket Color (according to bre type)
50 m (OM3) AQ for Aqua
50 m (OM2) OR for Orange
Singlemode YL for Yellow
other colors available upon request
Fibres are identied with Standard color coding:
1 - Blue

23

Fibre Connectors & Adaptors

24

Fibre Connectors & Adaptors


ST Connector

Utilize a bayonet style mating concept to provide a secure, robust coupling mechanism.
The enclosed spiral slotted coupling nut allows easy insertion in densely packed patch
panels. The ST connector has been used extensively in telecom, data and premise
installation applications and could easily be considered a de facto standard.

Classification

Arrangement

conguration: bayonet
coupling: twist lock

pigtail/patch cord

Style
Variant

accept various cable sizes


accept various bre sizes
2.5mm zirconia ferrule

No

bre retention: adhesive (epoxy)


cable retention: crimp
optical coupling: physical contact
alignment: resilient bushing

Description

Material

ST 3.00mm Boot

PP + TPR(UL94V-0)

Crimp 3.00mm

Al

ST C-Ring

Stainless

ST Nut

Zn Alloy

Spring

Stainless

ST Flange

Zn Alloy

2
1

SM Ferrule PC

Ceramic

MM Ferrule PC

Ceramic

Dust Cap

PE

25

Fibre Connectors & Adaptors


ST Adaptor

1. General Information
1.1 Purpose This specication describes the ST type ber optic adaptor for connector
with ST/PC patch cord.
1.2 Effectivity This specication is effective upon release.
1.3 Applicable documents.
1.3.1 The ST* type ber optical adaptor is fully compliant with IEC 60874-10-3
Fibre optic adaptor type BFOC/2,5 for single and multimode bre.

2. ST/PC Adaptor Construction


2.1 ST/PC adaptor material
Adaptor housing
Sleeve
Dust cap
Dust cap color

Zinc Die casting, nickel-plated


ZrO2/Ceramic
PVC
Black/Yellow

2.2 ST/PC adaptor optical characteristics


Increase in insertion loss
After 500 mating
Maximum insertion loss

0.15dB
0.2dB

2.3 Mechanical characteristic


Retention force

200~600gf

3. Adaptor Test and Requirements


3.1 Adaptors are factory tested visual and mechanical examination.
3.2 Insertion loss and retention force are 100% factory tested.
Insertion loss
Retention force

0.2dB
200~600gf

3.3 Temperature ranges and humidity


Operating temperature
Humidity (NON-Condensing)

-40C- +80C
95% R.H.

26

Fibre Connectors & Adaptors


SC Connector

Outline side view of SC 900m Connector

Utilize a push pull retention feature enabling easy insertion and removal, making it
ideally suited for high density.
The SC connector features an internal cavity that virtually eliminates the possibility of
improper epoxy application, thus providing higher manufacturing yields.

Classification

Arrangement

conguration: plug-adaptor-plug
coupling: push pull

pigtail/patch cord

Style
Variant

accept various cable sizes


accept various bre sizes
2.5mm zirconia ferrule

bre retention: adhesive (epoxy)


cable retention: crimp
optical coupling: physical contact
alignment: resilient bushing

No

Description

Material

10

FC & SC 3.0mm Boot

PP + TPR(UL94V-0)

Ring/Tube

Al/Polyolen

FC/SC 3.0mm Crimp

Al

Holder

Cu-Ni

Flange

Cu-Ni

Spring

Stainless

Plug-Frame

PBT

SM Ferrule PC

Ceramic

MM Ferrule PC

Ceramic

Housing

PBT

Dust Cap

PE

27

Fibre Connectors & Adaptors


SC Adaptor
SC Simplex SM Adaptor

SC Duplex MM Adaptor

1.

General Information

1.1 Purpose This specication describes the SC type ber


optic adaptor for connector with SC/PC patch cord.
1.2 Effectivity This specication is effective upon release.
1.3 Applicable documents.
1.3.1 Telcordia GR-326-CORE generic requirements
for single mode optical connectors and jumper
assemblies.
1.3.2 JIS C5973-1998 F04 (SC) type connector for
optical ber cords.
1.3.3 IEC 60874-14 (1993) Sectional specication for
bre optic connector Type SC.

2.

SC/PC Adaptor Construction

2.1 SC/PC adaptor material


Hook
Alignment sleeve
Adaptor housing
Plate
Cap
Melting temperature
for plastic parts

Plastic PBT 30%G.F. lled blue or grey,


UL94 V-0
Phosphor-Bronze or Zirconia
Plastic PBT 30% G.F. led blue or gray,
UL94 V-0
SUS 304 Stainless steel
Plastic ABS UL94 V-0
1) Adaptor hook, hosing : 210 - 220
(Heat deection temperature)
2) Cap: 180 - 190
(Heat deection temperature)

Note: The melting temperature is higher than heat deection


temperature.

2.1 SC/PC adaptor optical characteristics


Increase in insertion loss

0.15dB

After 500 mating


Maximum insertion loss

0.2dB

2.1.3 Mechanical characteristic


Retention Force

200~600gf

3. Adaptor Test and Requirements


3.1 Adaptors are factory tested visual and mechanical
examination.
3.2 Insertion loss and retention force are 100% factory
tested for all adaptors according to IEC 874-1 standard
(method 7) and CECC 86000(method 7)
Insertion loss

0.2dB

Retention force

200~600gf

3.3 Temperature ranges and humidity


Operating temperature

-40 - +80

Humidity (NON-Condensing)

95% R.H.

28

Fibre Connectors & Adaptors


LC Connector

These connectors utilize the familiar RJ-45 style latching mechanism. As a small form
factor (SFF) connector, the LC connector is almost half the size of the popular SC
connector. With accelerated growth demanding greater bandwidth in less physical
space, LC connectors have emerged as a viable solution for high density frames and
patch panels.

Classification

Arrangement

conguration: plug-adaptor-plug / plug


socket
coupling: push pull

pigtail/patch cord

Variant

small form factor


accept various cable sizes
accept various bre sizes
1.25mm zirconia ferrule

Style

bre retention: adhesive (epoxy)


cable retention: crimp
optical coupling: physical contact
alignment: resilient bushing

Table-1 Material and Colour

Part

Material

Colour

-1
-2

PP
Engineering Plastic
Zirconia

White
Blue (for SM)/Beige (for MM)
N/A

Teon
Alluminium +H/S
TPR
Nylon

N/A
White
White (for SM)/Grey (for MM)
Blue (for SM)/Beige (for MM)

Housing
Ferrule
Tubing L=17mm)

-3
-4
-5

Table-2 Specications of the LC Ferrule

Mode
d
c
D

Single Mode

Multi Mode

0.1255 +0.001/-0
0.0010
1.249 0.0005

0.126 +0.003/-0
0.0040
1.249 0.001

29

Fibre Connectors & Adaptors


LC Adaptor

1.

General Information

1.1 Purpose This specication describes the LC (SC type)


ber optic adaptor for connector with LC/PC patch cord.
1.2 Effectivity This specication is effective upon release.
1.3 Applicable documents.
1.3.1 Telcordia GR-326-CORE generic requirements
1.3.2 JIS C5973-1998 LC (SC type) connector for
optical ber cords.
1.3.3 IEC 60874 Sectional specication for bre optic
connector Type LC.

2.

LC/PC Adaptor Construction

2.1 LC/PC adaptor material

2.1 LC/PC adaptor optical characteristics


Increase in insertion loss

0.15dB

After 500 mating


Maximum insertion loss

0.2dB

2.1.3 Mechanical characteristic


Retention Force

200~600gf

3. Adaptor Test and Requirements


3.1 Adaptors are factory tested visual and mechanical
examination.
3.2 Insertion loss and retention force are 100% factory
tested for all adaptors according to IEC 874-1 standard
(method 7) and CECC 86000(method 7)

Hook

Plastic PBT 30%G.F. lled blue or grey,


UL94 V-0

Alignment sleeve

Phosphor-Bronze or Zirconia

Insertion loss

0.2dB

Adaptor housing

Plastic PBT 30% G.F. led blue or gray,


UL94 V-0

Retention force

200~600gf

Plate

SUS 304 Stainless steel

3.3 Temperature ranges and humidity

Cap

Plastic ABS UL94 V-0

Operating temperature

-40 - +80

Melting temperature
for plastic parts

1) Adaptor hook, hosing : 210 - 220

Humidity (NON-Condensing)

95% R.H.

(Heat deection temperature)


2) Cap: 180 - 190
(Heat deection temperature)

Note: The melting temperature is higher than heat deection


temperature.

30

Patch Leads
Key Features
A complete line of cable assemblies for virtually any Networking, Storage or Data
Center Infrastructure
Connects between equipment and different interfaces
Plant Assembled and tested
Usable in 50/125, 62.5/125 and 10/125 (Singlemode) applications
Most standard connector styles include FCPC, MTRJ, LC, SC, ST, APC and MPO

31

Fibre Optic Patch Panels

32

Fibre Optic Patch Panels

The FibreNet patch panel is constructed from four pieces: two adjustable mounting
brackets, lid, main wrap or box with adaptor bracket (SC/LC only)
All parts are made from Mild Steel and are powder coated Vep 8406 Ferro grain
The FibreNet panel is adjustable by 56mm, allowing you to recess the enclosure as
needed
It is 1U in height, ts on standard 19 inch racks
The Fibre panel has provision for six glands
2-piece sliding
The FibreNet ber optic patch panel is rack mountable and ideal for managing and
routing ber patch cables in the datacenter

FC/ST 24Port Faceplate

LC/SC 24Port Faceplate

SC 24Port Duplex Faceplate

33

FibreNet Convertors

34

FibreNet Convertors
10/100Base-TX to 100Base-FX
FE Media Converter
ST Multimode
SB-TP-110MST
ST connector multimode
Provide one ST ber connecter and one UTP connector.
Extend ber distance up to 2km for multi-mode ber.

10/100Base-TX to 100Base-FX
FE Media Converter
SC Multimode
SB-TP-110MSC
SC connector multimode
Provide one SC ber connecter and one UTP connector.
Extend ber distance up to 2km for multi-mode ber.

Key Features

LFP (Link Fault Pass-through) Function


Power from External Power Adapter
ST/SC connector multimode
DIP Switch to set congurations
Supports packet length up to 1536 bytes
RoHS Compliance
Complies with 802.3u 10/100Base-TX and 100Base-FX standard.
Provide one ST ber connecter and one UTP connector.
Auto-detection of half/full duplex transfer mode for TX port.
Auto-negotiation of 10/100Mbps rate and Auto-Crossover for TX port.
Provide switch conguration of half/full duplex transfer mode for FX port.
Extend ber distance up to 2km for multi-mode ber.
Easy to view LED indicators provide status to monitor network activity easily.

Technical Specifications
Standard

IEEE 802.3/IEEE 802.3u

Connector

1 ST ber optic: 1 RJ45 jack

Max Distance

Twisted pair (cat5): 100m


Multi-mode ber optic: 2km
20/40/60/80/120km

Data Transfer Rate

100Mbps:148,800 pps
10Mbps:14,880 pps

Buffer Memory

128K

Power:

Input

220V AC,48V DC

Output

5V DC 1A

Temperature

Operation:

-10 to 50

Storage:

- 40 to 70

Humidity

10% - 90% (non-condensing)

Dimensions:

External power

94mm x 70mm x 26mm (L x W x H)

Outside power

140mm x 110mm x 30mm (L x W x H)

35

FibreNet Convertors
FibreNet 10/100Base-TX to ST Converter
ST Singlemode
SB-TP-110S25/ST
SC connector singlemode
Provide one SC ber connecter and one UTP connector.
Extend ber distance up to 20-120km for single-Mode ber.

FibreNet 10/100Base-TX to SC Converter


SC Singlemode
SB-TP-110S25/SC
SC connector singlemode
Provide one SC ber connecter and one UTP connector.
Extend ber distance up to 2km for multi-Mode ber and
20-120km for single-Mode ber.

Key Features

LFP (Link Fault Pass-through) Function


Power from External Power Adapter
ST connector singlemode
DIP Switch to set congurations
Supports packet length up to 1536 bytes
RoHS Compliance
Complies with 802.3u 10/100Base-TX and 100Base-FX standard.
Provide one SC ber connecter and one UTP connector.
Auto-detection of half/full duplex transfer mode for TX port.
Auto-negotiation of 10/100Mbps rate and Auto-Crossover for TX port.
Provide switch conguration of half/full duplex transfer mode for FX port.
Extend ber distance up to 2km for multi-Mode ber and 20-120km for singleMode ber.
Easy-to-view LED indicators provide status to monitor network activity easily.

Technical Specifications
Standard

IEEE 802.3/IEEE 802.3u

Connector

1 ST ber optic: 1 RJ45 jack

Max Distance

Twisted pair (cat5): 100m


Multi-mode ber optic: 2km
20/40/60/80/120km

Data Transfer Rate

100Mbps:148,800 pps
10Mbps:14,880 pps

Buffer Memory

128K

Power:

Input

220V AC,48V DC

Output

5V DC 1A

Temperature

Operation:

-10 to 50

Storage:

- 40 to 70

Humidity

10% - 90% (non-condensing)

Dimensions:

External power

94mm x 70mm x 26mm (L x W x H)

Outside power

140mm x 110mm x 30mm (L x W x H)

36

FibreNet Convertors
LC Converter. 1000Mbs
LC Multimode/Singlemode
SB-TL-MC220L

Product Features
Works at 1000Mbps in Full-Duplex mode for both TX port and FX port
Supports auto MID/MID-X for TX port
Link Fault Pass through and Far End Fault minimize the loss caused by link
failure timely
Provides switch conguration of Force /Auto transfer mode for FX port
FX port support hot-swappable
Extends ber distance up to 0.55km for multi-mode ber and 10km for singlemode ber
Easy-to-view LED indicators provide status to monitor network activity easily
External power supply

Product Specifications
Standards and Protocols

IEEE 802.3ab, IEEE 802.3z, IEEE 802.3x


Full Duplex Flow Control (IEEE 802.3x)
Extends ber distance up to 0.5km using 50/125um ber,
0.22km using 62.5/125um ber)

Basic Function

Link Fault Pass through and Far End Fault minimize the
loss caused by link failure timely
1 Gigabit SFP Slot
Ports
1 1000M RJ45 port (Auto MDI/MDIX)
1000BASE-T
Network Media
1000BASEFX

UTP category 5, 5e cable (maximum 100m)


EIA/TIA-568 100 STP (maximum 100m)
Multi-mode Fiber

LED Indicators

PWR, LINK, RX

Safety & Emission

FCC, CE

Dimensions (W*D*H)

3.7*2.9*1.1 in. (94.5*73.0*27.0 mm)


Operating Temperature: 0 C ~40 C (32 F~104 F)
Storage Temperature: -40 C~70 C (-40 F ~158 F)

Environment

Operating Humidity: 10%~90% non-condensing


Storage Humidity: 5%~90% non-condensing
Power Supply

External Power Adapter

More information of the 1000M series Media Converter


Model NO.

Interface

SB-TLMC200CM

RJ45--SC

SB-TLMC210CS

RJ45--SC

SB-TL-MC220L

RJ45--LC/SC

Transmission
Distance

Transmission
Media

Output Center
Wavelength

0.55km (50/125um),

Multimode
Fiber,TP

850nm

15km

Single mode
Fiber,TP

1310nm

0.55km /10km

Multi/Single
mode Fiber, TP

850nm/1310nm

0.22km (62.5/125um)

37

FibreNet Convertors
LC (SFP) Mini-Gibic Fibre Module
LC Singlemode
SB-TL-SM311 Series

Product Features

Support Full-Duplex
Plug-and-Play
LED indicators show the operation state of the ber module
Supports Pull-or-Plug with power on switches
Power: internal power from switches

Product Specifications
Single mode
Standards and Protocols

IEEE 802.3z, CSMA/CD, TCP/IP

Cable

Single mode Fiber

Fiber Type

9/125 um Single mode

Max. Cable Length

10km

Data Rate

1.25Gbps

Port Type

LC

Wave Length

1310nm

Power Support

3.3V

Safety & Emission

FCC, CE

Environment

Operating Temperature: 0 C~70 C (32 F ~158 F)


Storage Temperature: -40 C ~80 C (-40 F ~176 F)
Operating Humidity: 10%~90% non-condensing
Storage Humidity: 5%~90% non-condensing

Multimode
Standards and Protocols

IEEE 802.3z, CSMA/CD, TCP/IP

Cable

Multi-mode Fiber

Fiber Type

50/125um or 62.5/125um Multi-mode

Max. Cable Length

550m

Data Rate

1.25Gbps

Port Type

LC

Wave Length

850nm

Power Support

3.3V

Safety & Emission

FCC, CE

Environment

Operating Temperature: 0 C ~70 C (32 F ~158 F)


Storage Temperature: -40 C ~80 C (-40 F ~176 F)
Operating Humidity: 10%~90% non-condensing
Storage Humidity: 5%~90% non-condensing

38

FibreNet Convertors
SC 1 GB Converter Singlemode. 1000Base-Tx
Ethernet (UTP) - 1 Port 1000Base-Fx (FO) SMF
SC Singlemode
SB-TP-110S25/SC

SC connector singlemode
Provide one SC ber connecter and one UTP connector.
Extend ber distance up to 2km for multi-Mode ber and
20-120km for single-Mode ber.

Key Features

LFP (Link Fault Pass-through) Function


Power from External Power Adapter
ST connector singlemode
DIP Switch to set congurations
Supports packet length up to 1536 bytes
RoHS Compliance
Complies with 802.3u 10/100Base-TX and 100Base-FX standard.
Provide one SC ber connecter and one UTP connector.
Auto-detection of half/full duplex transfer mode for TX port.
Auto-negotiation of 10/100Mbps rate and Auto-Crossover for TX port.
Provide switch conguration of half/full duplex transfer mode for FX port.
Extend ber distance up to 2km for multi-Mode ber and 20-120km for singleMode ber.
Easy-to-view LED indicators provide status to monitor network activity easily.

Technical Specifications
Standard

IEEE 802.3/IEEE 802.3u

Connector

1 ST ber optic: 1 RJ45 jack

Max Distance

Twisted pair (cat5): 100m


Multi-mode ber optic: 2km
20/40/60/80/120km

Data Transfer Rate

100Mbps:148,800 pps
10Mbps:14,880 pps

Buffer Memory

128K

Power:

Input

220V AC,48V DC

Output

5V DC 1A

Temperature

Operation:

-10 to 50

Storage:

- 40 to 70

Humidity

10% - 90% (non-condensing)

Dimensions:

External power

94mm x 70mm x 26mm (L x W x H)

Outside power

140mm x 110mm x 30mm (L x W x H)

39

FibreNet Convertors
14 Slot rack mount chassis
SB-TL-1400MC

Product Features

14 bays to house up to 14 media converters


Standard 19-inch rack-mountable with, 2U height
Optional redundant power supply to ensure non-stop reliable operation
Provides hot-swapping of media converters and redundant power supplies
Two cooling fans (internal) mounted at the rear panel for system cooling
Media converter power isolation for electrical isolation from each bay
Offers over-voltage and over-current protections

Product Specifications
AC Power Supply

Input: 100-240V~50/60Hz 3.0A(Max)


Output:+9.5VDC, 9.5A(Max)
Vripple: 50mv
Noise: 100mv

Operating Temperature

0C~40C (32F~104F)

Storage Temperature

-40C~70C (-40F~158F)

Operating Humidity

10%~90% non-condensing

Storage Humidity

5%~90% non-condensing

Dimensions (W*D*H)

19.0*14.1*3.4in.(482*358*86)
Standard 19-Inch, 2U height

Weight

8Kg

40

FibreNet Fibre Switches

41

FibreNet Fibre Switches


FibreNet 2 x 10/100/1000M RJ45+
2 x 1000M SFP Port
SB-TP-2204

SB-TP-2204 4 port Gigabit Ethernet Switch with two 10/100/1000M UTP ports and two
1000M SFP sockets. The end users can use different SFP module according to his
requirement, for example: 1000Base-T, 1000Base-SX, 1000Base-LX etc. The product
is possessed of stable performance, excellent quality and reasonable price because of
adopting latest IC from USA and high quality of transceivers. It is applicable to use in
small patterns of Optical Fiber Ethernet.

Key features
Two RJ45 ports and two SFP sockets, it can convert Optical - Electric Ethernet
signals between 10/100/1000M UTP ports and 1000M optical ber ports and
switch Ethernet signals between port and port.
Auto negotiation function supports UTP ports to auto 10/100/1000M and Full
Duplex/Half Duplex.
Broadcast storm protection
Supports VLAN and QoS
Supports the max 1536 bytes frame
Small power consumption (3W), low heat, good stability

Technical Specifications
Operating standards

IEEE802.3z/AB
10/100/1000Base-T
1000Base-SX/LX

MAC address

1K

Frame buffer memory

512Kb RAM

Bandwidth

12 G, can be transmitted to achieve non-blocking wire-speed

Cable

UTP cable: Cat. 5 (the max distance up to 100m)

Flow control

multimode Fiber

50/125, 62.5/125m (the max distance up


to 224/550m)

singlemode Fiber

8/125, 8.7/125, 9/125, 10/125m (the max


distance up to 100km)

Full Duplex

IEEE802.3x ow control

Half Duplex

bake pressure ow control

Power

AC100 ~ 240V, 50 60Hz; DC5V 2A

Environment temperature

0 +50

Storage temperature

-20 +70

Humidity

5% 90%

Dimensions

27(h) 125(W) 85(l)mm

42

Fusion Splicers

43

Fusion Splicers
Fujikura FSM60S
Single Fibre Arc Fusion Splicer

Features

Highly durable designed for tough environments


Worlds most compact & lightest of its class
Core alignment with auto-bre identication (PAS)
9 sec. splice time & 30 sec. tube-heat time
Auto-start tube heater
Optional bre clamping methods
Splice image capture facility
Software upgrade via Internet
Includes multi-function worktable

Technical Specifications
Applicable bres

SM (ITU-T G.652), MM (ITU-T G.651), DS (ITU-T G.653), NZDS (ITU-T G.655) and other SMF
including ITU-T G.657 bres

Fibre Count

Single

Cladding diameter

80 to 150m

Coating diameter

100 to 1000m

Fibre cleaved length

8mm to 16mm using Sheath Clamp A, B or C/ 10mm using FH-60-250, FH-60-900

Actual average splice loss

0.02dB with SM, 0.01dB with MM, 0.04dB with DS, 0.04dB with NZDS

Splice time

Typical 9sec. with standard SM bre

Return loss

60dB or greater

Measured by cut-back method relevant to ITU-T standards

Splicing modes

Total number available equals 100; for pre-set modes and user programmable modes

Splice loss estimate

Several types of core deformations as well as core axis offset are taken into account for accurate
loss estimate

Attenuation splice function

Intentional high splice loss of 0.1dB to 15dB (0.01dB step) can be made for an inline xed
attenuator

Storage of splice result

The last 2000 results to be stored in the internal memory

Fibre display

X/Y, or both X and Y simultaneously

Magnication

300x for single X or Y view, or 187x for X and Y view

Viewing method

By two CMOS cameras for bre viewing and 4.1inches TFT colour LCD monitor

Image change over

The bre image is turned upside down automatically according to the monitor position

Operating condition

0-5000m above sea level, 0-95% RH and -10 to 50C respectively

Mechanical proof test

2N (standard)

Tube heater

Built-in auto-start tube heater with 10 heating modes and up to 20 for reference

Tube heat time

Typical 30sec.with FP-03 protection sleeve

Applicable protection sleeve length

60mm, 40mm and a series of micro sleeves

No. of splice/heating with battery

160 cycles with BTR-08

Power supply

Auto voltage selection from 100 to 240Va.c. or 10 to 15Vd.c. with ADC-13. 13.2Vd.c. with BTR-08

Terminals

USB1.1 (USB-Mini B) for data and video signal transfer to PC

Wind protection

Max. wind velocity of 15m/s.

Dimensions

136(W) x 161(D) x 143(H) mm

Weight

2.3kg, with ADC-13 AC Adaptor, 2.7kg, with BTR-08 Battery

44

Fibre Test Equipment

45

Fibre Test Equipment


Noyes M200 Handheld OTDR
Features

Handheld, 0.9 kg (2 lb)


22 dB (MM), 26 dB (SM) dynamic range
Integrated VFL (650 nm)
Tool-free, switchable adapters
Transective (indoor/outdoor)
touchscreen display
USB Host and Function Ports

Applications
Tier 2 testing of premises networks
FTTX PON certication and
troubleshooting
Fast fault location
Splice verication
Network documentation

Specifications
OTDR Specications
Multimode

Single-mode

Emitter Type

Laser

Safety Class

Class 1 FDA 21 CFR 1040.0 & 1040.11

Center Wavelengths

850/1300 nm

1310/1550 nm

Wavelength Tolerance

20 / 30 nm

20 / 30 nm

Dynamic Range (SNR = 1)

22 dB

26 dB

Event Dead Zone

1.5 m

1.5 m

Attenuation Dead Zone

9m

9m

Pulse Widths

10, 30, 100, 300 ns, 1, 3 s

10, 30, 100, 300 ns, 1, 3, 10 s

Range Settings

250 m to 64 km

250 m to 208 km

Data Points

Up to 16,000

Up to 16,000

Data Point Spacing

0.25 m (range < 4 km)

Range/16000 (range > 8 km)

Group Index of Refraction (GIR)

1.4000 to 1.6000

Distance Uncertainty (m)

(1 + 0.005% x distance + data point spacing)

Trace File Format

Bellcore GR-196 Version 1.1

Trace File Storage Medium

Internal, non-volatile memory and removable Compact Flash Card

Trace File Storage Capacity

> 100 internal; thousands on Compact Flash or USB Flash Drive

Trace File Transfer to PC

USB Flash Drive Type 1.1, Compact Flash or Mini USB Cable with ActiveSync

Visual Fault Locator Specications

General Specications

Emitter Type

Laser

Size (in boot)

Safety Class

Class II FDA 21 CFR 1040.10


& 1040.11; IEC 825-1:1993,
EN60825-1:1994

Weight

0.9 kg (2 lb)

Operating Temperature

-10 to +50 C

Storage Temperature

-20 to +60 C

Wavelength

650 nm

Output Power (nominal)

0.8 mw

23 x 11 x 7 cm (8.8 x 4.3 x 2.8 inches)

Relative Humidity

0 to 95% RH (non-condensing)

Power

Removable LiIon or 110/220 VAC power


adapter

Battery Life

4 6 hours

Recharge Time

4 & 5 3 hours

46

Fibre Test Equipment


Noyes SMLP5-5 Single-mode/Multimode Test Kit
Features

Handheld, rugged, lightweight


Wave ID (auto identication & switching)
Dual or single Wave ID, CW, Tone
270 Hz, 330 Hz, 1 kHz, 2 kHz Tone
Large LCD with backlight (OPM5-2D)
Power measurements in dBm or W; insertion
loss in dB
Reference power level storage
Up to 500 records per wavelength storage
USB port for download of stored records
Windows compatible software to view, print,
and archive stored records
Low battery indicator
Long battery life with 2 x AA alkaline, optional
AC adapter
Free 50 m and 62.5 m mandrels
Cost-effective, easy to use
N.I.S.T traceable

Specifications
Optical
Wavelength

MM Optical Port
850 30 nm

Output power
Output Stability

1310 20 nm

LED

Emitter type
Spectral width

SM Optical Port

1300 -10/+50 nm

1550 20 nm
Laser

Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03


40 nm (typ)

120 nm (typ)

5 nm (max)

5 nm (max)

> - 20 dBm, 62.5 m multimode*

0 dBm, 9 m single-mode

0.1 dB over 8 hours


(after 5 min. warm-up)

0.05 dB over 1 hour (after 15 min. warm-up)


0.1 dB over 8 hours (after 15 min. warm-up)

General
Power
Battery life
Available adapters

2 x AA batteries, optional AC adapter


Typical 30 hours, minimum 20 hours

Typical 72 hours, minimum 40 hours


SC FC, ST, LC

Operating temperature

-10 to 50C, 90% RH (non-condensing)

Storage temperature

-30 to 60C, 90% RH (non-condensing)

Size (H x W x D)
Weight

14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in)


0.29 kg (0.65 lb)

* Output power will be approximately 3 dB less if a 50m mandrel-wrapped jumper is used instead of a 62.5m mandrel-wrapped jumper.
All specications at 25C.

47

Fibre Test Equipment


DTX Compact OTDR
Key Specifications
Dimensions
(Mainframe with Compact
OTDR installed)

21.6 cm x 11.2 cm x 9.1 cm (8.5 in x 4.4 in


x 3.6 in) nominal

Weight
(Mainframe with DTX
Compact OTDR installed)
Display size

1.36 kg (3 lbs)
9.4 cm (3.7 in) diagonal, 240 dots wide by
320 dots high, passive

color, transmissive LCD with


backlight.
Case

High-impact plastic with shock absorbing


over mold (mainframe)

Languages supported

English, French, German, Spanish,


Portuguese, Italian, Japanese, and
Simplied Chinese

Operating temperature

0 C to 45 C (32 F to 113 F)

Non-operating temperature
(storage)

-20 C to 60 C (-4 F to 140 F)

Relative humidity

0 C to 35 C (32 F to 95 F): 0% to 90%

(% RH operating without
condensation)

35 C to 45 C (95 F to 113 F): 0% to


70%

Trace le format

LinkWare or Bellcore GR-196 V1.1

Features

Typical trace storage


capability

>200 internal, thousands on removable


MMC/SD card

Altitude (OTDR module)

Operating 3000 m; storage 12000 m

EMC

EN 61326-1

OTDR laser safety

Class I CDRH, complies to EN 60825-2

Battery pack

Removable/rechargeable 7.4 V, 4000


mAh Li Lithium-ion

Battery pack life

>8 hours

Charge time* (with tester off)

4 hours (below 40 C)

Vibration

Random, 2 g, 5-500 Hz

Shock

1 meter drop test with and without module


attached to mainframe

Safety class

Class I C , Class 1 CDRH complies to


EN60825-2

Safety

CSA C22.2 No. 1010.1: 1992, EN


61010-1 1st. edition + amendments 1, 2

Calibration

Service center calibration period is one


year

VFL specications (23 C)


Output power (into SM ber)

316 w (-5 dBm) peak power 1.0 mw


(0 dbm)

Operating wavelength

650 nm nominal

Spectral width (RMS)

3 nm

Output modes

Continuous wave and pulse mode (2-3 Hz


blink frequency)

Connector adapter

2.5 mm universal

VFL laser safety

Class II CDRH

Handheld, rugged, lightweight


Wave ID (auto identication & switching)
Dual or single Wave ID, CW, Tone
270 Hz, 330 Hz, 1 kHz, 2 kHz Tone
Large LCD with backlight (OPM5-2D)
Power measurements in dBm or W; insertion loss
in dB
Reference power level storage
Up to 500 records per wavelength storage
USB port for download of stored records
Windows compatible software to view, print, and
archive stored records
Low battery indicator
Long battery life with 2 x AA alkaline, optional AC
adapter
Free 50 m and 62.5 m mandrels
Cost-effective, easy to use
N.I.S.T traceable

48

Fibre Test Equipment


FibreNet VFL250 Visual Fault Locator

Dust Cap

Light Output

Button

Power Switch

Status LED

The VFL250 Visual Fault Locator (VFL) is a visible light source that
helps you trace optical bers, check ber continuity, and nd faults
such as breaks, bad splices, and tight bends in ber optic cable.

Specifications
Laser source

Class 3A laser diode

Laser wavelength

650 nm (nominal)

Fiber compatibility

Multlmode and singlemode

Output port

Universal adapter for connectors with 2.5 mm


ferrules

Output mode

Continuous or ashing (2-3 Hz)

Output power

>0.5 mW (-3dBm) Into slnglemode ber


Operating

Temperature and
humidity ranges
Storage

0C to 40C
0 to 95%RH (non-condensing)
-20C to +60C
0 to 95%RH (non-condensing)

Battery type and life

Two 1.5V AAA alkaline; 40 hours typical in


continuous mode

Dimensions and
weight

170mm x 13.5mm, 88g (include battery)

Low Battery Indicator

The Status LED will turn to red when batteries


are low

49

Fibre Optic Accessories

50

Fibre Optic Accessories


FibreNet 17 Piece Optic Toolkit
Kit Contents
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.

HT-MJ018A Carbide Scribe


HT-MJ027 Syringe
HT-S144H Stripper
HT-MN002 A/B Fast Epoxy Glue
HT-MN012 CLEANSER
HT-MMB006 ST Polish Disc
HT-MMB005 SC Polish Disc
HT-MN011 Wipe Paper
HT-C151 Kevlar Cutter
HT-MN001 Glasses Working Pad
HT-225H Crimp Tool
HT-MN0041 (6um-Brown Color) Diamond
Polish Film
HT-MN0051 (1um-Purple Color) Diamond
Polish Film
HT-MN0031 (0.05um-White Color) Alum.
Oxide Polish Film
HT-PB042 Rubber Working Pad
HT-MN006 Epoxy Mixer
HT-MN007 Epoxy Mixer Pad

FibreNet 38 Piece Optic Toolkit


Kit Contents
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
*

Polishing Film 3um (5)


Polishing Film 12um (5)
Polishing Film 9um (5)
Multipurpose Wipe Wet/Dry (2)
18ml Cleaning Liquid
Utility Knife With 3 Blade - Includes 24 Snap-0ff Blades
Stainless Steel Forceps 150mm
- Straight PVC Coated Grips
Stainless Steel Forceps 150mm
- Curved PVC Coated Grips
5.5 Electrician Scissors for Fiber Optic Cables
Pocket Lighting Microscope Push-to-Zoom 150x,170x,200x
Label for Fiber Optic Microscope (GM-60)
Size: 95(L) x 12(W)mm
30 PVC Electrical Insulation Tape - Black Color
Tape Measure ABS Case - 3m/10ft 16mm(5/8)
Polish Disc for Fiber Optic SC-ST-FC Connector
Precise Wire Cutter & Stripper
- 2.6-0.8mm/12-22AWG(Stranded)
Crimping Tool for Fiber Optic Die Set
- 0.190, 0.137 (Circle) 0.137, 0.128 (6 Side), 0.190 (5 Side)
Syringe (2)
Carbide Scribe
Stripper for Fiber Optic and 125um Buffer Coating
A/B Fast Epoxy Glue
Rubber Working Pad - Black Color
Glasses Working Pad
Lightweight Carrying Tool
Bag - Black Color

8 weeks delivery period subject to availability

51

Fibre Optic Accessories


FibreNet 68 Piece Optic Toolkit

Kit Contents
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.

Flux Dispensing Bottle 100cc - with Captive Cap.


Polishing Film 3um (5)
Polishing Film 9um (5)
Polishing Film 12um (5)
Stainless Tweezer
2-In-One Mini Screwdriver - Slotted and Phillips
60ml Spray Solution Cleaning Liquid
Utility Knife With 3 Blade - Includes 24 Snap-0ff Blades
5.5 Electrician Scissors for Fiber Optic Cables
Head Magnier With Light and Magnifying Glass
Pocket Lighting Microscope Push-to-Zoom 150x,170x,200x
Label For Fiberopticmicroscope (Gm-60)
Size: 95(L) x 12(W)mm
30 Pvc Electrical Insulation Tape - Black Color
Tape Measure ABS Case with Rubber Cover 3m/10ftx16mm
Small Organiser 137x137x31mm
Polish Disc for Fiber Optic SC-ST-FC Connector
3-In-1 Multipurpose Heating Tool - VDE/GS/CE Approval
Precise Wire Cutter & Stripper - 2.6-0.8mm/12-22AWG (Stranded)
Glasses Working Pad
Rubber Working Pad - Black Color
A/B Fast Epoxy Glue
Cleaner Paper (20)
Stripper for Fiber Optic and 125um Buffer Coating
Carbide Scribe
Syringe (2)
Crimping Tool for Fiber Optic Die Set
- 0.190, 0.137 (Circle) 0.137, 0.128 (6 Side), 0.190 (5 Side)

8 weeks delivery period subject to availability

52

Fibre Optic Accessories


Handheld Fibre Microscope

Features

Led illumination
Laser lter installed for eye protection
Precision optics from 100x to 400x
Versatile adapter interface.
Clear bright images
Smooth focus control
Momentary or push button on/off switch (i.e. ST, SC and FC)
Also available for small form factor connectors (i.e. LC and MU)

Specifications
Optical Magnication

100X, 160X, 200X, 320X, 400X

Power Requirements

3 AAA alkaline batteries

LED

Rated life: 10000 hrs

Weight

0.6kg

Measurement

225mm/8.76 Length x 32mm/1.25 Diameter

Controls

Momentary on/off switch; Fine-Focus control

Laser Safety Filter

Built-in

Adapter interface

Use interchangeable, presented universal or dedicated adapters

The following is the simple inner structure for the two kinds of Hand Held Fiber
Microscope (CL-Series & OL-Series):

How to choose between the CL-Series and the OL-Series?


Both series of our Hand Held Fiber Microscope (CL-Series and OL-Series) provide
excellent views of the ferrule end face. We recommend 400x magnication for singlemode and 200 x magnications for multi-mode:
1. If you frequently terminate ber and have received professional training, you are
probably best served by our CL-Series microscope.
2. If you only occasionally terminate ber, and are unsure, you might consider the
OL-Series.

53

Fibre Optic Accessories


FibreNet Dome Closures FNA-4EDM01
Features

Convenient to increase or reduce trays/ cassette for capacity requirement


3 xing item/designs to prevent ber cable from external effect
Spacious storing tray for storing and maintenance
Can be used from -40 to +65 temperature range
Easy to re-enter without tools
Integrated seal, air tight and water proof, ame-retarded
SGS RoHS test certied
Suitable for aerial, underground duct or direct burial applications

Specifications
Dimension mm DH

190 395

Cable ports

Cable Diameter

4 ports for Max. 16

Max. Capacity (bunchy ber)

96

Core capacity per tray

12F/24F capacity tray available

Sealing structure

Mechanical seal

FibreNet Dome Closures FNA-4EDM02


Features
Reinforce rebar on the body of closure make excellent performance under impact,
pulling, tension etc
Convenient to increase or reduce trays/ cassette for capacity requirement
Spacious storing tray/ cassette for storing and maintenance
3 xing item/designs to prevent ber cable from external effect
Can be used from -40 to +65 temperature range
Easy to re-enter without tools
Integrated seal, air tight and water proof, ame-retarded
SGS RoHS test certied
Suitable for aerial, underground duct or direct burial applications

Specifications

Dimension mm DH

190 395

Cable ports

Cable Diameter

4 ports for Max. 16

Max. Capacity (bunchy ber)

96

Core capacity per tray

12F/24F capacity tray available

Sealing structure

Mechanical seal

5 weeks delivery period subject to availability

54

Fibre Optic Accessories


FibreNet Dome Closures FNA-4EDH01
Features

Convenient to increase or reduce trays/ cassette for capacity requirement


3 xing item/designs to prevent ber cable from external effect
Spacious storing tray for storing and maintenance
Can be used from -40 to +65 temperature range
Easy to re-enter without tools
Integrated seal, air tight and water proof, ame-retarded
SGS RoHS test certied
Suitable for aerial, underground duct or direct burial applications

Specifications
Dimension mm DH

190 410

Cable ports

Cable Diameter

The big port for one cable MAX. 25;


for 2 cables MAX. 12/other;
other 3 ports for Max.16

Max. Capacity (bunchy ber)

96

Core capacity per tray

12F/24F capacity tray available

Sealing structure

Heatshrinkable seal

FibreNet Dome Closures FNA-4EDH02


Features
Convenient to increase or reduce trays/ cassette for capacity requirement
Reinforce rebar on the body of closure make excellent performance under impact,
pulling, tension etc
3 xing item/designs to prevent ber cable from external effect
Spacious storing tray for storing and maintenance
Can be used from -40 to +65 temperature range
Easy to re-enter without tools; Integrated seal, air tight and water proof, ameretarded
SGS RoHS test certied
Suitable for aerial, underground duct or direct burial applications

Specifications

Dimension mm DH

190 435

Cable ports

Cable Diameter

The big port for one cable MAX.25;


for 2 cables MAX.12/other
other 3 ports for Max.16

Max. Capacity (bunchy ber)

96

Core capacity per tray

12F/24F capacity tray available

Sealing structure

Heatshrinkable seal

8 weeks delivery period subject to availability

55

Fibre Optic Accessories


FibreNet Dome Closures FNA-6EH01
Features
Convenient to increase or reduce trays/ cassette for capacity requirement
Improved reinforce rebar on the body of closure make excellent performance
under impact, pulling, tension etc
3 xing item/designs to prevent ber cable from external effect
Spacious place for storing and maintenance
Can be used from -40 to +65 temperature range
Integrated seal, air tight and water proof, ame-retarded
SGS RoHS test certied
Suitable for aerial, underground duct or direct burial applications

Specifications
Item#
Dimension mm LWH

CL-H01A OUTSIDE

CL-H01A INSIDE

H01A

H01B

400200120

40018590

Cable ports

6
2 ports for Max. 16;

Cable Diameter

4 ports for Max. 13

Max. Capacity (bunchy ber)

96

Core capacity per tray

24F capacity tray available

CL-H01B OUTSIDE

CL-H01B INSIDE

FibreNet Dome Closures FNA-2EDH04


Features
Convenient to increase or reduce trays/ cassette for capacity requirement
Improved reinforce rebar on the body of closure make excellent performance
under impact, pulling, tension etc
3 xing item/designs to prevent ber cable from external effect
Can be used from -40 to +65 temperature range
Integrated seal, air tight and water proof, ame-retarded
Exquisite small Dimension design, convenience installation application
SGS RoHS test certied
Suitable for aerial, underground duct or direct burial applications

Specifications

Dimension mm LWH

28020090

Cable ports

Cable Diameter

One in/one out, 2 ports for Max. 14


Two in/two out, 4 ports for Max. 12

Max. Capacity (bunchy ber)

96

Core capacity per tray

24F capacity tray available

4 weeks delivery period subject to availability

56

Glossary

57

Glossary
A
Absorption:

That portion of ber optic attenuation resulting of conversion of optical power to heat.

Analog:

Signals that are continually changing, as opposed to being digitally encoded.

Attenuation Coefcient:

Characteristic of the attenuation of an optical ber per unit length, in dB/km.

Attenuation:

The reduction in optical power as it passes along a ber, usually expressed in decibels (dB).
See optical loss.

Attenuator:

A device that reduces signal power in a ber optic link by inducing loss.

Average power:

The average over time of a modulated signal.

B
Back reection, optical
return loss:

Light reected from the cleaved or polished end of a ber caused by the difference of refractive
indices of air and glass. Typically 4% of the incident light. Expressed in dB relative to incident
power.

Backscattering:

The scattering of light in a ber back toward the source, used to make OTDR measurements.
Bandwidth: The range of signal frequencies or bit rate within which a ber optic component,
link or network will operate.

Bending loss,
microbending loss:

Loss in ber caused by stress on the ber bent around a restrictive radius. Bit-error rate (BER):
The fraction of data bits transmitted that are received in error.

Bit:

An electrical or optical pulse that carries information.

Buffer:

A protective coating applied directly on the ber.

C
Cable:

One or more bers enclosed in protective coverings and strength members.

Cable Plant, Fiber Optic:

The combination of ber optic cable sections, connectors and splices forming the optical path
between two terminal devices.

CATV:

An abbreviation for Community Antenna Television or cable TV.

Chromatic dispersion:

The temporal spreading of a pulse in an optical waveguide caused by the wavelength


dependence of the velocities of light.

Cladding:

The lower refractive index optical coating over the core of the ber that traps light into the
core. Connector: A device that provides for a demountable connection between two bers or a
ber and an active device and provides protection for the ber.

Core:

The center of the optical ber through which light is transmitted.

Coupler:

An optical device that splits or combines light from more than one ber.

Cutback method:

A technique for measuring the loss of bare ber by measuring the optical power transmitted
through a long length then cutting back to the source and measuring the initial coupled power.

Cutoff wavelength:

The wavelength beyond which singlemode ber only supports one mode of propagation.

D
dBm:

Optical power referenced to 1 milliwatt.

Decibel (dB):

A unit of measurement of optical power which indicates relative power on a logarithmic scale,
sometimes called dBr. dB=10 log ( power ratio)

Detector:

A photodiode that converts optical signals to electrical signals.

Digital:

Signals encoded into discrete bits.

Dispersion:

The temporal spreading of a pulse in an optical waveguide. May be caused by modal or


chromatic effects.

E
EDFA:

Erbium-doped ber amplier, an all optical amplier for 1550 nm SM transmissionsystems.

Edge-emitting diode
(E-LED):

A LED that emits from the edge of the semiconductor chip, producing higher power and
narrower spectral width.

End nish:

The quality of the end surface of a ber prepared for splicing or terminated in a connector.

Equilibrium modal
distribution (EMD):

Steady state modal distribution in multimode ber, achieved some distance from the source,
where the relative power in the modes becomes stable with increasing distance.

ESCON:

IBM standard for connecting peripherals to a computer over ber optics. Acronym for
Enterprise System Connection.

Excess loss:

The amount of light lost in a coupler, beyond that inherent in the splitting to multiple output
bers.

58

Glossary
F
Fiber Amplier:

An all optical amplier using erbium or other doped bers and pump lasers to increase
signal output power without electronic conversion.

Fiber Distributed Data


Interface, FDDI:

100 Mb/s ring architecture data network.

Ferrule:

A precision tube which holds a ber for alignment for interconnection or termination. A
ferrule may be part of a connector or mechanical splice.

Fiber tracer:

An instrument that couples visible light into the ber to allow visual checking of continuity
and tracing for correct connections.

Fiber identier:

A device that clamps onto a ber and couples light from the ber by bending, to identify
the ber and detect high speed trafc of an operating link or a 2 kHz tone injected by a test
source.

Fiber optics:

Light transmission through exible transmissive bers for communications or lighting.

FO:

Common abbreviation for ber optic.

Fresnel reection, back


Light reected from the cleaved or polished end of a ber caused by the difference of
reection, optical return loss: refractive indices of air and glass. Typically 4% of the incident light.
Fusion splicer:

An instrument that splices bers by fusing or welding them, typically by electrical arc.

G
Graded index (GI):

A type of multimode ber which used a graded prole of refractive index in the core material
to correct for dispersion.

I
Index of refraction:

A measure of the speed of light in a material.

Index matching uid:

A liquid used of refractive index similar to glass used to match the materials at the ends of
two bers to reduce loss and back reection.

Index prole:

The refractive index of a ber as a function of cross section.

Insertion loss:

The loss caused by the insertion of a component such as a splice or connector in an optical
ber.

J
Jacket:

The protective outer coating of the cable.

Jumper cable:

A short single ber cable with connectors on both ends used for interconnecting other
cables or testing.

L
Laser diode, ILD:

A semiconductor device that emits high powered, coherent light when stimulated by an
electrical current. Used in transmitters for singlemode ber links.

Launch cable:

A known good ber optic jumper cable attached to a source and calibrated for output power
used used as a reference cable for loss testing. This cable must be made of ber and
connectors of a matching type to the cables to be tested.

Light-emitting diode, LED:

A semiconductor device that emits light when stimulated by an electrical current. Used in
transmitters for multimode ber links.

Link, ber optic:

A combination of transmitter, receiver and ber optic cable connecting them capable of
transmitting data. May be analog or digital.

Long wavelength:

A commonly used term for light in the 1300 and 1550 nm ranges.

Loss, optical:

The amount of optical power lost as light is transmitted through ber, splices, couplers, etc.

Loss budget:

The amount of power lost in the link. Often used in terms of the maximum amount of loss
that can be tolerated by a given link.

59

Glossary
M
Margin:

The additional amount of loss that can be tolerated in a link.

Mechanical splice:

A semi-permanent connection between two bers made with an alignment device and index
matching uid or adhesive.

Micron (*m):

A unit of measure, 10-6 m, used to measure wavelength of light.

Microscope, ber optic


inspection:

A microscope used to inspect the end surface of a connector for aws or contamination or a
ber for cleave quality.

Modal dispersion:

The temporal spreading of a pulse in an optical waveguide caused by modal effects.

Mode eld diameter:

A measure of the core size in singlemode ber.

Mode lter:

A device that removes optical power in higher order modes in ber.

Mode scrambler:

A device that mixes optical power in ber to achieve equal power distribution in all modes.
Mode stripper: A device that removes light in the cladding of an optical ber.

Mode:

A single electromagnetic eld pattern that travels in ber.

Multimode ber:

A ber with core diameter much larger than the wavelength of light transmitted that allows
many modes of light to propagate. Commonly used with LED sources for lower speed, short
distance links.

N
Nanometer (nm):

A unit of measure , 10-9 m, used to measure the wavelength of light.

Network:

A system of cables, hardware and equipment used for communications.

Numerical aperture (NA):

A measure of the light acceptance angle of the ber.

O
Optical amplier:

A device that amplies light without converting it to an electrical signal.

Optical ber:

An optical waveguide, comprised of a light carrying core and cladding which traps light in
the core.

Optical loss test set (OLTS): An measurement instrument for optical loss that includes both a meter and source.
Optical power:

The amount of radiant energy per unit time, expressed in linear units of Watts or on a
logarithmic scale, in dBm (where 0 dB = 1 mW) or dB* (where 0 dB*=1 microWatt).

Optical return loss, back


reection:

Light reected from the cleaved or polished end of a ber caused by the difference of
refractive indices of air and glass. Typically 4% of the incident light. Expressed in dB relative
to incident power.

Optical switch:

A device that routes an optical signal from one or more input ports to one or more output
ports.

Optical time domain


reectometer (OTDR):

An instruments that used backscattered light to nd faults in optical ber and infer loss.

Overlled launch:

A condition for launching light into the ber where the incoming light has a spot size and NA
larger than accepted by the ber, lling all modes in the ber.

P
Photodiode:

A semiconductor that converts light to an electrical signal, used in ber optic receivers.

Pigtail:

A short length of ber attached to a ber optic component such as a laser or coupler.

Plastic optical ber (POF):

An optical ber made of plastic.

Plastic-clad silica (PCS)


ber:

A ber made with a glass core and plastic cladding.

Power budget:

The difference (in dB) between the transmitted optical power (in dBm) and the receiver
sensitivity (in dBm).

Power meter, ber optic:

An instrument that measures optical power emanating form the end of a ber.

Preform:

The large diameter glass rod from which ber is drawn.

60

Glossary
R
Receive cable:

A known good ber optic jumper cable attached to a power meter used as a reference cable
for loss testing. This cable must be made of ber and connectors of a matching type to the
cables to be tested.

Receiver:

A device containing a photodiode and signal conditioning circuitry that converts light to an
electrical signal in ber optic links.

Refractive index:

A property of optical materials that relates to the velocity of light in the material.

Repeater, regenerator:

A device that receives a ber optic signal and regenerates it for retransmission, used in very
long ber optic links.

S
Scattering:

The change of direction of light after striking small particles that causes loss in optical
bers.

Short wavelength:

A commonly used term for light in the 665, 790, and 850 nm ranges.

Singlemode ber:

A ber with a small core, only a few times the wavelength of light transmitted, that only
allows one mode of light to propagate. Commonly used with laser sources for high
speed, long distance links.

Source:

A laser diode or LED used to inject an optical signal into ber.

Splice (fusion or mechanical):

A device that provides for a connection between two bers, typically intended to be
permanent.

Splitting ratio:

The distribution of power among the output bers of a coupler.

Steady state modal distribution:

Equilibrium modal distribution (EMD) in multimode ber, achieved some distance from
the source, where the relative power in the modes becomes stable with increasing
distance.

Step index ber:

A multimode ber where the core is all the same index of refraction.

Surface emitter LED:

A LED that emits light perpendicular to the semiconductor chip. Most LEDs used in
datacommunications are surface emitters.

T
Talkset, ber optic:

A communication device that allows conversation over unused bers.

Termination:

Preparation of the end of a ber to allow connection to another ber or an active device,
sometimes also called connectorization.

Test cable:

A short single ber jumper cable with connectors on both ends used for testing. This
cable must be made of ber and connectors of a matching type to the cables to be
tested.

Test kit:

A kit of ber optic instruments, typically including a power meter, source and test
accessories used for measuring loss and power.

Test source:

A laser diode or LED used to inject an optical signal into ber for testing loss of the ber
or other components.

Total internal reection:

Connement of light into the core of a ber by the reection off the core-cladding
boundary.

Transmitter:

A device which includes a LED or laser source and signal conditioning electronics that
is used to inject a signal into ber.

V
VCSEL:

vertical cavity surface emitting laser, a type of laser that emits light vertically out of the
chip, not out the edge.

Visual fault locator:

A device that couples visible light into the ber to allow visual tracing and testing of
continuity. Some are bright enough to allow nding breaks in ber through the cable
jacket.

W
Watts:

A linear measure of optical power, usually expressed in milliwatts (mW), microwatts


(*W) or nanowatts (nW).

Wavelength:

A measure of the color of light, usually expressed in nanometers (nm) or microns (*m).

Wavelength division
multiplexing (WDM):

A technique of sending signals of several different wavelengths of light into the ber
simultaneously.

Working margin:

The difference (in dB) between the power budget and the loss budget (i.e. the excess
power margin).

61

Notes

62

Notes

63

Notes

64

Notes

65

Notes

Distributed by:

Head Ofce, Johannesburg


Falcon House
8 Simmonds Street Cnr. Webber Street
Selby 2001
Johannesburg
Tel (S-board): +27 (0) 11 630 1000
Fax : +27 (0) 11 630 1229
Bloemfontein
3 Walter Raath Street
Ooseinde 9301
PO Box 2164
Bloemfontein 9300
Tel +27 (0) 51 432 4063
Fax: +27 (0) 51 432 4661
Cape Town
Falcon House
19 Woodlands Road
Woodstock 7925
PO Box 99
Woodstock 7915
Tel: +27 (0) 21 486 8700
Fax: +27 (0) 21 448 2485
Durban
705-707 Chris Hani Road (North Coast Road)
Redhill 4051
PO Box 201398
Durban North 4016
Tel: +27 (0) 31 581 6300
Fax: +27 (0) 31 563 2321
Port Elizabeth
25 Mangold Street
Newton Park
Port Elizabeth 6001
South Africa
Tel: +27 (0) 41 391 0800
Fax: +27 (0) 41 363 0607

E-mail: info@fe.co.za

Website: www.falconelectronics.co.za

Potrebbero piacerti anche